PubMed Health⌕ Search

Biomedical subjects

C Caiati

Publications and source records attributed to C Caiati.

At least 19 recordsLinked to original sources

Non-invasive coronary flow reserve is correlated with microvascular integrity and myocardial viability after primary angioplasty in acute myocardial infarction.

OBJECTIVE: To test whether preserved coronary flow reserve (CFR) two days after reperfused acute myocardial infarction (AMI) is associated with less microvascular dysfunction (" no-reflow" phenomenon) and is predictive of myocardial viability. DESIGN: 24 patients with anterior AMI underwent CFR assessment in the left anterior descending coronary artery (LAD) with transthoracic echocardiography and myocardial contrast echocardiography (MCE) 48 h after primary angioplasty in the LAD (mean 4 (SD 2) and 3 (1) days, respectively). Low-dose dobutamine echocardiography was performed 6 (3) days after AMI and follow-up echocardiography at three months. RESULTS: No-reflow extent was greater in patients with impaired CFR (< 2.5) than in those with preserved CFR (> 2.5) (55 (35)% v 11 (25)%, p < 0.001). MCE reflow was more common in patients with preserved CFR (8/12) than in those with reduced CFR (1/12, p < 0.05). Wall motion score index in the LAD territory (A-WMSI) was similar at the first echocardiography (2.14 (0.39) v 2.32 (0.47), NS), although it was better in patients with preserved CFR at dobutamine (1.38 (0.45) v 1.97 (0.67), p < 0.05) and follow-up echocardiography (1.36 (0.40) v 1.97 (0.64), p < 0.05). An inverse correlation was found between CFR and A-WMSI at dobutamine and follow-up echocardiography (r = -0.49, p = 0.016 and r = -0.55, p = 0.005) and between MCE and A-WMSI at dobutamine and follow-up echocardiography (r = -0.75, p < 0.001 and r = -0.75, p < 0.001). By multivariate analysis MCE reflow remained the only predictor of recovery at both dobutamine and follow-up echocardiography (odds ratio 1.06, 95% CI 1 to 1.1, p = 0.009). CONCLUSION: CFR is inversely correlated with the extent of microvascular dysfunction at MCE two days after reperfused AMI. CFR and MCE reflow early after AMI are correlated with myocardial viability at follow up.

Angioplasty, Balloon, Coronary↗

Contrast-enhanced harmonic color Doppler for left ventricular opacification: improved endocardial border definition compared to tissue harmonic imaging and optimization of methodologyin patients with suboptimal echocardiograms.

OBJECTIVES: This study compared the efficacy of contrast-enhanced harmonic color Doppler (C-HCD) and tissue harmonic imaging (THI) for left ventricular endocardial border delineation and explored the optimal methodology of C-HCD in patients with suboptimal echocardiograms. BACKGROUND: The value of C-HCD in improving endocardium remains unknown. Effects of harmonic velocity-encoded color Doppler (HVD) and harmonic power Doppler (HPD) as well as contrast administration and image acquisition modalities on left ventricular opacification (LVO) have not been established. METHODS: One hundred (50 HVD, 50 HPD) patients with suboptimal echocardiograms during conventional fundamental echocardiography were studied with THI and C-HCD using Levovist. Each patient underwent different random contrast administration and image acquisition modalities. Endocardial border definition score index (EBDI), blooming artifacts, contrast destruction, and salvage of suboptimal echocardiograms were calculated in each patient after contrast enhancement. RESULTS: EBDI improved from 2.05 +/- 0.61 in THI to 2.73 +/- 0.48 in HVD, and 1.98 +/- 0.73 in THI to 2.69 +/- 0.51 in HPD (both P < 0.001). The conversion of a nondiagnostic image from fundamental echocardiography to an optimal diagnostic image was 33 (33%) patients in THI compared to 77 (77%) patients in C-HCD (P < 0.001). Blooming artifacts were seen more commonly in HVD than HPD, intermittent than continuous image acquisition, and bolus than infusion administration (all P < 0.001). There was less contrast destruction in intermittent compared with continuous image acquisition (P < 0.001). Contrast destruction was similar in HVD and HPD, bolus and infusion injection of contrast. The highest salvage rate of a nondiagnostic image from THI to an optimal diagnostic image was 45.5% and 42.4% in HPD mode, with intermittent image acquisition during bolus and infusion contrast administrations. CONCLUSIONS: C-HCD seems more effective in demonstrating improved endocardial border definition compared to THI. HPD has less blooming artifacts compared with HCD. The optimal method for LVO was to use HPD with intermittent image acquisition during bolus or infusion administration of Levovist.

Adolescent↗

Quantification of left ventricular function with contrast-enhanced harmonic colour Doppler and a semiautomated boundary detection algorithm in technically difficult patients: feasibility, accuracy, and inter-observer variability.

AIMS: Patients with poor quality echocardiograms impede the application of available automatic boundary detection technologies. Tissue harmonic imaging and contrast media can allow optimal differentiation of left ventricular blood pool and tissue, making it possible to utilize automatic boundary detection software for automatic non-operator-dependent computation of left ventricular volumes. We integrated contrast-enhanced harmonic colour Doppler with a semiautomated boundary detection algorithm to explore the feasibility, accuracy and inter-observer variability for left ventricular volume assessment in technically difficult patients. METHODS AND RESULTS: Twenty-six patients with more than two segments not clearly visualized in tissue harmonic imaging were studied with contrast-enhanced harmonic colour Doppler using Levovist. Twenty patients (77%) achieved full left ventricular contrast filling without apparent blooming artefacts. Contrast-enhanced harmonic colour Doppler-automatic boundary detection was successfully implemented in these 20 patients, despite three (15%) in which it was not possible to acquire more than three cardiac cycles' values. Contrast-enhanced harmonic colour Doppler-automatic boundary detection measurements agreed closely with the manually drawn data. Among the three independent readers in the three techniques, the best correlation, lowest SEE, smallest limits of agreement and inter-observer variability were obtained in contrast-enhanced harmonic colour Doppler-automatic boundary detection. CONCLUSION: Contrast-enhanced harmonic colour Doppler-automatic boundary detection was feasible and accurate in estimation of left ventricular volume and function in patients with poor acoustic windows. This technique significantly reduced inter-observer variability, thus improving reliability and confidence of investigators in left ventricular function assessment. Contrast-enhanced harmonic colour Doppler-automatic boundary detection may have great potential in clinical evaluation of left ventricular volume and function, especially when on-line software is available.

Algorithms↗

New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler.

BACKGROUND: We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally noninvasive approach. METHODS AND RESULTS: Fifty-six consecutive patients undergoing coronary angiography underwent transthoracic contrast-enhanced pulsed-wave Doppler recording of blood flow velocity in the LAD by use of harmonic color Doppler as a guide at rest and after maximal vasodilation by dipyridamole infusion. Contrast enhancement with the harmonic mode greatly improved the success rate of recording adequate pulsed-wave Doppler signal in the LAD. CFR was (mean+/-SD) 1.54+/-0.7 in patients with (group 1) and 2. 79+/-0.9 in patients without (group 2) significant LAD stenosis (lumen narrowing >70%) (P<0.001); sensitivity and specificity in detecting significant LAD stenosis were 86% and 90%, respectively. There was close agreement between CFRs determined by this new method and intracoronary Doppler flow wire. CONCLUSIONS: Contrast-enhanced transthoracic echo Doppler with the harmonic mode is a feasible and promising technique for assessing CFR in a totally noninvasive way.

Adult↗

Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment.

OBJECTIVES: The purpose of this study is to evaluate the feasibility in detecting blood flow in the left anterior descending coronary artery (LAD) using transthoracic color Doppler (CD) imaging (in both second harmonic and fundamental mode) along with contrast enhancement and to verify if this new noninvasive method along with adenosine is safe, rapid and effective in assessing coronary flow reserve (CFR). BACKGROUND: Feasibility of contrast-enhanced transthoracic Doppler recording (in both second harmonic and fundamental mode) of blood flow velocity in the LAD has not been assessed. Adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole and thus it can be more suitable for assessing CFR in conjunction with this method. METHODS: Sixty-one patients with angiographically patent LAD underwent CD (both in fundamental and harmonic mode) as well as color-guided pulsed wave (PW) Doppler recording of blood flow velocity in the distal LAD before and after intravenous contrast injection. A second group of patients (n = 77), undergoing coronary angiography, was submitted to transthoracic contrast-enhanced PW Doppler recording of blood flow velocity in the LAD using harmonic CD as a guide, at rest and during adenosine-induced hyperemia. RESULTS: Harmonic CD along with echo contrast consistently improved blood flow detection in the LAD; the success rate in detecting flow of optimal quality was 88% with this approach, whereas it was 11% and 16% with CD in fundamental mode, respectively, before and after contrast. Pulsed wave Doppler results paralleled those of harmonic CD (p < 0.001 contrast harmonic vs. fundamental). In the second group of patients coronary angiography revealed 0% to <40% stenosis in 24 patients (group I), > or =40% to < or =75% in 17 patients (group II) and >75% stenosis in 34 patients (group III). There was a significant difference in CFR among the three groups of patients; CFR for peak diastolic velocity was (mean +/- SD): 2.88+/-0.7 (group I), 2.09+/-0.5 (group II) and 1.51+/-0.5 cm/s (group II) (p < 0.05 group I vs. both group II and group III; p < 0.05 group II vs. group III). The whole examination took less than 10 min. CONCLUSIONS: Contrast-enhanced second harmonic Doppler recording of blood velocity in the LAD is highly feasible and in combination with adenosine it is a rapid, safe and effective method for assessing CFR ratio.

Adenosine↗

Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: comparison with intracoronary Doppler flow wire.

OBJECTIVES: We tested the hypothesis that coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD) as assessed by a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) is in agreement with CFR measurements assessed by intracoronary Doppler flow wire. BACKGROUND: Contrast-enhanced transthoracic second harmonic echo Doppler is a novel noninvasive method to detect blood flow velocity and reserve in the LAD. However, it has not yet been validated versus a gold-standard method. METHODS: Twenty-five patients undergoing CFR assessment in the LAD by Doppler flow wire were also evaluated by contrast-enhanced transthoracic Doppler to record blood flow in the distal LAD at rest and during hyperemia obtained by adenosine i.v. infusion. In five patients CFR was evaluated twice (before and after angioplasty). RESULTS: As a result of the combined use of i.v. contrast and second harmonic Doppler technology, feasibility in assessing coronary flow reserve equaled 100%. The agreement between the two methods was high. In fact, in all but five patients the maximum difference between the two CFR measurements was 0.38. Overall, the prediction (95%) interval of individual differences was -0.69 to +0.72. Reproducibility of CFR measurements was also high. The limits of the agreement (95%) between the two measurements were -0.32 to +0.32. CONCLUSIONS: Coronary flow reserve in the LAD as assessed by contrast-enhanced transthoracic echo Doppler along with harmonic mode concurs very closely with Doppler flow wire CFR measurements. This new noninvasive method allows feasible, reliable and reproducible assessment of CFR in the LAD.

Adenosine↗

Correlation of 99mTc-sestamibi SPECT myocardial perfusion imaging with absolute coronary flow reserve by a new noninvasive Doppler method in patients with stenoses of the left anterior descending coronary artery. A preliminary report.

BACKGROUND: Myocardial perfusion assessed by a pharmacological scintigraphic test is a time-honored method to assess the functional significance of a coronary stenosis. There is no study that has compared coronary flow reserve assessed by adenosine/base contrast-enhanced transthoracic echo Doppler in harmonic mode with myocardial perfusion by adenosine/base 99mTc-sestamibi SPECT. The aim of this study was to compare the absolute coronary flow reserve measured in the left anterior descending coronary artery using a new noninvasive method (transthoracic harmonic Doppler) with adenosine/base 99mTc-sestamibi SPECT. METHODS: Twenty-two patients scheduled for coronary angiography underwent evaluation of basal and hyperemic flow in the left anterior descending coronary artery using transthoracic harmonic Doppler. Simultaneously (during the same adenosine infusion) the patients were injected with 99mTc-sestamibi (10 mCi). Baseline scintigraphic study was obtained 4 hours later (99mTc-sestamibi, 30 mCi). RESULTS: Angiography showed in the left anterior descending coronary artery no or not significant stenosis (< 40% lumen narrowing) in 14 patients (Group I) and a severe stenosis (> 75%) in the remaining 8 patients (Group II). Coronary flow reserve dichotomized as normal (> or = 2.0) or abnormal (< 2.0) gave concordant results with SPECT. Overall, in fact, 18 studies (81%) were in agreement (k = 0.48, p = 0.02). In addition, coronary flow reserve proved to be a useful complementary tool to SPECT in patients with severe multivessel disease (and global hypoperfusion; 2 cases) and left bundle branch block (1 case). CONCLUSIONS: Coronary flow reserve assessed by transthoracic harmonic Doppler gives concordant results with SPECT perfusion scintigraphy. The diagnostic potential of SPECT may be increased by the noninvasive assessment of coronary flow reserve in the left anterior descending coronary artery.

Adult↗

[Coronary reserve].

Explore the source record for details and available documents.

Angioplasty, Balloon↗

Improved Doppler detection of proximal left anterior descending coronary artery stenosis after intravenous injection of a lung-crossing contrast agent: a transesophageal Doppler echocardiographic study.

OBJECTIVE: This study was designed to verify the usefulness of transesophageal Doppler recording of blood flow velocity in the proximal left anterior descending coronary artery, after a peripheral injection of a lung-crossing contrast agent (SHU 508A), in detecting and locating a hemodynamically significant stenosis (vessel narrowing > or = 50%) affecting this portion of the vessel. BACKGROUND: Transesophageal Doppler echocardiography has a limited diagnostic impact on the evaluation of proximal left anterior descending coronary artery stenoses. Peripheral injection of SHU 508A, a lung-crossing contrast agent enhancing Doppler signal to noise ratio in coronary arteries, may allow recording of localized disturbed blood flow velocity at the stenosis site even in the absence of a clear B-mode visualization of the vessel. METHODS: Transesophageal Doppler echocardiography, before and after echo contrast injection, was performed in 31 patients who underwent coronary angiography. Using color Doppler as a guide, pulsed wave Doppler recording of blood flow velocity in the left anterior descending coronary artery was attempted to detect a localized increase in blood flow velocity. B-mode evaluation of the vessel was also performed. RESULTS: Angiography showed a significant proximal left anterior descending coronary artery stenosis in 16 patients (group 1) and no stenosis in 15 patients (group 2). In 15 of 16 group 1 patients, Doppler after contrast injection revealed a localized velocity increase of at least 50% of the reference value; mean (+/-SD) percent increase in velocity was 150 +/- 89% (range 367% to 0%). In group 2 Doppler after contrast injection revealed a mild localized increase in velocity in four patients and no increase in velocity in the remaining 11 patients; mean (+/-SD) percent increase in velocity was 5 +/- 7% (range 21% to 0%, p < 0.001 vs. percent increase in group 1). When a percent velocity increase > or = 50% of the reference value was considered a positive criterion for detecting significant stenosis, the sensitivity and specificity were 92% and 100% respectively. The sensitivity of the evaluation before contrast injection or considering B-mode imaging alone was much lower (25% and 19%, respectively, p < 0.001 vs. evaluation after contrast injection). In addition, color Doppler after contrast injection correctly located the stenosis along the vessel, as compared with angiography. CONCLUSIONS: Blood flow evaluation of the proximal left anterior descending coronary artery by transesophageal Doppler echocardiography after contrast injection is a feasible and reliable method for detecting and locating significant stenoses affecting this part of the vessel and is an improvement over the traditional ultrasound approach.

Aged↗

Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies.

UNLABELLED: Thallium-201 and 99mTc-sestamibi images of the heart contain a significant amount of scattered events which degrade image quality. Newer generation gamma cameras exhibit enhanced energy resolution and hardware/software to perform scatter correction. The principal aim of this study was to evaluate the effects of these advances in instrumentation on the quantitation of defect size from tomographic images of the heart obtained from a cardiac phantom. METHODS: Tomographic images of a cardiac phantom containing no defect and defects of 5%-70% of total myocardial mass were acquired both with and without scatter correction for 201Tl and 99mTc studies. Data were acquired on a newer generation gamma camera with an energy resolution of 8.7% at 140 keV. From conventional short-axis slices of the heart, circumferential count profiles were generated from five representative slices. Defect size was computed from the fraction of radians that fell below a fixed threshold value in each of the five count profiles. The nadir value (min/max) of the count profiles in each study was used as an index of image contrast. RESULTS: For both 201Tl and 99mTc, threshold values between 55%-60% gave the best correlation (r > 0.99), with the lowest average absolute error in estimating defect size (< 2.1%). Scatter correction reduced the average absolute error to 0.8% for 99mTc and 1.4% for 201Tl, significantly reduced the nadir values for both isotopes (p < 0.0001 for both 201Tl and 99mTc and led to a marked improvement in image quality for both tracers. CONCLUSION: Scatter correction reduces the error associated with measurement of infarct size, increases image contrast and improves image quality for both 201Tl and 99mTc, as assessed in a phantom model.

Gamma Cameras↗

Improved Doppler signal intensity in coronary arteries after intravenous peripheral injection of a lung-crossing contrast agent (SHU 508A)

OBJECTIVES: We tested the hypothesis that SHU 508A, a new lung-crossing contrast agent capable of increasing the Doppler signal to noise ratio in the right heart as well as left heart cavities after intravenous injection, could increase Doppler signal intensity in coronary arteries, thus improving the feasibility and quality of transesophageal Doppler echocardiographic evaluation of coronary blood flow velocity. BACKGROUND: Coronary blood flow velocity can be evaluated by transesophageal Doppler echocardiography. However, an adequate Doppler tracing is obtainable in a relatively low percent of patients. METHODS: Transesophageal Doppler echocardiography of coronary arteries was performed in 35 patients before and after SHU 508A injection at four different dosages (200 mg/ml in 5 ml, 200 mg/ml in 10 ml, 300 mg/ml in 5 ml and 300 mg/ml in 10 ml). Color Doppler mapping of coronary flow and pulsed wave Doppler measurement of coronary blood flow velocity were attempted in all patients. RESULTS: Color Doppler flow mapping of 105 evaluated coronary segments (left main, left anterior descending and circumflex in 35 patients) was not detectable or was weak in 88% of patients before and 33% of patients after echo contrast injection (p < 0.0001); it was optimal (that is, well delineated with complete flow mapping of the explored vessel) in only 11% of patients before and 67% after echo contrast injection (p < 0.0001). In addition, pulsed wave Doppler signal quality improved after echo contrast injection: Pulsed wave Doppler recording of coronary blood flow velocity was not obtainable or was weak in 78% of cases before and 34% after echo contrast injection (p < 0.0001); pulsed wave Doppler recording of coronary blood flow velocity was optimal (that is, there was a complete and well defined outline of diastolic coronary blood flow velocity in 23% of cases before and 66% after echo contrast injection [p < 0.0001]. Both length and width of color Doppler mapping in the left anterior descending coronary artery increased after SHU 508A injection (from 5.75 +/- 5.32 and 1.51 +/- 1.17 to 17.04 +/- 8.76 and 4.21 +/- 1.78 mm, respectively, mean +/- SD, p < 0.0001). CONCLUSIONS: The feasibility and quality of recording coronary blood flow velocity by transesophageal Doppler echocardiography are considerably improved by intravenous injection of SHU 508A. The improved feasibility of this new semi-invasive method for evaluating coronary blood flow velocity and flow reserve can considerably increase its research and clinical utilization.

Aged↗

The importance of stress-induced cardiac wall motion abnormalities in the evaluation of drug intervention.

Stress-induced wall motion abnormalities are a sensitive marker of myocardial ischaemia. Stress echocardiography has recently been the subject of increasing interest because of its improved feasibility and compatibility with new and effective alternative stresses. Transoesophageal atrial pacing (TAP) with 2-dimensional echocardiography (2-D echo) is a recently developed echo-cardiographic stress procedure that has been shown to be reliable and effective in both the diagnosis and evaluation of stress-induced myocardial ischaemia. TAP with 2-D echo was performed after treatment with placebo and intravenous gallopamil 0.03 mg/kg in 12 patients with stable, reproducible angina of effort. Compared with placebo, gallopamil treatment increased the time to 1 mm ST-segment depression (6.6 vs 5.3 minutes; p less than 0.05) and improved the ventricular wall motion score at a heart rate of 130 beats/min (17 vs 15; p less than 0.01) and 150 beats/min (13 vs 11; p = 0.07). Three patients who developed angina after placebo administration were symptom-free after gallopamil. Thus, gallopamil exerts a beneficial effect on atrial pacing-induced ischaemia, by increasing the pacing time to the ischaemic threshold and reducing the extent of dysfunctional myocardium during ischaemia.

Aged↗

Prediction of cardiac events after uncomplicated myocardial infarction by cross-sectional echocardiography during transesophageal atrial pacing.

Atrial pacing can safely be utilized shortly after myocardial infarction. To evaluate the prognostic value of wall motion abnormalities induced by such pacing 83 consecutive patients with recent uncomplicated myocardial infarction underwent transthoracic cross-sectional echocardiography during transesophageal atrial pacing and upright bicycle exercise stress test. Patients were followed-up for 14 +/- 5 months. During the atrial pacing and the echocardiography, patients were defined at high risk if abnormalities of wall motion were detected in left ventricular regions remote from the infarcted area. Then, during the exercise stress test, high risk patients were those with ST segment depression greater than or equal to 1 mm. On the other hand, patients were considered to be at low risk if they had no abnormalities of wall motion during atrial pacing in remote regions or, in the case of the stress test, if they did not develop ST depression greater than or equal to 1 mm. Of the 83 patients, 21 had major cardiac events during the period of follow-up. Cardiac events occurred in 15/23 (65%) and 5/60 (8%, P less than 0.001) patients assigned to the groups adjudged to be at high and low risk, respectively, on the basis of echocardiographic results. Exercise testing was less reliable in identifying patients at risk of future cardiac events. Major events occurred in only 6 of the 19 patients with a positive stress test (32%, P less than 0.05 vs positive stress echocardiography) and in 14 of the 64 patients with a negative exercise stress test (22%, P = NS vs positive exercise stress test, P less than 0.05 vs negative atrial pacing echocardiography).

Cardiac Pacing, Artificial↗

Evaluation of the effects of gallopamil in patients with effort angina by transesophageal atrial pacing two-dimensional echocardiography.

Transesophageal atrial pacing (TAP) 2D echocardiography was performed after placebo (P) and gallopamil (G) (0.03 mg/kg iv) in 12 patients with stable, reproducible, effort angina. If compared to P study, during G the following changes were observed: 3 out of the 12 patients did not experience angina, time to ST-1mm increased from 5.3 +/- 1.3 to 6.6 +/- 1.6 min (p less than 0.05), wall motion score was improved both at 130 b/min (15.3 +/- 4.1 drug P, 17 +/- 4.8 drug G, p less than 0.01) and at 150 b/min (10.9 +/- 5.7 drug P, 12.8 +/- 6.3 drug G, p = 0.07). In conclusion, gallopamil has a beneficial effect on atrial pacing induced ischemia: it increases pacing time to ischemic threshold and reduces during ischemia the extent of dysfunctional myocardium.

Aged↗

[Acute effects of propionyl-L-carnitine on anomalies of parietal kinetics of the left ventricle induced by atrial pacing in patients with ischemic heart disease. A bidimensional echocardiographic study].

This double-blind randomized placebo (PL) controlled study was undertaken to evaluate, by 2D echo transesophageal atrial pacing (TAP), the effects of acute iv administration of a new compound propionyl-L-carnitine (PLC) on atrial pacing (AP) induced left ventricular wall motion abnormalities. Twelve male patients with coronary artery disease and normal regional motion at rest, after a preliminary 2D echo-TAP, on the eight and thirteenth day of trial were subjected to 2D echo-TAP 30 min after iv administration of 15 mg/Kg PLC or PL. For analysis, the left ventricle was divided into 11 segments. A wall motion score (WMS), evaluated at 130 b/min and at 150 b/min, was derived by adding together the scores assigned to each segment. Wall motion was graded +2 (normokinetic), +1 (hypokinetic), 0 (akinetic), -1 (dyskinetic). Left ventricular ejection fraction (EF) was evaluated at rest and at 150 b/min. Statistical analysis of the results was performed using a 2-way analysis of variance. The WMS at 130 b/min improved significantly after PLC vs PL from 18.66 +/- 2.46 to 19.50 +/- 2.77 (p less than 0.02). The WMS at 150 b/min improved significantly after PLC vs PL from 16.00 +/- 2.95 to 16.91 +/- 3.47 (p less than 0.01). The EF at rest was not significantly unchanged after PLC. The EF at 150 b/min was significantly different after PLC vs PL, from 53.6 +/- 7.36 to 55.6 +/- 6.45 (p less than 0.05). The blood pressure and the double product at rest and at 150 b/min were not unchanged after PLC.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗