PubMed Health⌕ Search

Biomedical subjects

C C Youngson

Publications and source records attributed to C C Youngson.

At least 19 recordsLinked to original sources

A fluid filtration and clearing technique to assess microleakage associated with three dentine bonding systems.

OBJECTIVES: The aims of this in vitro study were to (a) measure fluid flow through teeth restored with one of three dentine bonding systems and a resin composite restoration; (b) measure the distribution of a silver tracer through the same teeth, and make a comparison with fluid flow; and (c) investigate the effect of thermocycling on both measurement types. METHODS: Coronal segments of 30 premolars, randomly allocated to three equal groups, were assessed by fluid filtration. Each group was restored with a resin composite restoration in conjunction with Fuji Bond LC (FBLC), Scotchbond Multi-Purpose Plus (SMP+) or Prime&Bond 2.1 (P&B2.1). Fluid filtration rates were measured in the intact crown and then after cavity preparation, conditioning, dentine bonding, restoration and at 2 and 24 h, 1 week and 1 month following restoration. Six specimens from each group were thermocycled at 1 week. After final filtration measurements the specimens were perfused with silver nitrate and cleared before scoring tracer penetration. RESULTS: No significant differences (P > 0.05) in fluid filtration rates were found amongst the different bonding systems or at any restoration stage. Thermocycling was not associated with any significant (P > 0.05) increase in fluid filtration. Final fluid filtration and tracer distribution showed a weak and not statistically significant correlation (P > 0.05). The penetration of silver stain indicated a failure of the restorations to seal the cavity and demonstrated a possible pathway by which in vivo post-operative sensitivity could occur. CONCLUSIONS: Although not statistically significant, conditioning of the cavity increased the dentinal permeability but this effect was variable. Thermocycling had no statistically significant effect on microleakage.

Analysis of Variance↗

In vitro dentinal penetration by tracers used in microleakage studies.

Many microleakage studies, in their methodology, employ different tracers which may penetrate around restorative materials to varying extents due to their physical or chemical characteristics. The present series of in vitro studies were designed to compare the ability of freshly obtained microleakage tracers to enter cut dentinal tubules. Tracers selected were 5% eosin, 2% methylene blue, 50% silver nitrate and Indian ink all buffered, where necessary, to a range of pH 6.9-7.2. The solution of Indian ink was further investigated by particle size analysis to determine the range of particle sizes within the solution. Particles ranged from < 1 micron to 600 microns. Buffered and unbuffered solutions of the tracers were applied for 1 h to open cavities, devoid of a smear layer, prepared in 42 premolars. Specimens were sectioned longitudinally through the cavities either with or without water coolant. Penetration into dentinal tubules by the tracer resulted in an area of stained dentine and this area was subsequently measured using image analysis. The results demonstrated that there were few statistically significant differences between the areas of dentinal penetration associated with each tracer. Neither the tracer used, its pH nor sectioning technique had a predictably significant effect on dentinal penetration. Indian ink was observed to be capable of entering dentinal tubules.

Analysis of Variance↗

The dentine-bonding of a fractured non-vital anterior tooth.

This case illustrates an alternative management of a fractured non-vital incisor using adhesive techniques to avoid the disturbance of, and offer protection to, successful endodontic treatment. The rationale for the maintenance of sound tooth structure and the minimisation of coronal leakage, while adequately restoring aesthetics, is discussed.

Composite Resins↗

Diagnosis and treatment of the cracked tooth.

This review paper discusses the recognised factors which predispose to cracked-tooth syndrome. In addition, common presenting symptoms and the various methods to aid clinical diagnosis of this problem are examined. The incidence of the condition is reported and the prognosis of the various forms of fracture, as suggested by clinical presentation, are outlined with reference to the available literature. Benefits and relative demerits of traditional and more modern treatment options are presented and recommendations made for future research.

Cracked Tooth Syndrome↗

An in vitro study of the bond strength of light-cured glass ionomer cement in the bonding of orthodontic brackets.

The search to improve the properties of dental adhesives has lead to the development of light-cured glass ionomer cements. Using human teeth in vitro, the present study tested the shear/peel bond strengths of two light-cure materials ('Variglass VLC' and 'Fuji Lining LC') against a 'no-mix' composite orthodontic adhesive ('Right-On') and a chemically cured glass ionomer cement ('Ketac-Cem'). The light-cured materials were found to have an inferior bond strength compared with the two control adhesives. Based on the findings of this study, there is no evidence to support the use of the materials tested for the bonding of orthodontic brackets.

Acid Etching, Dental↗

In vitro fracture fixation: adhesive systems compared with a conventional technique.

To find out whether adhesive techniques could have a role in bone fixation in selected cases an in vitro comparison between the current 'Champy' miniplate system and bonded stainless steel was undertaken using cyanoacrylate or dental composite cement. 33 bovine ribs were sectioned to simulate fracture separation, divided randomly into three groups, and immobilised by one of the three treatments. Distraction across the 'fracture' was produced using a universal testing apparatus, and forces at failure were recorded in Newtons (N). Image analysis enabled the contact area of the adhesive to be determined in mm2, so the bond strength in N/mm2 was derived. The Champy system failed at a significantly greater force (N) than the adhesives (p = 0.000). There was no significant difference in bond strength between either of the adhesive systems tested.

Analysis of Variance↗

An in vitro assessment of tooth preparation for porcelain veneer restorations.

OBJECTIVES: This in vitro study aimed to examine the depth of preparation and incidence of dentine exposure resulting from the use of a 'freehand' technique to prepare maxillary central incisors for porcelain veneers. METHODS: Twenty-two maxillary central incisors were selected. Prior to preparation an index of the labial surface of each tooth was recorded and the tooth secured in a jig to permit accurate relocation. Two operators each prepared 11 teeth aiming to reduce the labial thickness evenly by 0.5 mm. Low viscosity silicone impression material was then placed on the index and the teeth relocated into the jig. Upon removal, this material was sectioned in the cervical, middle and incisal thirds of the tooth and its thickness measured using a toolmaker's microscope. The teeth were acid etched and also stained with a dentine dye to identify any area of dentine exposed during preparation. RESULTS: Significant differences (P < 0.001) in the depth of preparation at different sites, with least reduction in the mid-incisal region, were found. Greater reduction was found at the cervical and proximal margins with areas of dentine exposed at those sites in the majority of teeth. CONCLUSIONS: In view of the incidence and position of dentine exposure found in this study, the use of a dentine bonding system during the placement of porcelain veneers would appear essential when employing a 'freehand' preparation technique.

Dental Cavity Preparation↗

In vitro radiographic representation of the extent of voids within obturated root canals.

The aim of this study was to determine whether radiographs provide an accurate representation of the degree of root canal obturation following a cold lateral condensation technique. A total of 40 extracted single-rooted lower premolar teeth were prepared using either a standardized step-back technique or an ultrasonic device by one of two operators. The four groups each of 10 teeth were obturated using lateral condensation by a third operator. To assess apical leakage the obturated teeth were coated with nail varnish to within 2 mm of the apex and immersed in methylene blue for 48 h. The teeth were then radiographed in bucco-lingual and mesio-distal planes prior to subsequent sectioning in a bucco-lingual plane. Sections and radiographs were analysed using an image analysis apparatus to determine the proportion of root canal occupied by gutta-percha, void and/or sealer. Mean percentages of void calculated from the bucco-lingual radiographs, mesiodistal radiographs and tooth sections were 4.14%, 5.98% and 4.98%, respectively. Statistical analysis showed no significant differences between the radiographic views and the tooth sections (P > 0.05). Both planes of radiograph accurately represented the proportion of void when compared with the tooth section.

Analysis of Variance↗

Influence of age on the extent of voids in root canals sealed using a cold lateral condensation technique.

The aim of this study was to examine whether it is more difficult to achieve complete obturation of the root canal in teeth from different age groups, using the measurement of voids within the obturated canal to determine the quality of endodontic therapy. One-hundred and fifty-two single-rooted premolar teeth extracted from patients of known age were collected. Following cleaning and storage the teeth were decoronated and radiographed. Forty selected teeth were allocated to one of four age-groups, (under 20, 20-35, 36-50, over 50 years) each consisting of 10 teeth. The working length was determined radiographically and preparation was carried out using the step-back technique. Each canal was obturated using cold lateral condensation with Tubliseal cement. The roots were then sectioned longitudinally and photographed. Sections and transparencies were subjected to image analysis to determine the total areas of root canal, sealer and voids respectively and statistical analysis of the differences between the various age groups was undertaken. There was a trend towards a reduction in the areas of sealer and sealer plus void with respect to increasing age group, although no significant differences existed. A significant relationship (P < 0.05) was found between the area of voids found in the youngest group when compared with all other groups, the greatest cumulative area of voids being found in the youngest teeth.

Adult↗

Comparison of the quality of obturation following endosonic versus hand instrumentation.

This study was undertaken to compare the quality of root canal obturation following preparation by endosonic or hand instrumentation. Forty single-canal, extracted lower premolar teeth were selected. One group of 20 teeth was prepared using a standard step-back technique, the other 20 teeth were prepared with an ultrasonic machine. The groups were subdivided, with two operators preparing 10 teeth of each group. The teeth were obturated by a third operator using cold laterally condensed gutta percha. The root apices were then immersed in methylene blue dye for 48 h and the teeth sectioned longitudinally. Image analysis recorded the amount of sealer and void within the obturated canal. The linear distance of dye penetration was measured to provide an indication of apical seal. Examination of the root canal shape resulting from the different preparation techniques used was also undertaken. No significant difference was noted in the percentage of sealer and void present in the root canals obturated after endosonic or hand instrumentation. There was a slightly greater although not significant increase in the degree of linear penetration of dye in canals prepared endosonically. The endosonic technique used in this study appeared to produce a canal preparation of slightly less continuous taper than that obtained with hand preparation.

Analysis of Variance↗

An in vitro comparative analysis: scanning electron microscopy of dentin/restoration interfaces.

One hundred maxillary premolar teeth were randomly allocated to ten groups. Each group was restored with one of ten different restorative techniques. The teeth were stored in deionized water for 7d prior to longitudinal sectioning in a mesio-distal plane. Following sectioning, ten specimens from each group were chosen at random from the 20 available sections. The sectioned surfaces were polished using 600-grit SiC abrasive paper and etched for 10 s with 50% phosphoric acid to remove the smear layer produced by sectioning. Five tooth sections from the dentin bonding resin groups were allowed to dry at 20 degrees C for 24h. The glass ionomer-based groups were reimmersed in deionized water during this period. The remaining five sections from each group were replicated using an addition-cure vinyl polysiloxane impression material and an epoxy resin. A comparison was made of the sections and the replicas. All tooth specimens were sputter-coated with gold for 4 min and examined using a scanning electron microscope. Replicas were gold-coated for 3 min. Different tooth/restoration interfaces, associated with different materials, were observed. A marked difference between the replicas and tooth sections was observed for glass ionomer-based restorations but not for resin-based bonding systems. Representative samples of replicas and specimens are shown, and the significance of the observed differences is discussed.

Bisphenol A-Glycidyl Methacrylate↗

A technique for three-dimensional microleakage assessment using tooth sections.

Microleakage is commonly assessed using restored teeth, sectioned through the midline of the restoration. It is impossible to determine if this is representative of the leakage throughout the whole tooth. This pilot study examined the feasibility of calculating areas and volumes of leakage using serial sections of restored teeth which had been subjected to dye immersion and image analysis. Using the sections, perspex models of the teeth were constructed to present the pattern of the dye leakage into dentine. This appears to be a viable technique for the three-dimensional assessment of microleakage.

Composite Resins↗

Early in vitro marginal microleakage associated with different lining materials under Class II amalgam restorations.

The aim of this study was to determine which dental cavity lining material exhibited least microleakage when used under amalgam. Extracted premolar teeth, prepared with Class II cavities, had one of three lining materials (cavity varnish, zinc oxide-eugenol or light-cured glass-ionomer) placed. Following restoration the teeth were immersed in eosin and sectioned. Sections were subjected to image analysis measuring the linear leakage and area of spread into coronal dentine. Percentages in relation to restoration length and the area of crown dentine were calculated. Light-cured glass-ionomer cement liner significantly (P < 0.05) reduced all aspects of the microleakage parameters studied.

Analysis of Variance↗

In vitro microleakage associated with posterior composite restorations used with different base/bonding system combinations.

The study aimed to determine the base/restoration combination which allowed the least microleakage in Class II cavities. One hundred premolar teeth were prepared with a standardized, minimal two-surface cavity and randomly ascribed to ten equal groups. The cavities were restored by use of one of ten different material/technique combinations. Restored teeth were sealed to within 1 mm of the restoration margins with nail varnish prior to the immersion of the crowns in 5% (buffered) eosin for 48 h. The teeth were then hemisected longitudinally, in a mesio-distal plane, through the midline of the restoration by means of a diamond disc with water coolant, and one half of each tooth was then photographed. The transparencies were examined by image analysis programmed to facilitate calculation of the percentage of the tooth/restoration interface and of the crown dentin exhibiting dye penetration. Light- and chemically-cured glass-ionomer-based restorations showed similar amounts of leakage when expressed as a percentage area of crown dentin. This was significantly (p less than 0.05) less than that shown by cavities both etched and bonded. Cavities restored without enamel etching or involving the use of a bonding system exhibited significantly (p less than 0.05) greatest leakage.

Acid Etching, Dental↗

In vitro marginal microleakage: examination of measurements used in assessment.

Premolar teeth with Class II amalgam restorations placed after the application of cavity varnish (Group A), a light cured glass ionomer base (Group B) and 40 per cent polyacrylic acid as a pretreatment agent, followed by unset cermet cement (Group C) were examined for marginal leakage using dye penetration and image analysis. Including amongst the parameters examined were linear leakage length and leakage area, which were found to have no consistent correlation. Group A and C did not generally show significant differences in the parameters examined, whereas Group B exhibited significantly less linear leakage (P less than 0.001), and significantly less leakage area when the stained area was expressed as a percentage of available dentine (P less than 0.001). While allowing some linear leakage, it was found that the light cured glass ionomer base appeared to prevent the dye from entering the dentine. It is concluded that an assessment based solely on the leakage length is inadequate and that some measurement of penetration into dentine should be included in order to fully assess the microleakage potential of a material or technique.

Acid Etching, Dental↗

In vitro marginal microleakage associated with five dentine bonding systems and associated composite restorations.

Fifty sound premolar teeth, extracted for orthodontic purposes and stored at room temperature in physiological saline since extraction, were prepared with a standardized minimal two-surface Class II cavity. The teeth were then ascribed randomly to five groups, each of ten teeth. Each of four groups was restored using a different dentine bonding system and the associated posterior composite resin according to the manufacturer's instructions. The fifth group was restored with Superbond C & B dentine bonding system and Occlusin composite. After immersion in de-ionized water for at least 7 days, the teeth were sealed with nail varnish to within 1 mm of the margin of the restoration. The teeth were then immersed in 5 per cent buffered Eosin for 48 h. Following mesiodistal sectioning the sections were photographed and subjected to image analysis to establish the length of dye penetration at the tooth/restoration interface and the amount of dye penetration into the crown dentine. Tripton/Occlusin and XR Bond/Herculite XR groups showed a significantly (P less than 0.05) smaller amount of leakage than Gluma/Lumifor or Scotchbond 2/P50 combinations when assessed as a percentage of the tooth/restoration interface exhibiting leakage. When the percentage of crown dentine showing dye penetration was considered, the Tripton/Occlusin group showed less leakage than the other material combinations. It is concluded that Tripton, when used with the recommended composite, will allow significantly less microleakage than Gluma/Lumifor, Scotchbond 2/P50 or Superbond C & B/Occlusin combinations and a similar amount to XR Bond/Herculite XR in vitro.

Acid Etching, Dental↗

Speed variability of air-driven motors in the self-threading pin technique.

Effective pin placement is dependent upon correct preparation of the dentine channel. Various factors contribute to the success or otherwise of this channel preparation. One such factor is the rotational speed of the twist drill. It is widely recommended that the twist drill be operated within the 500-800 rpm speed range, in order to prevent a temperature rise in the pulp during the cutting process. This paper examines the ability of air-driven dental motors, when coupled to two speed-reduction handpieces with differing reducing ratios, to operate within this range. The results reveal a wide variation in the speed ranges of the motors tested. Of the two types of handpiece examined, it appears that a 10:1 speed reduction is appropriate for the majority of motors.

Dental Pins↗