Erythroid-specific inhibition of the tal-1 intragenic promoter is due to binding of a repressor to a novel silencer.

The basic helix-loop-helix tal-1 gene plays a key role in hematopoiesis, and its expression is tightly controlled through alternative promoters and complex interactions of cis-acting regulatory elements. tal-1 is not expressed in normal T cells, but its transcription is constitutive in a large proportion of human T cell leukemias. We have previously described a downstream initiation of tal-1 transcription specifically associated with a subset of T cell leukemias that leads to the production of NH(2)-truncated TAL-1 proteins. In this study, we characterize the human promoter (promoter IV), embedded within a GC-rich region in exon IV, responsible for this transcriptional activity. The restriction of promoter IV usage is assured by a novel silencer element in the 3'-untranslated region of the human gene that represses its activity in erythroid but not in T cells. The silencer activity is mediated through binding of a tissue-specific nuclear factor to a novel protein recognition motif (designated tal-RE) in the silencer. Mutation of a single residue within the tal-RE abolishes both specific protein binding and silencing activity. Altogether, our results demonstrate that the tal-1 promoter IV is actively repressed in cells of the erythro-megakaryocytic lineage and that this repression is released in leukemic T cells, resulting in the expression of the tal-1 truncated transcript.

3T3 Cells↗

First use of cultured human urothelial cells for biocompatibility assessment: application to urinary catheters.

For several years, studies performed to estimate in vitro biocompatibility of urinary catheters have been carried out using permanent cell lines. But for a rational design of the testing procedure, the cell culture model should relate to the material application. This work presents the results of a probe study designed to obtain an in vitro model of normal human urothelial cells (HUC) and to test the relevance of this system in cytocompatibility experiments of urinary catheters currently used.A comparison is made with continuous cell lines, the use of which is recommended by normalization bodies. We exposed monolayers of HUC (well characterized for their proliferation, qualitative evaluation, and quantitative measurement of cytokeratins) and two continuous human cell lines to liquid extracts (either pure or diluted in the culture medium) of nine available catheters, including positive (latex) and negative controls, for a 24 h incubation. Then colorimetric assays (Neutral Red and MTT) were performed. The extracts of two polyurethanes provoked a significant toxic effect on HUC only, suggesting differences in sensitivity between the models used. This effect could be due to the presence of a great amount of barium (used as a radioopacifier) in extracts, as highlighted by results of absorption emission spectroscopy. A culture model of HUC may be of relevance for the screening of materials intended for urological practice.

Biocompatible Materials↗

Saturnism caused by hand-made plates: partial diagnosis by a computer-aided program.

A man, aged 41 years, suffering from anaemia and abdominal pains was admitted to the Department of Medicine. Over the previous 2 years he had had several periods in hospital for these symptoms. There was, apparently, no occupational or accidental exposure to toxic substances and a correct diagnosis of the condition had not been possible. The computer-aided program AIDEDIAG II was therefore used to attempt a diagnosis. This approach indicated possible saturnism which was confirmed by metabolic and lead analyses. The lead source was identified as the hand-made food-plates used by the patient for his meals.