PubMed Health⌕ Search

Biomedical subjects

C Bosqué

Publications and source records attributed to C Bosqué.

2 recordsLinked to original sources

Are auditory warnings in the intensive care unit properly adjusted?

The purpose of this study was to determine whether auditory warnings in the intensive care unit (ICU) were properly adjusted. An intervention study (before- and-after assessment) was conducted in a 12-bed medical-surgical ICU of an acute-care teaching hospital in Barcelona, Spain. A total of 100 patients with stable haemodynamic and respiratory parameters were included. In the first 3-month phase of the study, minimum and maximum alarm parameters of breathing rate, expired volume/min, airway pressure, SaO(2), arterial blood pressure and heart rate were recorded. In the second 12-month phase of the study, the same alarm parameters were recorded every 4 hours in the patient's medical record. In the third 3-month phase of the study, alarm readings were recorded again as in the first phase. The change throughout coefficient of variation (CV) and the 95% confidence interval (CI) for each alarm were calculated. Following the intervention, there was a statistically significant improvement in alarm readings for expired volume, heart rate and systolic blood pressure, so that alarms had been more properly adjusted to the patient's real value. Nursing staff should be aware that auditory warnings in ICU stable patients are frequently set very far from suitable values. Recording of alarm parameters in the patient's medical record as a routine daily activity was an effective intervention for improving adjustment of auditory warnings.

Calibration↗

[Variability in working systems in intensive care units].

INTRODUCTION: Patients attended in Intensive Medicine Services (IMS) require a high therapeutic support. To do so, each IMS elaborates a work system (monitoring of constants, insertion of catheters,...) aiming to respond to these high necessities of therapy. The objective of this study is to describe the variability among different IMS. METHODS: The study was performed in 15 hospitals in Catalonia between April and May 1995. In the end two of them did not participate in the study. In each hospital 180 pieces of data were collected referring to their material and human resources, graphics of data collection, monitoring of respiratory system (mechanical ventilator, aspirations of secretions, tracheostomy care), techniques of catheterization of artery and venous via vesical probing, prevention of pressure ulcers , hygiene of patients, nutrition, family treatment and data about medical orders and nursing courses. Similarly, the fact whether the work system was justified by studies from the same IMS, other centres, or whether it was simply unknown, was also evaluated. RESULTS: There was a great variability among the IMS studied, oscillating significatively according to assigned resources, frequency of action and cost. According to the procedure 61% of IMS did not justify the work systems depending on scientific data. CONCLUSION: it is necessary to unify the different work systems. To do so, and in our opinion, scientific societies should establish common norms, guidelines and protocols so as to obtain a higher efficiency of IMS.

Humans↗