PubMed Health⌕ Search

Biomedical subjects

C C Kain

Publications and source records attributed to C C Kain.

7 recordsLinked to original sources

Reconstruction of the digital pulley in the monkey using biologic and nonbiologic materials.

A-2 pulleys were replaced in the hand of the nonhuman primate; on the long/little fingers the pulleys were reconstructed with a woven nylon fabric (Nitex), and on the ring/index fingers the pulleys were reconstructed with fascia lata. The opposite unoperated hand served as a control. At 2, 3, and 6 months postoperative, the animals were killed to compare the function of the reconstructed pulleys with the control pulleys of the opposite digit. Using a tensile testing machine, two parameters, work of flexion and tendon excursion, showed that both pulley reconstructions permitted minimal tendon bow-stringing and had excellent gliding function. Both materials increased in strength over time to become stronger than the control pulley. Histologic examination showed no foreign body reaction to the Nitex; excellent fibrous ingrowth into the woven nylon was seen, which matured in time. The surface of the Nitex pulley facing the tendon developed and maintained a synovial-like gliding surface. The Nitex pulley compared favorably with the fascial pulley biomechanically and histologically; both reconstructed pulleys functioned well compared with normal pulleys.

Animals↗

Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standard fixation techniques (interfragmentary cancellous screws or modified tension-band wiring) alone failed after significantly fewer cycles of flexion and extension than did the same fixation when supplemented with a load-sharing cable. In the clinical evaluation of the load-sharing cable, 14 consecutive patients with displaced patellar fractures were treated. No immobilization was used and the patients were started on passive and active range of motion and weight-bearing ambulation in the early postoperative period. Thirteen fractures healed uneventfully. The increased stability of patellar fracture fixation protected with a load-sharing cable offers three advantages: (a) adjunctive casting is unnecessary, (b) comminuted fractures can be "pieced" together anatomically with less concern for loss of fixation, and (c) early postoperative passive and active range of motion can be achieved.

Adolescent↗

Regional differences in matrix formation in the healing flexor tendon.

In 20 white leghorn chickens, the effect of proximity (proximal vs. distal) to the repair site and the effect of sheath excision versus sheath repair on biochemical matrix formation in the healing zone 2 flexor tendon were studied. In 14 animals, the profundus tendon of the long toe on both feet was lacerated and repaired in zone 2. In the right foot, the sheath was repaired, and on the left foot, the sheath was excised. Segments proximal and distal to the laceration site were studied at six weeks postrepair compared to control segments. Sheath excision versus sheath repair had no effect on the net matrix formation of the healing flexor tendon. A higher DNA content and lower hydroxyproline and hexosamine contents were present in the healing tendons, indicating the healing process was not complete at six weeks. Sheath excision versus sheath repair had no effect on net matrix formation in the healing tendon. There is no difference in DNA content or glycosaminoglycan content in the proximal versus distal segments. There was a significantly greater net hydroxyproline content in the proximal segment versus the distal segment of the healing tendon, which was not present in similar control segments. These results support the concept that the zone 2 flexor tendon does not respond to injury as a homogeneous structure.

Animals↗

The effect of vascularization on avian flexor tendon repair. A biochemical study.

Although it has been demonstrated in experimental animals that vascular perfusion functions less effectively than diffusion as a nutrient pathway to the uninjured flexor tendon, it is recognized that the nutritional requirements of an injured flexor tendon may be different. The present study examines several biochemical parameters of avian flexor tendon repair, during a six-week period, in the presence of an intact vinculum longum and with the vinculum longum ligated. Formation of collagen/noncollagen protein, glycosaminoglycan synthesis, and tissue levels of both DNA and hexosamine were quantified. The absence of the vincular blood supply did not affect the levels of total DNA and hexosamine, did not alter the pattern of either protein or glycosaminoglycan formation in the early healing phase, and did not impair the overall synthesis of collagen and noncollagen protein throughout the six-week study period. However, the pattern of collagen and noncollagen protein synthesis differed in lacerated tendons during the period of repair; noncollagen protein synthesis peaked at ten days, while collagen synthesis increased uniformly throughout the 42-day period of study. There was a notable decrease in total matrix hydroxyproline (collagen) during repair, which continued throughout the entire first three weeks after laceration. Thus, the actual percentage of collagen synthesis decreased during the first three weeks of repair and began to return to its normal uninjured level by the sixth week.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Effect of flexor sheath integrity on tendon gliding: a biomechanical and histologic study.

The effect on tendon gliding of flexor sheath excision versus incision/closure following primary flexor tendon repair was examined biomechanically and histologically in forty-one chickens. There was no significant difference in either the tendon excursion required to fully flex the digit or in the work of flexion (the integration of the forces that resist tendon gliding during excursion) between the sheath excised and sheath closed groups. The results were unaffected by postoperative immobilization or intermittent passive motion. Histologically, it was noted that at 3 weeks the healing tendon was surrounded by a layer of granulation tissue that was nearly identical in both the sheath excised and the sheath closed digits. Of note was the finding that a synovial lining could not be identified in those digits that had previously undergone sheath closure. However, at 6 weeks postoperatively, a new gliding surface could be identified surrounding the tendon in both the sheath excised and the sheath closed digits. This study indicates that closure of the flexor sheath after primary tendon repair does not improve tendon gliding as measured biomechanically. Despite its repair, the flexor sheath does not maintain its synovial characteristics as demonstrated histologically, and a new sheath must subsequently be formed.

Animals↗

Development of a synthetic replacement for the flexor tendon pulleys--an experimental study.

A method was developed to reconstruct the fibro-osseous pulleys with Nitex, a synthetic material. Nitex is a closely woven fabric constructed from monofilament nylon fibers. Six adult monkeys (24 digits) had excision of the A1 and A2 pulleys; this was followed by reconstruction of the A2 pulley with the Nitex synthetic material. The animals were killed, two at a time, at 4, 8, and 12 weeks to evaluate the effectiveness of the Nitex pulleys. Flexor tendon function was assessed by biomechanical methods with a tensile testing machine to measure the tendon excursion and the work of flexion (the area under the force-excursion curve) necessary to fully flex each digit; these parameters revealed that the Nitex pulleys were capable of preventing tendon bow-stringing and did not significantly impair tendon gliding. The breaking strength of the Nitex pulleys was comparable to that of normal A2 pulleys (for monkeys weighing less than 10 kg) and it was sufficient to allow immediate mobilization of the digits postoperatively without fear of pulley rupture. Histologic examination showed minimal foreign body reaction around the Nitex, and the gliding surface of a Nitex pulley was found to be covered with a smooth layer of fibrous tissue with minimal adhesions to the underlying flexor tendon. The synthetic Nitex pulley appears to have the potential to function as an effective fibro-osseous pulley replacement.

Animals↗

An in vivo analysis of the effect of transcutaneous electrical stimulation of the quadriceps and hamstrings on anterior cruciate ligament deformation.

Transcutaneous electrical muscle stimulation (TEMS) has been advocated as a method to rehabilitate the postoperative ACL repaired/reconstructed lower extremity. Isolated quadriceps contraction can potentially disrupt the ACL repair/reconstruction; to minimize this risk simultaneous quadriceps and hamstring stimulation has been used. This study measured the in vivo deformation of the ACL during TEMS of the quadriceps and hamstrings. Six legs in four Rhesus monkeys were immobilized in 0 degrees, 45 degrees, and 90 degrees of flexion in neutral rotation using a Hoffman frame and pins placed through the proximal femur and distal tibia. The hamstrings and quadriceps muscles were stimulated with a dual channel electrical stimulator individually and simultaneously at each point of flexion, and ACL deformation was measured using a Hall effect device placed on the anterior medial fibers of the ACL. The following conclusions were made: 1) Isolated quadriceps contraction produces ACL elongation at 0 degrees and 45 degrees of knee flexion and produces ACL shortening at 90 degrees of knee flexion. 2) Isolated hamstrings contraction produces ACL shortening at 45 degrees and 90 degrees of knee flexion and negligible effects at full knee extension. 3) It is not possible to simultaneously contract the quadriceps and hamstrings using separate stimulator pads for each muscle group. 4) At 45 degrees of knee flexion when the quadriceps muscles are stimulated before the hamstring muscles and simultaneous contraction of both is then sustained, ACL lengthening occurs. 5) When the hamstring muscles are fired before the quadriceps muscles and simultaneous contraction of both is sustained, ACL shortening occurs.

Animals↗