Balloon dilatation of benign biliary strictures.

Percutaneous transhepatic balloon dilatation of benign postoperative biliary strictures was performed in 6 patients. The procedure was curative in 1 patient. These findings indicate the need for repeated long-term, high-pressure dilatation of these strictures, using an inflation device and pressure gauge. Large catheters should be left in place as stents. Early non-surgical management may improve the salvage rate of this surgical complication.

Adult↗

A new vena caval filter for percutaneous placement and retrieval: experimental study.

A new vena caval filter that can be inserted percutaneously through an angiographic catheter is described. The filter is secured by controlled penetration of the caval wall and is designed for percutaneous retrieval. The filter was easily and safely placed and removed in 11 mongrel dogs, and in an in vitro study, the filter was shown to be highly effective and less dependent than the Greenfield filter on positioning. The authors believe that the filter will be suitable for prophylactic placement in patients at high risk for pulmonary thromboembolic disease.

Animals↗

Failing arteriovenous dialysis fistulas: evaluation and treatment.

A total of 31 patients with 45 episodes of failing arteriovenous dialysis fistulas was studied. Fistula failure was usually due to venous and/or anastomotic stenosis, often in conjunction with thrombosis. Abnormalities were treated by percutaneous dilation and occasionally streptokinase infusion. Most complications and failures occurred either in patients with recently created fistulas or in those with multiple or long segment stenosis associated with thrombosis. Patients with a single nonobstructing stenosis were very successfully treated with percutaneous techniques, which are the treatment of choice for this condition.

Adult↗

A logical approach to renal stone removal.

On the basis of experience with over 350 percutaneous stone extractions, a logical approach assuring a high success rate and minimizing complications is described. The importance of the position of the kidney in the body, the caliceal anatomy, the renal arterial anatomy, and the instrumentation used on puncture site selection are discussed. Strategies for removal of caliceal, pelvic, ureteral, and staghorn calculi, rationale, and treatment of complications are also described.

Humans↗

Percutaneous techniques in the management of urological complications in renal transplant patients.

Obstruction of urine flow and urine leaks are potentially life-threatening complications in renal transplant patients. The diagnosis is difficult, and definite treatment may therefore be delayed. This paper reviews the clinical course of ten renal transplant patients with urologic complications, discusses the limitations of the standard tests used to investigate such problems, and describes the role of percutaneous antegrade pyelography and nephrostomy drainage catheter placement as safe and accurate diagnostic and therapeutic procedures.

Adolescent↗

Hemolytic effect of the Amplatz thrombectomy device.

PURPOSE: The hemolytic effect of the Amplatz thrombectomy device (ATD) was evaluated in nine dogs and in nine patients. MATERIALS AND METHODS: The device was activated for 1-2 minutes in the abdominal aorta, inferior vena cava, or femoral artery of nine dogs. The device was activated for 1-4 minutes in the nine patients in occluded lower extremity bypass grafts (n = 5), native superficial femoral artery (n = 1), a pulmonary artery embolus (n = 1), a portocaval shunt (n = 1), and an iliac vein stent (n = 1). Patients were examined for laboratory evidence of hemolysis following mechanical thrombectomy. RESULTS: In all dogs haptoglobin level decreased, free hemoglobin level in the plasma increased, and hemoglobinuria was present. There was no change in renal function. The level of haptoglobin decreased and the level of plasma free hemoglobin increased in eight patients, with hemoglobinuria detected in one. More hemolysis was observed in the animals than in the patients. CONCLUSION: The ATD has a definite transient hemolytic effect. Until further studied, it should not be used in children and should be used with caution in patients who are anemic, hypoxemic, or have potentially reversible renal insufficiency. Activation time should be monitored closely because hemolysis probably increases with increasing activation time.

Animals↗

Experimental evaluation of a new self-expanding patent ductus arteriosus occluder in a canine model.

PURPOSE: A new self-expanding patent ductus arteriosus (PDA) occluder was designed. MATERIALS AND METHODS: Percutaneous closure of surgically created aortopulmonary shunts was attempted in 19 dogs. The occlusion device consisted of a nitinol wire frame tightly woven into a cylinder with a flat retention disc. A polyester-filled frame was used in the last six procedures. A 6-F introducing sheath was advanced across the aortopulmonary conduit into the descending thoracic aorta. The prosthesis (attached on a stiff delivery cable) was advanced through the introducing sheath. The retention disc was first released in the descending thoracic aorta, then the cylindrical device frame was expanded within the conduit by withdrawing the sheath. RESULTS: Subtotal misplacement into the descending aorta occurred in one procedure (overall technical success rate, 95%), and one animal died before the 1-week follow-up. Complete angiographic shunt closure was achieved in seven of 18 (39%) animals at 30 minutes, 12 of 17 (71%) animals at 1 week, 14 of 17 (82%) animals at 1 month, and 11 of 12 (92%) animals at 3 months. Significantly higher 30-minute closure rates occurred with polyester-filled occluders compared with nonfilled occluders (five of five [100%] vs one of 13 [15%]; P = .002). Persistent shunt at 3 months occurred in only one nonfilled device (6%). In the remaining 16 animals, both orifices of the shunt were covered by a smooth glistening neoendothelium at postmortem examination. CONCLUSION: This device combines the advantages of small delivery system, easy placement, self-centering, and repositionability. Immediate shunt closure can be reliably accomplished with the polyester-filled prosthesis.

Alloys↗

Effect of halothane on systolic time intervals.

By simultaneous rapid-strip recordings of the electrocardiogram, phonocardiogram, and carotid pulse wave, systolic time intervals (STI) can be calculated and used to assess cardiac activity during general anesthesia. The principal advantage of this methodology over more conventional technics of determining anesthetic effects on the heart is that it is noninvasive. One anesthetic agent, halothane, was chosen to illustrate the usefulness of the technic. Results obtained by using STI supported the well-documented effect of myocardial depression produced by halothane. Becuase the equipment and technic are relatively simple, this procedure has definite clinical applications.

Carotid Arteries↗