PubMed Health⌕ Search

Biomedical subjects

C C Rowe

Publications and source records attributed to C C Rowe.

16 recordsLinked to original sources

Imaginem oblivionis: the prospects of neuroimaging for early detection of Alzheimer's disease.

Alzheimer's disease (AD) is a progressive neurodegenerative disorder characterised by the gradual onset of dementia. The pathological hallmarks of the disease are A beta amyloid plaques, neurofibrillary tangles, and reactive gliosis. Current diagnosis of AD is made by clinical, neuropsychologic, and neuroimaging assessments. Routine structural neuroimaging evaluation is based on non-specific features such as atrophy, a late feature in the progression of the disease, hence the crucial importance of developing new approaches for early and specific recognition at the prodromal stages of AD. Functional neuroimaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) could prove to be valuable in the differential diagnosis of AD, as well as in assessing prognosis. With the advent of new therapeutic strategies aimed at reducing the A beta amyloid burden in the brain, there is increasing interest in the development of PET and SPECT radioligands that will permit the assessment of A beta amyloid burden in vivo. From this, the prospect of specific preclinical diagnosis arises, possibly in conjunction with other related A beta biomarkers in plasma and CSF.

Alzheimer Disease↗

Reduced posterior cingulate binding of I-123 iodo-dexetimide to muscarinic receptors in mild Alzheimer's disease.

Early detection of Alzheimer's disease (AD) allows timely pharmacological and social interventions. Alteration in muscarinic receptor binding was evaluated with I-123 iodo-dexetimide (IDEX) in early clinical stage AD. We studied 11 mild AD patients (Folstein Minimental State Examination Score 24-27, Clinical Dementia Rating 0.5-1.0) and 10 age- and sex-matched normal subjects with SPECT brain imaging after injection of 185 MBq of IDEX and 750 MBq of 99mTc-HMPAO. Using a voxel based approach (Statistical Parametric Mapping (SPM99) software), a deficit in IDEX binding was found in the posterior cingulate cortex in the mild AD group with p (corrected)=0.06 for the most significant voxel and p=0.0003 for the voxel cluster. Region of interest (ROI) analysis confirmed the SPM99 results. SPM99 found no deficit in the HMPAO scans, suggesting that neither atrophy nor hypoperfusion were major factors in the reduced IDEX binding. This study provides further evidence of the involvement of the posterior cingulate region and of muscarinic receptors in early Alzheimer's disease and suggests that this change may precede an alteration in blood flow.

Alzheimer Disease↗

Rare genetically defined causes of dementia.

Several genetic disorders, though rare, are associated or present with dementia. Developments in the field of genetics are contributing to clarify and expand our knowledge of the complex physiopathological mechanisms leading to neurodegeneration and cognitive decline. Disorders associated with misfolded and aggregated proteins and lipid, metal or energy metabolism are examples of the multifarious disease processes converging in the clinical features of dementia, either as its predominant feature, as in cases of Alzheimer's disease (AD) or frontotemporal dementia (FTD), or as part of a cohort of accompanying or late-developing symptoms, as in Parkinson's disease (PD) or amyotrophic lateral sclerosis with dementia (ALS-D). Awareness of these disorders, allied with recent advances in genetic, biochemical and neuroimaging techniques, may lead to early diagnosis, successful treatment and better prognosis.

Amyotrophic Lateral Sclerosis↗

SPECT brain imaging in epilepsy: a meta-analysis.

UNLABELLED: A meta-analysis of SPECT brain imaging in epilepsy was performed to derive the sensitivity and specificity of interictal, postictal or ictal rCBF patterns to identify a seizure focus in medically refractory patients. METHODS: Papers were obtained by pooling all published articles identified by two independent literature searches: (a) Dialnet (EMBASE) or Radline by CD-ROM and (b) Current Contents searched manually. Literature inclusion criteria were: (a) patients had a localization-related epileptic syndrome; (b) more than six patients were reported; and (c) patients had at least an interictal EEG-documented epileptiform abnormality. Of 46 papers meeting these criteria, 30 contained extractable data. SPECT results were compared to localization by standard diagnostic evaluation and surgical outcome. Meta-analytic sensitivities for SPECT localization in patients with temporal lobe seizures relative to diagnostic evaluation were 0.44 (interictal), 0.75 (postictal) and 0.97 (ictal). Similar results were obtained relative to surgical outcome. False-positive rates were low relative to diagnostic evaluation (7.4% for interictal and 1.5% for postictal studies) and surgical outcome (4.4% for interictal and 0.0% for postictal studies). RESULTS: The results were not dependent on tracer used (or dose), the presence of CT-identified structural abnormalities, blinding of image interpretation or camera quality (although data were more variable with low-resolution cameras). There were insufficient data for conclusions regarding extratemporal-seizure or pediatric epilepsy populations. CONCLUSION: Insights gained from reviewing this literature yielded recommendations for minimal information that should be provided in future reports. Additional recommendations regarding the nature and focus of future studies also are provided. The most important of these is that institutions using SPECT imaging in epilepsy should perform ictal, preferably, or postictal scanning in combination with interictal scanning.

Brain↗

Simultaneous emission transmission tomography using technetium-99m for both emission and transmission.

This phantom study investigates whether attenuation maps from transmission data degraded by increased noise from subtraction of emission counts can still provide useful attenuation correction in the regular and obese chest. Technetium-99m was used for both emission and transmission on a triple head simultaneous emission transmission tomography (Tc-Tc SETT) system. Fanbeam transmission counts were computed by subtracting emission counts estimated from the two parallel collimator heads. Radioactive decay was used to simulate organ counts from injections of 900 and 400 MBq sestamibi for regular and obese chest sizes. Line source activity was 350 MBq. Control attenuation maps were obtained with no emission activity. Noise control included catering for negative and zero transmission counts, pre-filtering and segmentation of mu maps. Pre-filtering was tried before and after subtraction and before and after setting negative pixels to zero. Mean+/-SD count/pixel at the heart in anterior transmission projections was typically 33+/-18 for the regular and 1+/-7 for the obese chest. For the obese chest, pre-filtering before resetting negative counts best preserved mean mu in soft tissue and lung. Tc-Tc SETT mu mean+/-SD for the regular chest were 0.144+/-0.012 and 0.058+/-0.004 for soft tissue and lung and for the obese chest, 0.152+/-0.075 and 0.059+/-0.017. The accuracy of the Tc-Tc SETT bullseye plots for the regular chest was the same as with control map attenuation correction and 3 times better than with no correction. For the obese chest it was as good as with control map correction only if mu map segmentation was applied. Tc-Tc SETT soft tissue and lung mu in 28 patient studies indicated that segmentation is practical for a wide range of chest sizes. Tc-Tc SETT on a triple-head system offers an accurate, inexpensive method of attenuation correction for the majority of chest sizes.

Humans↗

Localization of temporal lobe epileptic foci with iodine-123 iododexetimide cholinergic neuroreceptor single-photon emission computed tomography.

There is evidence suggesting that muscarinic cholinergic neuroreceptors (mChR) are reduced at seizure foci. Iodine-123 (I-123) iododexetimide (IDEX) single-photon emission computed tomography (SPECT) permits in vivo imaging of mChR. We assessed 23 patients with temporal lobe epilepsy (TLE) undergoing preoperative assessment. Regions of interest were placed over the amygdala, hippocampus, and lateral temporal cortex on IDEX SPECT images. Eighteen patients had unilateral TLE. In these, IDEX binding in the ipsilateral hippocampal region was reduced by 19.1 +/- 12%. This was significantly greater than blood flow asymmetry (p < 0.02 by Wilcoxon's signed-rank test). Changes were less marked in the amygdala (11.3 +/- 6.4%) and lateral cortex (7.6 +/- 12.1%). Blinded visual analysis gave correct localization in 14 (78%) patients, and hexamethylpropylenamine oxide (HMPAO) SPECT gave correct localization in 50%. MRI revealed hippocampal sclerosis in 13 (72%) patients and was normal in 5 patients. Of the latter group, four were correctly localized by IDEX. This study confirms that mChR receptors are altered in medial temporal lobe structures in TLE. IDEX SPECT appears to be superior to interictal HMPAO SPECT and complimentary to MRI for seizure focus localization.

Adult↗

SPECT in the localisation of extratemporal and temporal seizure foci.

The yield of ictal, postictal, and interictal SPECT was compared in the localisation of seizure foci in 177 patients with partial epilepsy. In 119 patients with known unilateral temporal lobe epilepsy ictal SPECT (97% correct localisation) was superior to postictal SPECT (71% correct), which was better than interictal studies (48% correct). Similarly, in cases of known or suspected extratemporal epilepsy the yield of ictal SPECT studies was high (92%). By contrast, the yield of postictal studies was much lower (46%) and usually only very early postictal studies were diagnostic. Interictal SPECT was of little value. The accuracy of ictal SPECT in localising temporal lobe seizures is now well established. Extratemporal seizures are often brief and difficult to localise. This report shows that ictal SPECT also has a high diagnostic yield in a wide range of extratemporal epilepsies. The brevity of many extratemporal seizures means that true ictal SPECT examinations can be difficult to achieve, but the high diagnostic yield justifies the special organisational effort needed to obtain such studies.

Epilepsies, Partial↗

Human dosimetry and biodistribution of iodine-123-iododexetimide: a SPECT imaging agent for cholinergic muscarinic neuroreceptors.

UNLABELLED: Iodine-123-iododexetimide (IDEX) has recently been used for SPECT imaging of muscarinic cholinergic neuroreceptors (mAChR) in humans. We report the human radiation dosimetry, whole-body and normal cerebral distribution of IDEX. METHODS: Serial whole-body planar and brain SPECT scans were performed over 24 hr in four normal subjects. Organ activity was calculated from attenuation-corrected geometric mean counts from ROIs drawn over visible organs. Thigh activity was used for background subtraction. Organ absorbed doses and effective dose were calculated using the MIRD schema. Brain SPECT was performed 6 hr postinjection in ten normal subjects. ROIs placed over cortical and subcortical structures were used to determine brain distribution. RESULTS: The effective dose was 24.7 microSv/MBq. An average of 54% of IDEX remained in the body background. Decay-corrected brain uptake was 6.9% of injected dose at 1 hr, 8.6% at 6 hr and 8.1% at 24 hr. Regional brain distribution showed high uptake in striatum and cortex with low activity in thalamus and cerebellum. At 6 hr, activity relative to striatum was 70% for frontal and parietal cortex, 102% for occipital cortex, 54% for thalamus and 11% for cerebellum. CONCLUSION: Iodine-123-IDEX produced high quality SPECT images with activity at 6 hr reflecting the known distribution of mAChR receptors. The favorable dosimetry of IDEX and high synthetic yield (50%-70%) suggest it to be a suitable agent for clinical studies.

Aged↗

Ictal postictal and interictal single-photon emission tomography in the lateralization of temporal lobe epilepsy.

Single-photon emission tomography (SPET) using radioligands that are fixed on first pass through the cerebral circulation shows distinctive and rapidly changing blood flow patterns accompanying temporal lobe seizures. We sought to determine the optimal time to perform SPET studies for clinical seizure lateralization in temporal lobe epilepsy. Interictal, ictal and postictal SPET scans of 73 consecutively studied patients with unilateral temporal lobe epilepsy were read by three blinded observers to assess the accuracy of lateralization in each condition. The blinded observers correctly identified the side of focus in 97% of ictal studies, 72% of postictal studies and 50% of interictal studies. No incorrect scores were made in the ictal studies, whilst 5% of postictal and 12% of interictal studies were lateralized to the wrong side. Inter-observer agreement was best with the ictal studies. The dramatic perfusion changes of ictal SPET provide consistent, reliable and easily interpretable information that is superior to that provided by interictal and postictal studies. Injection of ligand during seizures is therefore the method of choice for SPET to aid the non-invasive lateralization of temporal seizure foci.

Adult↗

Ictal SPECT using technetium-99m-HMPAO: methods for rapid preparation and optimal deployment of tracer during spontaneous seizures.

Ictal SPECT provides unique information for the clinician treating patients with refractory epilepsy and reveals insights into the pathophysiology of seizures. We describe our methods for the routine attainment of ictal images using 99mTc-HMPAO. We have devised and implemented techniques for rapid reconstitution of 99mTc-HMPAO adjacent to the video-EEG monitoring suite such that the tracer can be rapidly injected into patients when spontaneous seizures occur. Our quality assurance data show that this can be done safely outside a nuclear medicine department. The clinical results in patients with temporal lobe epilepsy show that ictal injections (97% correct lateralization of focus, 0% incorrect) are more sensitive and accurate compared to interictal studies (48% correct, 10% incorrect), demonstrating that the implementation of these techniques is worthwhile.

Brain↗

Postictal switch in blood flow distribution and temporal lobe seizures.

The ictal increase of regional cerebral blood flow has yet to be fully utilised in the investigation of focal seizures. Although single photon emission tomography (SPECT) is being increasingly used in the localisation of epileptic foci, the evolution and time courses of the peri-ictal perfusion changes have yet to be clarified. We performed serial SPECT studies in the interictal, ictal and immediate postictal states in 12 patients with refractory temporal lobe epilepsy to define the patterns and duration of peri-ictal cerebral blood flow changes. Visual analysis showed a constant pattern of unilateral global increases in temporal lobe perfusion during seizures which suddenly switched to a pattern of relative mesial temporal (hippocampal) hyperperfusion and lateral temporal hypoperfusion in the immediate postictal period. Quantitative analysis confirmed the visual assessment. Lateral temporal cortex ictal/normal side to side ratios were increased by mean 35.1% (95% confidence interval 21.8% to 48.4%) more in the ictal studies than in the interictal studies and mesial temporal cortex ratios increased by mean 30.8% (22.4% to 39.2%). In the postictal state, however, lateral temporal ratios were reduced by mean 7.7% (-15.8% to 0.4%) compared with interictal values, whereas mesial temporal perfusion was maintained compared with the interictal studies. These observations provide critical information for interpreting scans which can be used in the localisation of epileptic foci. This postictal switch in blood flow patterns may reflect the underlying metabolic processes of neuronal activation and recovery and have implications for understanding the neurobiology of human epileptic seizures.

Basal Ganglia↗

Patterns of postictal cerebral blood flow in temporal lobe epilepsy: qualitative and quantitative analysis.

We used single-photon emission computed tomography (SPECT) to study postictal cerebral blood flow (CBF) in 51 patients with temporal lobe epilepsy. There were 78 seizures studied, 77 by early postictal injection of Tc-99m HMPAO (delay from seizure onset = 4.3 +/- 4.5 min) and one by ictal injection. Increased focal temporal lobe uptake, predominantly confined to the anteromesial region, was present in 83% and declined rapidly over 5 minutes. Reduced activity in the lateral temporal lobe accompanied the mesial increase in 80% of studies, extending over much of the ipsilateral hemisphere and closely associated with the degree and extent of postictal EEG slow waves. These patterns enabled correct seizure localization by blinded analysis in 69% (31/45) of the patients with a unilateral EEG focus. The remainder showed bilateral or no changes. One of six patients with bitemporal EEG foci had unilateral perfusion changes. The positive predictive value for the correct localization of a unilateral focus by postictal SPECT was 97% (31/32). Postictal CBF imaging with SPECT can be used to support noninvasive electrographic localization and may decrease the need for invasive electrode studies.

Adult↗

Visual and quantitative analysis of interictal SPECT with technetium-99m-HMPAO in temporal lobe epilepsy.

Interictal 99mTc-HMPAO SPECT images were compared to ictal EEG localization in 51 patients with intractable temporal lobe epilepsy to determine their usefulness for preoperative seizure focus localization. Both quantified temporal lobe asymmetry and blinded visual detection of temporal lobe hypoperfusion were employed. Visual analysis detected ipsilateral hypoperfusion in 18 (39%) of the 46 patients with a unilateral focus and contralateral hypoperfusion in 3. None of the five patients with bitemporal foci had unilateral hypoperfusion. The positive predictive value of unilateral temporal lobe hypoperfusion was 86% (18/21). Quantified anterior temporal lobe asymmetry, greater than a previously derived normal range, correctly identified the focus in 22 (48%) but gave the wrong side in 5, resulting in a predictive value of 81%. The degree of asymmetry correlated inversely with age of seizure onset, but not with other clinical parameters, histology, or verbal and nonverbal memory. The usefulness of interictal 99mTc-HMPAO SPECT for pre-operative seizure focus localization is limited by low sensitivity when performed with a conventional rotating gamma camera. This suggests that ictal or immediate postictal imaging may be necessary for this purpose.

Adult↗

Localization of epileptic foci with postictal single photon emission computed tomography.

Effective surgical treatment of patients with intractable complex partial seizures depends on accurate preoperative seizure focus localization. We evaluated seizure localization with interictal and immediate postictal single photon emission computed tomographic images of cerebral perfusion using technetium-99m-hexamethyl-propyleneamineoxime (99mTc-HMPAO) in comparison with conventional ictal electroencephalographic (EEG) localization. Thirty-two patients with intractable complex partial seizures were studied. The mean delay from seizure onset to injection was 6.3 +/- 5.3 (SD) minutes. Independent blinded observers assessed the scans for interictal hypoperfusion and postictal focal hyperperfusion. Interictal scans alone were unreliable, indicating the correct localization in 17 patients (53%) and an incorrect site in 3 (9%). When interictal and postictal scans were interpreted together, the focus was correctly localized in 23 patients (72%). There was 1 false-positive study, and 8 patients had inconclusive changes, including 2 with inconclusive depth EEG studies. Postictal hyperperfusion was predominantly mesial temporal and frequently associated with hypoperfusion of lateral temporal cortex. Secondarily generalized seizures tended to show focal hyperperfusion less often than complex partial seizures did (Fisher's exact test p = 0.09). Combined interictal and immediate postictal single photon emission computed tomography with 99mTc-HMPAO is a useful noninvasive technique for independent confirmation of electrographic seizure localization. It may provide a suitable alternative to the use of depth electrode studies for confirmation of surface EEG findings in many patients with complex partial seizures.

Adolescent↗