PubMed Health⌕ Search

Biomedical subjects

C Crepaldi

Publications and source records attributed to C Crepaldi.

At least 19 recordsLinked to original sources

Sequential hemofiltration-hemodiafiltration technique: all in one?

Sequential dialysis techniques (i.e. pure ultrafiltration followed by dialysis) have been used in the past, due to their capability to remove large volumes of fluids without inducing hemodynamic instability. The disadvantages of the inadequate dialysis and the lack of technology lead to the decline such methods. Hemofiltration (HF) and hemodiafiltration (HDF) are recently being utilized in a greater proportion thanks to the on line fluid preparation systems. Each process (HF and HDF) has its own benefits in the removal of small, medium and high-molecular weight substances and in the hemodynamic stability. Sequential hemofiltration/ hemodiafiltration (SHF/HDF), may combine the benefits and eliminate the disadvantages of each method. Furthermore they can be easily applied nowadays, due to the development of new high technological hemodialysis machines. In order to evaluate the feasibility and the effects of SHF/HDF we studied 7 chronic hemodialysis patients (6 months of treatment with SHF/HDF switched to 6 months of SHDF/HF), using the same machine (AK200 ULTRA), with on line fluid preparation system and the same type of dialyzer (Polyflux 210). The feasibility of such techniques (SHF/HDF or vice versa) resulted excellent. All sessions left the patients in a condition of well-being making fulltime work. No difference was observed between the different period of treatment, but a reduction in pre value was observed in calcium-phosphorous product, C-reactive protein and beta2-microglobulin, at the end of the sequential techniques. SHF/HDF therapy is a very promising technique. Further studies are needed to better explore the potential of such a therapeutic approach in the quality of life, the hemodialysis adequacy and the hemodynamic stability of our patients.

Adult↗

Sequential convective therapies (SCT): a prospective study on feasibility, safety, adequacy and tolerance of on-line hemofiltration and hemodiafiltration in sequence.

Sequential dialysis techniques (i.e pure ultrafiltration followed by dialysis) have been used in the past, due to their capability to remove large volumes of fluids without inducing hemodynamic instability. The disadvantages of inadequate efficiency and lack of technology lead to the decline of such methods. Hemofiltration (HF) and hemodiafiltration (HDF) are recently being utilized in a greater proportion thanks to on-line fluid preparation systems. Each process (HF and HDF) has its own benefits in the removal of small, medium and high-molecular weight substances and in hemodynamic stability. Sequential convective therapies (SCT) such as hemofiltration-hemodiafiltration in sequence (HF-HDF) may combine the benefits and eliminate the disadvantages of each method and should be studied in order to explore their potential application in modern dialysis. Furthermore they can be easily applied nowadays, due to the development of new sophisticated dialysis machines. In order to evaluate the feasibility, safety, efficiency and tolerance of different SCT methods we studied 3 schedules: SCT1: 1h pre-dilution HF followed by 3h of post-dilution HDF (in the HF mode we lost 25% of the total fluid that had to be removed). SCT2: 1h pre-dilution HF followed by 3h of post-dilution HDF (in the HF mode we lost 50% of the total fluid that had to be removed). SCT3: 2h pre-dilution HF followed by 2h of post-dilution HDF (in the HF mode we lost 50% of the total fluid that had to be removed). We studied 6 chronic hemodialysis patients using the same machine (AK200 ULTRA), with on-line fluid preparation system and the same type of dialyzer (Polyflux 210). SCT schedules were compared to on-line HF, on-line HDF and high flux dialysis performed with the same dialyzers. The treatments resulted safe, easy, feasible and well tolerated with an improved hemodynamic response to high volume convective therapies. Adequacy of treatment was satisfactory in all SCT schedules while middle molecular weight solute clearance and removal resulted higher in treatments with higher convective component. SCT might represent an interesting option for the future especially in patients with hemodynamic instability and requirements for interventions during treatment.

Blood Pressure↗

Dialytic performance evaluation of Rexeed: a new polysulfone-based dialyzer with improved flow distributions.

New dialyzers are designed to optimize the convective and diffusive components of solute transport. Asahi Kasei Medical Co.,Ltd.has developed a new high flux dialyzer series called Rexeed with improved flow distributions. We evaluated the in vivo dialytic performance of two dialyzers of the Rexeed series: Rexeed-18A and Rexeed-25A (1.8 m2 and 2.5 m2 ). We calculated the clearance for urea,creatinine,phosphate and b2-microglobulin both in high flux dialysis (HFD)and in 15 liter postidiluitional on-line hemodiafiltration (HDF)mode. With n = 3 patients in high flux HD at blood flow 450, 400, 350 and 250 ml/min we found remarkably high clearance for urea (347 +/- 4%, 305 +/- 0%, 288 +/- 5%, 230 +/- 3%, for Rexeed-18A and 361 +/- 3%, 329 +/- 0%, 313 +/- 1%, 234 +/- 3%for Rexeed-25A),creatinine (282 +/- 10%, 234 +/- 0%, 221 +/- 8%, 174 +/- 8%, for Rexeed-18A and 276 +/- 6%, 245 +/- 0%, 226 +/- 9%, 172 +/- 13% for Rexeed-25A),phosphate (347 +/- 0%, 316 +/- 0%, 275 +/- 4%, 202 +/- 16%, for Rexeed-18A and 364 +/- 3%, 365 +/- 0%,286 +/- 3%, 224 +/- 2% for Rexeed-25A)and b2-microglobulin (133 +/- 21%, 124 +/- 0%,118 +/- 12%, 98 +/- 11%, for Rexeed-18A and 159 +/- 8%, 169 +/- 0%,157 +/- 8%, 129 +/- 7% for Rexeed-25A) With n = 2 patients in HDF at blood flow 300 ml/min we found remarkably high clearance for urea (268 +/- 2%, for Rexeed-18A and 283 +/- 2% for Rexeed-25A),creatinine (183 +/- 6%for Rexeed-18A and 205 +/- 9% for Rexeed-25A),phosphate (245 +/- 3%, for Rexeed-18A and 270 +/- 2% for Rexeed-25A)and b2-microglobulin (166 +/- 12%, for Rexeed-18A and 192 +/- 4% for Rexeed-25A). Our preliminary evaluation describes the characteristics and the performances of a new polysulfone-based hemodialyzer series called Rexeed. Several innovative features have been implemented by the manufacturer. These constructive approaches seem to have produced a positive effect on the dialyzer performance at the bedside.

Blood Flow Velocity↗

Analysis of outcome of pregnancy in type 1 diabetics treated with insulin pump or conventional insulin therapy.

We evaluated the outcome of pregnancies followed between 1990 and 2000 in 93 women with type 1 diabetes, treated with conventional intensive insulin therapy (n=68) or continuous subcutaneous insulin infusion (n=25). We evaluated metabolic control (fasting and 1-hour post-prandial plasma glucose and HbA1c levels), spontaneous or induced abortions, time and mode of delivery, maternal outcome (pregnancy-induced hypertension, preeclampsia, placental insufficiency, hydramnios, hypoglycemic coma, ketoacidosis) and fetal outcome (weight, hypoglycemia, hypocalcemia, hyperbilirubinemia, fetal distress, asphyxia, hyaline membrane disease, polycythemia, shoulder dystocia, malformations). Patients treated with insulin pump more frequently had background retinopathy and clinical neuropathy. No significant differences were observed between the two groups in metabolic control and maternal outcome. Glycemic control, non-optimal in the prepregnancy state, improved significantly during pregnancy, as shown by the progressive reduction in HbA1c levels. As regards fetal outcome, no differences were observed between the two groups in morbidity and especially in malformation rate. Patients with malformed babies did not have optimal metabolic control at conception. Thus, maternal and perinatal outcomes were comparable in patients treated with insulin pump and continuous subcutaneous insulin therapy, and depended on metabolic control. In patients in higher White's class and with more unstable glycemia, we achieved metabolic control and outcomes comparable with those of women of lower White's class and more stable glycemic values using the insulin pump. Our data suggest that insulin pump therapy is useful in problematic, complicated cases of women who want a baby.

Adult↗

Effects of novel manufacturing technology on blood and dialysate flow distribution in a new low flux "alpha Polysulfone" hemodialyzer.

The main target for low flux hemodialyzers is an efficient low molecular weight solutes clearance. Such efficiency is largely dependent on the optimization of diffusion between blood and dialysis solution. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. Thus optimized flow distribution both in the blood and dialysate compartment becomes quintessential for the maximal efficiency of the diffusion process within the hemodialyzer. The present paper describes the distribution of the blood and dialysate flows in a new low flux polysulfone hollow fiber hemodialyzer characterized by a specific undulation of the fibers and a new cutting technology of the fibers for an improved micro-flow condition in the blood compartment headers. Twelve Diacap alpha Polysulfone LO PS 15 (1.5 sqm) (B. Braun Medizintechnologie, Melsungen Germany) were employed for the study. Six were analyzed in vitro and six were studied in vivo. Blood flow distribution was studied in vitro by dye injection in the blood compartment during experimental extracorporeal circulation utilizing human blood with hematocrit adjusted at 33%. Sequential images were obtained with a helical scanner in a fixed longitudinal section of the dialyzer 1 cm thick. Average and regional blood flow velocities were measured utilizing the reconstructed imaging sequence. The method allowed the calculation of single fiber blood flow (SF Qb) and the mass transfer zone (MTR) definition in digitally subtracted images. The patterns 20-10 and 40-30 were utilized. The same technology was used to evaluate flow distribution in the dialysate compartment after dye injection in the Hansen's connector. Regional dialysate flow was calculated in central and peripheral sample areas of 1 cm2. Six in vivo hemodialysis treatments on patients with end stage renal disease were performed at three different blood flow rates (250-350 and 450 ml/min) in order to measure urea, creatinine and phosphate clearance. Macroscopic and densitometrical analysis revealed that flow distribution was homogeneous in the blood compartment while in the dialysate compartment a slight difference between the peripheral and central regions in terms of flow velocity was observed. This however was not generating channeling phenomena. Urea creatinine and phosphate clearances were remarkably high and so were the Kt/V observed in all sessions, especially in relation to the studied blood flows. In conclusion, a significant blood to dialysate flow match with optimized countercurrent flow condition was observed in the studied hollow fiber hemodialyzers. Such optimization might be due both to the improved dialyzer design at the level of the blood header and to the specific fiber undulation that prevents dialysate channeling.

Biocompatible Materials↗

Caspase-3 and -8 activation and cytokine removal with a novel cellulose triacetate super-permeable membrane in an in vitro sepsis model.

Pro-apoptotic molecules are generated during sepsis which may be responsible for alteration of organ function in sepsis. Removal of systemic apoptotic activity may affect recovery from sepsis. Current high flux membranes might not be sufficiently permeable to eliminate pro-apoptotic factors. We evaluated the elimination of pro-apoptotic factors induced by LPS in human whole blood by a super-permeable cellulose triacetate membrane (SUREFLUX FH 150, Nipro, Osaka, Japan) in comparison to a standard high flux cellulose triacetate membrane (UT 700, Nipro, Osaka, Japan) and a polyethersulfone plasmafilter (Bellco, Mirandola Italy) in an in vitro blood circulation. We spiked human whole blood with lipopolysaccharide from Escherichia coli (Serotype 026-86, 10 mg/ml), incubated it for 3 hours to allow cytokine generation and recirculated it at 300 ml/min for 3 hours. The UF line was first returned to the blood module at 10 min. After this, the UF was drained from 10 to 60 min at a rate of 1000 ml/h. Zero balance was obtained by re-infusion of bicarbonate buffered hemofiltration fluid. Apoptosis was assessed on U937 monocytes (incubated with plasma or ultrafiltrate) by fluorescence microscopy dyes (Hoechst 33342, propidium iodide) and annexin V flow cytometry. Caspase-3 and Caspase-8 activity was assessed on the recirculated blood monocytes by spectrophotometric methods. IL-2, IL-10 and TNFalpha were determined by commercially available ELISAs. Sieving coefficients and clearances were determined for the different cytokines. Caspase-3 and Caspase-8 were activated by LPS and remained either stable or increased during in vitro circulation. Apoptosis activity of U937 cells, when incubated with the ultrafiltrate, increased in parallel with arterial plasma values (for Uf: UT700 = 23.1%; Sureflux FH150 = 42.5%). However, by 60 min the apoptotic activity recorded with the ultrafiltrate was reduced to the levels of arterial plasma (for Uf: UT700 = 19.8%; Sureflux FH150 = 11.2%). Sieving coefficients in the super-permeable membrane were significantly higher for all measured cytokines in comparison to the standard high flux membrane (e.g. TNFalpha 0.72 vs 0.03 p < 0.001) and close to the values observed for the plasmafiltration membrane. Nevertheless protein losses measured by albumin leakage were much lower with the Sureflux filter in comparison to the plasmafilter. In conclusion, pro-apoptotic factors can be eliminated by dialytic membranes with the removal rate maximized by using super high flux dialysers which may represent a compromise between hemofiltration and plasmafiltration membranes.

Apoptosis↗

Different rates of CD4+ and CD8+ T-cell proliferation in interleukin-2-treated human immunodeficiency virus-positive subjects.

BACKGROUND: Interleukin-2 (IL-2) has been used successfully to increase CD4 cell counts in patients who are human immunodeficiency virus (HIV) positive. The mechanisms involved in this phenomenon are unknown. We hypothesized that a differential proliferation rate of CD4+ compared with CD8+ lymphocytes could be related to the increase of CD4 counts and of CD4/CD8 ratios that occur in HIV+ patients during IL-2 treatment. METHODS: We enrolled in our study 14 HIV+ patients treated with IL-2 or with highly active antiretroviral therapy (HAART) during a 96-week observation period. Using flow cytometry, we measured longitudinally the expression of the Ki67 antigen in peripheral blood CD4+ and CD8+ lymphocyte subsets. RESULTS: Compared with HAART alone, IL-2 produced a rapid increase of Ki67+ proliferating CD4 cells and a concomitant increase of the CD4/CD8 ratios, whereas the corresponding CD8 proliferation increased slightly. On the contrary, HAART alone was effective in suppressing equally both CD4 and CD8 proliferation. CONCLUSIONS: Our results suggest a selective activity of IL-2 on CD4 T-cell proliferation; on the contrary, CD8-specific proliferation is affected minimally during treatment. This information may offer the potential to plan correctly immune activating regimens.

Antiretroviral Therapy, Highly Active↗

Lymphocyte subsets and viral load in patients with HIV-associated non-Hodgkin's lymphoma treated with anti-CD20 monoclonal antibody and chemotherapy.

The anti-CD20 monoclonal antibody Rituximab is a novel antitumor agent used in association with chemotherapy (CT) for the treatment of high-grade/intermediate non-Hodgkin's lymphomas (NHL) in HIV-negative populations. This therapeutic combination is currently also being explored in HIV-positive patients with NHL (HIV-NHL). The objective of our study was to determine CD4 and CD8T cell counts, HIV plasma viremia and proviral load in patients with CD20-positive HIV-NHL treated with Rituximab plus CT and highly active antiretroviral therapy (HAART). We studied eight patients with HIV-NHL treated by anti-CD20 and CT before, after three, and after six cycles of therapy; CD4, CD8 and CD19 lymphocyte subsets were measured by monoclonal antibodies and flow cytometry. HIV plasma viremia was determined by the b-DNA assay, and proviral load by a quantitative competitive PCR. CD4T cell counts remained stable after three cycles of therapy, while a significant reduction of this subset was present at the end of therapy. HIV plasma viremia was significantly reduced after the third cycle, but returned to pretreatment levels at the end of therapy; we also observed individual fluctuations of proviral load during therapy, this marker being increased in two out of three patients at the end of therapy. These observations suggest that Rituximab plus CT accelerated the rate of CD4 depletion and of HIV replication in the peripheral blood of HIV-NHL patients and that HAART may be able to delay these effects.

Adult↗

Practice pattern and treatment options for kidney patients in a single North Italian nephrology center.

The experience and the current practice of a single center located in northern Italy is reported. The center of Vicenza is a self-standing nephrologic unit serving a population of about 300,000 individuals. The overall province counts approximately 800,000 individuals and some of them are referred to our center from peripheral hospitals for renal transplantation and/or particular pathologic conditions. The center offers an integrated approach to the treatment of uremia including hemodialysis (HD), peritoneal dialysis (PD), and renal transplantation. In HD and PD, the most peculiar aspect is the treatment personalization that leads to numerous types of applied therapies and technologies. The policy of the center is based on the belief that the nephrology team has a substantial influence on the outcomes of dialysis patients. A large number of treatment options are available. Special care is placed on the delivery of an adequate amount of dialysis, but the fractional clearance of urea in relation to volume (Kt/V) is seen as a prerequisite and other factors are considered important. Reduction in mortality and morbidity is largely dependent on beginning therapy early in the course of renal treatment. The attainment of appropriate hemoglobin concentrations, good nutrition, good control of calcium and phosphorus metabolism, lipids, and blood pressure, is considered of great importance. Beyond all these factors the time spent by the physician with the patient is considered one of the major factors influencing quality of care. The particularly low mortality of the center (6%/yr) may also be ascribed to a lower incidence of diabetes and other comorbidities.

Delivery of Health Care↗

Brain function rescue effect of lactate following hypoglycaemia is not an adaptation process in both normal and type I diabetic subjects.

AIMS/HYPOTHESIS: We have previously shown that lactate protects brain function during insulin-induced hypoglycaemia. An adaptation process could, however, not be excluded because the blood lactate increase preceded hypoglycaemia. METHODS: We studied seven healthy volunteers and seven patients with Type I (insulin-dependent) diabetes mellitus with a hyperinsulinaemic (1.5 mU.kg-1.min-1) stepwise hypoglycaemic clamp (4.8 to 3.6, 3.0 and 2.8 mmol/l) with and without Na-lactate infusion (30 mumol.kg-1.min-1) given after initiation of hypoglycaemic symptoms. RESULTS: The glucose threshold for epinephrine response was similar (control subjects 3.2 +/- 0.1 vs 3.2 +/- 0.1, diabetic patients = 3.5 +/- 0.1 vs 3.5 +/- 0.1 mmol/l) in both studies. The magnitude of the response was, however, blunted by lactate infusion (AUC; control subjects 65 +/- 28 vs 314 +/- 55 nmol/l/180 min, zenith = 2.6 +/- 0.5 vs 4.8 +/- 0.7 nmol/l, p < 0.05; diabetic patients = 102 +/- 14 vs 205 +/- 40 nmol/l/180 min, zenith = 1.4 +/- 0.4 vs 3.2 +/- 0.3 nmol/l, p < 0.01). The glucose threshold for symptoms was also similar (C = autonomic 3.0 +/- 0.1 vs 3.0 +/- 0.1, neuroglycopenic = 2.8 +/- 0.1 vs 2.9 +/- 0.1 mmol/l, D = autonomic 3.2 +/- 0.1 vs 3.2 +/- 0.1, neuroglycopenic 3.1 +/- 0.1 vs 3.2 +/- 0.1 mmol/l) but peak responses were significantly attenuated by lactate (score at 160 min C = 2.6 +/- 1 vs 8.8 +/- 1, and 0.4 +/- 0.4 vs 4.8 +/- 1, respectively; p = 0.02-0.01, D = 1.3 +/- 0.5 vs 6.3 +/- 1.7, and 2.3 +/- 0.6 vs 5.7 +/- 1.1 p = 0.07-0.02). Cognitive function deteriorated in both studies at similar glucose thresholds (C = 3.1 +/- 0.1 vs 3.0 +/- 0.1, D = 3.2 +/- 0.1 vs 3.3 +/- 0.2 mmol/l). Although in normal subjects a much smaller impairment was observed with lactate infusion (delta four-choice reaction time at 160 min = 22 +/- 12 vs 77 +/- 31 ms; p = 0.02), in Type I diabetic patients lactate infusion was associated with an improvement in cognitive dysfunction (0.2 +/- 0.4 vs -38 +/- 0.2 delta ms, p = 0.0001). CONCLUSION/INTERPRETATION: A blood lactate increase after the development of hypoglycaemic symptoms reduces counterregulatory and symptomatic responses to insulin-induced hypoglycaemia and favours brain function rescue both in normal and diabetic subjects. These findings confirm that lactate is an alternative substrate to glucose for cerebral metabolism under hypoglycaemic conditions.

Acclimatization↗

Plasma free fatty acids and endothelium-dependent vasodilation: effect of chain-length and cyclooxygenase inhibition.

Free fatty acids (FFA) are known to interfere with glucose metabolism. Moreover, it has been shown that they are able to impair the endothelium-dependent vasodilation. Therefore, we sought to determine whether their negative effect on endothelial function depends on their chain length or on their ability to modify PG production. Fourteen normal volunteers were studied under baseline conditions and then randomly allocated to two of the following four studies: 1) long chain triglyceride (LCT) emulsion and heparin infusion (n = 7), 2) infusion of an emulsion containing 56% medium chain triglycerides (MCT) and 44% LCT plus heparin (n = 7), 3) infusion of LCT and heparin preceded by an i.v. bolus of 900 mg lysine-salicylate (ASA; n = 7), and 4) after an i.v. bolus of ASA (n = 7). Basal forearm blood flow (FBF), endothelium-dependent vasodilation in response to intraarterial acetylcholine (Ach), and endothelium-independent vasodilation in response to intraarterial nitroprusside were assessed by venous occlusion plethysmography. Both LCT and MCT infusions significantly increased basal FBF from 1.58 +/- 0.35 to 2.60 +/- 0.76 and 2.28 +/- 0.56 mL/min 100 mL tissue, respectively (both P < 0.05). This increase was also observed for LCT plus heparin, but not after ASA alone. The percent increase in FBF during Ach was lowered during both LCT (252 +/- 34% of the ratio infused/control arm at maximal Ach dose) and MCT (255 +/- 41%) compared to the baseline conditions (436 +/- 44%; both P < 0.05). The response to Ach was also lower during LCT plus ASA, whereas it was similar to baseline with ASA alone. No differences were observed in the response to nitroprusside among the experimental conditions. In conclusion, 1) the effect of FFA on endothelium-dependent vasodilation is independent of their chain length; 2) both LCT and MCT increase baseline FBF, independently from cyclooxygenase inhibition; and 3) acute ASA administration does not affect endothelium-dependent vasodilation. The FFA effect on the endothelial response to Ach may contribute to altered endothelial function and, hence, to the development and progression of atherosclerotic cardiovascular disease.

Acetylcholine↗

Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations.

UNLABELLED: The efficiency of a hemodialyzer is largely dependent on its ability to facilitate diffusion, since this is the main mechanism by which small solutes are removed. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. The objective of the paper was to study the impact of different dialysate compartment designs on dialysate flow distribution and urea clearances. Eighteen hollow fiber 1.3 m2 hemodialyzers were studied, 6 each of 3 designs: Type A--standard fiber bundle (PAN 65DX Asahi Medical, Tokyo, Japan); Type B--spacing filaments external to the fibers (PAN 65SF Asahi Medical, Tokyo, Japan); Type C--fibers waved to give Moiré structure (FB130 Nissho-Nipro, Osaka, Japan). IN VITRO STUDIES: 3 dialyzers of each type were studied following dye injection into the dialysate compartment. Dynamic sequential imaging of longitudinal sections of the dialyzer were undertaken, using a new generation helical CT scanner (X-Press/HS1 Toshiba Corporation, Tokyo, Japan). In vivo studies: 3 dialyzers of each type were studied, in randomized sequence, in 3 different patients under standardized dialysis conditions. Blood- and dialysate-side urea clearances were measured at 30 and 150 minutes of treatment. Macroscopic and densitometrical analysis revealed that flow distribution was most homogeneous in the dialyzer with Moiré structure (Type C) and least homogeneous in the standard dialyzer (Type A). Space yarns (Type B) gave an intermediate dialysate flow distribution. Significantly increased urea clearances (p<0.001) were seen with Types B and C, compared to the standard dialyzer. Type C (Moiré) had the highest clearances although these were not significantly greater than Type B (space yarns). In conclusion, more homogeneous dialysate flow distribution and improved small solute clearances can be achieved by use of spacing yarns or waved (Moiré structure) patterns of fiber packing in the dialyzer. These effects are achieved probably as a result of reduced dialysate channeling resulting in a lower degree of mismatch between blood and dialysate flows. The new radiological technique using the helical CT scanner allows detailed flow distribution analysis and has the potential for testing future modifications to dialyzer design.

Equipment Design↗

Immunological changes in peripheral blood and in lymphoid tissue after treatment of HIV-infected subjects with highly active anti-retroviral therapy (HAART) or HAART + IL-2.

This study presents the immunophenotypic and functional analysis of lymphocyte subsets obtained from peripheral blood and lymphoid tissue from HIV+ individuals treated with highly active anti-retroviral therapy (HAART) alone or in combination with 6 million units international (MUI) s.c. IL-2. Before treatment, the HIV+ patients had reduced CD4 and increased CD8 values in the peripheral blood and lymphoid tissue and impaired cytokine production by peripheral blood mononuclear cells (PBMC). After 24 weeks of treatment, all the HIV+ patients demonstrated increased CD4 values in peripheral blood and lymphoid tissue. The use of IL-2 did not promote an additional CD4 expansion compared with HAART alone; increased 'naive' and CD26+ CD4 cells and reduced CD8 cells were found in the peripheral blood and lymphoid tissue of the IL-2-treated, but not of the HAART-treated patients. Both types of treatment induced a significant reduction of the CD8/CD38+ cells. While HAART alone had negligible effects on cytokine production by PBMC, the combined use of HAART + IL-2 was unable to increase the endogenous production of IL-2, but caused an increase of IL-4, IL-13 and interferon-gamma (IFN-gamma) and a reduction of monocyte chemoattractant protein-1 (MCP-1) production. These data suggest that, although in this schedule IL-2 has minimal efficacy on CD4 recovery when compared with HAART alone, it produces an increase of 'naive' and CD26+ CD4 cells and a partial restoration of cytokine production. These data may be used to better define clinical trials aiming to improve the IL-2-dependent immunological reconstitution of HIV-infected subjects.

Adult↗

Myocardial dysfunction and adrenergic cardiac innervation in patients with insulin-dependent diabetes mellitus.

BACKGROUND: Insulin-dependent diabetes mellitus (IDDM) is associated with an increased incidence of heart failure due to several factors, and in some cases a specific cardiomyopathy has been suggested. OBJECTIVES: This study sought to assess the mechanisms of exercise-induced left ventricular (LV) dysfunction in asymptomatic patients with IDDM in the absence of hypertensive or coronary artery disease. METHODS: Fourteen consecutive patients with IDDM were enrolled (10 men, 4 women; mean [+/- SD] age 28.5 +/- 6 years); 10 healthy subjects matched for gender (7 men, 3 women) and age (28.5 +/- 3 years) constituted the control group. LV volume, LV ejection fraction (LVEF) and end-systolic wall stress were calculated by two-dimensional echocardiography at rest and during isometric exercise. LV contractile reserve was assessed by post-extrasystolic potentiation (PESP) obtained by transesophageal cardiac electrical stimulation and dobutamine infusion. Myocardial iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy was performed to assess adrenergic cardiac innervation. RESULTS: Diabetic patients were classified into group A (n = 7), with an abnormal LVEF response to handgrip (42 +/- 7%), and group B (n = 7), with a normal response (72 +/- 8%). Baseline LVEF was normal in both group A and B patients (60 +/- 6% vs. 61 +/- 7%, p = NS). In group A patients, the LV circumferential wall stress-LVEF relation showed an impairment in LVEF disproportionate to the level of LV afterload. No significant changes in LVEF occurred during dobutamine (60 +/- 6% vs. 64 +/- 10%, p = NS), whereas PESP significantly increased LVEF (60 +/- 6% vs. 74 +/- 6%, p < 0.001); PESP at peak handgrip normalized the abnormal LVEF (42 +/- 7% vs. 72 +/- 5%, p < 0.001); and MIBG uptake normalized for body weight or for LV mass was lower than that in normal subjects (1.69 +/- 0.30 vs. 2.98 +/- 0.82 cpm/MBq per g, p = 0.01) and group B diabetic patients (vs. 2.79 +/- 0.94 cpm/MBq per g, p = 0.01). Finally, a strong linear correlation between LVEF at peak handgrip and myocardial MIBG uptake normalized for LV mass was demonstrated in the study patients. CONCLUSIONS: Despite normal contractile reserve, a defective blunted recruitment of myocardial contractility plays an important role in determining exercise LV dysfunction in the early phase of diabetic cardiomyopathy. This abnormal response to exercise is strongly related to an impairment of cardiac sympathetic innervation.

3-Iodobenzylguanidine↗

Effects of subcutaneous interleukin-2 therapy on CD4 subsets and in vitro cytokine production in HIV+ subjects.

HIV infection is characterized by the reduction of the CD4+, CD45RA+, CD26+, and CD28+ lymphocyte subsets and of the in vitro production of IL-2, IL-4, and interferon-gamma; on the contrary, chemokine production is usually increased. These abnormalities are only partially restored by antiretroviral chemotherapy. Therapy with interleukin-2 has been proposed to restore the functions of the immune system, but the mechanisms by which IL-2 exerts its activities are unknown. The aim of this study was to define the effects of rIL-2 administration on CD4+, CD45RA+, CD45R0+, and CD26+ lymphocytes and on the in vitro production of IL-2, IL-4, IL-10, IFN-gamma, RANTES, and sCD30 in HIV+ patients. 10 HIV+ patients with CD4 cell counts between 200 and 500 cells/mm3 were treated with six cycles of subcutaneous recombinant IL-2 administration, in combination with zidovudine and didanosine. This therapeutic regimen resulted in a remarkable increase in the number of CD4+ cells and in the prolonged reduction of the levels of viremia. CD45R01 cells were expanded during the first cycle of therapy, while CD45RA+/CD26+ cells predominated after the third cycle. At this time, the in vitro production of IL-2, IL-4, IFN-gamma, and sCD30 were significantly upregulated. These results demonstrate that rIL-2 in HIV+ patients induces the reconstitution of the CD4/CD45RA lymphocytes subtype. This expanded cell population recovered the ability to produce in vitro IL-2, IL-4, and IFN-gamma. These effects may be beneficial to HIV+ patients by improving their immune response to microorganisms or vaccines.

CD4 Lymphocyte Count↗