PubMed Health⌕ Search

Biomedical subjects

C Colyer

Publications and source records attributed to C Colyer.

3 recordsLinked to original sources

Noncovalent labeling of proteins in capillary electrophoresis with laser-induced fluorescence detection.

Interest in the use of capillary electrophoresis (CE) as a tool for protein separations continues to grow. Additionally, laser-induced fluorescence (LIF) detection schemes promise ultrasensitive detection of small quantities of these important biomolecules following their separation. In most cases, LIF detection of proteins necessitates their prior derivatization with a fluorescent label molecule. To minimize the amount of additional sample handling and time associated with such labeling procedures, not to mention the sometimes-stringent pH and temperature controls they require, noncovalent labeling is presented as a viable alternative. This review article considers established methods for noncovalent labeling of proteins for their subsequent analysis by CE-LIF. Label molecules suitable for excitation and emission in the ultraviolet, visible, and near-infrared regions of the spectrum are enumerated for a variety of protein analytes.

Animals↗

Making corporate compliance programs work.

Healthcare organizations have created corporate compliance programs in an effort to adhere to Federal government recommendations, minimize the risk of wrongful behavior, and possibly reduce fines that may result from a government investigation. Compliance programs may have undetected weaknesses. Corporate compliance officers, executives, and board members need to be certain that their organization's program has sufficient infrastructure, oversight, and resources; effective education and training; an effective mechanism (hotline) to receive reports of compliance problems; and ongoing auditing and monitoring capabilities.

Government↗

Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: application to rapid analyses of proteolytic digests.

This report describes the development of a compact and versatile, micromachined chip device enabling the efficient coupling of capillary electrophoresis to electrospray mass spectrometry (CE-ESMS). On-chip separation provides a convenient means of achieving rapid sample cleanup and resolution of multicomponent samples (typically 2-5 min) prior to mass spectral analysis. A low dead volume connection facilitating the coupling of microfabricated devices to CE-ESMS was evaluated using two different interfaces. The first configuration used disposable nanoelectrospray emitters directly coupled to the chip device via this low dead volume junction, thereby providing rapid separation of complex protein digests. The performance of this interface was compared with that of more traditional configurations using a sheath flow CE-ESMS arrangement where a fused-silica capillary of varying length enabled further temporal resolution of the multicomponent samples. The sensitivity and analytical characteristics of these interfaces were investigated in both negative and positive ion modes using standard peptide mixtures. The separation performance for synthetic peptides using a chip coated with amine reagent ranged from 26,000 to 58,000 theoretical plates for a sheath flow CE-ESMS interface comprising a 15-cm CE column. Replicate injections of a dilution series of peptide standards provided detection limits of 45-400 nM without the use of on-line preconcentration devices. The reproducibility of migration time ranged from 0.9 to 1.5% RSD whereas RSDs of 5-10% were observed on peak areas. The application of these devices for the analysis of protein digests was further evaluated using on-line tandem mass spectrometry.

Amino Acid Sequence↗