Defects in ZnO nanorods prepared by a hydrothermal method.

ZnO nanorod arrays were fabricated using a hydrothermal method. The nanorods were studied by scanning electron microscopy, photoluminescence (PL), time-resolved PL, X-ray photoelectron spectroscopy, and positron annihilation spectroscopy before and after annealing in different environments and at different temperatures. Annealing atmosphere and temperature had significant effects on the PL spectrum, while in all cases the positron diffusion length and PL decay times were increased. We found that, while the defect emission can be significantly reduced by annealing at 200 degrees C, the rods still have large defect concentrations as confirmed by their low positron diffusion length and short PL decay time constants.

Journal Article↗

Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images.

We have evaluated an automated registration procedure for predicting tumor and lung deformation based on CT images of the thorax obtained at different respiration phases. The method uses a viscous fluid model of tissue deformation to map voxels from one CT dataset to another. To validate the deformable matching algorithm we used a respiration-correlated CT protocol to acquire images at different phases of the respiratory cycle for six patients with nonsmall cell lung carcinoma. The position and shape of the deformable gross tumor volumes (GTV) at the end-inhale (EI) phase predicted by the algorithm was compared to those drawn by four observers. To minimize interobserver differences, all observers used the contours drawn by a single observer at end-exhale (EE) phase as a guideline to outline GTV contours at EI. The differences between model-predicted and observer-drawn GTV surfaces at EI, as well as differences between structures delineated by observers at EI (interobserver variations) were evaluated using a contour comparison algorithm written for this purpose, which determined the distance between the two surfaces along different directions. The mean and 90% confidence interval for model-predicted versus observer-drawn GTV surface differences over all patients and all directions were 2.6 and 5.1 mm, respectively, whereas the mean and 90% confidence interval for interobserver differences were 2.1 and 3.7 mm. We have also evaluated the algorithm's ability to predict normal tissue deformations by examining the three-dimensional (3-D) vector displacement of 41 landmarks placed by each observer at bronchial and vascular branch points in the lung between the EE and EI image sets (mean and 90% confidence interval displacements of 11.7 and 25.1 mm, respectively). The mean and 90% confidence interval discrepancy between model-predicted and observer-determined landmark displacements over all patients were 2.9 and 7.3 mm, whereas interobserver discrepancies were 2.8 and 6.0 mm. Paired t tests indicate no significant statistical differences between model predicted and observer drawn structures. We conclude that the accuracy of the algorithm to map lung anatomy in CT images at different respiratory phases is comparable to the variability in manual delineation. This method has therefore the potential for predicting and quantifying respiration-induced tumor motion in the lung.

Algorithms↗

Developments in megavoltage cone beam CT with an amorphous silicon EPID: reduction of exposure and synchronization with respiratory gating.

We have studied the feasibility of a low-dose megavoltage cone beam computed tomography (MV CBCT) system for visualizing the gross tumor volume in respiratory gated radiation treatments of nonsmall-cell lung cancer. The system consists of a commercially available linear accelerator (LINAC), an amorphous silicon electronic portal imaging device, and a respiratory gating system. The gantry movement and beam delivery are controlled using dynamic beam delivery toolbox, a commercial software package for executing scripts to control the LINAC. A specially designed interface box synchronizes the LINAC, image acquisition electronics, and the respiratory gating system. Images are preprocessed to remove artifacts due to detector sag and LINAC output fluctuations. We report on the output, flatness, and symmetry of the images acquired using different imaging parameters. We also examine the quality of three-dimensional (3D) tomographic reconstruction with projection images of anthropomorphic thorax, contrast detail, and motion phantoms. The results show that, with the proper choice of imaging parameters, the flatness and symmetry are reasonably good with as low as three beam pulses per projection image. Resolution of 5% electron density differences is possible in a contrast detail phantom using 100 projections and 30 MU. Synchronization of image acquisition with simulated respiration also eliminated motion artifacts in a moving phantom, demonstrating the system's capability for imaging patients undergoing gated radiation therapy. The acquisition time is limited by the patient's respiration (only one image per breathing cycle) and is under 10 min for a scan of 100 projections. In conclusion, we have developed a MV CBCT system using commercially available components to produce 3D reconstructions, with sufficient contrast resolution for localizing a simulated lung tumor, using a dose comparable to portal imaging.

Artifacts↗

Low energy electron irradiation induced deep level defects in 6H-SiC: the implication for the microstructure of the deep levels E1/E2.

N-type 6H-SiC samples irradiated with electrons having energies of E(e)=0.2, 0.3, 0.5, and 1.7 were studied by deep level transient technique. No deep level was detected at below 0.2 MeV irradiation energy while for E(e)>/=0.3 MeV, deep levels ED1, E(1)/E(2), and E(i) appeared. By considering the minimum energy required to displace the C atom or the Si atom in the SiC lattice, it is concluded that generation of the deep levels E(1)/E(2), as well as ED1 and E(i), involves the displacement of the C atom in the SiC lattice.

Journal Article↗

New radiotherapy technologies.

Conventional radiation therapy has had limited success in curing inoperable lung cancer due to poor local control. There is evidence to suggest that higher doses of radiation will improve local control. In order to safely deliver higher doses of thoracic radiation, advanced treatment techniques are required. Different biologic indices have been utilized to determine whether dose escalation can be safely accomplished, and the results have been reported from many institutions. Tumor motion control aids in treatment since it allows radiation oncologists to more accurately target tumors and therefore to spare more normal tissue from the radiation field. The imaging information from 18-FDG-PET scans also improves target delineation. Advanced treatment delivery techniques, such as three-dimensional conformal radiation therapy, intensity modulated radiation therapy, and stereotactic radiosurgery are also being used to safely escalate the radiation dose. This article explores the current literature on these issues and other advanced radiation therapy techniques.

Dose-Response Relationship, Radiation↗

Studies with cytotoxic agents suggest that apoptosis is not a major determinant of clonogenic death in neuroblastoma cells.

We have previously reported the selection of a radioresistant human neuroblastoma cell line, Clone F, from IMR32 cells. We have shown that clonogenic radioresistance in these cells is accompanied by a reduced level of radiation-induced apoptosis [Cancer Res 55 (1995) 4915]. Here, we measured the response of these lines to several cytotoxic agents, in terms of clonogenicity and apoptosis. In the clonogenic assay, the radioresistant line was also resistant to cisplatin, melphalan and doxorubicin, but not to perillyl alcohol. However, all these agents produced less apoptosis in the Clone F cells, except cisplatin, which failed to induce any apoptosis in either cell line. Reduced apoptosis cannot be the cause of the Clone F cells' resistance to cisplatin. By extension, the Clone F cells' resistance to radiation and other agents cannot be due to diminished apoptosis either. Based on these results, apoptosis may not be a useful surrogate for clonogenic outcome.

Antineoplastic Agents↗

Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning.

We describe a method for generating CT images at multiple respiratory phases with a single spiral CT scan, referred to as respiratory-correlated spiral CT (RCCT). RCCT relies on a respiration wave form supplied by an external patient monitor. During acquisition this wave form is recorded along with the initiation time of the CT scan, so as to "time stamp" each reconstructed slice with the phase of the respiratory cycle. By selecting the appropriate slices, a full CT image set is generated at several phases, typically 7-11 per cycle. The CT parameters are chosen to optimize the temporal resolution while minimizing the spatial gap between slices at successive respiratory cycles. Using a pitch of 0.5, a gantry rotation period of 1.5 s, and a 180 degrees reconstruction algorithm results in approximately 5 mm slice spacing at a given phase for typical respiration periods, and a respiratory motion within each slice that is acceptably small, particularly near end expiration or end inspiration where gated radiotherapy is to occur. We have performed validation measurements on a phantom with a moving sphere designed to simulate respiration-induced tumor motion. RCCT scans of the phantom at respiratory periods of 4, 5, and 6 s show good agreement of the sphere's motion with that observed under fluoroscopic imaging. The positional deviations in the sphere's centroid between RCCT and fluoroscopy are 1.1+/-0.9 mm in the transaxial direction (average over all scans at all phases +/-1 s.d.) and 1.2+/-1.0 mm in the longitudinal direction. Reconstructed volumes match those expected on the basis of stationary-phantom scans to within 5% in all cases. The surface distortions of the reconstructed sphere, as quantified by deviations from a mathematical reference sphere, are similar to those from a stationary phantom scan and are correlated with the speed of the phantom. A RCCT scan of the phantom undergoing irregular motion, demonstrates that successful reconstruction can be achieved even with irregular respiration. Limitations from x-ray tube heating in our current CT unit restrict the length of the scan region to 9 cm for the RCCT settings used, though this will not be a limitation for a multislice scanner. RCCT offers an alternative to the current method of respiration-triggered axial scans. Multiple phases of respiration are imaged with RCCT in approximately the same scanning time required to image a single phase with a triggered axial scan. RCCT scans can be used in connection with respiratory-gated treatment to identify the patient-specific phase of minimum tumor motion, determine residual tumor motion within the gate interval, and compare treatment plans at different phases.

Artifacts↗

A stereotactic method for the three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology, and autoradiography.

The objective of this work was to develop and then validate a stereotactic fiduciary marker system for tumor xenografts in rodents which could be used to co-register magnetic resonance imaging (MRI), PET, tissue histology, autoradiography, and measurements from physiologic probes. A Teflon fiduciary template has been designed which allows the precise insertion of small hollow Teflon rods (0.71 mm diameter) into a tumor. These rods can be visualized by MRI and PET as well as by histology and autoradiography on tissue sections. The methodology has been applied and tested on a rigid phantom, on tissue phantom material, and finally on tumor bearing mice. Image registration has been performed between the MRI and PET images for the rigid Teflon phantom and among MRI, digitized microscopy images of tissue histology, and autoradiograms for both tissue phantom and tumor-bearing mice. A registration accuracy, expressed as the average Euclidean distance between the centers of three fiduciary markers among the registered image sets, of 0.2 +/- 0.06 mm was achieved between MRI and microPET image sets of a rigid Teflon phantom. The fiduciary template allows digitized tissue sections to be co-registered with three-dimensional MRI images with an average accuracy of 0.21 and 0.25 mm for the tissue phantoms and tumor xenografts, respectively. Between histology and autoradiograms, it was 0.19 and 0.21 mm for tissue phantoms and tumor xenografts, respectively. The fiduciary marker system provides a coordinate system with which to correlate information from multiple image types, on a voxel-by-voxel basis, with sub-millimeter accuracy--even among imaging modalities with widely disparate spatial resolution and in the absence of identifiable anatomic landmarks.

Algorithms↗

Using the frame averaging of aS500 EPID for IMRT verification.

In this study, we evaluated the use of aS500 EPID for the verification of IMRT beam delivery, using the synchronous, frame-averaging acquisition. In this approach, an EPID continuously integrates frames while irradiated by an IMRT field; the averaged image is then converted to a dose profile using a linear calibration curve, and is compared with the planned profiles using a linear-regression model, which returns an index sigma (root mean squared error) for the goodness of fit. We identified several potential errors in this acquisition mode: missing data between the start of irradiation and imaging, and from the last (incomplete) frame, which we proved are insignificant for IMRT fields; and EPID dead time during irradiation stemming from data transfer, which we successfully corrected for clinical MU (>100). We compared the measured relative profiles and central axis dose of 25 prostate fields with the planned ones. Applying our correction methods, very good agreement was obtained between the measured and planned profiles with a mean sigma of 1.9% and a standard deviation of 0.5%; for central-axis dose the agreement was better than 2.0%. We conclude that the aS500 is an effective tool for verification of IM beam delivery in the range of clinical MU (>100) settings. Although the vender is developing an upgrade to fix similar problems, our results demonstrate that the current configuration with simple correction schemes can achieve satisfactory results.

Humans↗

Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging.

PURPOSE: To evaluate the effectiveness of a commercial system(1) in reducing respiration-induced treatment uncertainty by gating the radiation delivery. METHODS AND MATERIALS: The gating system considered here measures respiration from the position of a reflective marker on the patient's chest. Respiration-triggered planning CT scans were obtained for 8 patients (4 lung, 4 liver) at the intended phase of respiration (6 at end expiration and 2 at end inspiration). In addition, fluoroscopic movies were recorded simultaneously with the respiratory waveform. During the treatment sessions, gated localization films were used to measure the position of the diaphragm relative to the vertebral bodies, which was compared to the reference digitally reconstructed radiograph derived from the respiration-triggered planning CT. Variability was quantified by the standard deviation about the mean position. We also assessed the interfraction variability of soft tissue structures during gated treatment in 2 patients using an amorphous silicon electronic portal imaging device. RESULTS: The gated localization films revealed an interfraction patient-averaged diaphragm variability of 2.8 +/- 1.0 mm (error bars indicate standard deviation in the patient population). The fluoroscopic data yielded a patient-averaged intrafraction diaphragm variability of 2.6 +/- 1.7 mm. With no gating, this intrafraction excursion became 6.9 +/- 2.1 mm. In gated localization films, the patient-averaged mean displacement of the diaphragm from the planning position was 0.0 +/- 3.9 mm. However, in 4 of the 8 patients, the mean (over localization films) displacement was >4 mm, indicating a systematic displacement in treatment position from the planned one. The position of soft tissue features observed in portal images during gated treatments over several fractions showed a mean variability between 2.6 and 5.7 mm. The intrafraction variability, however, was between 0.6 and 1.4 mm, indicating that most of the variability was due to patient setup errors rather than to respiratory motion. CONCLUSIONS: The gating system evaluated here reduces the intra- and interfraction variability of anatomy due to respiratory motion. However, systematic displacements were observed in some cases between the location of an anatomic feature at simulation and its location during treatment. Frequent monitoring is advisable with film or portal imaging.

Algorithms↗

Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.

Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantification. Motion artifacts lead to two major effects: First, it affects the accuracy of quantitation, producing a reduction of the measured standard uptake value (SUV). Second, the apparent lesion volume is overestimated. Both impact upon the usage of PET images for radiation treatment planning. The first affects the visibility, or contrast, of the lesion. The second results in an increase in the planning target volume, and consequently a greater radiation dose to the normal tissues. One way to compensate for this effect is by applying a multiple-frame capture technique. The PET data are then acquired in synchronization with the respiratory motion. Reduction in smearing due to gating was investigated in both phantoms and patient studies. Phantom studies showed a dependence of the reduction in smearing on the lesion size, the motion amplitude, and the number of bins used for data acquisition. These studies also showed an improvement in the target-to-background ratio, and a more accurate measurement of the SUV. When applied to one patient, respiratory gating showed a 28% reduction in the total lesion volume, and a 56.5% increase in the SUV. This study was conducted as a proof of principle that a gating technique can effectively reduce motion artifacts in PET image acquisition.

Algorithms↗

Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer.

We investigate the potential of megavoltage (MV) cone-beam CT with an amorphous silicon electronic portal imaging device (EPID) as a tool for patient position verification and tumor/organ motion studies in radiation treatment of lung tumors. We acquire 25 to 200 projection images using a 22 x 29 cm EPID. The acquisition is automatic and requires 7 minutes for 100 projections; it can be synchronized with respiratory gating. From these images, volumetric reconstruction is accomplished with a filtered backprojection in the cone-beam geometry. Several important prereconstruction image corrections, such as detector sag, must be applied. Tests with a contrast phantom indicate that differences in electron density of 2% can be detected with 100 projections, 200 cGy total dose. The contrast-to-noise ratio improves as the number of projections is increased. With 50 projections (100 cGy), high contrast objects are visible, and as few as 25 projections yield images with discernible features. We identify a technique of acquiring projection images with conformal beam apertures, shaped by a multileaf collimator, to reduce the dose to surrounding normal tissue. Tests of this technique on an anthropomorphic phantom demonstrate that a gross tumor volume in the lung can be accurately localized in three dimensions with scans using 88 monitor units. As such, conformal megavoltage cone-beam CT can provide three-dimensional imaging of lung tumors and may be used, for example, in verifying respiratory gated treatments.

Algorithms↗

Fitting tumor control probability models to biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer: pitfalls in deducing radiobiologic parameters for tumors from clinical data.

PURPOSE: The goal of tumor control probability (TCP) models is to predict local control for inhomogeneous dose distributions. All existing fits of TCP models to clinical data have utilized summaries of dose distributions (e.g., prescription dose). Ideally, model fits should be based on dose distributions in the tumor, but usually only dose-volume histograms (DVH) of the planning target volume (PTV) are available. We fit TCP models to biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer using either a dose distribution summary or the full DVH in the PTV. We discuss differences in the radiobiologic parameters and dose-response curves and demonstrate pitfalls in interpreting the results. METHODS AND MATERIAL: Two mechanistic TCP models were fit with a maximum likelihood technique to biopsy outcome from 103 prostate patients treated at Memorial Sloan-Kettering Cancer Center. Fits were performed separately for different patient subgroups defined by tumor-related prognostic factors. Fits were based both on full DVHs, denoted TCP(DVH(calc)), and, alternatively, assuming a homogeneous PTV dose given by the mean dose (Dmean) of each DVH, denoted TCP(Dmean(calc)). Dose distributions for these patients were very homogeneous with any cold spots located on the periphery of the PTV. These cold spots were uncorrelated with biopsy outcome, likely because the low-dose regions may not contain tumor cells. Therefore, fits of TCP models that are potentially sensitive to cold spots (e.g., TCP(DVH(calc))) likely give biologic parameters that diminish this sensitivity. In light of this, we examined differences in fitted clonogenic cell number, N(C), or density, rho(C), surviving fraction after 2 Gy, SF(2), or radiosensitivity, alpha, and their standard deviations in the population, sigma(SF(2)) and sigma(alpha), resulting from fits based on TCP(DVH(calc)) and TCP(Dmean(calc)). Dose-response curves for homogeneous irradiation (characterized by TCD(50), the dose for a TCP of 50%) and differences in TCP predictions calculated from the DVH using alternatively derived parameters were evaluated. RESULTS: Fits of TCP(Dmean(calc)) are better (i.e., have larger likelihood) than fits of TCP(DVH(calc)). For TCP(Dmean(calc)) fits, matching values of SF(2) and sigma(SF(2)) (or alpha and sigma(alpha)) exist for all N(C) (rho(C)) above a threshold that give fits of equal quality, with no maximum in likelihood. In contrast, TCP(DVH(calc)) fits have maximum likelihood for high SF(2) (low alpha) values that minimize effects of cold spots. Consequently, small N(C) (rho(C)) values are obtained to match the observed control rate. For example, for patients in low-, intermediate-, and high-risk groups, optimum values of SF(2) and N(C) are 0.771 and 3.3 x 10(3), 0.736 and 2.2 x 10(4), and 0.776 and 1.0 x 10(4), respectively. The TCD(50) of dose-response curves for intermediate-risk patients is 2.6 Gy lower using TCP(DVH(calc)) parameters (TCD(50) = 67.8 Gy) than for TCP(Dmean(calc)) parameters (TCD(50) = 70.4 Gy). TCP predictions calculated from the DVH using risk group-dependent TCP(Dmean(calc)) parameters are up to 53% lower than corresponding calculations with TCP(DVH(calc)) parameters. CONCLUSION: For our data, TCP parameters derived from DVHs likely do not reflect true radiobiologic parameters in the tumor, but are a consequence of the reduced importance of low-dose regions at the periphery of the PTV. Deriving radiobiologic parameters from TCP(Dmean(calc)) fits is not possible unless one parameter is already known. TCP predictions using TCP(DVH(calc)) and TCP(Dmean(calc)) parameters may differ substantially, requiring consistency in the derivation and application of model parameters. The proper derivation of radiobiologic parameters from clinical data requires both substantial dose inhomogeneities and understanding of how these coincide with tumor location.

Adenocarcinoma↗

Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer.

PURPOSE: To implement intensity-modulated radiation therapy (IMRT) for primary nasopharynx cancer and to compare this technique with conventional treatment methods. METHODS AND MATERIALS: Between May 1998 and June 2000, 23 patients with primary nasopharynx cancer were treated with IMRT delivered with dynamic multileaf collimation. Treatments were designed using an inverse planning algorithm, which accepts dose and dose-volume constraints for targets and normal structures. The IMRT plan was compared with a traditional plan consisting of phased lateral fields and a three-dimensional (3D) plan consisting of a combination of lateral fields and a 3D conformal plan. RESULTS: Mean planning target volume (PTV) dose increased from 67.9 Gy with the traditional plan, to 74.6 Gy and 77.3 Gy with the 3D and IMRT plans, respectively. PTV coverage improved in the parapharyngeal region, the skull base, and the medial aspects of the nodal volumes using IMRT and doses to all normal structures decreased compared to the other treatment approaches. Average maximum cord dose decreased from 49 Gy with the traditional plan, to 44 Gy with the 3D plan and 34.5 Gy with IMRT. With the IMRT plan, the volume of mandible and temporal lobes receiving more than 60 Gy decreased by 10-15% compared to the traditional and 3D plans. The mean parotid gland dose decreased with IMRT, although it was not low enough to preserve salivary function. CONCLUSION: Lower normal tissue doses and improved target coverage, primarily in the retropharynx, skull base, and nodal regions, were achieved using IMRT. IMRT could potentially improve locoregional control and toxicity at current dose levels or facilitate dose escalation to further enhance locoregional control.

Algorithms↗

Late rectal bleeding after conformal radiotherapy of prostate cancer. II. Volume effects and dose-volume histograms.

PURPOSE AND OBJECTIVE: Late rectal bleeding is a potentially dose limiting complication of three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. The frequency of late rectal bleeding has been shown to increase as the prescription dose rises above 70 Gy. The purpose of this study is to identify features of the cumulative dose-volume histogram (DVH) for the rectal wall that correlate with late rectal bleeding after 3D-CRT for prostate cancer. METHODS AND MATERIALS: Follow-up information on rectal bleeding is available for 261 and 315 patients treated using 3D-CRT at Memorial Sloan-Kettering Cancer Center for Stage T1c-T3 prostate cancer with minimum target doses of 70.2 and 75.6 Gy, respectively. All patients in this study were treated with a coplanar 6-field technique (2 lateral and 4 oblique fields). Patients were classified as having rectal bleeding if they bled (> or = Grade 2) before 30 months, and nonbleeding (< or = Grade 1) if they were without bleeding at 30 months, using the RTOG morbidity scale. Rectal bleeding was observed in 13 and 38 of the patients treated at 70.2 and 75.6 Gy, respectively. Treatment plans were analyzed for 39 nonbleeding and 13 bleeding patients receiving 70.2 Gy, and 83 nonbleeding and 36 bleeding patients receiving 75.6 Gy. Dose-volume histograms (DVHs) for the anatomic rectal wall were calculated. Average DVHs of the bleeding and nonbleeding patients were generated, and a permutation test was used to assess the significance of differences between them, for each dose group. The confounding effect of total rectal wall volume (V(RW)) was removed by calculating the average differences in DVHs between all combinations of bleeding and nonbleeding patients with similar V(RW)s. Finally, multivariate analysis using logistic regression was performed to test the significance of the DVH variables in the presence of anatomic, geometric, and medical variables previously found to correlate with rectal bleeding in a companion analysis of the same patients. RESULTS: The area under the average percent volume DVH for the rectal wall of patients with bleeding was significantly higher than those of patients without bleeding in both dose groups (p = 0.02, 70.2 Gy; p < 0.0001, 75.6 Gy). However, small V(RW)s were associated with rectal bleeding (p = 0.06, 70.2 Gy; p < 0.01, 75.6 Gy), resulting in an increase in average percent volumes exposed to all doses for patients with rectal bleeding. For patients with similar V(RW)s, rectal bleeding was significantly correlated with the volumes exposed to 46 Gy in both dose groups (p = 0.02, 70.2 Gy; p = 0.005, 75.6 Gy, tolerance in V(RW): 5 ccs). For the 75.6 Gy dose group, the percent volume receiving 77 Gy was significantly correlated with rectal bleeding (p < 0.005). Bivariate analysis using logistic regression, including V(RW) together with a single DVH variable, showed good agreement with the above analysis. Multivariate analysis revealed a borderline significant correlation of the percent volume receiving 71 Gy in the 70.2 Gy dose group. It also showed that the DVH variables were highly correlated with geometric and dosimetric variables previously found to correlate with rectal bleeding in multivariate analysis. CONCLUSION: Significant volume effects were found in the probability of late rectal bleeding for patients undergoing 3D-CRT for prostate cancer with prescription doses of 70.2 and 75.6 Gy. The percent volumes exposed to 71 and 77 Gy in the 70.2 and 75.6 Gy dose groups respectively were significantly correlated with rectal bleeding. The independent correlation of small V(RW) with rectal bleeding may indicate the existence of a functional reserve for the rectum. The independent association with larger percent volumes exposed to intermediate doses ( approximately 46 Gy) seen in both dose groups may indicate that a large surrounding region of intermediate dose may interfere with the ability to repair the effects of a central high dose region.

Algorithms↗

Developments in nuclear magnetic resonance imaging and spectroscopy: application to radiation oncology.

Nuclear magnetic resonance techniques have advanced to the point where functional, physiologic, and biochemical information may be obtained from patients. Magnetic resonance imaging of tissue water can be used to measure perfusion and diffusion with submillimeter resolution. Magnetic resonance spectroscopy may be applied to the assessment of tissue metabolites that contain protons, phosphorus, fluorine, or other nuclei. The combination of imaging and spectroscopy technologies has lead to spectroscopic imaging techniques that are capable of mapping proton metabolites at resolutions as small as 0.25 cm(3) within the time constraints of a clinical imaging study. This article provides a brief review of magnetic resonance techniques for imaging of tissue physiological function and addresses possible applications in the realm of radiation oncology.

Animals↗

Smoothing intensity-modulated beam profiles to improve the efficiency of delivery.

Intensity-modulated beam profiles are generated by an inverse planning or optimization algorithm, a process that, being computationally complex and intensive, is inherently susceptible to noise and numerical artifacts. These artifacts make delivery of the beams more difficult, oftentimes for little, if any, observable improvement in the dose distributions. In this work we examine two approaches for smoothing the beam profiles. The first approach is to smooth the beam profiles subsequent to each iteration in the optimization process (method A). The second approach is to include a term within the objective function that specifies the smoothness of the profiles as an optimization criterion (method B). The two methods were applied to a phantom study as well as three clinical sites: paraspinal, nasopharynx, and prostate. For the paraspinal and nasopharynx cases, which have critical organs with low tolerance doses in close proximity, method B produced sharper dose gradients, better target dose homogeneity, and more critical organ sparing. In the less demanding prostate case, the two methods give similar results. In addition, method B is more efficient during optimization, requiring fewer iterations, but less efficient during DMLC delivery, requiring a longer beam-on time.

Algorithms↗