PubMed Health⌕ Search

Biomedical subjects

C Bor Fuh

Publications and source records attributed to C Bor Fuh.

7 recordsLinked to original sources

Analytical and preparative applications of magnetic split-flow thin fractionation on several ion-labeled red blood cells.

BACKGROUND: Magnetic Split-flow thin (SPLITT) fractionation is a newly developed technique for separating magnetically susceptible particles. Particles with different field-induced velocities can be separated into two fractions by adjusting applied magnetic forces and flow-rates at inlets and outlets. METHODS: Magnetic particles, Dynabeads, were used to test this new approach of field-induced velocity for susceptibility determination using magnetic SF at different magnetic field intensities. Reference measurements of magnetic susceptibility were made using a superconducting quantum interference device (SQUID) magnetometer. Various ion-labeled red blood cells (RBC) were used to study susceptibility determination and throughput parameters for analytical and preparative applications of magnetic SPLITT fractionation (SF), respectively. Throughputs were studied at different sample concentrations, magnetic field intensities, and channel flow-rates. RESULTS: The susceptibilities of Dynabeads determined by SPLITT fractionation (SF) were consistent with those of reference measurement using a superconducting quantum interference device (SQUID) magnetometer. Determined susceptibilities of ion-labeled RBC were consistent within 9.6% variations at two magnetic intensities and different flow-rates. The determined susceptibilities differed by 10% from referenced measurements. The minimum difference in magnetic susceptibility required for complete separation was about 5.0 x 10(-6) [cgs]. Sample recoveries were higher than 92%. The throughput of magnetic SF was approximately 1.8 g/h using our experimental setup. CONCLUSION: Magnetic SF can provide simple and economical determination of particle susceptibility. This technique also has great potential for cell separation and related analysis. Continuous separations of ion-labeled RBC using magnetic SF were successful over 4 hours. The throughput was increased by 18 folds versus early study. Sample recoveries were 93.1 +/- 1.8% in triplicate experiments.

Journal Article↗

Separation method based on affinity reaction between magnetic and nonmagnetic particles for the analysis of particles and biomolecules.

A separation method is reported for particle and biochemical analysis based on affinity interactions between particle surfaces under magnetic field. In this method, magnetic particles with immunoglobulin G (IgG) or streptavidin on the surface are flowed through a separation channel to form a deposition matrix for selectively capturing nonmagnetic analytes with protein A or biotin on the surface due to specific antigen (Ag)--antibody (Ab) interactions. This separation method was demonstrated using model reactions of IgG--protein A and streptavidin-biotin on particle surface. The features of this new separation method are (1) the deposited Ag-Ab complex can be examined and further analyzed under the microscope, (2) a kinetic study of complex binding is possible, and (3) the predeposited matrix can be formed selectively and changed easily. The detection limits were about 10(-11) g. The running time was less than 10 min. The selectivities of studied particles were 94% higher than those of label-controlled particles. This method extends the applications of analytical magnetapheresis to nonmagnetic particles. Preliminary study shows that this separation method has a great potential to provide a simple, fast, and selective analysis for particles, blood cells, and immunoassay related applications.

Biotin↗

Solid-phase microextraction coupled with liquid chromatography for determination of beta-carotene in food.

Beta-carotene in vegetables and nutritional products is analyzed using solid-phase microextraction (SPME) coupled with liquid chromatography (LC) to improve the speed of analysis and to reduce the consumption of organic solvents. The relative standard deviations (RSDs) of this analytical method for beta-carotene determinations in vegetables and nutritional products are approximately 10% and 5%, respectively. The amount of beta-carotene was found to vary from 0.35 +/- 0.05 ppm to 76.5 +/- 6.9 ppm for several vegetables in Taiwan. This method was linear over the range of 0.4-40 ppm with correlation coefficients higher than 0.997. The experimentally determined level of beta-carotene in nutritional products varied from 3.8 +/- 0.2 ppm to 24.6 +/- 1.1 ppm following SPME-LC. The recoveries of beta-carotene for these measurements following SPME were all higher than 97% +/- 2% (n = 3). The detection limits of beta-carotene for this method were from 0.027 to 0.054 ppm. Conventional solvent extractions take approximately 4-6 h for extraction and reconcentration but SPME takes approximately 1 h. From several tens to hundreds of milliliters, organic solvents can be saved using SPME. SPME provides better analyses on beta-carotene than conventional solvent extraction for nutritional products in terms of speed, precision, simplicity, and solvent consumption.

Beverages↗

New method of blood typing using analytical magnetapheresis.

We report a new method of blood typing based on the agglutination of red blood cell (RBC) with serum-treated magnetic particles in analytical magnetapheresis. Blood typing of ABO was demonstrated. The agglutination patterns of RBCs are different for different blood types and can be used to determine the ABO blood typing in analytical magnetapheresis. Six samples can be tested in each run. The running time was less than 10 min. Magnetic particles were prepared in the laboratory. The amount of RBCs needed for the agglutination test was about 1.0 microl of adult blood. The blood typing of ABO was used to illustrate the capable applications of analytical magnetapheresis to nonmagnetic samples like cells without magnetic labels. Analytical magnetapheresis has a great potential for cell related analysis.

ABO Blood-Group System↗

Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.

1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The relative standard deviation (R.S.D.) values of each analytical method were smaller than 3%. The amount of 1,4-dioxane was found to vary from 11.6 +/- 0.3 ppm to 73.5 +/- 0.5 ppm in 30% of nonionic surfactants from manufacturers in Taiwan. These methods were linear over the studied range of 3-150 ppm with correlation coefficients higher than 0.995. The recoveries of 1,4-dioxane for these nonionic surfactants following SPME were all higher than 96 +/- 1% (n = 3). The detection limits of 1,4-dioxane for these nonionic surfactants following SPME were from 0.06 ppm to 0.51 ppm. The experimentally determined level of 1,4-dioxane in cosmetics from manufacturers in Taiwan varied from 4.2 +/- 0.1 ppm to 41.1 +/- 0.6 ppm in 22% of daily used cosmetics following SPME coupled with GC and GC-MS. Conventional solvent extraction takes around 1 h for extraction and reconcentration but SPME takes only around 10 min. SPME provides better analyses of 1,4-dioxane in nonionic surfactants and cosmetics than conventional solvent extraction and head space pretreatments in term of simplicity, speed, precision, detection limit, and solvent consumption.

Calibration↗

Determination of magnetic susceptibility of various ion-labeled red blood cells by means of analytical magnetapheresis.

Analytical magnetapheresis is a newly developed technique for separating magnetically susceptible particles. The magnetically susceptible particles are deposited on a bottom plate after flowing through a thin (< 0.05 cm) separation channel under a magnetic field applied perpendicular to the flow. Particles with various magnetic susceptibilities can be selectively deposited and separated by adjusting the applying magnetic force and flow rates. Magnetic susceptibility is an important parameter for magnetic separation. Magnetic susceptibility determination of various ion-labeled red blood cells (RBCs) using analytical magnetapheresis with a simple theoretical treatment is reported in this study. Susceptibility determination is based on the balance between maximal channel flow rate and magnetically induced flow rate for deposition. We tried a new approach to determine particle magnetic susceptibilities using a balance of magnetic and drag forces to control magnetically induced particle velocities. The Er3+, Fe3+, Cu2+, Mn2+, Co2+, and Ni2+ ions were used to label RBC at various labeling concentrations for susceptibility determination. The susceptibilities determined for various ion-labeled RBC under two magnetic field intensities fell within a 10% range. The average viabilities of various ion-labeled RBCs were 96.1 +/- 0.8%. The susceptibility determination generally took less than 10 min. Determined susceptibilities from analytical magnetapheresis differed by 10% from reference measurements using a superconducting quantum interference device (SQUID) magnetometer. The cost and time for analysis is much less using analytical magnetapheresis. This technique can provide a simple, fast, and economical way for particle susceptibility determinations.

Cations↗

Rapid diffusion coefficient measurements using analytical SPLITT fractionation: application to proteins.

This work reports a new technique for the rapid measurement of diffusion coefficients using a special flow cell called a SPLITT cell. Such SPLITT cells, designed for continuous SPLITT fractionation, utilize differential transport across a thin (approximately 100 microns) ribbonlike lamina flowing through the cell. The liquid stream in the cell is split into two substreams at the outlet. The relative concentration in the two outlet substreams of a dilute component introduced into one of two inlet substreams is mathematically related to the appropriate transport coefficient, in this case the diffusion coefficient D. Thus D can be calculated from measured values of relative outlet concentrations. This approach has been tested using a number of dilute protein solutions. The results at different stream-splitting ratios are reasonably self-consistent and agree with most literature values for D within 5%. This approach provides a simple, rapid, and predictable means for determining the diffusion coefficients of proteins and other substances.

Animals↗