Imaging and relative quantification of 127I in human thyroid follicles by analytical ion microscope: characterization of benign thyroid epithelial tumors.

Analytical ion microscopy (AIM) can be used for imaging and relative quantification of chemical elements in tissue sections. We used this technique to assess the changes in 127I mapping within thyroid follicular cells and follicular lumina in benign thyroid epithelial abnormalities from 17 patients and in macroscopically normal perinodular tissue surrounding solitary cold nodules from 8 patients. Among the 17 patients, 9 had simple goiters, 5 had toxic nodular goiters, and 3 had hypofunctioning (cold) nodules. The tissue samples were fixed chemically and embedded in methacrylate resin to ensure preservation of organified iodine, and thin sections were analyzed by AIM. 127I was found in the follicular lumina and follicular epithelial cells of most specimens. The local concentration of 127I, which is proportional to the ratio of the two secondary ion beam currents of iodine and carbon, was evaluated in 30 follicular lumina and 30 follicular epithelial cells of each specimen. In normal tissue, the relative 127I concentration within follicular cells (mean, 0.72; range 0.01-8.30) was much lower than that in follicular lumina (mean, 4.63; range, 0.18-36.74). In simple goiter tissue, follicular lumen (mean, 0.57; range, 0.00-5.76), and cell (mean, 0.17; range, 0.002-1.82) relative 127I concentrations were below normal, but both distributions remained different. On the contrary, in toxic nodular goiter tissue the follicular cell relative 127I concentration (mean, 0.96; range, 0.003-27.3) largely overlapped that of the follicular lumina (mean, 2.1; range, 0.001-36.5). The cold nodules had the lowest relative follicular lumina 127I concentration (mean, 0.008; range, undetectable-0.07), and the relative cellular 127I concentrations were undetectable in 67%. These results demonstrate the capacity of AIM to characterize the functional activity of thyroid tissue without prior administration of radio-iodine.

Adult↗

Changes in iodine mapping in rat thyroid during the course of iodine deficiency: imaging and relative quantitation by analytical ion microscope.

The analytical ion microscope (AIM) makes possible imaging and relative quantitation of multiple stable or labeled elements on an even tissue section, according to their mass. The purpose of this work was to follow at the rat thyroid follicle level the changes in 127I mapping during low iodine diet (LID) in relation to the ability of thyroid to pick up radioiodine (129I) and to synthesize Tg from its precursor, 2H-labeled leucine. The overall picture of images and countings of 127I shows a progressive decrease of the luminal iodine concentration which on day 80 was 10-fold lower than that of control value. In control rat thyroid cell, concentration was 10-fold lower than that of follicular lumina and was unchanged until 35 days, but the size of the cytoplasmic compartment increased, suggesting a redistribution of iodine stores between thyroid cells and follicular lumina. 129I was always found in colloid as well as in cells at all stages. After 35 days of LID, cytoplasmic and luminal radioiodine concentrations decreased. In control rats, [2H]leucine was found mainly in the cells. During LID its localization was evidenced progressively in most of the lumina. The most striking fact was the presence up to 35 days of some large residual follicles with high 127I concentration and low 129I and 2H incorporation. These data demonstrate the follicular heterogeneity of thyroid response to progressive chronic TSH stimulation induced by LID.

Animals↗

Acute effects of various doses of iodide on thyroid iodine autoregulation. A study with 129I by means of analytical ion microscopy.

Analytical ion microscopy (AIM) was used to determine alterations in the thyroid follicular lumen 127I stores of Wistar rats injected with different doses of 129I (low specific activity radionuclide). Animals fed a normal iodine diet (10 micrograms 127I/d) were divided into four groups: control group and three treated groups injected ip 24 h before sacrifice with 129I at doses of 10 micrograms (group 1), 30 micrograms (group 2), and 8500 micrograms (group 3). AIM was performed on thyroid semithin sections. The mean 129I concentration increased with the dose injected from group 1 (0.44 +/- 0.03 micrograms/mg, mean +/- SEM) to group 2 (2.05 +/- 0.14 micrograms/mg) and decreased in group 3 (0.57 +/- 0.08 microgram/mg). When compared to control group (4.14 +/- 0.17 micrograms/mg), the mean 127I concentration was not changed in group 1 (4.52 +/- 0.07 micrograms/mg), but altered in the other groups: It was significantly increased (7.14 +/- 0.41 micrograms/mg) in group 2 and slightly decreased (3.11 +/- 0.26 micrograms/mg) in group 3. These results underline the interest of AIM in the study of the effects of various doses of iodide on the thyroid autoregulation by iodide, a trace element actively trapped by this gland.

Animals↗

New features of the IC(4) code and comparison of internal conversion coefficient calculations.

The IC(4) software developed to compare calculated internal conversion coefficients (ICC) has been enhanced by adding new features through the use of Borland Delphi and TeeChart. Particularly, the 3D-graph option enhances the possibilities of analyzing calculated ICC values. For example, the comparison between the results given by three sets of theoretical ICC tables for any arbitrary pair of calculated ICC can be presented in a much clearer manner. Their differences can be displayed as energy vs. atomic number surfaces. Results from the analyses of K-shell and total ICCs for E2, E3, M2, M3, and M4 multipolarity are discussed.

Journal Article↗