PubMed Health⌕ Search

Biomedical subjects

C Disselhorst-Klug

Publications and source records attributed to C Disselhorst-Klug.

26 records · Page 2Linked to original sources

Estimation of the relationship between the noninvasively detected activity of single motor units and their characteristic pathological changes by modelling.

Neuromuscular disorders are often related to specific changes in the structure of single motor units (MUs). One approach for the detection of these changes is high-spatial-resolution EMG (HSR-EMG), which allows non-invasive recording of the activity of a single MU. Early investigations with patients suffering from various neuromuscular disorders have shown that there is a distinct difference between the HSR-EMG signals of healthy volunteers, patients with muscular disorders, and patients with neuronal disorders. In this study, the relationship between typical HSR-EMG patterns and characteristic pathological changes in the structure of the MUs is considered. Therefore, a muscle model has been developed which is adapted to the physiological properties of the m. abductor pollicis brevis. The effects of the loss of single muscle fibres (muscular disorders) and the loss of entire MUs (neuronal disorders) on the HSR-EMG pattern have been simulated. These simulations show the same HSR-EMG patterns as seen in patients and healthy volunteers. As a consequence, it can be assumed that the muscle model is an appropriate tool for the simulation of HSR-EMG signals. Furthermore, the simulation results support the hypothesis that the typical changes in the HSR-EMG pattern found in patients with neuromuscular disorders can be attributed to the characteristic changes in the structure of the MUs.

Action Potentials↗

Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases.

High Spatial Resolution electromyography (HSR-EMG), a new kind of noninvasive surface EMG based on a spatial filtering technique, was evaluated with respect to the diagnosis of neuromuscular diseases. HSR-EMG measurements were recorded from 61 healthy subjects and 72 patients with different neuromuscular diseases and analyzed quantitatively. The results indicate that a few parameters such as muscular conduction velocity, dwell time over root mean square, autocorrelation function, and chi-value are sufficient to recognize and classify specific signal alterations due to neuromuscular disorders. A diagnostic evaluation procedure calculating automatically the most probable diagnosis from the parameter results could assign the correct diagnosis to about 81% of the investigated patients and healthy subjects. Myopathic disorders were recognized with a sensitivity of 85% (specificity: 97%), neuropathic disorders with a sensitivity of 68% (specificity: 98%). We conclude that HSR-EMG shows a diagnostic validity similar to that described in literature for needle EMG. Moreover, the noninvasive technique provides the advantage of a simple and painless application.

Adolescent↗

Noninvasive approach to motor unit characterization: muscle structure, membrane dynamics and neuronal control.

The standard surface EMG reflects the compound activity of a high number of motor units which is finally due to its low spatial resolution in the detection of the potential distribution on the skin surface. Therefore, detailed information about the structural and functional characteristics of the muscle consisting of populations of motor units, like the functional anatomy, the excitation spread or the innervation pattern cannot be obtained from the standard surface EMG. A novel noninvasive EMG-procedure with high spatial resolution (HSR-EMG) allows in contrast to the standard surface EMG even the detection of the single motor unit activity. In this way, the noninvasive determination of detailed information about the muscle structure, the membrane dynamics and the neuronal control becomes possible. First applications of the HSR-EMG have shown that especially the noninvasively measured conduction velocity of the excitation is highly affected by physiological details, like the muscle temperature, the relative muscle fibre diameter or inhomogeneities in the connective tissue forming part of the volume conductor around the muscle. From the results of the HSR-EMG investigations it can be concluded that the information about the structural and functional characteristics of the muscle as well as a deeper insight in the active state of the muscle is essential for a correct interpretation of the standard surface EMG.

Animals↗

Principles of high-spatial-resolution surface EMG (HSR-EMG): single motor unit detection and application in the diagnosis of neuromuscular disorders.

The most detailed information about the structural and functional characteristics of the muscle can be gained from the single motor unit (MU) action potential. In addition, information about the activity of a single MU is essential for the diagnosis of neuromuscular disorders. Due to the low spatial resolution of conventional bipolar surface electromyography (EMG), the resulting signal is a superposition of a large number of simultaneous active MUs. The difficulty is in separating the activity of a single MU from simultaneous active adjacent MUs. In contrast to other non-invasive EMG procedures, the high-spatial-resolution-EMG (HSR-EMG), which is based on the use of a multi-electrode array in combination with a spatial filter procedure, allows the detection of single MU activity in a non-invasive way. It opens access to the excitation spread and enables the determination of the conduction velocity in single MUs, and the localization of the endplate region. In addition, HSR-EMG detects changes in the electrical activities of the MUs which are typical in neuromuscular disorders. Using HSR-EMG it was possible to identify 97% of all investigated volunteers and patients with muscular or neuronal disorders. Therefore, HSR-EMG is suitable as a tool for the non-invasive diagnosis of neuromuscular disorders.

Journal Article↗

Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters.

The conventional bipolar surface electromyography (EMG) technique detects, due to its low spatial resolution, the superimposed electromyographic activity of a large number of motor units (MU's). In superficial muscles the isolated action potentials of the most superficial MU's can be recorded noninvasively by means of surface electrodes, if the method of spatial filtering, in connection with electrode arrays, is used. Up to now, only filters with an anisotropic transfer function have been used. As the surface potential distribution generated by the excitation of the MU's contains spatial frequencies in the anisotropic range of those filters, it can be assumed that isotropic spatial filters detect the single MU activity more effectively. In the present study, different isotropic and anisotropic filters have been compared by means of theoretical field simulations and experiments in volunteers. A tripole model for an excited MU was used as the basis for simulating the spatial extension of the filter response for each of the investigated filters. The spatial extension is an indicative of the spatial resolution. For the experimental validation, the total number of single motor units was not directly investigated, but the signal-to-noise ratio (SNR) has been determined. Therefore, the potential distribution generated on the skin surface during maximum voluntary contraction has been simultaneous spatially filtered with each of the investigated filters. The simulations show that an isotropic spatial filtering procedure reduces the spatial extension of the filter response and improves the spatial resolution of the EMG-recording arrangement in comparison to anisotropic spatial filters up to 30%. In other words, the spatial selectivity of the arrangement is increased. This improvement in the filter performance is more pronounced for MU's located close to the skin surface than for MU's more distantly located. Additionally, this theoretical improvement in selectivity depends on the direction of the excitation spread relative to the filter alignment. However, the investigations also show that isotropic filters offer an advantage, compared to anisotropic filters, only when the investigated MU is located extremely close to the filter input. The results of the simulations can be confirmed by the experimental investigations. An improvement of 11% in the SNR, relative to anisotropic spatial filters, can be established when using an isotropic spatial filter. This experimental improvement in selectivity is less than the theoretical improvement because the experimentally investigated MU's have less portion in the anisotropic range of the filters than the simulated one at best.

Anisotropy↗

Clinical application of a noninvasive multi-electrode array EMG for the recording of single motor unit activity.

Using a recently developed noninvasive EMG recording technique with multi-electrode arrays we investigated the pattern and distribution of motor unit action potentials (MUAP) following maximal voluntary contraction of the musculus abductor pollicis brevis. An additional parameter, i.e. muscular conduction velocity (CV) in single motor units, was calculated from the multi-electrode array EMG recordings. From 63 healthy children of various age the normal EMG pattern and CV were derived and compared to the EMG of diagnosed patients known to suffer from Duchenne muscular dystrophy and from spinal muscular atrophy. In normal individuals the muscular CV in neonates was lowest at 1-2 m/s and gradually reached a plateau of 2.9-4 m/s from the age of 4 years onwards. The EMG in 31 children with Duchenne muscular dystrophy showed an abnormal pattern with low amplitude action potentials. In 30 out of 31 patients a significantly lower muscular CV was found. In 10 children with spinal muscular atrophy the EMG showed action potentials of abnormally large amplitude and a reduced recruitment of firing motor units. The muscular CV remained within the normal range. Compared to classical needle EMG the application of this new noninvasive EMG technique in children is painless and offers an easy-to-handle diagnostic tool to differentiate between neuromuscular diseases of denervating or of myopathic origin.

Adolescent↗

[Arm motion analysis: a new method and its clinical application].

AIM: An investigation into the objective criteria of shoulder mobility possesses special meaning for diagnostic documentation, the evaluation of therapy and the effects of rehabilitation in the treatment of diseases of the shoulder. In order to ascertain the criteria which characterise shoulder mobility, it is necessary to have a tool available that is objective, comparable and allows the complexity, variability and range of motion to be recorded. Motion analysis represents one such standard procedure used to measure joint movement. METHOD: Accordingly, a marker- based motion analysis of the wrist and elbow, a marker-based three-dimensional motion analysis system for the upper extremities was developed. We evaluated 10 healthy subjects without shoulder conditions and 8 patients with impingement syndrome (7 operative, 1 conservative therapy). RESULTS: The healthy subjects revealed a reproducible motion curve for the specific motion tested. The curves were defined as the normal standard and we used them for comparative purposes. In the treatment group, an improvement of the 3D range of motion could be documented for the affected shoulder following rehabilitation. CONCLUSION: It can be stated that this newly developed marker-based procedure for the three-dimensional motion analysis is suitable for recording complex unconstrained movements. This was found to be more relevant for the assessment of the ability of patients to manage the physical demands of daily living than traditional clinical tests. Furthermore, the information gained from motion analysis of the upper extremities will play a valuable role in the future for quality control during diagnosis and treatment, as well as for the design of shoulder rehabilitation programs.

Adult↗

Area-to-amplitude ratio of the terminal phase of the belly-tendon detected motor unit potentials could be used to recognize reinnervated motor units.

Besides the increased number of fibres, the reinnervated motor units (MUs) are characterised by an increased scattering the end-plates, greater desynchronization in the fibres' activation, greater dispersion in the diameters of the MU fibres and thus in propagation velocities along them. As a result, desynchronization in the moments, at which the excitation waves reach the fibres' ends, increases in reinnervated MUs. The possibility to recognize reinnervated MUs in short (hand) muscles on the basis of changes in duration of the terminal (second) phase of the belly-tendon detected motor unit potentials (MUPs) was examined by numerical experiments. A convolution model that took into account the finite fibre length, was used to calculate MUPs for distances typical of surface detection. It was shown that the ratio between the area of the terminal phase and its amplitude, as a measure of duration of the terminal phase, was sensitive to desynchronisation of the waves of excitation. The ratio was independent of the distance from the MU axis and of the volume conductor properties. Basing on the results obtained, we can conclude that the ratio reflects main functional compensations in reinnervated MUs and could be used for discrimination between reinnervated and normal MUs.

Electromyography↗