Treatment planning for prostate implants using magnetic-resonance spectroscopy imaging.

PURPOSE: Recent studies have demonstrated that magnetic-resonance spectroscopic imaging (MRSI) of the prostate may effectively distinguish between regions of cancer and normal prostatic epithelium. This diagnostic imaging tool takes advantage of the increased choline plus creatine versus citrate ratio found in malignant compared to normal prostate tissue. The purpose of this study is to describe a novel brachytherapy treatment-planning optimization module using an integer programming technique that will utilize biologic-based optimization. A method is described that registers MRSI to intraoperative-obtained ultrasound images and incorporates this information into a treatment-planning system to achieve dose escalation to intraprostatic tumor deposits. METHODS: MRSI was obtained for a patient with Gleason 7 clinically localized prostate cancer. The ratios of choline plus creatine to citrate for the prostate were analyzed, and regions of high risk for malignant cells were identified. The ratios representing peaks on the MR spectrum were calculated on a spatial grid covering the prostate tissue. A procedure for mapping points of interest from the MRSI to the ultrasound images is described. An integer-programming technique is described as an optimization module to determine optimal seed distribution for permanent interstitial implantation. MRSI data are incorporated into the treatment-planning system to test the feasibility of dose escalation to positive voxels with relative sparing of surrounding normal tissues. The resultant tumor control probability (TCP) is estimated and compared to TCP for standard brachytherapy-planned implantation. RESULTS: The proposed brachytherapy treatment-planning system is able to achieve a minimum dose of 120% of the 144 Gy prescription to the MRS positive voxels using (125)I seeds. The preset dose bounds of 100-150% to the prostate and 100-120% to the urethra were maintained. When compared to a standard plan without MRS-guided optimization, the estimated TCP for the MRS-optimized plan is superior. The enhanced TCP was more pronounced for smaller volumes of intraprostatic tumor deposits compared to estimated TCP values for larger lesions. CONCLUSIONS: Using this brachytherapy-optimization system, we could demonstrate the feasibility of MRS-optimized dose distributions for (125)I permanent prostate implants. Based on probability estimates of anticipated improved TCP, this approach may have an impact on the ability to safely escalate dose and potentially improve outcome for patients with organ-confined but aggressive prostatic cancers. The magnitude of the TCP enhancement, and therefore the risks of ignoring the MR data, appear to be more substantial when the tumor is well localized; however, the gain achievable in TCP may depend quite considerably on the MRS tumor-detection efficiency.

Algorithms↗

Intensity-modulated tangential beam irradiation of the intact breast.

PURPOSE: To evaluate the potential benefits of intensity modulated tangential beams in the irradiation of the intact breast. METHODS AND MATERIALS: Three-dimensional treatment planning was performed on five left and five right breasts using standard wedged and intensity modulated (IM) tangential beams. Optimal beam parameters were chosen using beams-eye-view display. For the standard plans, the optimal wedge angles were chosen based on dose distributions in the central plane calculated without inhomogeneity corrections, according to our standard protocol. Intensity-modulated plans were generated using an inverse planning algorithm and a standard set of target and critical structure optimization criteria. Plans were compared using multiple dose distributions and dose volume histograms for the planning target volume (PTV), ipsilateral lung, coronary arteries, and contralateral breast. RESULTS: Significant improvements in the doses to critical structures were achieved using intensity modulation. Compared with a standard-wedged plan prescribed to 46 Gy, the dose from the IM plan encompassing 20% of the coronary artery region decreased by 25% (from 36 to 27 Gy) for patients treated to the left breast; the mean dose to the contralateral breast decreased by 42% (from 1.2 to 0.7 Gy); the ipsilateral lung volume receiving more than 46 Gy decreased by 30% (from 10% to 7%); the volume of surrounding soft tissue receiving more than 46 Gy decreased by 31% (from 48% to 33%). Dose homogeneity within the target volume improved greatest in the superior and inferior regions of the breast (approximately 8%), although some decrease in the medial and lateral high-dose regions (approximately 4%) was also observed. CONCLUSION: Intensity modulation with a standard tangential beam arrangement significantly reduces the dose to the coronary arteries, ipsilateral lung, contralateral breast, and surrounding soft tissues. Improvements in dose homogeneity throughout the target volume can also be achieved, particularly in the superior and inferior regions of the breast. It remains to be seen whether the dosimetric improvements achievable with IMRT will lead to significant clinical outcome improvements.

Breast↗

Real-time interactive simulator for percutaneous coronary revascularization procedures.

This article describes the simulation of real-time catheter navigation in our interactive interventional cardiology simulation system (ICard). ICard is designed to enable medical students or physicians to familiarize themselves with the techniques of interventional catheterization procedures. The ICard software provides three-dimensional (3-D) views of the blood vessels and fluoroscopic images for real-time visualization of the catheter position. The 3-D human vasculature is built from various image data sets and is represented with a central line hierarchy model. Navigation of the catheter and guide wire and their interaction with blood vessels are implemented by applying the finite element method. Physical modeling that features the elasticity of the catheter and guide wire was developed to provide a realistic simulation of catheterization procedures. An electromechanical device was also developed in the system, allowing physical manipulation of catheter and guide wire movements. ICard can be used for training and design of equipment for interventional cardiology and may be further extended for pretreatment planning.

Computer Simulation↗

Three-dimensional treatment planning for para-aortic node irradiation in patients with cervical cancer.

Three-dimensional treatment planning has been used by four cooperating centers to prepare and analyze multiple treatment plans on two cervix cancer patients. One patient had biopsy-proven and CT-demonstrable metastasis to the para-aortic nodes, while the other was at high risk for metastatic involvement of para-aortic nodes. Volume dose distributions were analyzed, and an attempt was made to define the role of 3-D treatment planning to the para-aortic region, where moderate to high doses (50-66 Gy) are required to sterilize microscopic and gross metastasis. Plans were prepared using the 3-D capabilities for tailoring fields to the target volumes, but using standard field arrangements (3-D standard), and with full utilization of the 3-D capabilities (3-D unconstrained). In some but not all 3-D unconstrained plans, higher doses were delivered to the large nodal volume and to the volume containing gross nodal disease than in plans analyzed but not prepared with full 3-D capability (3-D standard). The small bowel was the major dose limiting organ. Its tolerance would have been exceeded in all plans which prescribed 66 Gy to the gross nodal mass, although some reduction in small bowel near-maximum dose was achieved in the 3-D unconstrained plans. All plans were able to limit doses to other normal organs to tolerance levels or less, with significant reductions seen in doses to spinal cord, kidneys, and large bowel in the 3-D unconstrained plans, as compared to the 3-D standard plans. A high probability of small bowel injury was detected in one of four 3-D standard plans prescribed to receive 50 Gy to the large para-aortic nodal volume; the small bowel dose was reduced to an acceptable level in the corresponding 3-D unconstrained plan. An optimum beam energy for treating this site was not identified, with plans using 4, 6, 10, 15, 18, and 25 MV photons all being equally acceptable. Attempts to deliver moderate or high doses (50-66 Gy) to this region should be made only after careful analysis of the plan with techniques similar to those employed in this study.

Aged↗

Treatment planning for internal radionuclide therapy: three-dimensional dosimetry for nonuniformly distributed radionuclides.

A calculational approach is described that provides the spatially varying radiation absorbed dose, presented as isodose contours superimposed on CT images, from nonuniform and/or irregular cumulated activity distributions. CT images are read from magnetic tape and are displayed on a high-resolution color graphics display monitor. Source tissue geometries are defined on a series of contiguous CT images automatically (by an edge detection algorithm) or manually (using a trackball), thereby obtaining a three-dimensional representation of the various source volumes of activity. Dose calculations are performed using a radionuclide-specific absorbed dose point kernel in the form of a lookup table. The method described yields the spatially varying dose delivered to tumor and normal tissue volumes from a patient-specific cumulated activity distribution in a clinically implementable manner. This level of accuracy in determining normal tissue and tumor doses may prove valuable in the evaluation and implementation of radionuclides and radiolabeled compounds for therapeutic purposes.

Algorithms↗

Thalamic hemorrhage: a computed tomographic-clinical study in prognostic prediction.

A series of 50 patients with thalamic hemorrhage confirmed by CT Scan is reported. The size, location, extension, and ventricular perforation of the hemorrhage are accurately portrayed. The age of onset, sex, level of consciousness on admission, history of vomiting and headache and detailed neurological examination were studied and analyzed. All patients were evaluated 6 months after the attack using the Kanaya's grading of ability in daily life (ADL). The authors conclude that the size of hematoma, initial consciousness loss, impaired level of consciousness on admission and bilateral Babinski's sign indicates the poor prognosis in thalamic hemorrhage.

Activities of Daily Living↗

The mechanism of cyanide intoxication and its antagonism.

The mechanism of cyanide intoxication has been attributed to the inhibition of cytochrome oxidase, thereby decreasing the tissue utilization of oxygen. One mechanism of cyanide antagonism is by sequestering cyanide with methaemoglobin to form cyanmethaemoglobin and another mechanism is detoxifying with a sulphur donor to thiocyanate. Questions have been raised with regard to these classical mechanisms. Oxygen with nitrite-thiosulphate antagonizes the lethal effects of cyanide. Theoretically, increased oxygen should serve no useful purpose, as it is the tissue utilization of oxygen which is inhibited. In the nitrite-thiosulphate antidotal combination, the proposal is made that the predominate antidotal action of nitrite is a vasogenic action, rather than methaemoglobin formation, because when methaemoglobin formation is inhibited by methylene blue the protective action of sodium nitrite persists. This suggests that methaemoglobin formation plays only a small part, if any, in the therapeutic antagonism of the lethal effects of cyanide. The roles and implications of sodium thiosulphate and non-rhodanese substrates in the detoxification mechanism are compared. Lastly, a new approach to cyanide antagonism has been initiated which involves the erythrocyte encapsulation of thiosulphate and sulphurtransferase as an antidote and prophylaxis against cyanide.

Animals↗

Computation of radiation dose distributions for shielded cervical applicators.

While cervical applicators with shielded ovoids are used widely in brachytherapy, we know of no system for calculating dose distributions for them. For shielded sources, because of a lack of symmetry and because of a rapid variation of dose as a function of position relative to the source, extensive measured data in three dimensions are required. In the method we have developed, the dose at a given point from a source in a shielded ovoid is calculated by multiplying the dose from an unshielded source by the "effective attenuation factor" of the shields. The latter quantity is obtained by linear-interpolation in a three-dimensional table generated from measurements described in an earlier paper. The unshielded-source dose is calculated as the product of source strength, time of implant, distance-dependent geometry factor and a tabulated quantity called the "relative dose rate factor". Relative dose rate factor is obtained by dividing measured dose rate by the product of geometry factor and source strength. Division by the geometry factor reduces the amount of data required with respect to accuracy in linear-interpolation. Input localization data must include not only the position of the end points defining the source but also a third reference point to define the orientation of the shields.

Brachytherapy↗

Use of computerized tomography in dose calculations for radiation treatment planning.

The detailed anatomic information provided by CT scanners can be used to improve the accuracy of dose distribution calculations for radiation treatment planning. Commonly used methods for dose computations are described, with emphasis on their use with CT data, and measured data are presented to illustrate their relative merits. Modification of CT numbers to account for the difference in energies of diagnostic and therapeutic radiation is discussed. A description of a typical CT-based radiation treatment planning system is presented.

Humans↗

Energy and angular distributions of photons from medical linear accelerators.

For accurate three-dimensional treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the photons incident on the surface of the patient. Knowledge of the spectra is also useful in other applications, including the design of filters and beam modifying devices and determination of factors to convert ionization chamber measurements to dose. We have used Monte Carlo code (EGS) to compute photon spectra for a number of different linear accelerators. Both the target and the flattening filter have been accurately modeled. We find the mean photon energy to have a value lower than the generally perceived value of one-third the maximum energy. As expected, the spectra become softer as the distance from the central axis increases. Verification of the spectra is performed by computing dose distributions and half-value layers in water using the calculated spectra and comparing the results with measured data. We also examined the angular distributions of photons incident on the surface of the phantom. In currently used models of dose computations, it is assumed that the angular distribution of photons with respect to fan lines emanating from the source is negligible. Although the angular spread of photons with respect to the incident direction has been found to be small, its contribution to the diffuseness of the beam boundaries is significant.

Energy Transfer↗

Differential pencil beam dose computation model for photons.

Differential pencil beam (DPB) is defined as the dose distribution relative to the position of the first collision, per unit collision density, for a monoenergetic pencil beam of photons in an infinite homogeneous medium of unit density. We have generated DPB dose distribution tables for a number of photon energies in water using the Monte Carlo method. The three-dimensional (3D) nature of the transport of photons and electrons is automatically incorporated in DPB dose distributions. Dose is computed by evaluating 3D integrals of DPB dose. The DPB dose computation model has been applied to calculate dose distributions for 60Co and accelerator beams. Calculations for the latter are performed using energy spectra generated with the Monte Carlo program. To predict dose distributions near the beam boundaries defined by the collimation system as well as blocks, we utilize the angular distribution of incident photons. Inhomogeneities are taken into account by attenuating the primary photon fluence exponentially utilizing the average total linear attenuation coefficient of intervening tissue, by multiplying photon fluence by the linear attenuation coefficient to yield the number of collisions in the scattering volume, and by scaling the path between the scattering volume element and the computation point by an effective density.

Bone and Bones↗

Monte Carlo simulation of a cobalt-60 beam.

We have used the Stanford Electron Gamma Shower (EGS) Monte Carlo code to compute photon spectra from an AECL Theratron 780 cobalt-60 unit. Particular attention has been paid to the careful modeling of the geometry and material construction of the cobalt-60 source capsule, source housing, and collimator assembly. From our simulation, we conclude that the observed increase in output of the machine with increasing field size is caused by scattered photons from the primary definer and the adjustable collimator. We have also used the generated photon spectra as input to a pencil beam model to calculate the tissue-air ratios in water and compared it to a model which uses a monochromatic photon energy of 1.25 MeV.

Cobalt Radioisotopes↗