PubMed HealthSearch

Biomedical subjects

C Briguori

Publications and source records attributed to C Briguori.

10 recordsLinked to original sources

Influence of left ventricular cavity size on clinical presentation in hypertrophic cardiomyopathy.

The aim of this study was to assess whether left ventricular (LV) cavity size relates to functional impairment and syncope in patients with hypertrophic cardiomyopathy (HC). LV diastolic dysfunction influences functional limitation in HC. A reduced LV end-diastolic dimension may underlie impaired diastolic properties and be implicated in hemodynamic syncope. Eighty-two consecutive patients with HC (off drugs, in sinus rhythm) underwent echocardiography to measure LV end-diastolic dimension in the short-axis view (indexed to the body surface area) and radionuclide angiography (n = 50) to calculate peak filling rate (normalized to stroke counts/s). Patients in New York Heart Association functional classes II to IV had smaller LV end-diastolic dimension (23.2 +/- 2.6 vs 25.5 +/- 2.5 mm/M2, p = 0.0001) and lower peak filling rate (4.3 +/- 1.4 vs 5.1 +/- 1.3 stroke counts/s, p = 0.036) than those in New York Heart Association class I. LV end-diastolic diameter was correlated to peak filling rate (r = 0.37; p = 0.008). The most potent predictors of functional limitation were LV end-diastolic dimension (relative risk [RR] 0.63, confidence interval [CI] 0.45 to 0.88; p = 0.008), age (RR 1.09, CI 1.03 to 1.17; p = 0.003), and LV thickness score (RR 1.08, CI 1.02 to 1.13; p = 0.003). LV cavity size was smaller in patients with functional limitation irrespective of obstruction and hypertrophy. Patients with differed from those without a history of syncope for a smaller LV end-diastolic dimension (23.2 +/- 2.5 vs 25.0 +/- 2.7 mm/M2, p = 0.008), which was the only independent predictor of syncope (RR 0.77, CI 0.63 to 0.95; p = 0.013). Thus, a small LV cavity size is associated with functional limitation and history of syncope in HC.

Adolescent

Determinants of aortic artifacts during transesophageal echocardiography of the ascending aorta.

BACKGROUND: The origin of artifacts of the ascending aorta during transesophageal echocardiography has not been widely studied. This study was undertaken to investigate in vivo whether anatomic features could determine the appearance of artifacts. METHODS AND RESULTS: Transesophageal echocardiograms of 46 patients studied for suspected dissection with proven diagnosis (30 patients with and 16 without ascending aortic dissection) were reviewed. The incidence of artifacts was 46%, and it was similar in patients with and those without dissection (chi-square 0.516; P = not significant). Artifacts were located in the aortic lumen twice as far from the transducer as the atrial-aortic interface. The aortic diameter was larger in patients with than in those without artifacts (6.4 +/- 1.1 vs 4.2 +/- 0.9 cm, P <.001). An aortic diameter >5 cm and an atrial-aortic ratio </=0.6 predicted the artifact appearance with good sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy; these parameters reached a value of 100% by analysis only of patients without dissection. CONCLUSIONS: An ascending aortic diameter >5.0 cm that exceeds the left atrial diameter with an atrial-aortic ratio </=0.6 creates in vivo the conditions for the reverberation of the atrial-aortic interface within the aorta. Therefore, in patients with such anatomic features, artifacts must be suspected in the presence of linear structures within the aorta.

Aortic Dissection

Noninvasive evaluation of left ventricular diastolic function in hypertrophic cardiomyopathy.

Diastolic dysfunction is common in hypertrophic cardiomyopathy (HC). Previous studies suggest that Doppler transmitral flow velocity profiles, and the left atrial (LA) M-mode echogram can be used noninvasively to evaluate left ventricular (LV) diastolic function. However, this has not been proved in HC. In this study we determined the relation of Doppler transmitral flow velocity profiles and the LA M-mode echograms to invasive indexes of LV diastolic function in patients with HC. We studied 25 patients with HC, while off drugs, and calculated LA global and active fractional shortening and the slope of both early and late displacement of the posterior aortic wall during LA emptying by M-mode echocardiography. We calculated peak velocity of early (E) and atrial (A) filling, E to A ratio, and E-wave deceleration time by pulsed Doppler echocardiography, and simultaneous radionuclide angiography, LV pressures, time constant of isovolumic relaxation tau, and the constant of chamber stiffness k by cardiac catheterization. The time constant of isovolumic relaxation tau correlated with the slope of early posterior aortic wall displacement (r = 0.59; p <0.01). LV end-diastolic pressure correlated with global LA fractional shortening (r = -0.75; p <0.001); the constant of chamber stiffness k correlated with active LA fractional shortening (r = -0.53; p <0.02). In a subset of 13 patients, in whom echocardiography and cardiac catheterization were performed simultaneously, similar results were found. LA M-mode recordings provide a more reliable noninvasive assessment of diastolic function in HC than mitral Doppler indexes.

Adolescent

Pattern of left ventricular filling in hypertrophic cardiomyopathy. Assessment by Doppler echocardiography and radionuclide angiography.

AIMS: The left ventricle in hypertrophic cardiomyopathy is anatomically and functionally non-uniform. This study was undertaken to verify whether a heterogeneity in the pattern of diastolic filling can be detected along the left ventricular inflow tract in hypertrophic cardiomyopathy. METHODS AND RESULTS: Early (E) and late (A) diastolic velocities were recorded by Doppler echocardiography at mitral and at mid-ventricular level in 16 normal volunteers and 30 patients with hypertrophic cardiomyopathy. Patients with hypertrophic cardiomyopathy also underwent radionuclide angiography to assess left ventricular function. E wave decreased significantly in normal volunteers (80 +/- 15 to 60 +/- 14 cm x s(-1); P<0.001), but it increased in hypertrophic cardiomyopathy (76 +/- 22 to 87 +/- 28 cm x s(-1) P=0.04), whereas the A wave decreased similarly in both. By multivariate analysis, systolic asynchrony and the ejection fraction of left ventricular lateral wall were directly related to the pattern of early filling progression (r=0.656, F=9.467; P<0.002). Moreover, systolic asynchrony showed a univariate direct correlation with changes in E velocity (r=0.42; P=0.02). CONCLUSION: Many patients with hypertrophic cardiomyopathy have an acceleration of filling within the left ventricular inflow tract; this phenomenon is directly related to systolic asynchrony and ejection fraction of the left ventricular lateral wall, suggesting increased suction.

Adolescent

Dual chamber pacing in hypertrophic cardiomyopathy: influence of atrioventricular delay on left ventricular outflow tract obstruction.

The impact of the duration of atrioventricular (AV) delay on obstruction in hypertrophic cardiomyopathy was evaluated in 12 patients by cardiac catheterization, and in 8 of them also by Doppler echocardiography. The AV delay was programmed in random order at 125, 100 and 75 ms in the invasive study and at 120, 100 and 80 ms after pacemaker implantation. The arterial pressure did not changed throughout the studies, whereas the gradient decreased significantly by reducing the AV delay value; the greater gradient reduction was obtained, in both studies, with the AV delay set between 75 or 80 and 100 ms. QRS duration increased significantly by reducing the AV delay during both studies. The widest QRS was not associated with the smallest gradient in all patients. Changes in gradients were similar during the invasive and noninvasive protocols.

Adolescent

Effects of diltiazem on left ventricular systolic and diastolic function in hypertrophic cardiomyopathy.

Hypertrophic cardiomyopathy (HC) is characterized by impaired diastolic function, and left ventricular (LV) outflow tract obstruction in about one-fourth of patients. Verapamil improves diastolic properties, but may have dangerous adverse effects. This study investigates the effects of diltiazem on hemodynamics and LV function in 16 patients with HC who were studied with cardiac catheterization and simultaneous radionuclide angiography. Studies were performed during atrial pacing (15 beats above spontaneous rhythm) at baseline and during intravenous diltiazem administration (0.25 mg x kg(-1) over 2 minutes, and 0.014 mg x kg(-1) x min(-1). Diltiazem induced a systemic vasodilation (cardiac index: 3.4 +/- 1.0 to 4.0 +/- 1.0 L x min(-1) x m(-2), p = 0.003; aortic systolic pressure: 116 +/- 16 to 107 +/- 19 mm Hg, p = 0.007; systemic resistance index: 676 +/- 235 to 532 +/- 193 dynes x s x cm(-5) x m(-2), p = 0.006), not associated with changes in the LV outflow tract gradient. The end-systolic pressure/volume ratio decreased (30 +/- 42 to 21 +/- 29 mm Hg x ml(-1) x m(-2); p = 0.044). Pulmonary artery wedge pressure (11 +/- 5 to 15 +/- 6 mm Hg, p = 0.006), and peak filling rate increased (4.1 +/- 1.3 to 6.0 +/- 2.4 stroke counts x s(-1), p = 0.004). The time constant of isovolumetric relaxation tau decreased (74 +/- 40 to 59 +/- 38 ms, p = 0.045). The constant of LV chamber stiffness did not change. Thus, active diastolic function is improved by the acute administration of diltiazem by both direct action and changes in hemodynamics and loading conditions. LV outflow tract gradient does not increase despite systemic vasodilation. In some patients, however, a marked increase in obstruction and a potentially harmful elevation in pulmonary artery wedge pressure do occur. Passive diastolic function is not affected.

Adult

Normalization of left ventricular nonuniformity late after valve replacement for aortic stenosis.

The aim of the present study was to evaluate nonuniformity in pressure overload hypertrophy due to aortic stenosis. Twenty patients were included in the present analysis. Ten patients with severe aortic stenosis were studied preoperatively as well as early (21 +/- 8 months) and (89 +/- 21 months) after aortic valve replacement (AVR) using left ventricular biplane angiograms, high-fidelity pressure measurements and endomyocardial biopsies. Ten normal subjects served as controls. LV systolic function was assessed from biplane ejection fraction, and diastolic function from the time constant of relaxation, the peak filling rate and the constant of myocardial stiffness. Nonuniformity was evaluated from the coefficient of variation of the time to end-systole (systolic asynchrony) and peak filling rate (diastolic asynchrony) of 12 regions in right anterior oblique and left anterior oblique projection. Ejection fraction was comparable in patients with aortic stenosis and in controls, whereas preoperatively diastolic dysfunction with prolonged relaxation and increased stiffness was present in patients with aortic stenosis and was normalized late after AVR. LV systolic asynchrony was present (>25D of controls) in 7 and diastolic asynchrony in 10 of 10 patients with aortic stenosis. Early as well as late after AVR systolic asynchrony was normalized in 9 of 10 patients. Diastolic asynchrony was present early AVR in all but one patient, although there was a significant improvement with respect to the preoperative evaluation. Late after AVR there was a normalization of diastolic asynchrony in 9 of 10 patients with aortic stenosis. Thus, it is concluded that systolic asynchrony is normalized early after AVR probably due to its load-sensitivity, whereas diastolic asynchrony persists probably due to residual LV hypertrophy with increased interstitial fibrosis and myocardial stiffness. Late after AVR, diastolic asynchrony is normalized due to structural remodeling with regression of both myocardial hypertrophy and interstitial fibrosis.

Aortic Valve

Effects of dual-chamber pacing in hypertrophic cardiomyopathy on left ventricular outflow tract obstruction and on diastolic function.

Hypertrophic cardiomyopathy (HC) is characterized by impaired diastolic function and, in about 1/4 of patients, left ventricular (LV) outflow tract obstruction. Atrioventricular (AV) pacing diminishes LV outflow tract gradient in HC, but impairs diastolic function in the experimental animal and in different categories of patients. To investigate the effects of AV pacing on hemodynamics and LV function in obstructive HC, 16 patients with HC were studied by cardiac catheterization and simultaneous radionuclide angiography during atrial and AV pacing. The resting LV outflow tract gradient decreased with AV pacing from 60 +/- 34 to 38 +/- 37 mm Hg (mean +/- SD; p <0.001). Regional ejection fraction decreased significantly at the septal level from 0.81 +/- 0.21% to 0.69 +/- 0.27% (p <0.01). Pulmonary artery wedge pressure increased from 10 +/- 5 to 15 +/- 6 mm Hg (p <0.001). AV pacing induced asynchrony (i.e., the coefficient of variation of the time to end-systole increased from 7 +/- 4% to 14 +/- 10% (p <0.01). The time constant of isovolumetric relaxation (t) increased from 58 +/- 24 to 74 +/- 33 ms (p <0.02), and peak filling rate decreased from 491 +/- 221 to 416 +/- 184 ml/s (p <0.05). Thus, AV pacing greatly diminishes resting obstruction through a reduction in septal ejection fraction (i.e., an increase in LV outflow tract width in systole), but impairs active diastolic function and increases filling pressures. These latter effects are potentially detrimental in patients with HC in whom diastolic dysfunction is present.

Adult

Recombinant tissue-type plasminogen activator therapy in prosthetic mitral valve thrombosis: assessment by transthoracic and transesophageal echocardiography.

Prosthetic cardiac thrombosis is a life-threatening complication that needs prompt diagnosis and therapy. We used recombinant tissue-type plasminogen activator (rT-PA), followed by heparin, in three patients with mitral prosthetic thrombosis, which was evident in two and suspect in one. Transthoracic and transesophageal echocardiography were employed in the diagnosis of both thrombosis and its resolution. No complications occurred. Immediately after the end of treatment with rT-PA, clinical status and echocardiographic data improved in all cases: transthoracic echocardiography showed the normalization of prosthetic function and transesophageal echocardiography showed resolution of thrombosis. One patient needed reoperation for rethrombosis due to the presence of prosthetic fibrous clot. rT-PA, followed by heparin, led to a good clinical result without bleeding and embolic complications in selected patients with mitral prosthetic thrombosis. Transthoracic and transesophageal echocardiography are complementary diagnostic tools in the diagnosis and management of patients with prosthetic thrombosis.

Adult