The impact of rotary blood pump in conjunction with mechanical ventilation on ventricular energetic parameters - numerical simulation.

OBJECTIVES: Aim of this work is to study the impact of left ventricular rotary blood pump assistance, on energetic variables, when mechanical ventilation (MV) of the lungs is applied. METHODS: Computer simulation was used to perform this study. Lumped parameter models reproduce the circulatory system. Variable elastance models reproduce the Starling's law of the heart for each ventricle. After the reproduction of ischemic heart disease left ventricular assistance was applied using a model of rotary blood pump. The pump speed was changed in steps and was assumed to be constant during each step. The influence of mechanical ventilation was introduced by different values of positive mean thoracic pressure. RESULTS: The increase of the rotational speed has a significant influence on some ventricular energetic variables. In fact it decreased left ventricular external work, left and right ventricular pressure-volume area and the left ventricular efficiency. Finally, it increased the right ventricular efficiency but had no influence on the right ventricular external work. The increase of thoracic pressure from -2 to +5 mmHg caused a significant decrease of external work, pressure-volume area (right ventricular pressure-volume area dropped up to 50%) and an increase of right ventricular efficiency (by 40%) while left ventricular efficiency remained almost stable. CONCLUSIONS: Numerical simulation is a very suitable tool to predict changes of not easily measurable parameters such as energetic ventricular variables when mechanical assistance of heart and/or lungs is applied independently or simultaneously.

Computer Simulation↗

Modelling in the study of interaction of Hemopump device and artificial ventilation.

The aim of this work is to evaluate in different ventricular conditions the influence of joint mechanical ventilation (MV) and Hemopump assistance. To perform this study, we used a computer simulator of human cardiovascular system where the influence of MV was introduced changing thoracic pressure to positive values. The simulation confirmed that haemodynamic variables are highly sensitive to thoracic pressure changes. On the other hand, Hemopump assistance raises, among the others, mean aortic pressure, total cardiac output (left ventricular output flow plus Hemopump flow) and coronary flow. The simulation showed that the joint action of Hemopump and positive thoracic pressure diminishes these effects.

Air Pressure↗

Development of a hybrid (numerical-hydraulic) circulatory model: prototype testing and its response to IABP assistance.

Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters)are developed in LabVIEW environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.

Analog-Digital Conversion↗

In vivo and simulation study of artificial ventilation effects on energetic variables in cardiosurgical patients.

OBJECTIVES: The analysis of energetic ventricular variable changes during artificial ventilation, obtained by numerical simulation was done. Twenty-one sets of hemodynamic parameters for eight cardiosurgical patients were used to estimate left and right stroke work. The data were collected for three methods of ventilation: conventional, lung-protective (with minute ventilation diminished by half) and high frequency ventilation (with frequency 5, 10, or 15 Hz). METHODS: The computer simulator (CARDIOSIM) of the cardiovascular system, was used as a tool to calculate values of energetic ventricular variables for conditions that corresponded to these during in vivo measurements. Different methods of ventilation caused differences of intrathoracic pressure, haemodynamic and finally energetic ventricular variables. The trends of these variable changes were the same in in vivo and simulation studies, in the whole range of intrathoracic pressure changes (Pt = 1.5-3.5 mmHg). RESULTS: As values of main hemodynamic variables like cardiac output or arterial, systemic and pulmonary pressures were very close in both studies. Cardiac index and left ventricular stroke work also differed less than 10% for all examined patients and computer simulation. In a case of right ventricular stroke work the difference between in vivo data and simulation was a bit greater than 10% for two of eight patients under study. CONCLUSIONS: Our comparative analysis proved that numerical simulation is a very useful tool to predict changes of main hemodynamic and energy-related ventricular variables caused by different levels of positive Pt. It means that it can help an anesthesiologist to choose an appropriate method of artificial ventilation for cardiosurgical patients.

Computer Simulation↗

A simple method for E(max) evaluation: in vitro results.

E(max) is an important parameter to evaluate the state of the heart and of its contractile capability. Its determination is not easy and rather inaccurate: However, it can be clinically relevant during mechanical and/or pharmacological heart assistance as it can suggest how to modify pharmacological therapy or the control strategy of the device. Aim of this study is to develop a method based on ventricular energetics to evaluate E(max). If arterial elastance line slope is modified, for example by a slight peripheral resistance increase, E(max) (assuming that it is constant) can be evaluated computing the energy transferred to the arterial elastance before and after the change. The corresponding equation contains known or easily computable variables and the difference delta between end diastolic volume and ventricular rest volume. If the ratio of deltas before and after the disturbance is near to 1, the equation returns a fair estimation of E(max). The method was tested in vitro, in different circulatory conditions, using an open loop numerical model of the circulation built out of a variable elastance model of the ventricle connected to a modified windkessel representing the systemic arterial tree. The results obtained in in vitro experiments suggest clinically testing this method.

Computer Simulation↗

A hybrid mock circulatory system: development and testing of an electro-hydraulic impedance simulator.

Mock circulatory systems are used to test mechanical assist devices and for training and research purposes; when compared to numerical models, however, they are not flexible enough and rather expensive. The concept of merging numerical and physical models, resulting in a hybrid one, is applied here to represent the input impedance of the systemic arterial tree, by a conventional windkessel model built out of an electro-hydraulic (E-H) impedance simulator added to a hydraulic section. This model is inserted into an open loop circuit, completed by another hybrid model representing the ventricular function. The E-H impedance simulator is essentially an electrically controlled flow source (a gear pump). Referring to the windkessel model, it is used to simulate the peripheral resistance and the hydraulic compliance, creating the desired input impedance. The data reported describe the characterisation of the E-H impedance simulator and demonstrate its behaviour when it is connected to a hybrid ventricular model. Experiments were performed under different hemodynamic conditions, including the presence of a left ventricular assist device (LVAD).

Computer Simulation↗

Modelling of cardiovascular system: development of a hybrid (numerical-physical) model.

Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit--the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.

Coronary Circulation↗

Study of systolic pressure variation (SPV) in presence of mechanical ventilation.

Systolic pressure variation (SPV) and its components (dUp and dDown) have been demonstrated to be of interest in assessing preload in mechanically ventilated patients. The aim of this paper is to analyse the sensitivity of these variables to preload and volemic changes during mechanical ventilation in different conditions of the cardiovascular system. Computer simulation experiments have been done using a modular lumped parameter model of the cardiovascular system. The effect of mechanical ventilation has been reproduced operating on intrathoracic pressure. Experiments have been performed varying preload through filling pressure. Sensitivity of SVP dUp and dDown is described varying separately left ventricular elastance (Ev), systemic arterial resistance (Ras) and systemic arterial compliance (Cas). The sensitivity of SPV and dDown to preload and filling pressure is appreciable for high values of Ev and for a wide variation of Ras. Preliminary clinical data concerning the three parameters show good correlation with simulation results.

Blood Pressure↗

IABP assistance: a test bench for the analysis of its effects on ventricular energetics and hemodynamics.

IABP assistance is frequently used to support heart recovery, improving coronary circulation and re-establishing the balance between oxygen availability and consumption. Hemodynamic and energetic parameters (endocardial viability ratio, ventricular energetics) are used to evaluate its effectiveness which depends on internal (timing, balloon volume and position) and external factors (circulatory conditions). Considering short, medium and long-term effects of IABP, the first depends on its mechanical action, the latter on the changes induced in circulatory parameters. The analysis of the first is important because conditions for the onset of a virtuous cycle able to support ventricular recovery are created. Simulation systems could be helpful in this analysis for the implicit reliability and reproducibility of the experiments, provided that they are able to reproduce both hemodynamic phenomena and energetic relationships. The aim of this paper is to present a system originally developed to test mechanical heart assist devices and modified for IABP testing. Data reported here are obtained from in vitro experiments. A partial verification, obtained from the literature is presented.

Coronary Circulation↗

Mono and bi-ventricular assistance: their effect on ventricular energetics.

When mono- and bi-ventricular mechanical assistance is used for heart recovery, its control strategy and circulatory variables affect ventricular energetics (external work-EW, oxygen consumption-VO2, cardiac mechanical efficiency-CME). This study is based on the data obtained in vitro and presents an analysis of the effects of the mono- and bi-ventricular mechanical assistance on ventricular energetics. The assistance was conducted on the principle of counterpulsation with atrio-arterial connection. It includes the following stages: 1) the characterisation of the isolated ventricle model in terms of EW, VO2 and CME as a function of the filling pressure and peripheral resistance, 2) modelling of left ventricular and pulmonary dysfunction, followed by left ventricular and bi-ventricular assistance. Experimental data enable us to draw the following conclusions: * in general, the greatest hemodynamic improvement does not correspond to the highest energetic improvement, * LVAD assistance deteriorates left ventricular CME while its effect on right ventricular energetics depends on the value of right ventricular elastance (Emax). Right ventricular CME is deteriorated by BVAD assistance irrespective of right Emax, * the energetics optimisation in bi-ventricular assistance is closely related to the right Emax, which could probably be a deciding factor in the choice of the assistance mode.

Elasticity↗

A hybrid (numerical-physical) model of the left ventricle.

Hydraulic models of the circulation are used to test mechanical devices and for training and research purposes; when compared to numerical models, however, they are not flexible enough and rather expensive. The solution proposed here is to merge the characteristics and the flexibility of numerical models with the functions of physical models. The result is a hybrid model with numerical and physical sections connected by an electro-hydraulic interface - which is to some extent the main problem since the numerical model can be easily changed or modified. The concept of hybrid model is applied to the representation of ventricular function by a variable elastance numerical model. This prototype is an open loop circuit and the physical section is built out of a reservoir (atrium) and a modified windkessel (arterial tree). The corresponding equations are solved numerically using the variables (atrial and arterial pressures) coming from the physical circuit. Ventricular output flow is the computed variable and is sent to a servo amplifier connected to a DC motor-gear pump system. The gear pump, behaving roughly as a flow source, is the interface to the physical circuit. Results obtained under different hemodynamic conditions demonstrate the behaviour of the ventricular model on the pressure-volume plane and the time course of output flow and arterial pressure.

Heart Ventricles↗

Computer simulation of haemodynamic parameters changes with left ventricle assist device and mechanical ventilation.

Left Ventricular Assist Device is used for recovery in patients with heart failure and is supposed to increase total cardiac output, systemic arterial pressure and to decrease left atrial pressure. Aim of our computer simulation was to assess the influence of Left Ventricular Assist Device (LVAD) on chosen haemodynamic parameters in the presence of ventilatory support. The software package used for this simulation reproduces, in stationary conditions, the heart and the circulatory system in terms of pressure and volume relationships. Different circulatory sections (left and right heart, systemic and pulmonary arterial circulation, systemic and pulmonary venous circulation) are described by lumped parameter models. Mechanical properties of each section are modelled by RLC elements. The model chosen for the representation of the Starling's law of the heart for each ventricle is based on the variable elastance model. The LVAD model is inserted between the left atrium and the aorta. The contractility of the heart and systemic arterial resistance were adjusted to model pathological states. Our simulation showed that positive thoracic pressure generated by mechanical ventilation of the lungs dramatically changes left atrial and pulmonary arterial pressures and should be considered when assessing LVAD effectiveness. Pathological changes of systemic arterial resistance may have a considerable effect on these parameters, especially when LVAD is applied simultaneously with mechanical ventilation. Cardiac output, systemic arterial and right atrial pressures are less affected by changes of thoracic pressure in cases of heart pathology.

Animals↗

A physical model of the human systemic arterial tree.

A physical model of the human arterial tree has been developed to be used in a computer controlled mock circulatory system (MCS). Its aim is to represent systemic arterial tree properties and extend the capacity of the MCS to intraortic balloon pump (IABP) testing. The main problem was to model the aorta simply and to accurately reproduce aortic impedance and related flow and pressure waveforms at different sections. The model is composed of eight segments; lumped parameter models are used for its peripheral loads. After the numerical simulation, the physical model was reproduced as a silicon rubber tapered tube. This rubber was chosen for its stability over time and the acceptable behaviour of its Young's modulus (Ey = 22.23 gf x mm(-2)) with different loads and in comparison with data from the literature (Ey approximately 20.4 gf x mm(-2)). The properties of each segment of the aorta were defined in terms of compliance, resistance and inertance as a function of length, radius and thickness. The variable thickness was obtained using positive and negative molds. Total static compliance of the aorta model is about 1.125 x 10(-3) g(-1) x cm4 x sec2 (1.5 cm3 x mmHg(-1)). Measurements were performed both on numerical and physical models (in open and closed loop configuration). Data reported show pressure and flow waveforms along with input impedance modulus and phase. The results are in good agreement with data from the literature.

Aorta↗

Computer simulation of hemodynamic parameter changes by mechanical ventilation and biventricular circulatory support.

When a Bi-Ventricular Assist Device (BVAD) is used in conjunction with mechanical ventilation (MV) of the lungs with positive intrathoracic pressure (Pt), the latter influences hemodynamics. The aim of our study was to assess the simultaneous influence of BVAD and MV on hemodynamics. We assumed ventricular pathological conditions as reduced elastances and increased rest volumes. Peripheral systemic arterial resistance was assumed to have different values. Data were obtained by computer simulation. Trends in main hemodynamic variables were compared with clinical data from literature. Simulation showed that systemic venous, pulmonary arterial and left atrial pressures are very sensitive to Pt (-2 to 5 mmHg).

Computer Simulation↗

The influence of simultaneous intra-aortic balloon pumping and mechanical ventilation on hemodynamic parameters--numerical simulation.

Intra-aortic balloon counterpulsation (IABC) is one of the methods to assist circulation. Its application is supposed to increase coronary blood flow (Qcor) and myocardial oxygen supply. Mechanical ventilation of the lungs causes some side effects that influence mainly hemodynamics, i.e. it decreases cardiac output (CO) and systemic aortic pressure (Pas) but increases systemic venous pressure (Pvs). The aim of this study was to assess the influence of IABC on hemodynamic parameters when mechanical ventilation of the lungs is used as well. We assumed pathological conditions of the heart as reduced left ventricle elastance (Ev = 0.77 mmHg/cm3) and increased left ventricle rest volume (V0 = 10 cm3). Also peripheral systemic arterial resistance (Ras) took three different values. CARDIOSIM, a computer simulator of the human cardiovascular system, was used to assess the changes of hemodynamic parameters [CO, Pas, Pvs, and pulmonary arterial pressure (Pap)] when IABC and mechanical ventilation of the lungs were applied simultaneously. Computer simulation showed that application of IABC increased such variables as CO (by approximately equal to 17%), maximum value of Pas (by approximately equal to 20%), while left atrial pressure (Pla) was diminished (by approximately equal to 30%). On the other hand, Pvs and Pap were not strongly affected by IABC, but they were dramatically dependent on intrathoracic pressure. This means that Pvs, Pap, and Pla should be carefully monitored during IABC and artificial ventilation.

Blood Pressure↗

A simple method for Emax trend evaluation: in vitro and in vivo results.

The aim of this study is the evaluation of end systolic ventricular elastance trend (as a measure of heart contractility) by hemodynamic variables available in intensive care units or during heart surgery: heart rate, cardiac output, left atrial, mean and diastolic arterial pressure. Its basic assumption is the description of ejection as the interaction between variable left ventricular and arterial compliances (reciprocal of the corresponding elastances) connected in parallel. As pressure is the same in each compliance at systole beginning and ending, ventricular elastance can be estimated by assuming that energy variation is the same on both compliances. The algorithm has been tested on a numerical simulator of the circulatory system and on six sheep at basal conditions and during drug infusion. Correlation function in numerical simulation, between true and computed ventricular elastance (range 0.45 divided by 5 mm Hg-cm(-3)), yields 0.985. In vivo comparison between computed ventricular elastance trend and ventricular dp/dt trend yields a correlation function ranging between 0.87 and 0.99. The result of the algorithm cannot be assumed to be Emax value. However, it can be considered a contractility index as it closely follows any change in dp/dt. It can be computed by simple calculations and needs no variables other than those usually measured in intensive care . It allows the extrapolation of useful information for evaluating the trend in heart contractility and for setting up a control strategy for mechanical or pharmacological assistance during heart recovery.

Algorithms↗

The influence of left ventricle assist device and ventilatory support on energy-related cardiovascular variables.

One of the main purposes in using Left Ventricle Assist Devices (LVAD) to assist recovery in patients with heart failure, is to reduce the external work (EW) of the left natural ventricle. The simultaneous presence of mechanical ventilatory support can affect the value of this variable. The aim of our computer simulation was to trace the influence of LVAD on EW, cardiac mechanical efficiency (CME) and pressure volume area (PVA) in the presence of ventilatory support. Pathological conditions of the heart were reproduced. Peripheral systemic arterial resistance (Ras) was also changed to model physiological and pathological states. The influence of mechanical ventilation was introduced by changing levels of mean thoracic pressure. In this way we were able to predict changes of EW, CME and PVA in both ventricles, during ventilatory (mechanical) and cardiovascular (LVAD) support. Our simulation showed that positive thoracic pressure seems to affect the energy-related cardiovascular variables and should be taken into account during the assessment of LVAD effectiveness. Pathological changes of systemic peripheral resistance have a considerable effect on EW, CME and PVA of left ventricle. On the other hand energy-related parameters of the right ventricle are not especially affected by changes in systemic peripheral resistance.

Computer Simulation↗

A computer controlled mock circulatory system for mono- and biventricular assist device testing.

The clinical use of heart assist devices for heart recovery, implies the problem of their in vitro testing and training to use. In a mock circulatory system developed to this aim, the main problem is reproducing interaction among the device, the ventricle and the circulatory network. This can be analysed by the position, on the p-v plane, of the working point defined by the intersection between end systolic ventricular (ESPVR) and arterial elastance lines. The system developed on this basis, connectable to mono- and biventricular parallel assist devices, was a closed loop model including systemic and pulmonary circulation. The arterial trees were reproduced by two windkessels with adjustable peripheral resistance, and the Starling's law of the heart by a variable elastance model. The software controls and monitors circulatory parameters and variables. Results showed the behavior of the system with preload or afterload changes. Further, the reproduction of physiological, pathological (obtained by modifying slope and volume intercept of the ESPVR line) and LVAD assisted circulatory conditions was shown. The assistance effect was underlined by the changes in the ventricular work cycle and in hemodynamics variables. The evaluation of the effect of device control strategy on the ventricle and its energetics (on p-v plane) were among the main characteristics of this system, which ought to be further improved to test devices such as the IABP, which requires a different aortic model.

Blood Pressure↗