PubMed Health⌕ Search

Biomedical subjects

C Cabo

Publications and source records attributed to C Cabo.

21 records · Page 2Linked to original sources

Reflection after delayed excitation in a computer model of a single fiber.

Reflection (reflected reentry) is a case of reentry in a one-dimensional structure, divided into proximal and distal segments, in which tissue excited by a wave front propagating in a forward direction is reexcited by electrical activity coming backward from the original direction of propagation. Cases of reflection have been demonstrated in Purkinje fibers and in ventricular muscle preparations containing multiple fibers. Several mechanisms possibly responsible for reflected reentry have been proposed. However, the difficulty in the interpretation of the experimental results, as well as the limited number of different conditions in which reflection was obtained, has kept open the question about conditions and mechanisms for reflection. We have developed a computer model in which reflection occurs. The model involves a single fiber and uses the DiFrancesco-Noble equations for the Purkinje fiber to model the ionic currents. The results show that reflection is possible in a single fiber and that diastolic depolarization (automaticity) is not a requirement for reflection. Active membrane responses to a just-above-threshold stimulus were important for achieving the necessary time delay. Systematic simulations showed further that reflection occurred only when the right coupling conditions linked a short or long proximal fiber to a short distal segment.

Action Potentials↗

Activation in unipolar cardiac electrograms: a frequency analysis.

We have developed and tested several detectors of local activations in unipolar cardiac electrograms; the detectors are based on the frequency content of the waveforms. For this study, myocardial regions with no local electrical activity were created with cryoablation in canine ventricles, so that the characteristics of electrograms reflecting local activation could be compared with those with only distant electrical activity. For each electrogram, representations of the original signal were created using the output of bandpass filters; for each representation, the value of the maximum amplitude was taken as a measurement of the frequency content of the electrogram in that frequency band. The content of each frequency band and the first derivative of the signal were tested as discriminators between local and distant electrical activity. Combinations of frequency bands were also tested using a logistic regression technique; certain combinations provided better detection than any of the individual frequencies or the first derivative. The inclusion of frequencies between 500 and 1000 Hz improved the detection performance, suggesting that sampling rates of 1000 samples per second or less may not be adequate for optimal discrimination. A detector based on multivariate analysis of different frequency components of a signal may be more effective than single-band filtering in discriminating between local and distant electrical activity in the heart, especially when those components have very different magnitudes.

Algorithms↗

Unidirectional block in a computer model of partially coupled segments of cardiac Purkinje tissue.

The initiation of a reentrant circuit requires a zone of slow conduction and a zone of unidirectional block. This study used computer model conditions under which partial coupling between segments of cardiac Purkinje tissue resulted in unidirectional block. The structure used was one-dimensional and divided into three segments: a middle segment of variable length coupled to two long (semi-infinite in concept) segments. The DiFrancesco-Noble equations represented the ionic currents of the membrane. The results show that the possibility of unidirectional block depends on the size of the middle segment and the coupling resistances between the segments. No combination of coupling resistances allowed unidirectional block for middle segments with a length of two space constants (4 mm) or longer. Unidirectional block occurred for many combinations of coupling resistances as the length of the middle segment decreased to around half a space constant (1 mm). The number of length combinations that caused unidirectional block decreased again as segment length further decreased. These results provide a possible mechanism of unidirectional block for situations where islands of viable tissue are connected through nonviable tissue, such as in a healed myocardial infarction.

Animals↗