PubMed Health⌕ Search

Biomedical subjects

C Bergström

Publications and source records attributed to C Bergström.

21 records · Page 2Linked to original sources

Ceramic implant abutments used for short-span fixed partial dentures: a prospective 2-year multicenter study.

PURPOSE: This is a 2-year report from an ongoing prospective 5-year multicenter study. The aim of the study was to evaluate the short- and long-term clinical function of CerAdapt ceramic abutments supporting short-span fixed partial dentures (FPD). MATERIALS AND METHODS: Initially, 105 Brånemark System implants were placed in a total of 32 patients at 3 different clinics. After initial healing 103 implants remained. For the support of 36 FPDs, 53 ceramic and 50 titanium abutments were connected, 19 on ceramic and 17 on titanium abutments. RESULTS: All patients remained in the study after 2 years. There was a cumulative survival rate of 97.1% for implants and a cumulative success rate of 97.2% for FPDs (94.7% for ceramic and 100% for titanium abutment-supported FPDs). One of 53 ceramic but none of 50 titanium abutments failed, giving a cumulative success rate of 98.1% and 100%, respectively, for the abutments. Soft tissue around abutments and adjacent teeth appeared healthy. More crown margins were placed submucosally at titanium (31%) than at ceramic (14%) abutments, and the level of the periimplant mucosa was relatively stable in relation to the abutment/crown. No differences were seen between ceramic and titanium abutments regarding bleeding of the periimplant mucosa. There was a minimal marginal bone loss recorded after 1 year, which was slightly more at titanium (0.4 mm) than at ceramic (0.2 mm) abutments. All patients and dentists were satisfied with the achieved esthetic result and no FPD was remade because of compromised esthetics. CONCLUSION: So far the ceramic abutments have worked very well and the 2-year results have been very encouraging for CerAdapt abutments supporting short-span FPDs. However, ceramic materials tend to undergo static fatigue, and it is therefore important to wait for the 5-year results before making any more definite statement about the long-term prognosis for CerAdapt abutments.

Alveolar Bone Loss↗

Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Brånemark System implants.

The present study evaluated implant survival and marginal bone loss in maxillae over a 15-year follow-up period as a function of either monocortical or bicortical implant anchorage. Of 207 standard Brånemark implants (10 mm in length) followed, 110 implants were judged to be monocortically anchored and 97 as bicortically anchored. The bicortically anchored implants failed nearly 4 times more often than the monocortical ones. Implant fractures accounted for over 80% of the observed failures and were found to affect the bicortical group almost 3 times more often. As tentative explanations, induction of increased stress and bending forces resulting from possible prosthetic misfit, presence of unfavorable arch relationships, or high occlusal tables in combination with bicortically anchored implants have been suggested, all indicating an overambitious fixation of the bicortical anchorage. Total marginal bone loss was low over the 15-year period and close to identical for the 2 groups, suggesting that the mode of cortical anchorage did not have any clinically significant influence on marginal bone remodeling.

Adult↗

A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

PURPOSE: The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. MATERIALS AND METHODS: Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. RESULTS: Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. CONCLUSION: The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

Adolescent↗