PubMed Health⌕ Search

Biomedical subjects

C Burman

Publications and source records attributed to C Burman.

At least 19 recordsLinked to original sources

The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer.

PURPOSE: Conventional radiotherapeutic techniques are associated with lung toxicity that limits the treatment dose. Motion of the tumor during treatment requires the use of large safety margins that affect the feasibility of treatment. To address the control of tumor motion and decrease the volume of normal lung irradiated, we investigated the use of three-dimensional conformal radiation therapy (3D-CRT) in conjunction with the deep inspiration breath-hold (DIBH) technique. METHODS AND MATERIALS: In the DIBH technique, the patient is initially maintained at quiet tidal breathing, followed by a deep inspiration, a deep expiration, a second deep inspiration, and breath-hold. At this point the patient is at approximately 100% vital capacity, and simulation, verification, and treatment take place during this phase of breath-holding. RESULTS: Seven patients have received a total of 164 treatment sessions and have tolerated the technique well. The estimated normal tissue complication probabilities decreased in all patients at their prescribed dose when compared to free breathing. The dose to which patients could be treated with DIBH increased on average from 69.4 Gy to 87.9 Gy, without increasing the risk of toxicity. CONCLUSIONS: The DIBH technique provides an advantage to conventional free-breathing treatment by decreasing lung density, reducing normal safety margins, and enabling more accurate treatment. These improvements contribute to the effective exclusion of normal lung tissue from the high-dose region and permit the use of higher treatment doses without increased risks of toxicity.

Carcinoma, Non-Small-Cell Lung↗

Long term tolerance of high dose three-dimensional conformal radiotherapy in patients with localized prostate carcinoma.

BACKGROUND: The current study was undertaken to evaluate the incidence and predictors of late toxicity in patients with localized prostate carcinoma treated with high dose three-dimensional conformal radiotherapy (3D-CRT). METHODS: A total of 743 patients with prostate carcinoma classified as T1c-T3 were treated with 3D-CRT that targeted the prostate and seminal vesicles. A minimum tumor dose of 64.8 gray (Gy) was given to 96 patients (13%), 70.2 Gy to 266 patients (365), 75.6 Gy to 320 patients (43%), and 81.0 Gy to 61 patients (8%). The median follow-up time was 42 months (range, 18-109 months). Late toxicity was graded according to the Radiation Therapy Oncology Group morbidity scoring scale. RESULTS: Late gastrointestinal (GI) and urinary (GU) toxicities were absent or minimal (Grade 0 or 1) in 90% of patients. The 5-year actuarial likelihood of the development of Grade 2 and 3 late GI toxicities was 11% and 0.75%, respectively. A multivariate analysis identified doses > or =75.6 Gy (P<0.001), history of diabetes mellitus (P = 0.01), and the presence of acute GI symptoms during treatment (P = 0.02) as independent predictors of Grade > or =2 late GI toxicity. The 5-year actuarial likelihood of the development of Grade 2 and 3 late GU toxicities was 10% and 3%, respectively. Doses > or =75.6 Gy (P = 0.008) and acute GU symptoms (P<0.001) were independent predictors of Grade > or =2 late GU toxicity. Among 544 patients who were potent before treatment (73% of all patients), 211 (39%) became impotent after 3D-CRT. The 5-year actuarial risk of potency loss was 60%. Doses > or =75.6 Gy (P<0.001) and the use of neoadjuvant androgen deprivation (P = 0.01) were independent predictors of posttreatment erectile dysfunction. CONCLUSIONS: The incidence of severe late complications after high dose 3D-CRT was minimal. Radiation doses > or =75.6 Gy and the presence of acute treatment-related symptoms during 3D-CRT correlated with a higher incidence of Grade > or =2 late GI and GU toxicities. In addition to higher doses, the use of androgen deprivation therapy increased the likelihood of permanent impotence in these patients. Intensity-modulated radiotherapy, which makes it possible to enhance the conformality of the dose distribution, has recently been implemented in an attempt to reduce the incidence of moderate grade toxicities in patients receiving high dose 3D-CRT.

Adenocarcinoma↗

Locally advanced prostatic cancer: long-term toxicity outcome after three-dimensional conformal radiation therapy--a dose-escalation study.

PURPOSE: To determine the long-term effects of 75.6- and 81.0-Gy doses of three-dimensional conformal radiation therapy in a dose-escalation study in patients with stage T2c-T3 prostatic cancer. MATERIALS AND METHODS: Fifty patients received an initial 75.6-Gy dose, and the dose in 46 patients was subsequently escalated to 81.0-Gy. Median follow-up was 60 and 40 months, respectively. RESULTS: The rates of effects of acute toxicity during the course of treatment were similar for both dose levels. Among the 96 patients, the rate of grade 2 morbidities necessitating medication to relieve acute symptoms was 17% (16 patients) for rectal and 36% (35 patients) for urinary morbidities. All other patients had either no or grade 1 morbidities. Fourteen patients (15%) developed late grade 2 rectal morbidities. There were no differences in 5-year actuarial rates of late grade 2 rectal or urinary morbidities among patients who received 75.6 Gy versus those who received 81.0 Gy. One patient treated with 81.0 Gy developed a grade 3 urethral stricture, which was resolved with dilatation. CONCLUSION: Tumor dose escalation beyond conventional radiation doses for localized prostatic cancer is feasible when delivered with three-dimensional conformal radiation therapy, with no increase in morbidity in normal tissue.

Actuarial Analysis↗

Predictors of improved outcome for patients with localized prostate cancer treated with neoadjuvant androgen ablation therapy and three-dimensional conformal radiotherapy.

PURPOSE: To identify prognostic variables that predict for improved biochemical and local control outcome in patients with localized prostatic cancer treated with neoadjuvant androgen deprivation (NAAD) and three-dimensional conformal radiotherapy (3D-CRT). MATERIALS AND METHODS: Between 1989 and 1995, 213 patients with localized prostate cancer were treated with a 3-month course of NAAD that consisted of leuprolide acetate and flutamide before 3D-CRT. The purpose of NAAD in these patients was to reduce the preradiotherapy target volume so as to decrease the dose delivered to adjacent normal tissues and thereby minimize the risk of morbidity from high-dose radiotherapy. The median pretreatment prostate-specific antigen (PSA) level was 15.3 ng/mL (range, 1 to 560 ng/mL). The median 3D-CRT dose was 75.6 Gy (range, 64.8 to 81 Gy), and the median follow-up time was 3 years (range, 1 to 7 years). RESULTS: The significant predictors for improved outcome as identified in a multivariate analysis included pretreatment PSA level < or = 10.0 ng/mL(P < .00), NAAD-induced preradiotherapy PSA nadir < or = 0.5 ng/mL (P < .001), and clinical stage < or = T2c (P < .04). The 5-year PSA relapse-free survival rates were 93%, 60%, and 40% for patients with pretreatment PSA levels < or = 10 ng/mL, 10 to 20 ng/mL, and greater than 20 ng/mL, respectively (P < .001). Patients with preradiotherapy nadir levels < or = 0.5 ng/mL after 3 months of NAAD experienced a 5-year PSA relapse-free survival rate of 74%, as compared with 40% for patients with higher nadir levels (P < .001). The incidence of a positive biopsy among 34 patients pretreated with androgen ablation was 12%, as compared with 39% for 117 patients treated with 3D-CRT alone who underwent a biopsy (P < .001). CONCLUSION: For patients treated with NAAD and high-dose 3D-CRT, pretreatment PSA, preradiotherapy PSA nadir response, and clinical stage are important predictors of biochemical outcome. Patients with NAAD-induced PSA nadir levels greater than 0.5 ng/mL before radiotherapy are more likely to develop biochemical failure and may benefit from more aggressive therapies.

Aged↗

Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.

PURPOSE: To improve the local control of patients with adenocarcinoma of the prostate we have implemented intensity modulated radiation therapy (IMRT) to deliver a prescribed dose of 81 Gy. This method is based on inverse planning and the use of dynamic multileaf collimators (DMLC). Because IMRT is a new modality, a major emphasis was on the quality assurance of each component of the process and on patient safety. In this article we describe in detail our procedures and quality assurance program. METHODS AND MATERIALS: Using an inverse algorithm, we have developed a treatment plan consisting five intensity-modulated (IM) photon fields that are delivered with DMLC. In the planning stage, the planner specifies the number of beams and their directions, and the desired doses for the target, the normal organs and the "overlap" regions. Then, the inverse algorithm designs intensity profiles that best meet the specified criteria. A second algorithm determines the leaf motion that would produce the designed intensity pattern and produces a DMLC file as input to the MLC control computer. Our quality assurance program for the planning and treatment delivery process includes the following components: 1) verification of the DMLC field boundary on localization port film, 2) verification that the leaf motion of the DMLC file produces the planned dose distribution (with an independent calculation), 3) comparison of dose distribution produced by DMLC in a flat phantom with that calculated by the treatment planning computer for the same experimental condition, 4) comparison of the planned leaf motions with that implemented for the treatment (as recorded on the MLC log files), 5) confirmation of the initial and final positions of the MLC for each field by a record-and-verify system, and 6) in vivo dose measurements. RESULTS: Using a five-field IMRT plan we have customized dose distribution to conform to and deliver 81 Gy to the PTV. In addition, in the overlap regions between the PTV and the rectum, and between the PTV and the bladder, the dose is kept within the tolerance of the respective organs. Our QA checks show acceptable agreement between the planned and the implemented leaf motions. Correspondingly, film and TLD dosimetry indicates that doses delivered agrees with the planned dose to within 2%. As of September 15, 1996, we have treated eight patients to 81 Gy with IMRT. CONCLUSION: For complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose, IMRT provides a powerful and efficient solution. Given a comprehensive and rigorous quality-assurance program, the intensity-modulated fields can be efficaciously and accurately delivered using DMLC. IMRT treatment is now ready for routine implementation on a large scale in our clinic.

Adenocarcinoma↗

Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer.

PURPOSE: Local failure is a major obstacle to the cure of locally advanced non small-cell lung cancer. Three-dimensional conformal radiation therapy (3-DCRT) selects optimal treatment parameters to increase dose to tumor and reduce normal tissue dose, potentially representing an enhancement of the therapeutic ratio of radiation therapy for lung cancer. We performed this analysis of 45 non-small cell lung cancer patients treated with 3-DCRT alone, to evaluate the ability of computer derived lung dose volume histograms to predict serious pulmonary toxicity, to assess the feasibility of this approach, and to examine the resulting survival. METHODS: There were 28 males (62%) and 17 females (38%). The median age was 65 (range: 38-82). Tumor stage was Stage I/II in 13%, IIIa in 42%, and IIIb in 44%. The histology was squamous in 44%, adenocarcinoma in 36%, and other non-small cell histologies in the others. Only 47% of patients. had combined favorable prognostic factors (i.e. KPS < or = 80, and < or = 5% wt. loss). The median dose of radiation to gross disease was 70.2 Gy (range: 52.2-72 Gy) delivered in fractions of 1.8 Gy, 5 days per week. RESULTS: Seven patients did not complete 3-DCRT due to disease progression outside the port. Follow-up data are mature: the median follow up of the 6 survivors is 43.5 months (35-59). Thoracic progression occurred in 46%. Median survival (all 45 patients.) is 15.7 months and survival is 32% at 2 years and 12% at 59 months. Pulmonary toxicity > or = grade 3 occurred in 9% of patients. Dose volume histograms were available in 31 patients and showed a correlation between risk of pulmonary toxicity and indices of dose to lung parenchyma. Grade 3 or higher pulmonary toxicity occurred in 38% (3/8) of patients with > 30% of lung volume receiving > or = 25 Gy, versus 4% (1/23) of patients with < or = 30% lung receiving > or = 25 Gy (P = 0.04). Grade 3 or higher pulmonary toxicity occurred in 29% (4/14) of patients with a predicted pulmonary normal tissue complication probability of 12% or higher versus 0% (0/17) in patients with a predicted probability of less than 12% (P = 0.03). CONCLUSIONS: Despite adverse prognostic criteria median survival is encouraging and may be higher than some combined modality approaches. Dose volume histogram parameters may be useful to determine the maximum dose for individual patients and thereby permit avoidance of toxicity.

Adult↗

Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation.

PURPOSE: To implement radiotherapy with intensity-modulated beams, based on the inverse method of treatment design and using a multileaf collimation system operating in the dynamic mode. METHODS AND MATERIALS: An algorithm, based on the inverse technique, has been integrated into the radiotherapy treatment-planning computer system in our Center. This method of computer-assisted treatment design was used to derive intensity-modulated beams to optimize the boost portion of the treatment plan for a patient with a T1c cancer of the prostate. A dose of 72 Gy (in 40 fractions) was given with a six-field plan, and an additional 9 Gy (in five fractions) with six intensity-modulated beams. The intensity-modulated fields were delivered using dynamic multileaf collimation, that is, individual leaves were in motion during radiation delivery, with the treatment machine operating in the clinical mode. Exhaustive quality assurance measurement and monitoring were carried out to ensure safe and accurate implementation. RESULTS: Dose distribution and dose-volume histogram of the "inverse method" boost plan and of the composite (72 Gy primary + 9 Gy boost) plan were judged clinically acceptable. Compared to a manually designed boost plan, the inverse treatment design gave improved conformality and increased dose homogeneity in the planning target volume. Film and ion chamber dosimetry, performed prior to the first treatment, indicated that each of the six intensity-modulated fields was accurately produced. Thermoluminescent dosimeter (TLD) measurements performed on the patient confirmed that the intended dose was delivered in the treatment. In addition, computer-aided treatment-monitoring programs assured that the multileaf collimator (MLC) position file was executed to the specified precision. In terms of the overall radiation treatment process, there will likely be labor savings in the planning and the treatment phases. CONCLUSIONS: We have placed into clinical use an integrated system of conformal radiation treatment that incorporated the inverse method of treatment design and the use of dynamic multileaf collimation to deliver intensity-modulated beams. The system can provide better treatment design, which can be implemented reliably and safely. We are hopeful that improved treatment efficacy will result.

Humans↗

Three dimensional conformal treatment planning with multileaf collimators.

PURPOSE: Three dimensional conformal radiation treatments are complex, often involving large numbers of blocked or multileaf collimated fields that shape regions of high dose to conform to the treatment volume. As manual definition and digitization of aperture shapes and their corresponding multileaf configurations can be impractically time consuming, it was necessary to integrate the planning of multileaf fields into an existing three dimensional treatment planning system and improve the efficiency of treatment delivery to make these treatments feasible on a routine basis. METHODS AND MATERIALS: A subfunction of the Beam's Eye View (BEV) component can be used to automatically generate a continuous aperture shape with a margin around the tumor to account for beam penumbra, and excluding any normal structures to be spared (each with its own margin). To convert a continuous aperture shape into one defined by the multileaf collimator (MLC), a leaf coverage mode is chosen to determine how leaves are fitted to aperture shapes. The conversion process also considers parameters of the specific MLC system, e.g., leaf thickness and the number of leaves. If normal structures to be shielded split the target into multiple regions, more than one multileaf aperture can result. An interactive leaf adjustment routine is also provided to allow for modification of individual leaf positions. Dose calculation programs then take into account multileaf apertures for computation of dose distributions using a pencil beam convolution model. Finally, prescription files specifying leaf and jaw configurations are prepared in treatment machine specific formats and downloaded to the computers driving the multileaf collimators and other components of the treatment machines. RESULTS AND CONCLUSION: An example is presented of a prostate treatment plan, with MLC configurations, dose distributions, and treatment delivery description, along with discussion of clinical implementation at Memorial Hospital.

Adenocarcinoma↗

Strategy for dose escalation using 3-dimensional conformal radiation therapy for lung cancer.

PURPOSE: Local failure is a major obstacle to the cure of locally advanced non-small-cell lung cancer. 3-Dimensional conformal radiation therapy (3-DCRT) selects optimal treatment parameters to increase dose to tumor and reduce normal tissue dose, potentially permitting dose escalation. There are several ongoing trials of dose escalation using 3-Dimensional conformal radiation therapy for non-small-cell lung cancer. We performed this analysis to determine if data derived from dose volume histograms could be used as the basis for designing the method of dose escalation in these trials. METHODS AND MATERIALS: Between 1990 and 1993, 31 patients were treated with 3-DCRT and had complete normal tissue dose volume histograms created as part of the planning process. The stage distribution was stage I/II 13%, stage IIIa in 45%, and stage IIIb in 42%. The median radiation dose to gross disease was 70.2 Gy (52.2-72 Gy). Elective mediastinal irradiation (50.4 Gy) was administered to 52% (16/31) of patients. RESULTS: The major toxicity encountered in this experience was pulmonary. Dose-volume-histogram data were used to analyze the predictors of toxicity and showed a correlation between risk of pulmonary toxicity and indices of dose to lung parenchyma. Grade 3 or higher pulmonary toxicity occurred in 38% (3/8) of pts with >30%of lung volume receiving > or =25 Gy, versus 4% (1/23) of pts. with < or = 30% lung receiving > or = 25 Gy (p=0.04). Grade 3 or higher pulmonary toxicity occurred in 29% (4/14) of patients with a predicted pulmonary normal tissue complication probability of 12% or higher versus 0% (0/17) in patients with a predicted probability of less than 12% (p=0.03). The single fatality occurred in a patient with a calculated pneumonitis probability of 85% and a high percent (49%) lung volume receiving >= 25 GY. CONCLUSION: This preliminary experience demonstrates a correlation between lung dose-volume-histogram data and the risk of severe pulmonary toxicity. This provides an opportunity to modify the method of radiation dose escalation. Dose-volume-histogram data can allow escalation according to the risk to the lung parenchyma (which is the major organ of concern) rather than escalation according to tumor dose levels. Because of teh major inter-patient variability of intrathoracic tumor bulk and anatomic distribution, this strategy is intuitively appropriate. This approach may facilitate completion of dose escalation studies and identification of maximum tolerable pulmonary dose levels.

Adult↗

Initial clinical experience with computer-controlled conformal radiotherapy of the prostate using a 50-MeV medical microtron.

PURPOSE: We have described previously a model for delivering computer-controlled radiation treatments. We report here on the implementation and first year's clinical experience with such treatments using a 50 MeV medical microtron. METHODS AND MATERIALS: The microtron is equipped with a multileaf collimator and is capable of setting up and treating a sequence of fixed fields called segments, under computer control. An external computer derives machine parameters for the segments from a three-dimensional treatment planning system, transfers them to the microtron control computer, checks the machine settings before allowing dose delivery to begin, and records the treatment. We describe the patient treatment methodology, portal film acquisition, electronic portal imaging, and quality assurance. RESULTS: Patient treatments began in July 1992, comprising six-segment conformal treatments of the prostate. Using the recorded treatment data, the system performance has been examined and compared to other treatment machines. The average treatment time is 10 min, of which 4 min is for computer-controlled setup and irradiation; the remaining time is for patient positioning and checking of clearances. Long-term reproducibility of computer-controlled setup of the gantry and multileaf position is better than 0.5 degrees and 1 mm, respectively. Termination due to a machine fault has occurred in 5.5% of treatments, improving to 2.5% in recent months. CONCLUSION: Our initial experience indicates that computer-controlled segmental therapy can be performed reliably on a routine basis. Treatment times with the microtron are significantly shorter than with conventional linacs, and setup accuracy is consistent with that needed for conformal therapy. We believe that treatment times can be further improved through software upgrades and integration of electronic portal imaging.

Humans↗

The effect of setup uncertainties on the treatment of nasopharynx cancer.

PURPOSE: As radiation treatment techniques become more complicated, the need to understand the effect of uncertainties on dose distributions increases. This study investigates the effect of positional uncertainities for patients with nasopharynx carcinoma treated with a multiple field conformal boost technique. Three dimensional setup errors were measured for six patients and the effect on patient dose was evaluated using dose volume histograms. METHODS AND MATERIALS: A method is presented for determining 3-dimensional translational and rotational setup errors by identifying anatomical landmarks on two treatment field images and their corresponding simulation images. Measurements were made on a daily basis for six patients undergoing conformal treatment. RESULTS: The average magnitude of the translational errors was between 1.5 and 3 mm while the average distance between simulation and treatment isocenters was 5 mm. Both systematic and random setup errors were observed. Dose volume histograms incorporating these uncertainties for standard parallel opposed and conformal techniques were generated for patients experiencing random and systematic setup errors. CONCLUSION: The data imply that positional uncertainties effect the daily dose distributions for target and critical structures differently and that the effect may be treatment technique dependent. These results demonstrate the need to measure setup uncertainties for all sites and to develop techniques for incorporating dose uncertainties in treatment plans.

Calibration↗

Three-dimensional conformal radiation therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancer.

PURPOSE: The specific aim of 3-dimensional conformal radiation therapy is to improve the target dose distribution while concomitantly reducing normal tissue dose. Such an approach should permit dose escalation until the limits of acceptable normal tissue toxicity are reached. To evaluate the feasibility of tumor dose escalation for nine patients with lung cancer, we determined the dose distribution to the target and normal tissues with 3-dimensional conformal radiation therapy and conventional planning. METHODS AND MATERIALS: Plans were compared to assess adequacy of dose delivery to target volumes, dose-volume histograms for normal tissue, and normal tissue complication probabilities (NTCP) for nine patients with lung tumors. RESULTS: The mean percentage of gross disease which received < or = 70.2 Gy with 3-dimensional conformal radiation therapy (3DCRT) was 40% of the mean percentage of gross disease which received < or = 70.2 Gy with conventional treatment planning (CTP). The mean NTCP for lung parenchyma with 3DCRT was 36% of the mean NTCP with CTP. The mean esophageal NTCP with 3DCRT was 88% of the mean NTCP with CTP. CONCLUSION: This preliminary analysis suggests that three dimensional conformal radiation therapy may provide superior delivery of high dose radiation with reduced risk to normal tissue, suggesting that this approach may have the potential to improve the therapeutic ratio of high dose radiation therapy for lung cancer.

Adenocarcinoma↗

Perspectives of multidimensional conformal radiation treatment.

We consider the present technological advancement that underlies the implementation of computer-controlled conformal radiotherapy. We also consider the developments in modern biology that may provide input to therapy planning. The concept of multidimensional conformal radiotherapy is advanced, which integrates geometrical precision and biological conformality, to optimize the treatment planning for individual patients, with a view to improve the overall success of radiotherapy.

Humans↗

Fitting of normal tissue tolerance data to an analytic function.

During external beam radiotherapy, normal tissues are irradiated along with the tumor. Radiation therapists try to minimize the dose of normal tissues while delivering a high dose to the target volume. Often this is difficult and complications arise due to irradiation of normal tissues. These complications depend not only on the dose but also on volume of the organ irradiated. Lyman has suggested a four-parameter empirical model which can be used to represent normal tissue response under conditions of uniform irradiation to whole and partial volumes as a function of the dose and volume irradiated. In this paper, Lyman's model has been applied to a compilation of clinical tolerance data developed by Emami et al. The four parameters to characterize the tissue response have been determined and graphical representations of the derived probability distributions are presented. The model may, therefore, be used to interpolate clinical data to provide estimated normal tissue complication probabilities for any combination of dose and irradiated volume for the normal tissues and end points considered.

Humans↗

Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations.

New tools are needed to help in evaluating 3-D treatment plans because of the large volume of data. One technique which may prove useful is the application of complication probability calculations. A method of calculating complication probabilities for inhomogeneously irradiated normal tissues is presented in this paper. The method uses clinical estimates of tolerance doses for a few discreet conditions of uniform partial organ irradiation, an empirical fit of a continuous function to these data, and a technique (the effective volume method) for transforming nonuniform dose-volume histograms into equivalent uniform histograms. The behavior of the effective volume histogram reduction method for various boundary conditions is reviewed. The use of complication probabilities in evaluating treatment plans is presented, using examples from an NCI 3-D treatment planning contract.

Humans↗

Three-dimensional photon treatment planning for carcinoma of the nasopharynx.

The role of 3-D treatment planning for carcinoma of the nasopharynx was assessed in a four institution study. Two patients were worked up and had an extensive number of CT scans on which target volumes and normal tissues were defined. Treatment planning was then performed using state of the art dose planning systems for these patients to assess the value of the new technology. In general, it was demonstrated that multi-field conformal plans could achieve good tumor dose coverage, while at the same time reducing normal tissue doses, compared to standard treatment planning techniques. The role of inhomogeneity corrections, beam energy, and the use of CT vs. simulation films for defining target volumes were also discussed. In addition, techniques to evaluate 3-D plans for the nasopharynx were considered, and some analysis of this problem is presented in this paper.

Adult↗

Three-dimensional treatment planning for para-aortic node irradiation in patients with cervical cancer.

Three-dimensional treatment planning has been used by four cooperating centers to prepare and analyze multiple treatment plans on two cervix cancer patients. One patient had biopsy-proven and CT-demonstrable metastasis to the para-aortic nodes, while the other was at high risk for metastatic involvement of para-aortic nodes. Volume dose distributions were analyzed, and an attempt was made to define the role of 3-D treatment planning to the para-aortic region, where moderate to high doses (50-66 Gy) are required to sterilize microscopic and gross metastasis. Plans were prepared using the 3-D capabilities for tailoring fields to the target volumes, but using standard field arrangements (3-D standard), and with full utilization of the 3-D capabilities (3-D unconstrained). In some but not all 3-D unconstrained plans, higher doses were delivered to the large nodal volume and to the volume containing gross nodal disease than in plans analyzed but not prepared with full 3-D capability (3-D standard). The small bowel was the major dose limiting organ. Its tolerance would have been exceeded in all plans which prescribed 66 Gy to the gross nodal mass, although some reduction in small bowel near-maximum dose was achieved in the 3-D unconstrained plans. All plans were able to limit doses to other normal organs to tolerance levels or less, with significant reductions seen in doses to spinal cord, kidneys, and large bowel in the 3-D unconstrained plans, as compared to the 3-D standard plans. A high probability of small bowel injury was detected in one of four 3-D standard plans prescribed to receive 50 Gy to the large para-aortic nodal volume; the small bowel dose was reduced to an acceptable level in the corresponding 3-D unconstrained plan. An optimum beam energy for treating this site was not identified, with plans using 4, 6, 10, 15, 18, and 25 MV photons all being equally acceptable. Attempts to deliver moderate or high doses (50-66 Gy) to this region should be made only after careful analysis of the plan with techniques similar to those employed in this study.

Aged↗

Three-dimensional treatment planning considerations for prostate cancer.

Over 300 treatment plans for a total of eight disease sites based on 3-D treatment planning considerations utilizing serial CT delineated target volumes were generated by four institutions as part of an NCI supported contract to both assess the current state-of-the-art capabilities and point directions for future efforts. Two patients with stage C prostate cancer were evaluated with protocol plans which required treatment of the prostate to 70 Gy and the pelvic lymph nodes to 46 Gy. When full 3-D target definition and multiple beam arrangements were employed, all institutions were able to submit plans which scored higher on tumor coverage and had lower normal tissue complication scores compared to traditional plans. The 3-D plans using standard beam arrangements, however, were often rated as highly as the 3-D unconstrained plans due to the multiple beam arrangements already selected to optimize standard plans at most institutions. For this site, heterogeneity corrections, beam energy changes and changes in CT number did not substantially change plan scores.

Aged↗