PubMed HealthSearch

Biomedical subjects

C Barax

Publications and source records attributed to C Barax.

3 recordsLinked to original sources

Magnetic resonance imaging of occult fractures of the proximal femur.

The evaluation of the painful hip in the elderly osteoporotic patient with normal plain radiographs can be difficult. We studied 15 osteopenic patients with normal plain radiographs and suspected hip fractures with magnetic resonance (MR) imaging and found MR to be an excellent aid in detecting occult fractures. A clear fracture was seen in 10 of the 15 patients, who then underwent surgical repair based on the MR study. The remaining patients had no MR-demonstrable fracture and were successfully treated nonoperatively. Some believe that a negative bone scan in this population of patients should be repeated within 3 days prior to a definitive "no fracture" decision being made. Unfortunately, bone scanning lacks spatial resolution, and increased osteoblastic activity may be caused by other pathologic processes besides fracture. Two of the 15 patients had MR-demonstrated bone infarcts near the fracture. One patient also had femoral head osteonecrosis on the side of the fracture. One patient with metastatic prostatic carcinoma had a hip fracture and one patient with metastatic breast carcinoma had no fracture. No only is MR imaging an excellent technique for delineating occult fractures, but due to its spatial resolution, associated bone disorders adjacent to fractures can be detected in most instances. From a cost perspective, rapid diagnosis and early treatment of an occult femoral fracture is advisable. A reduced hospital stay pending diagnosis and the early institution of definitive therapy also decrease the chance that a simple non-displaced fracture will displace and require more complex management with resultant increased morbidity and cost.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Candida epiglottitis presenting as stridor in a child with HIV infection.

Invasive laryngeal candidiasis is an uncommon cause of epiglottitis, seen most often in immunocompromised or antibiotic-treated patients. We present the clinical and radiographic findings in an HIV-infected infant who developed significant stridor due to candidal epiglottitis. Stridor or hoarseness of unknown cause in an immunocompromised patient should lead to prompt evaluation for opportunistic laryngeal infection.

Acquired Immunodeficiency Syndrome

CT scans through metal scanning technique versus hardware composition.

OBJECTIVE: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. METHODS: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360 degrees rotation, 140 kVp, 140 mA, 3 s, 360 degrees rotation, 140 kVp, 140 mA, 4 s, 420 degrees rotation. RESULTS: Titanium was superior to cobalt-chrome (p < .0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420 degrees compared to the standard 360 degrees. CONCLUSION: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420 degrees scan arc to improve the image quality of bone surrounded by metal.

Acetabulum