PubMed Health⌕ Search

Biomedical subjects

C Daniel Johnson

Publications and source records attributed to C Daniel Johnson.

12 recordsLinked to original sources

Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy--feasibility study.

A feasibility study was conducted to evaluate two biphasic computed tomographic (CT) enterography protocols, a noninvasive CT technique with water administered perorally and CT enteroclysis with methylcellulose administered through a nasojejunal tube, in 23 patients known or suspected to have Crohn disease. Results were compared with the results of fluoroscopic small bowel examination and terminal ileoscopy for the detection of active Crohn disease in the terminal ileum. Luminal distention did not differ significantly between the two CT protocols. Arterial phase imaging was noncontributory in 22 of 23 cases. The noninvasive peroral water CT enterography protocol had similar accuracy (12 of 15 cases, 80%) for enabling the detection of active Crohn disease in comparison with CT enteroclysis with nasojejunal tube (seven of eight, 88%) and fluoroscopic small bowel examination (17 of 23, 74%). No fistulas were missed with use of either CT technique. The authors conclude that noninvasive peroral portal venous phase CT enterography with use of water is an accurate and feasible technique for detecting active small bowel inflammation in patients with Crohn disease.

Administration, Oral↗

Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps.

BACKGROUND & AIMS: This study used a low lesion prevalence population reflective of the screening setting to estimate the sensitivity and specificity of computerized tomographic (CT) colonography for detection of colorectal polyps. METHODS: This prospective, blinded study comprised 703 asymptomatic persons at higher-than-average risk for colorectal cancer who underwent CT colonography followed by same-day colonoscopy. Two of 3 experienced readers interpreted each CT colonography examination. RESULTS: Overall lesion prevalence for adenomas >/=1 cm in diameter was 5%. Seventy percent of all lesions were proximal to the descending colon. With colonoscopy serving as the gold standard, CT colonography detected 34%, 32%, 73%, and 63% of the 59 polyps >/=1 cm for readers 1, 2, 3, and double-reading, respectively; and 35%, 29%, 57%, and 54% of the 94 polyps 5-9 mm for readers 1, 2, 3, and double-reading, respectively. Specificity for CT colonography ranged from 95% to 98% and 86% to 95% for >1 cm and 5-9-mm polyps, respectively. Interobserver variability was high for CT colonography with kappa statistic values ranging from -0.67 to 0.89. CONCLUSIONS: In a low prevalence setting, polyp detection rates at CT colonography are well below those at colonoscopy. These rates are less than previous reports based largely on high lesion prevalence cohorts. High interobserver variability warrants further investigation but may be due to the low prevalence of polyps in this cohort and the high impact on total sensitivity of each missed polyp. Specificity, based on large numbers, is high and exhibits excellent agreement among observers.

Aged↗

Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting.

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.

Colonic Neoplasms↗

Extracolonic findings at CT colonography: evaluation of prevalence and cost in a screening population.

BACKGROUND & AIMS: To assess the prevalence and spectrum of extracolonic findings in a screening population undergoing computed tomography colonography (CTC), and to evaluate the short-term direct medical costs incurred from subsequent radiologic follow-up evaluation. METHODS: Six hundred and eighty-one asymptomatic patients undergoing colonoscopy screening consented to a CTC examination. Extracolonic CT findings were classified into high, medium, and low importance. Clinical and radiologic follow-up, missed lesions, and outcomes were assessed by chart review (time interval, 410-1513 days; median, 913 days). Short-term direct medical costs of radiologic follow-up were determined based on Medicare 2002 reimbursement rates. RESULTS: Extracolonic findings were found commonly. These were categorized as high clinical importance in 71 (10%) individuals, as medium importance in 183 individuals (27%), and as low importance in 341 individuals (50%). Subsequent medical or surgical interventions resulted from these findings in 9 of the 681 patients (1.3%). Costs of subsequent radiologic follow-up studies were calculated as $23,380.59 (average added costs per CTC examination $34.33). CONCLUSIONS: CTC commonly detects extracolonic findings that can be considered clinically important when applied to an asymptomatic screening population. Although such incidental findings add benefit to the screening intervention, moderate incremental costs are incurred based on additional radiologic procedures generated during short-term follow-up.

Adult↗

Computer-assisted detection of colonic polyps with CT colonography using neural networks and binary classification trees.

Detection of colonic polyps in CT colonography is problematic due to complexities of polyp shape and the surface of the normal colon. Published results indicate the feasibility of computer-aided detection of polyps but better classifiers are needed to improve specificity. In this paper we compare the classification results of two approaches: neural networks and recursive binary trees. As our starting point we collect surface geometry information from three-dimensional reconstruction of the colon, followed by a filter based on selected variables such as region density, Gaussian and average curvature and sphericity. The filter returns sites that are candidate polyps, based on earlier work using detection thresholds, to which the neural nets or the binary trees are applied. A data set of 39 polyps from 3 to 25 mm in size was used in our investigation. For both neural net and binary trees we use tenfold cross-validation to better estimate the true error rates. The backpropagation neural net with one hidden layer trained with Levenberg-Marquardt algorithm achieved the best results: sensitivity 90% and specificity 95% with 16 false positives per study.

Algorithms↗

Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: prospective assessment of patient perceptions and preferences.

PURPOSE: To prospectively assess and compare perceptions of and preferences for computed tomographic (CT) colonography, colonoscopy, and double-contrast barium enema examination (DCBE) by asymptomatic patients undergoing colorectal cancer screening. MATERIALS AND METHODS: A total of 696 asymptomatic patients at higher-than-average risk undergoing colorectal cancer screening were consecutively recruited to undergo both CT colonography and colonoscopy (group 1), and a like group of 617 patients was separately recruited to undergo both CT colonography and DCBE (group 2). Standard bowel preparations were different between the groups undergoing colonoscopy and DCBE. Each patient completed a questionnaire that assessed preparation inconvenience and discomfort, examination discomfort, willingness to repeat examinations, and examination preference. Survey results were compared for significance by using the Wilcoxon rank sum or chi2 test. RESULTS: The majority of patients considered the preparation to be uncomfortable (group 1, 460 of 515 [89%]; group 2, 482 of 538 [90%]) and inconvenient (group 1, 393 of 502 [78%]; group 2, 427 of 527 [81%]). Reported discomfort was similar at CT colonography and colonoscopy (P =.63) but was less at CT colonography than at DCBE (P <.001). Patients experienced significantly less discomfort than expected at both CT colonography and colonoscopy but not at DCBE. Patients' willingness to undergo frequent rescreening was significantly greater for CT colonography than for either colonoscopy or DCBE. The acceptable time interval between screenings was significantly shorter for all examinations if the bowel preparation could be avoided. Overall, patients preferred CT colonography to colonoscopy (group 1, 72.3% vs 5.1%; P <.001) or to DCBE (group 2, 97.0% vs 0.4%; P <.001). CONCLUSION: Patients undergoing colorectal cancer screening prefer CT colonography to both colonoscopy and DCBE. The majority of patients experience discomfort and inconvenience with cathartic bowel preparation.

Adult↗

Pancreatic malignancy: value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT.

PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P < or =.008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion.

Adenocarcinoma↗

Primary hepatic angiosarcoma: findings at CT and MR imaging.

PURPOSE: To evaluate and describe cross-sectional imaging findings in patients with pathologically confirmed primary hepatic angiosarcoma. MATERIALS AND METHODS: Findings from imaging examinations in 13 patients with pathologically confirmed primary hepatic angiosarcoma were retrospectively reviewed (computed tomographic [CT] images obtained in 10 patients and magnetic resonance [MR] images obtained in five patients were available for review). Two gastrointestinal radiologists evaluated lesion number, size, attenuation and signal intensity characteristics, and the pattern and degree of contrast material enhancement. Medical records were reviewed for clinical features associated with angiosarcoma. RESULTS: Angiosarcoma appeared as multiple nodules (n = 6), as dominant masses (n = 6), or as a diffusely infiltrating lesion (n = 1). Multiple nodules were hypoattenuating at unenhanced and contrast material--enhanced CT (six of six patients). When dominant masses were encountered at MR imaging, T2-weighted MR imaging demonstrated heterogeneous internal architecture (four of four patients) similar to that of hepatocellular carcinoma. Multiphase contrast-enhanced CT and MR images showed dominant masses to have heterogeneous and progressive enhancement (three of three patients). Clinical features associated with angiosarcoma included splenic metastases (six of 13 patients), thrombocytopenia (seven of 13 patients), disseminated intravascular coagulation (four of 13 patients), and hemolytic anemia (three of 13 patients). CONCLUSION: Primary hepatic angiosarcoma exhibits a spectrum of appearances that reflect its varied pathologic features.

Adult↗

Colonic polyps: complementary role of computer-aided detection in CT colonography.

PURPOSE: To apply a computer-aided detection (CAD) algorithm to supine and prone multisection helical computed tomographic (CT) colonographic images to confirm if there is any added benefit provided by CAD over that of standard clinical interpretation. MATERIALS AND METHODS: CT colonography (with patients in both supine and prone positions) was performed with a multisection helical CT scanner in 40 asymptomatic high-risk patients. There were two consecutive series of patients, 20 of whom had at least one polyp 1.0 cm in size or larger and 20 of whom had normal colons at conventional colonoscopy performed the same day. The CT colonographic images were interpreted with an automated CAD algorithm and by two radiologists who were blinded to colonoscopy findings. RESULTS: For 25 polyps at least 1.0 cm in size ("large" polyps), sensitivity for detection by at least one radiologist was 48% (12 of 25). The sensitivity of CAD for detecting large polyps was also 48% (12 of 25), but the CAD algorithm detected four of 13 large polyps that were not detected by either radiologist (31%, 95% two-sided CI: 9, 61), increasing the potential sensitivity to 64% (16 of 25). For polyps identifiable retrospectively, sensitivity of CAD was 67% (12 of 18), and sensitivity of the combination of detection with the CAD algorithm or by at least one radiologist was 89% (16 of 18). There were an average of 11 false-positive detections per patient for CAD. CONCLUSION: In this series of patients in whom radiologists had difficulties detecting polyps (compared with sensitivities of 75%-90% reported in the literature), this CAD algorithm played a complementary role to conventional interpretation of CT colonographic images by detecting a number of large polyps missed by trained observers.

Aged↗

Contrast-enhanced CT colonography in recurrent colorectal carcinoma: feasibility of simultaneous evaluation for metastatic disease, local recurrence, and metachronous neoplasia in colorectal carcinoma.

OBJECTIVE: Contrast-enhanced CT colonography has the potential to detect local recurrence, metachronous disease, and distant metastases in patients with a history of invasive colorectal cancer. The purpose of our study was to determine whether colonic anastomoses prohibit adequate colonic distention on contrast-enhanced CT colonography and to estimate the performance of contrast-enhanced CT colonography in detecting recurrent colorectal carcinoma. MATERIALS AND METHODS: Fifty patients with a history of resected invasive colorectal carcinoma underwent contrast-enhanced CT colonography and colonoscopy. Colonic distention was graded for different colonic segments. Two radiologists evaluated for the presence of local recurrence, metachronous disease, and metastatic disease. Results were compared with colonoscopy, histology, and clinical follow-up. RESULTS: Most patients had adequate colonic inflation (37/50, 74%). Eleven of 13 patients with inadequate distention had collapse in the sigmoid colon, usually associated with ileocolic anastomoses. Contrast-enhanced CT colonography detected local recurrences with an accuracy of 94% (95% confidence interval, 83-99%). The accuracy of contrast-enhanced CT colonography for metachronous lesions greater than or equal to 1 cm was 92% (95% confidence interval, 80-98%), but there was only one such lesion, which was missed on initial colonoscopy. Stool, granulation tissue, and inflammation can mimic the CT appearance of local recurrence or metachronous disease and account for false-positive examinations. Contrast-enhanced CT colonography identified five patients with metastatic disease. CONCLUSION: Suboptimal sigmoid distention can be seen on contrast-enhanced CT colonography, predominantly in patients with right hemicolectomies. Contrast-enhanced CT colonography is a promising method for detecting local recurrence, metachronous disease, and distant metastases in patients with prior invasive colorectal carcinoma. The technique can also serve as a useful adjunct to colonoscopy by detecting local recurrences or metachronous disease that are endoscopically obscure or by serving as a full structural colonic examination when endoscopy is incomplete.

Adult↗

Computer-aided detection of polyps in a colon phantom: effect of scan orientation, polyp size, collimation, and dose.

PURPOSE: To determine the importance of polyp size, orientation to the scan plane, collimation, scanner type (single or multislice helical), and radiation dose on computed tomography (CT) colonography computer-aided detection. MATERIALS AND METHODS: Eight tissue-equivalent simulated polyps were placed into the interior of an air-filled acrylic tube placed within a water-filled box. Their sizes, expressed by diameter and height in millimeters, were 10 x 10, 10 x 7, 10 x 5, 10 x 3, 7 x 7, 7 x 5, 7 x 3, and 5 x 5. Detection of the polyps was performed by applying our prototype automated polyp detector software to 48 CT colonography data sets of the phantom acquired with different CT scanner settings. RESULTS: We detected at least six of the eight polyps in 47 of 48 experiments. The two most frequently undetected polyps (7 x 7 and 5 x 5) had extreme eccentricity (their height was twice the radius of the base) and were most commonly missed for 90 degrees tube orientation, 5-mm collimation, and high table speed. False-positive detections occurred in only 5 of 48 experiments. CONCLUSION: Clinically significant 10-mm polyps can be detected with 100% sensitivity in all orientations, doses, collimations, and modes that we examined.

Artifacts↗