PubMed Health⌕ Search

Biomedical subjects

C Cachera

Publications and source records attributed to C Cachera.

30 records · Page 2Linked to original sources

Enzyme-linked immunosorbent assay for human proapolipoprotein A-I using specific antibodies against synthetic peptide.

Apolipoprotein A-I (apoA-I), the major protein component of human high density lipoprotein, appears intracellularly as an intermediate precursor (proapoA-I) with a hexapeptide extension (Arg-His-Phe-Trp-Gln-Gln) at its amino terminus. To investigate the regulation of processes that regulate plasma apoA-I levels, a sensitive and simple assay for proapoA-I is required. We describe a specific enzyme-linked immunosorbent assay (ELISA) for quantification of proapoA-I using monospecific rabbit antibodies raised against the peptide: Arg-His-Phe-Trp-Gln-Gln-Asp-Glu-Pro. The monospecificity of antibodies to propeptide has been checked and no cross-reaction with mature apoA-I has been found although three first mature apoA-I amino acids (Asp-Glu-Pro) were included in the immunizing peptide. The assay is a non-competitive sandwich ELISA in which polystyrene microtiter plates were used with antibodies to propeptide adsorbed on the wells. After incubation with plasma samples, the bound proapoA-I was revealed by labeled rabbit polyclonal antibodies directed against mature apoA-I. The working range was 10 to 100 ng/ml, recovery of proapoA-I added to plasma was 94.6 to 106.5%, and the intra- and interassay coefficients of variation were 3.8% and 7.9%, respectively. A delipidation step using diisopropylether-n-butanol was necessary to expose antigen sites of proapoA-I in native lipoproteins. Mean level of proapoA-I in normal subjects was 87 +/- 15 micrograms/ml. It represented 7.1% of total apoA-I while in Tangier serum it represented 29%.

Apolipoprotein A-I↗

Enzyme-linked immunosorbent assay for serum amyloid A apolipoprotein with use of specific antibodies against synthetic peptides.

We describe a noncompetitive enzyme-linked immunosorbent assay for amyloid A apolipoprotein in human serum (apo SAA) in which specific antibodies against synthetic peptides are used. Microtiter plates were used as solid phase and coated with affinity-purified antibodies raised against SAA1-(95-104) peptide. After incubation with delipidated plasmas, the bound apo SAA was revealed by labeled antibodies raised against SAA1-(58-69) peptide. The assay offers several advantages over existing techniques: sensitivity, specificity, simplicity, and non-use of radioisotopes. Results correlate well with those by a nephelometric method in which polyclonal antibodies are used.

Amino Acid Sequence↗

[Assay of serum apolipoprotein A-II by electro-immunodiffusion on ready-for-use plates. Clinical applications].

Few papers have been devoted to the study of apolipoprotein A-II (apo A-II), one of the major peptides contained in HDL, probably because of the methodological difficulties associated with its assay. The aim of this study is to provide the clinical biochemist with a simply easy to use assay technique. We have been able to demonstrate the practical value of apo A-II assay in hepatology and in the detection of excessive drinkers. On the other hand, our results indicate that apo A-II is not a parameter of choice for the detection of coronary atherosclerosis.

Adult↗

Simultaneous measurement of plasma apolipoproteins A-I and B by electroimmunoassay.

We describe a simplified electroimmunoassay for quantification of human apolipoproteins A-I and B on prepared plates. A solution of agarose at 55 degrees C, containing hydroxyethylcellulose and antibodies, is poured onto a plastic film and allowed to gel. Wells are punched in the gels and the plates are dried for storage. Before use, they are rehydrated and buffered. We use succinylated Sudan Black to prestain lipoprotein fractions of plasma. After electrophoresing samples of plasma or standards for 3 h at 4 degrees C at 12.5 V/cm, we measure the peak heights and read the results from a standard curve prepared by using calibrated sera of known apolipoprotein B and A-I content as secondary standard. The within- and between-assay coefficients of variation were less than 4% in all cases. Results correlated well with those obtained by classic electroimmunodiffusion. Subjects with confirmed atherosclerotic lesions had significantly (p less than 10(-9)) lower ratios of apolipoprotein A-I to apolipoprotein B, compared with ratios in controls.

Apolipoproteins↗

Rapid sodium dodecyl sulfat/polyacrylamide gel electrophoresis of urinary proteins.

We describe a procedure for the convenient separation of proteins by sodium dodecyl sulfate/polyacrylamide gel electrophoresis of urine from cases of renal disease. A precipitation method that requires no special apparatus was used to concentrate the urinary proteins; for electrophoretic separation we used a commercially supplied polyacrylamide/cellulose gel slab. This method seems to be valuable for investigation of proteinuria; we recommend it for routine use.

Chemical Precipitation↗

[Application of polyacrylamide gel electrophoresis-SDS to the study of proteinuria (author's transl)].

The authors present a variant of the technique of sodium dodecylsulfate acrylamide gel electrophoresis (SDS-PAA) reported by Weber and Osborn, for the analysis of urinary proteins. SDS-PAA separates the proteins chiefly according to their molecular radius. SDS-PAA, as compared to acetate cellulose electrophoresis and immunoelectrophoresis, gives better resolution and may be recommended for the investigation of proteinuria.

Electrophoresis, Cellulose Acetate↗