PubMed Health⌕ Search

Biomedical subjects

C C Watson

Publications and source records attributed to C C Watson.

7 recordsLinked to original sources

Effect of 176Lu background on singles transmission for LSO-based PET cameras.

We explore how the radioactive background from naturally occurring 176Lu affects single photon transmission imaging for lutetium orthosilicate (LSO) scintillator-based PET cameras by estimating the transmission noise equivalent count rate (NECR) including this background. Assuming a typical PET camera geometry (80 cm detector ring diameter), we use a combination of measurement and analytic computation to estimate the counting rates due to transmission, scatter and background events as a function of singles transmission source strength. We then compute a NECR for singles transmission. We find that the presence of radiation from the naturally occurring 176Lu reduces the NECR by 60% or higher for source strengths less than 10 mCi, and that a 25% reduction of the NECR can occur even with a source strength of 40 mCi.

Humans↗

Expression of human complement receptor 2 (CR2, CD21) in Cr2-/- mice restores humoral immune function.

Complement receptor type 2 (CR2, CD21) is expressed by both human and murine B cells and has been demonstrated to play a pivotal role in the humoral immune response. We have reconstituted Cr2-/- mice with an 80-kb human genomic fragment (designated P1-5) containing the full-length human CR2 (hCR2) gene. Transfection of P1-5 into the mouse A20 B cell line confirmed that it would direct expression of the hCR2 protein in mouse B cells. Immunoprecipitation analysis in these cells revealed that hCR2 coassociates with mouse CD19. After creation of transgenic mice using P1-5, we found significant expression of hCR2 on peripheral blood and splenic B cells by flow cytometric analysis. RT-PCR analysis of tissues and purified cell populations from transgene-positive mice revealed that hCR2 expression was restricted to B cells and the spleen in a pattern that matches mouse CR2. To rigorously assess the functional capabilities of hCR2, the transgene was bred onto Cr2-/- mice, which have a notable defect in response to SRBC Ag. We found that Cr2-/- mice expressing hCR2 had a substantial restoration of the humoral immune response to SRBC as compared with nontransgenic Cr2-/- littermate controls. Overall, this study suggests that hCR2 is able to substitute for mouse CR2 in the murine immune system. Therefore, hCR2-transgenic mice offer a valuable model system to further examine immunologic roles as well as structure-function relationships important for hCR2 function in primary cells in vivo.

Animals↗

[Experimental determination of the lower energy discriminator level of positron emission tomographs].

AIM: Using the continuous energy spectra of Compton scattered photons we measured the lower energy discriminator level of a positron emission tomograph (PET). METHODS: In PET scans, coincident photons with an energy between the lower and upper level of the energy discriminator (LLD/ULD) are acquired. Usually, the energy response of a detector is determined by measurements using various radiation sources with different energies. But this method is limited to the availability of the sources with the desired energies. The procedure described in this paper uses the energy spectrum from Compton scattered photons, providing a continuous energy spectrum for the direct measurement of the energy response of the detectors. For our measurements we used an activated Cu-64 point source (phi = 1 mm) which was positioned in an aluminium sphere (phi = 2 cm). RESULTS: The measured LLD values for a whole-body PET-scanner ECAT EXACT HR+ (CTI/Siemens) were systematically lower than the nominal values (327 keV instead of 350 keV) and confirm the results of C. Watson, recently found for line sources. CONCLUSION: This leads to an increased number of detected low energy photons (mainly scattered photons) and has to be taken into account within the scatter correction.

Models, Theoretical↗

ECAT ART - a continuously rotating PET camera: performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department.

Advances in fully three-dimensional (3D) image reconstruction techniques have permitted the development of a commercial, rotating, partial ring, fully 3D positron emission tomographic (PET) scanner, the ECAT ART. The system has less than one-half the number of bismuth germanate detectors compared with a full ring scanner with the equivalent field of view, resulting in reduced capital cost. The performance characteristics, implications for installation in a nuclear medicine department, and clinical utility of the scanner are presented in this report. The sensitivity (20 cm diameterx20 cm long cylindrical phantom, no scatter correction) is 11400 cps.kBq-1.ml-1. This compares with 5800 and 40500 cps.kBq-1.ml-1 in 2D and 3D respectively for the equivalent full ring scanner (ECAT EXACT). With an energy window of 350-650 keV the maximum noise equivalent count (NEC) rate was 27 kcps at a radioactivity concentration of approximately 15 kBq.ml-1 in the cylinder. Spatial resolution is approximately 6 mm full width at half maximum on axis degrading to just under 8 mm at a distance of 20 cm off axis. Installation and use within the nuclear medicine department does not appreciably increase background levels of radiation on gamma cameras in adjacent rooms and the dose rate to an operator in the same room is 2 microSv. h-1 for a typical fluorine-18 fluorodeoxyglucose (18F-FDG) study with an initial injected activity of 370 MBq. The scanner has been used for clinical imaging with18F-FDG for neurological and oncological applications. Its novel use for imaging iron-52 transferrin for localising erythropoietic activity demonstrates its sensitivity and resolution advantages over a conventional dual-headed gamma camera. The ECAT ART provides a viable alternative to conventional full ring PET scanners without compromising the performance required for clinical PET imaging.

Equipment Design↗

Zipper injuries.

Explore the source record for details and available documents.

Child↗