PubMed HealthSearch

Biomedical subjects

C Birkett

Publications and source records attributed to C Birkett.

3 recordsLinked to original sources

Problems in measuring heart rate variability of patients with congestive heart failure.

Heart rate variability (HRV) has become an important noninvasive measure of the integrity of the autonomic nervous system in various disease states. The power spectrum of HRV is a means to separate the instability oscillations of the various feedback mechanisms that contribute to cardiovascular homeostasis. The reliability of HRV data is largely unexplored. The day-to-day correlations in the low and mid-frequency components of HRV spectra average 91%, and that of the high-frequency component averages 81%. The correlations among spectral and nonspectral measures of HRV (SD) for the same data segment average 50-60%, suggesting that they encode similar information. Heart rate variability spectra exhibit diurnal variation consistent with physiologic expectation: respiratory sinus arrhythmia (thought to be mediated by parasympathetic tone) and to a lesser extent, the low-frequency spectral component (thought to be of mixed sympathetic-parasympathetic origin) are higher at night than in the daytime; the mid-frequency component (associated with the baroreflex, which is more excited when the patient is upright) is slightly higher during the daytime. Increased frequency of ectopic beats, such as occurs in congestive heart failure, reduces the reliability of the power spectrum since the number of usable data segments falls off rapidly with even small increases in rate of ectopy, and the variance of the estimate (in the method of averaged periodograms) is inversely proportional to the square root of the number of data segments. Using shorter data segments increases the number of segments available, but reduces resolution. Interpolation over ectopic beats (by either linear or cubic splint interpolation) increases the apparent power in low frequencies.(ABSTRACT TRUNCATED AT 250 WORDS)

Electrocardiography

Transthoracic defibrillation using sequential and simultaneous dual shock pathways: experimental studies.

Dual pathway sequential DC shocks reduce energy requirements for internal defibrillation. Our purpose was to determine if dual pathway shocks similarly reduce energy requirements or improve shock success in transthoracic (external) defibrillation. We studied 39 closed-chest anesthetized mongrel dogs. The dual pathways used were left chest to right chest and left chest to posterior. In eight dogs we also assessed dual shock pathways oriented orthogonally, left lower chest to right upper chest and left upper chest to right lower chest. Four different dual pathway groups were studied: group 1: simultaneous shocks, sinusoidal waveform; group 2: sequential shocks, sinusoidal waveform, 100-msec shock separation, orthogonal shock pathways; group 3: sequential shocks, sinusoidal waveform, 100 msec shock separation; and group 4: sequential shocks, rectangular waveform (sequential shocks: 2 pulses, 2.5 msec each, 0.1-msec separation; single shock: 1 pulse, 5 msec). Shocks were given at 50 (J) joules, 100 J and 150 J and curves of energy versus success compared for dual pathway shocks versus single shocks. We found that the highest mean success rates (96 +/- SD 9%) were achieved by simultaneous sinusoidal waveform dual pathway shocks at 100 J; this was identical to results achieved by the single pathway sinusoidal waveform comparison shocks at 100 J. Sequential dual pathway sinusoidal shocks separated by 100 msec achieved a mean success rate of 79 +/- 31% at 150 J; the comparison single pathway mean success rate was similar: 81 +/- 22% at 150 J. Thus, dual pathway sequential or simultaneous transthoracic shocks did not demonstrate clear superiority over single pathway shocks.

Animals