PubMed Health⌕ Search

Biomedical subjects

C D Fraser

Publications and source records attributed to C D Fraser.

At least 37 records · Page 2Linked to original sources

Impact of membrane oxygenators on pulsatile versus nonpulsatile perfusion in a neonatal model.

We investigated the effects of two new hollow-fiber membrane oxygenators, the Capiox SX10 and the Lilliput 901, on pulsatile versus nonpulsatile perfusion in an in vitro model designed to simulate a 3 kg infant. The experiments were divided into eight groups (six pulsatile and two nonpulsatile), according to the equipment and settings used. Each group included six tests. In all experiments, the pseudo-patient's mean arterial pressure was 40 mmHg, and the pump flow rate was 550 ml/min. During pulsatile cardiopulmonary bypass, the pump's base flow was set at 30%, and the pump rate was set at 80, 100, 120, 140, or 150 beats/min. The PUMP START and PUMP STOP timing points were adjusted to produce different pulse-width settings. We were especially interested in evaluating the pre- and postoxygenator extracorporeal circuit pressure (ECP), the oxygenator pressure drop, and the precannula ECP. When used with a pulsatile roller pump, the Capiox produced a significantly lower preoxygenator ECP than the Lilliput (p < 0.001); moreover, the Capiox yielded a significantly lower oxygenator pressure drop (p < 0.001). During nonpulsatile perfusion, the Capiox again produced a lower preoxygenator ECP than the Lilliput (p < 0.001). These results suggest that the Capiox may be more suitable than the Lilliput when the pulsatile flow is employed, and pulsatile flow does not increase the ECP with either oxygenator.

Equipment Design↗

Neonatal arterial switch operation for transposition of the great arteries in a patient with mirror image dextrocardia and situs inversus totalis.

The neonatal arterial switch operation has become the standard therapy for D-transposition of the great arteries in the absence of left ventricular outflow tract obstruction. We describe our experience of successful arterial switch operation after balloon atrial septostomy in a 5-day-old infant girl who had atrial and visceral situs inversus totalis, mirror image dextrocardia, and D-transposition of the great arteries. To our knowledge, ours is the first report of this operation in a patient with this anatomy.

Dextrocardia↗

Early initiation of peritoneal dialysis after surgical repair of congenital heart disease.

The mortality rate of infants who require renal replacement therapy after surgical repair of congenital heart disease has been reported to be 30%-79%. We report our experience with early initiation of continuous manual peritoneal dialysis (CPD) to treat fluid overload in 20 consecutive critically ill children who underwent CPD post cardiotomy. CPD catheters were inserted at the discretion of the cardiothoracic surgeon. CPD was started for evidence of total body fluid overload with inadequate urine output, and stopped when negative fluid balance was achieved and urine output improved. Median age was 10 days (range 3-186 days), mean time to start CPD post-operatively was 22 h (range 5-40 h), and mean duration of CPD was 50 h (range 13-92 h). CPD resulted in mean ultrafiltration of 93 ml/kg per day (range 43-233 ml/kg per day). Net negative fluid balance was 106 ml/kg per day (range 49-273 ml/kg per day). During CPD, the mean number of inotropes decreased from 2.2 to 1.6 (P<0.05) and urine output increased from 2.2 to 3.9 ml/kg per hour (P<0.01). No patient died during CPD or had CPD discontinued due to adverse hemodynamic effects. The overall mortality rate was 20%. We conclude that early initiation of CPD can safely and effectively promote fluid removal in infants after repair of congenital heart disease, with a lower mortality rate than has previously been reported.

Adolescent↗

Effects of perfusion mode on regional and global organ blood flow in a neonatal piglet model.

BACKGROUND: Organ injury (brain, kidney, and heart) has been reported in up to 30% of pediatric open heart surgery patients after conventional hypothermic non-pulsatile cardiopulmonary bypass (CPB) support with or without deep hypothermic circulatory arrest (DHCA). The effects of pulsatile (with a Food and Drug Administration approved modified roller pump) versus non-pulsatile perfusion on regional and global cerebral, renal, and myocardial blood flow were investigated during and after CPB with 60 minutes of DHCA in a neonatal piglet model. METHODS: Piglets, mean weight 3 kg, were used in both pulsatile (n = 7) and non-pulsatile (n = 7) groups. After initiation of CPB, all animals were subjected to hypothermia for 25 minutes, reducing the rectal temperatures to 18 degrees C, 60 minutes of DHCA followed by 10 minutes of cold reperfusion and 40 minutes of rewarming with a pump flow of 150 mL/kg/min. During cooling and rewarming, alpha-stat acid-base management was used. Differently labeled radioactive microspheres were injected pre-CPB, on normothermic CPB, pre-DHCA, post-DHCA, and after CPB to measure the regional and global cerebral, renal, and myocardial blood flows. RESULTS: Global cerebral blood flow was significantly higher in the pulsatile group compared to the non-pulsatile group at normothermic CPB (100.4 +/- 6.3 mL/100 gm/min versus 70.2 +/- 8.1 mL/100 gm/min, p < 0.05) and pre-DHCA (77.2 +/- 5.2 mL/100 gm/min versus 56.1 +/- 6.7 mL/100 gm/min, p < 0.05). Blood flow in cerebellum, basal ganglia, brain stem, and right and left cerebral hemispheres had an identical pattern with the global cerebral blood flow. Renal blood flow appeared higher in the pulsatile group compared to the non-pulsatile group during CPB, but the results were statistically significant only at post-CPB (94.8 +/- 9 mL/100 gm/min versus 22.5 +/- 22 mL/100 gm/min, p < 0.05). Pulsatile flow better maintained the myocardial blood flow compared to the non-pulsatile flow after CPB (316.6 +/- 45.5 mL/100 gm/min versus 188.2 +/- 19.5 mL/100 gm/min, p < 0.05). CONCLUSIONS: Pulsatile perfusion provides superior vital organ blood flow compared to non-pulsatile perfusion in this model.

Animals↗

The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model.

Blood trauma increases blood viscoelasticity by increasing red cell aggregation and plasma viscosity and by decreasing cell deformability. During extracorporeal circulation, the mode of perfusion (pulsatile or nonpulsatile) may have a significant impact on blood trauma. In this study, a hydraulically driven dual chamber pulsatile pump system was compared to a standard nonpulsatile roller pump in terms of changes in the blood viscosity and elasticity during cardiopulmonary bypass (CPB) and pre and post deep hypothermic circulatory arrest (DHCA). Piglets, with an average weight of 3 kg, were used in the pulsatile (n = 5) or nonpulsatile group (n = 5). All animals were subjected to 25 min of hypothermia, 60 min of DHCA, 10 min of cold reperfusion, and 40 min of rewarming with a pump flow of 150 ml/kg/min. A pump rate of 150 bpm, pump ejection time of 120 ms, and stroke volume of 1 ml/kg were used during pulsatile CPB. Arterial blood samples were taken pre-CPB (36 degrees C), during normothermic CPB (35 degrees C), during hypothermic CPB (25 degrees C), pre-DHCA (18 degrees C), post-DHCA (19 degrees C), post-rewarming (35 degrees C), and post-CPB (36 degrees C). Viscosity and elasticity were measured at 2 Hz and 22 degrees C and at strains of 0.2, 1, and 5 using the Vilastic-3 Viscoelasticity Analyzer. Results suggest that the dual chamber neonate-infant pulsatile pump system produces less blood trauma than the standard nonpulsatile roller pump as indicated by lower values of both viscosity and elasticity during CPB support.

Animals↗

Defining pulsatile perfusion: quantification in terms of energy equivalent pressure.

Several clinical and animal studies have demonstrated that pulsatile perfusion is more beneficial than nonpulsatile perfusion during short or long durations of extracorporeal circulation. Other investigators, however, have been unable to document these benefits. The issue remains controversial. Central to the debate is the issue of a precise definition of pulsatile flow. To help resolve the conflict, pulsatile flow may be quantified in terms of energy equivalent pressure. This formula contains both the arterial pressure and pump flow rate, which are the 2 most critical parameters for open heart surgery. This definition establishes common criteria for assessment of the effectiveness of extracorporeal support.

Adult↗

A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients.

UNLABELLED: Transesophageal echocardiography (TEE) and central venous catheter (CVC) placement are often used during congenital cardiac surgery. Complications of CVC placement include cardiac perforation, inadvertent arterial placement, and erroneous hemodynamic data from unrecognized malposition. In this study, we used a prospective, randomized, controlled design to evaluate the use of TEE to guide depth of insertion and confirm superior vena cava cannulation, and to improve the percentage of correctly placed CVCs and reduce complications of CVC placement. One hundred forty-five patients were studied. Eighty patients were randomized to have subclavian vein insertion, 64 to have internal jugular insertion, and 1 to have external jugular insertion of CVC. TEE-guided CVC placement resulted in 100% correct placement when assessed by preoperative TEE, versus 86% in the control group (72 of 72 vs. 63 of 73; P = 0.01). There was no difference in correct placement between the two groups when assessed by postoperative chest radiograph (81.9% TEE versus 75.3% control; P = not significant). One significant complication, a superior vena cava perforation, occurred in the control group. Time to placement was 9.6 min in the TEE group versus 8.0 min in the control group (P = 0.015). IMPLICATIONS: Transesophageal echocardiography can be used to guide central venous catheter placement in congenital heart surgery. Central venous catheters that seem to be located high in the right atrium by chest radiograph in these patients are often actually in the superior vena cava and pose little risk of cardiac perforation.

Adolescent↗

Customized perfusion circuit for the tiny ascending aorta.

Cannulating a pediatric patient with an interrupted aortic arch presents many challenges. Two cannulas are necessary to allow for proper blood flow to the head and to the extremities. This case was made more difficult by the weight of the child and the small size of the ascending aorta. The available pediatric cannulas were too large. The perfusionist adapted two 14-gauge intravenous (i.v.) catheters as arterial cannulas which were incorporated into the 1/4-inch arterial line. The 14-gauge i.v. catheters worked successfully. While on cardiopulmonary bypass, the patient was both metabolically and hemodynamically stable. The patient survived the procedure and was eventually discharged from hospital.

Aorta↗

Technical considerations for valve repair in patients with congenital heart disease.

Valve repair is a critical element in the surgical treatment of congenital heart disease. Growing children require a longitudinal management strategy not commonly necessary in adult cardiac surgery. The use of valve prostheses poses unique problems in children, not only due to size limitations, but also to difficulties with chronic medical management. For these reasons, considerable effort is given to repairing even severely malformed valves in pediatric patients. This article provides a brief overview of some commonly used techniques in reparative valve surgery in children.

Aortic Valve Insufficiency↗

Right-to-left interatrial shunt after pneumonectomy.

BACKGROUND: Platypnea and Orthodeoxia have been described with congenital heart and severe lung diseases. METHODS: We report 4 patients in whom platypnea and orthodeoxia developed after pneumonectomy. In these patients the mean oxygen saturation on room air was 65% (range, 45% to 79%) in the supine position. On O2 therapy it improved to 94% (range, 80% to 99%). When the patients assumed the erect position and were receiving O2 therapy the saturation dropped to a mean of 76% (range, 56% to 82%) and the patients complained of shortness of breath. Cardiac catheterization revealed a mean pulmonary capillary wedge pressure of 11.6 mm Hg (range, 7 to 18 mm Hg). All patients had normal right atrial pressure. A right-to-left interatrial shunt through a patent foramen ovale was documented by transesophageal echocardiography and dynamic ultrafast magnetic resonance imaging. The patients underwent surgical closure of the patent foramen ovale. RESULTS: In the erect position, the room air O2 saturation improved to a mean of 95% (range, 92% to 99%), and the shortness of breath disappeared. CONCLUSIONS: Postpneumonectomy patients complaining of shortness of breath should be assessed for platypnea and orthodeoxia. A right-to-left interatrial shunt through a patent foramen ovale can occur even in the absence of elevated right heart pressures, especially after right pneumonectomy, and is accentuated in the upright posture. Surgical correction of the patent foramen ovale can produce dramatic improvement.

Aged↗

Correction of anomalous systemic venous drainage in heterotaxy syndrome.

A 3-month-old patient with heterotaxy syndrome, complex intracardiac malformations, and severe heart failure underwent surgical correction. Anatomy included an interrupted inferior vena cava with hemiazygous continuation to a persistent left superior vena cava draining to the left atrium. The presence of partial anomalous pulmonary venous drainage precluded an intraatrial baffle. Systemic venous reconstruction was achieved using the left atrial appendage along with an intracardiac repair of the other defects.

Heart Defects, Congenital↗

Ross-Konno procedure with interrupted aortic arch repair in a premature neonate.

A 1,700-g premature baby who presented with interrupted aortic arch type B, hypoplastic aortic annulus, severe subaortic stenosis, and large ventricular septal defect underwent successful surgical repair. A Ross-Konno operation was used to address the left ventricular outflow tract obstruction, hypoplastic aortic annulus, and ventricular septal defect. The interruption was repaired with a direct anastomosis.

Abnormalities, Multiple↗