Myocardial perfusion and function single photon emission computed tomography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C David Cooke.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
UNLABELLED: A renal expert system (RENEX) has been developed to assist physicians detect renal obstruction in patients undergoing pre- and postfurosemide 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) scans. RENEX uses quantitative parameters extracted from the dynamic renal scan data and heuristic rules in the form of a knowledge base (KB) obtained from expert interpreters to conclude whether a kidney is obstructed. METHODS: Normal limits were established for 47 quantitative parameters extracted from the 99mTc-MAG3 scans of 100 potential renal donors. From these data the domain expert estimated 5 boundary conditions for each parameter: (i) definitely abnormal, (ii) probably abnormal, (iii) equivocal, (iv) probably normal, and (v) definitely normal. A sigmoid-type curve was then generated from these 5 boundary conditions, creating a parameter knowledge library used for converting the value of a prospective patient's individual quantitative parameters to a certainty factor (CF). Sixty heuristic rules were extracted from the domain expert to generate the KB for detecting obstruction. A forward-chaining inference engine was developed using the MYCIN combinatories (an approximation of Bayes theorem) to determine obstruction. A justification engine was implemented, which recorded the sequence of each rule that was fired and the current CF value of all input and output parameters at the time of instantiation to track and justify the logic of the conclusions. The entire system was fine tuned and tested using a pilot group of 32 patients (11 males, 21 females; mean age, 56.8 +/- 17.2 y; 63 kidneys) deemed by an expert panel to have 41 unobstructed kidneys, 13 obstructed kidneys,and 9 equivocal findings. RESULTS: RENEX agreed with the expert panel in 92% (12/13) of the obstructed kidneys, 93% (38/41) of the unobstructed kidneys, and 78% (7/9) of the kidneys interpreted as equivocal for obstructions. Processing time per patient was practically instantaneous using a 3.0-GHz personal computer programmed using interactive data language. CONCLUSION: We have developed a renal expert system for detecting renal obstruction using pre- and postfurosemide 99mTc-MAG3 renal scans, at a standardized expert level. These encouraging preliminary results warrant a prospective study in a large population of patients with and without renal obstruction to establish the diagnostic performance of this system.
BACKGROUND: Cardiac gating is not routinely used in cardiac positron emission tomography (PET). The aim of this study was to determine the feasibility of assessing regional wall motion, ejection fraction (EF), cardiac volumes, and mass with nitrogen-13 ammonia (N-13 ammonia) at the time of PET myocardial perfusion imaging. METHODS: We studied 12 healthy volunteers (mean age, 28 +/- 8 years) and 53 patients with documented coronary artery disease (CAD) (mean age, 59 +/- 11 years). All subjects received a single administration of approximately 600 MBq (16 mCi) of N-13 ammonia intravenously. A 6-minute dynamic scan was performed for quantitative assessment of myocardial perfusion at rest, followed by a separate, 13-minute static scan acquired in the gated mode (8 equal bins). Gated data was imported into the Emory Toolbox. Wall motion was evaluated by dividing the myocardium into 9 anatomic regions graded semiquantitatively. RESULTS: Healthy volunteers had a normal EF (61 +/- 6), end systolic volume (ESV) (37 +/- 15 mL), end diastolic volume (EDV) (89 +/- 25 mL), and cardiac mass (116 +/- 18 g). In contrast, patients with CAD showed reduced EF (32 +/- 13%) and increased ESV (129 +/- 56 mL), EDV (188 +/- 68 mL), and cardiac mass (173 +/- 45 g) (P < 0.001 for each). In patients with CAD, EF measured by gated PET correlated significantly to independent measurements of EF (P < 0.001). CONCLUSIONS: Gating of cardiac perfusion images obtained after administration of N-13 ammonia is feasible and appears to be an accurate means of evaluating regional and global cardiac function. Gating can provide important additional diagnostic and prognostic information.
OBJECTIVE: We hypothesize that ECG-gated positron emission tomography (PET) using Fluorodeoxyglucose F-18 (FDG) alone can determine myocardial viability by identifying dysfunctional myocardium with preserved glucose metabolism. We compared the contraction-metabolism pattern of gated FDG PET with the perfusion-metabolism pattern of conventional PET using N-13 ammonia (NH(3)) as a perfusion agent and FDG as a glucose metabolism agent in 21 consecutive patients with chronic coronary artery disease with left ventricular dysfunction (mean ejection fraction 23.6 +/- 7.7%).METHODS: The left ventricle was divided into 17 segments. Uptakes of NH(3) and FDG were scored from absent (0) to normal (4), and wall motion was scored from dyskinesia (-1) to normal (3). Scores were determined by the visual interpretation of the majority of 3 blinded expert readers. Viable myocardium was defined by normal or mildly reduced uptakes of both NH(3) and FDG, perfusion-metabolism mismatch on NH(3)-FDG PET, or normal to mildly reduced uptake of FDG with regional dysfunction on gated FDG PET.RESULTS: Gated FDG PET identified 184 segments as viable, all of which were determined as viable by NH(3)-FDG PET. Among 125 segments identified as nonviable by NH(3)-FDG PET, 76 segments were determined as nonviable by NH(3)-FDG PET. The results provided a positive and negative predictive value of gated FDG PET for the determination of myocardial viability to be 100% and 60.8%, respectively.CONCLUSIONS: Gated FDG PET has a high positive predictive value (100%) for the identification of viable myocardium.
BACKGROUND: A count-based method using technetium-99m sestamibi electrocardiography-gated myocardial perfusion single photon emission computed tomography imaging has been developed to extract the left ventricular (LV) regional phase of contraction (onset of mechanical contraction [OMC]) throughout the cardiac cycle. This study was performed to develop OMC normal databases and dynamic OMC displays for assessment of cardiac mechanic dyssynchrony. METHODS AND RESULTS: LV regional phases were extracted from 90 enrolled normal subjects (45 men and 45 women) by use of the Emory Cardiac Toolbox and then submitted to statistical analysis to generate the normal databases. The LV OMC wave was dynamically propagated over the perfusion polar map by blackening either sequential phase bins or all past phases. The developed OMC normal databases consisted of peak phase (134.5 degrees +/- 14.3 degrees for men and 140.2 degrees +/- 14.9 degrees for women), phase SD (14.2 degrees +/- 5.1 degrees for men and 11.8 degrees +/- 5.2 degrees for women), and phase histogram bandwidth (38.7 degrees +/- 11.8 degrees for men and 30.6 degrees +/- 9.6 degrees for women), skewness (4.19 +/- 0.68 for men and 4.60 +/- 0.72 for women), and kurtosis (19.72 +/- 7.68 for men and 23.21 +/- 8.16 for women). Both statistical analysis and dynamic OMC displays were incorporated into a user interface as a diagnostic tool. CONCLUSION: The OMC normal databases and dynamic OMC displays should help clinicians evaluate cardiac mechanic dyssynchrony. Prospective clinical trials are needed to validate whether this tool can be used to select patients with severe heart failure symptoms who might benefit from cardiac resynchronization therapy.
BACKGROUND: The most widely distributed software packages to compute left ventricular (LV) volume and ejection fraction (EF) from gated perfusion tomograms are QGS and the Emory Cardiac Toolbox (ECTb). Because LV modeling and time sampling differ between the algorithms, it is necessary to document relationships between values produced by them and to establish normal limits individually for each software package in order to interpret results obtained for individual patients. METHODS AND RESULTS: Gated single photon emission computed tomography technetium 99m sestamibi myocardial perfusion studies were collected and analyzed for 246 patients evaluated for coronary artery disease. QGS and ECTb values of ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume were found to correlate linearly (r = 0.90, 0.91, and 0.94, respectively), but EF and EDV were significantly lower for QGS than with ECTb (53% +/- 13% vs 61% +/- 13 and 102 +/- 45 mL vs 114 +/- 50 mL, respectively). To compare calculations for healthy subjects between the two software packages, data were also selected for 50 other patients at low likelihood for coronary artery disease, for whom EF and EDV were significantly lower for QGS compared with ECTb (62% +/- 9% vs 67% +/- 8% and 84 +/- 26 mL vs 105 +/- 33 mL, respectively). The ECTb lower limit was 51% for EF and the upper limits were 171 mL for EDV and 59 mL/m(2) for mass-indexed EDV, compared with limits of 44%, 137 mL, and 47 mL/m(2) for QGS. CONCLUSIONS: Although correlations were strong between the two methods of computing LV functional values, statistical scatter was substantial and significant biases and trends observed. Therefore, when both software packages are used at the same site, it will be important to take these differences into consideration and to apply normal limits specific to each set of algorithms.
BACKGROUND: The dynamic twisting component of cardiac motion is not accounted for by radionuclide techniques so that maps of perfusion and wall thickening are motion-blurred by torsion. This study examined whether torsion can be estimated from gated single photon emission computed tomography data and whether torsion corrections affect cardiac measurements. METHODS AND RESULTS: Technetium 99m sestamibi myocardial perfusion gated tomograms were selected retrospectively for 52 patients who had x-ray contrast arteriograms: 12 with normal perfusion (group 1), 12 with abnormal perfusion (group 2), and 28 studied after angioplasty (group 3). The 8 gated perfusion maps were transformed by contrast normalization, the count minimums of which were tracked to quantify torsion. Measured torsion was used to correct maps of perfusion and wall thickening. Torsion was found to be visually detectable equally well in groups 1 and 2. Apical torsion was significantly greater for group 1 than groups 2 and 3 (15 degrees +/- 9 degrees vs 9 degrees +/- 15 degrees and 2 degrees +/- 12 degrees ) and was opposite in sign for patients with apical aneurysms (-4 degrees +/- 13 degrees ) and for patients after coronary artery bypass grafting (CABG) (-4 degrees +/- 15 degrees ). Maximum percent count differences were 10% +/- 16% between torsion-corrected versus uncorrected perfusion maps. The greatest wall thickening differences were seen for patients with left ventricular apical aneurysms and for patients after CABG versus group 1 (10% +/- 6% and 8% +/- 6% vs 3% +/- 1%, respectively). CONCLUSIONS: It is feasible to detect cardiac torsion in the majority of Tc-99m sestamibi myocardial perfusion scans. Abnormal twisting patterns distinguished patients after CABG and those with left ventricular aneurysms from subjects with normal perfusion in a manner similar to magnetic resonance imaging observations.