PubMed Health⌕ Search

Biomedical subjects

C Duvivier

Publications and source records attributed to C Duvivier.

At least 19 recordsLinked to original sources

[Medical care for HIV infection in France in 2005, the NADIS cohort study on 7416 patients].

OBJECTIVE: This study had for aim to evaluate the immuno-virological and therapeutic profile of a cohort of 7416 HIV-1 infected patients followed in six French hospital with the Nadis software. METHOD: This cross sectional and retrospective study was performed between June 1, 2004 and June 1, 2005. We analyzed the demographic (sex, age, HIV infection route), immunovirological, and therapeutic characteristics (last treatment prescribed) of the 7416 cohort patients. RESULTS: The mean age was 43 years, 29% were women and 29% HCV/HBV co infected. The viral load was 1.9 log(10)copies/ml (IQR: 1.5-3.3) and the CD4 cells count was 452/mm(3) [IQR: 306-630]. Among the 5,913 antiretroviral treated patients, VL was less than 200 copies/ml for 74.7% of patients and 50% of them had a CD4 cell count superior to 500/mm(3); the drug regimen was 2 or 3 nucleosides reverse transcriptase inhibitors (NRTI) combined with one protease inhibitor (88% Ritonavir boosted) in 42% of the patients, 26% of them were treated with 2 NRTI and 1 non-NRTI, and 14% with 3NRTI. Patients with undetectable VL were followed 5.1/year versus 7.2 for non- VL controlled patients (P<10(-3)). The heterosexual route predominated among the new 531 HIV-diagnosed patients among whom 25% had a median CD4 cell count of 242/ m(3). CONCLUSION: Close to 75% of antiretroviral treated patients had a VL<200 copies/ml but 15% kept a low CD4 cell count. The characteristics of recently diagnosed HIV positive patients stresses the need for more information on prevention and an early diagnosis.

Adult↗

[Early detection of hepatitis C virus infection using a new combined antigen-antibody detection assay: potential use in HIV co-infected individuals].

BACKGROUND: The aim of this study was to determine the clinical benefit of a new combined antigen-antibody immunoenzymatic assay (Monolisa HCV Ag-Ab Ultra, Biorad) in the setting of acute HCV infection in HIV infected patients. PATIENTS AND METHODS: The performance of this assay was first evaluated in 160 HIV positive samples from uninfected and chronically HCV infected patients. To assess the performance of the Ag-Ab assay in the context of acute hepatitis C, 94 stored frozen serums from 20 recently diagnosed cases were retrospectively tested for HCV-RNA and presence of anti-HCV antibodies, in parallel with the new assay. RESULTS: In HIV infected patients, the sensitivity and specificity of the Ultra assay was 100% with a strong discrimination between positive and negative samples. In HCV acutely infected patients, the Ag-Ab assay significantly reduced the seronegative period, allowing an earlier diagnosis compared to a 3rd generation ELISA in 65% of the cases. The combined assay became positive on the same bleed as the first HCV-RNA detection for 13 patients out of 20. Nevertheless, in one case, characterized by an absence of seroconversion over one year but a continuous viral replication above 1 million IU/ml, the combined assay did not improve HCV infection diagnosis. CONCLUSION: Use of this new assay as a first line screening would significantly reduce the long seronegative window period seen in HCV infection allowing earlier HCV diagnosis and rapid clinical management. However, in case of clinical acute hepatitis C, sensitive HCV-RNA detection should remain the gold standard.

Antigen-Antibody Complex↗

Early detection of hepatitis C virus infection by use of a new combined antigen-antibody detection assay: potential use for high-risk individuals.

The performance of a new combined antigen-antibody assay (Monolisa HCV Ag-Ab Ultra; Bio-Rad Laboratories) was evaluated in the context of acute hepatitis C in human immunodeficiency virus-infected patients. The combined assay became positive as early as the first PCR and earlier than a third-generation enzyme-linked immunosorbent assay in 65% of the cases. Reduction of the long period of HCV seronegativity should improve the diagnosis of hepatitis C infection, especially in high-risk populations.

Adult↗

Persistent low viral load on antiretroviral therapy is associated with T cell-mediated control of HIV replication.

BACKGROUND: It is unclear how stable low-level viral replication and CD4 cell numbers can be maintained under highly active antiretroviral therapy (HAART). This study was designed to analyse whether HIV-specific responses in stable partially controlled patients during antiretroviral therapy (ART) differ from those observed in complete HAART failure and whether they contribute to the control of viral load (VL). METHODS: Three groups of patients were selected according to plasma HIV RNA levels during 18 months of ART: persistently low VL (LoVL; HIV RNA <10,000 copies/ml; n = 28), undetectable VL (UnVL; HIV RNA <200 copies/ml; n = 29) and high VL (HiVL; HIV RNA >10,000 copies/ml; n = 14). T-cell responses were studied using lymphoproliferative and interferon (IFN)-gamma-ELISpot assays against HIV-p24, -gp160, recall antigens, and 15 pools of HIV-(Gag + RT) peptides. RESULTS: Frequencies of IFN-gamma-producing CD4 T cells against HIV-p24 were higher in LoVL than in UnVL or HiVL groups [median, 131, 47 and 23 spot-forming cells (SFC)/1 x 10 peripheral blood mononuclear cells (PBMC), respectively; P = 0.012 and P = 0.047]. Lymphoproliferative responses to HIV-p24 and recall antigens were similar in LoVL and UnVL groups but lower in HiVL (P = 0.004). Frequencies of HIV-specific CD8 T cells were higher in LoVL than in UnVL (1340 versus 410 SFC/1 x 10 PBMC; P = 0.001). They correlated negatively with VL in the LoVL and HiVL (r, -0.393, P = 0.039 and r, -0.643, P = 0.024, respectively) and positively correlated with anti-HIV CD4 cell frequencies in the LoVL group only (r, 0.420; P = 0.026). CONCLUSION: Persistently low viral replication (<10,000 copies/ml) during ART stimulates high frequencies of HIV-specific CD4 and CD8 T cells compared to full virus suppression or complete ART failure. The association of high anti-HIV activity with large numbers of HIV-specific CD8 T cells contribute to the control of viral replication.

Adult↗

Acute hepatitis C in HIV-infected men who have sex with men.

BACKGROUND: Hepatitis C virus (HCV) is usually transmitted via the parenteral route, but there are widely discrepant findings on its possible sexual transmission. Thus there are no recommendations concerning protected sex for couples in which only one partner is HCV-infected. Whether HIV or other sexually transmitted diseases could favour HCV transmission remains unclear, but recent data suggesting an increasing incidence of acute HCV in HIV-infected men underline the major public health implications of this issue. CASE REPORTS: Between June 2002 and July 2003, five HIV-infected homosexually active men presented with primary (n=4) and secondary (n=1) syphilis and concomitant abnormal liver function tests revealing acute asymptomatic HCV seroconversion. Other causes of acute viral hepatitis were inquired into and excluded. Highly at-risk sexual behaviour, including unprotected anal intercourse and unsafe oral sex, with concomitant syphilis, was found to be the only identifiable important risk factor for transmission of HCV. CONCLUSIONS: Sexual transmission may be fuelling a significant increase in HCV seroconversions among HIV-infected men who have highly risky sexual behaviours. Given the recent data suggesting the spread of sexually transmitted infections among HIV-infected gay men, specific recommendations concerning safe sex are urgently needed.

Acute Disease↗

[NADIS 2000, development of an electronic medical record for patients infected by HIV, HBV and HCV].

OBJECTIVE: to develop an electronic medical record for patients living with HIV, HBV or HCV in order to improve their management, facilitate communication between all the caregivers, and to create a useful medical database for research and assessments. This project (NADIS 2000) involved 6 centres of Infectious Diseases in France in partnership with Fédialis Médica (subsidiary of the GSK group in France). METHODS: A specifications sheets was drawn-up by a piloting Committee regrouping the various correspondents in each centre and a computer expert representing Fédialis Médica. A Scientific and Development committee regrouped the heads of departments of each centre and the representatives from Fédialis Médica and GSK and was charged with defining the general concept of the project and guaranteeing the scientific and clinical aspects. RESULTS: NADIS 2000 version 1.0 was activated in the departments of infectious diseases in Nice and Toulouse in November 2000 and in others Units at the end of 2001. NADIS 2000 permitted real-time use by the physicians in the Outpatients and Day-care Units and was easily handled by all the practitioners. Its use was eased by the principles clearly defined before its application (department project, progressive but exhaustive use), an intuitive interface simulating a consultation, and functions proposing direct benefits for the physicians (graphical visualization of the biological variables, printing of prescriptions and letters). CONCLUSION: The activation and input methods of NADIS 2000 are user friendly and the physicians find it rapidly easy to use. New functional aspects are being developed as well as its use in other hospital departments.

Computer Communication Networks↗

Re-occurrence of HIV-1 drug mutations after treatment re-initiation following interruption in patients with multiple treatment failure.

Antiretroviral treatment interruption in 20 extensively pre-treated HIV-1 patients with treatment failure led to genotype viral reversion of at least one class of drug-mutation resistance in half of the patients. The only predictive factor of reversion was found to be the duration of interruption. The outgrowth of residual wild-type virus seems not to be a true genetic reversion because drug mutations are detected rapidly at salvage therapy re-initiation.

Antiretroviral Therapy, Highly Active↗

Volume dependence of respiratory system resistance during artificial ventilation in rabbits.

The volume dependence of respiratory resistance (Rrs), usually observed during normal breathing, is expected to be accentuated during expiratory flow limitation (EFL). In order to quantify this dependence we studied the pressure, flow, and volume data obtained from eight New Zealand rabbits, artificially ventilated at different levels of applied expiratory pressure (0-10 hPa), before and during histamine i. v. infusion. EFL was provoked by lowering the expiratory pressure and was detected by the application of an additional negative expiratory pressure and by forced oscillations. The analysis of respiratory system mechanics was performed by multiple regression, using the classical linear first-order model and also a nonlinear model, accounting for volume dependence of Rrs. Both models satisfactorily fitted the data in the absence of EFL. The nonlinear model proved to be more appropriate in the presence of EFL. The coefficient expressing the volume dependence of Rrs (Rvd) was significantly more negative during EFL. Rvd values were highly correlated with the fraction of the tidal volume left to be expired at the onset of EFL. A threshold Rvd value of -1,000 (hPa x s x l(-2)) detected EFL with high sensitivity and specificity. We conclude that a strongly negative volume dependence of Rrs is a reliable and noninvasive index of EFL during artificial ventilation.

Animals↗

Nosocomial Serratia marcescens infections associated with extrinsic contamination of a liquid nonmedicated soap.

OBJECTIVE: To determine the role of nonmedicated soap as a source of Serratia marcescens nosocomial infections (NIs) in hospital units with endemic S marcescens NI and to examine the mechanisms of soap colonization. SETTING: University-affiliated tertiary-care hospitals. METHODS: A prospective case-control study and an environmental investigation were performed to assess the relationship between S marcescens NIs in hospital units and S marcescens-contaminated soap. Soap-bottle use and handwashing practices were reviewed. Cultures of healthcare workers' (HCWs) hands were obtained before and after hand washing with soap. RESULTS: 5 of 7 hospital units with S marcescens NIs had soap bottles contaminated with S marcescens, compared to 1 of 14 other units (P=.006). After hand washing with an S marcescens-contaminated soap pump, HCWs' hands were 54 times more likely to be contaminated with S marcescens (P<.001). CONCLUSIONS: Extrinsic contamination of a non-medicated liquid soap by S marcescens resulted in handborne transmission of S marcescens NIs by HCWs in our setting. This finding led to the application of strict guidelines for nonmedicated soap use and to the reinforcement of alcoholic hand disinfection.

Case-Control Studies↗

A simplified method for monitoring respiratory impedance during continuous positive airway pressure.

The forced oscillation technique is useful in detecting changes in upper airway obstruction in patients with sleep apnoea undergoing continuous positive airway pressure (CPAP) ventilation. The aim of this study was to implement and evaluate a method for estimating respiratory impedance (Zrs) from the pressure and flow recorded at the inlet of the CPAP tubing. The method is based on correcting impedance measured at the inlet of the CPAP tubing (Zi) for the effect of the tubing and the exhalation port. The method was evaluated in mechanical analogues and in a healthy subject. Sinusoidal oscillation of 5, 10 and 20 Hz were superimposed on CPAP (5-15 cmH2O). At 5 Hz, the changes in airflow obstruction were substantially underestimated by Zi. Furthermore, Zi exhibited a negative dependence on Zrs at 20 Hz. The assessment of Zrs was greatly improved after correcting Zi for the effects of the CPAP tubing and the exhalation port. Zrs was well estimated at low frequencies, reaching very high values during total occlusion (>60 cmH2O x s x L(-1) at 5-10 Hz). These results indicate that changes in airflow obstruction can be detected using the forced oscillation technique from pressure and flow recorded on the continuous positive airway pressure device. This facilitates the clinical application of the forced oscillation technique for monitoring upper airway patency during sleep.

Airway Resistance↗

Removal of thermal artifact in alveolar pressure measurement during forced oscillation.

Thoracic gas volume (TGV) may be measured and total respiratory impedance (Zrs) may be partitioned into its airway and tissue (Zti) components by combining forced oscillations and plethysmographic measurements of alveolar gas compression (Vpl) (Peslin, Duvivier, 1998, J. Appl. Physiol. 84, 553-561 and 862-867). The method requires that the thermal component of Vpl (Vpl,th) be eliminated by conditioning inspired gas to BTPS. We have evaluated a technically simpler method where Vpl,th is corrected using a thermal gain (G) and a thermal time constant (theta). Zrs and the relationship between Vpl and flow (Hpl) were measured in 15 healthy subjects at frequencies from 4 to 29 Hz. G was obtained from the breathing component of Vpl in phase with volume. Zti and TGV (TGVos) were computed from Zrs and from Hpl after the latter was corrected using G and different values of theta. With theta = 27.5 ms both the difference between TGVos and standard plethysmographic TGV, and the difference between Zti spectra obtained with and without gas conditioning were minimal. We conclude that the simpler method is adequate for both purposes.

Adult↗

Partitioning of respiratory mechanical impedance by absolute and differential body plethysmography.

We have recently demonstrated the feasibility of partitioning total respiratory impedance (Zrs) into its airway (Zaw) and tissular (Zti) components by measuring alveolar gas compression (Vpl) plethysmographically during pressure oscillations at the airway opening (Peslin et al.). The aim of this study was to comparatively evaluate an alternative approach: the measurement of Zrs and of the transfer function (FTF) between airway flow and body surface flow obtained by absolute body plethysmography. The two approaches are theoretically equivalent, provided thermal and other artifacts are properly eliminated. Zrs and Vpl (method 1) and Zrs and FTF (method 2) were measured in 11 healthy subjects from 4 to 29 Hz, using a pressure-type and a flow-type plethysmograph, respectively. Inspired gas was conditioned to body temperature and pressure, saturated with water vapor in both instances to minimize thermal factors. Zaw and Zti spectra computed from both sets of data were quite similar in shape. Neither airway resistance nor tissue compliance differed significantly; tissue resistance, however, was about 14% lower with method 1, which may be due to imperfect gas conditioning. The reproducibility of the data was similar with the two approaches. We conclude that absolute body plethysmography is as reliable as differential body plethysmography to partition Zrs.

Adult↗

Reliability of thoracic gas volume derived from mechanical impedance at different levels of the vital capacity.

BACKGROUND: Thoracic gas volume (TGV) may be estimated during spontaneous breathing by measuring simultaneously respiratory impedance (Zrs) and alveolar gas compression (Vpl) at several oscillation frequencies [Peslin and Duvivier: J Appl Physiol 1998;84:862-867]. OBJECTIVE: The aim of the study was to test the validity of that approach at different levels of the vital capacity (VC). METHODS: We measured Zrs and Vpl at frequencies ranging from 6 to 29 Hz in 10 healthy subjects rebreathing BTPS gas in a constant volume body plethysmograph. In a first series, the subjects were asked to breathe voluntarily at different levels of the VC and oscillation TGV (TGVos) was compared to standard plethysmographic TGV (TGVst) assessed immediately after TGVos measurements. In a second series, the subjects were asked to change stepwise their lung volume in the middle of the forced oscillation recording, and the changes in TGVos (DeltaTGVos) were compared to the changes in lung volume (DeltaV) computed from the integrated flow signal. RESULTS: In most subjects TGVos and TGVst were highly correlated and the slopes of the relationships did not differ significantly from unity. DeltaTGVos and DeltaV were also highly correlated both in individuals and in the group (r = 0.97), and their signless differences averaged 0.23 +/- 0.20 liter. CONCLUSION: We conclude that forced oscillation estimates of TGV are reliable in healthy subjects over a large part of the VC.

Adult↗

Partitioning of airway and respiratory tissue mechanical impedances by body plethysmography.

We have tested the feasibility of separating the airway (Zaw) and tissue (Zti) components of total respiratory input impedance (Zrs,in) in healthy subjects by measuring alveolar gas compression by body plethysmography (Vpl) during pressure oscillations at the airway opening. The forced oscillation set up was placed inside a body plethysmograph, and the subjects rebreathed BTPS gas. Zrs,in and the relationship between Vpl and airway flow (Hpl) were measured from 4 to 29 Hz. Zaw and Zti were computed from Zrs,in and Hpl by using the monoalveolar T-network model and alveolar gas compliance derived from thoracic gas volume. The data were in good agreement with previous observations: airways and tissue resistance exhibited some positive and negative frequency dependences, respectively; airway reactance was consistent with an inertance of 0.015 +/- 0.003 hPa.s2.l-1 and tissue reactance with an elastance of 36 +/- 8 hPa/I. The changes seen with varying lung volume, during elastic loading of the chest and during bronchoconstriction, were mostly in agreement with the expected effects. The data, as well as computer simulation, suggest that the partitioning is unaffected by mechanical inhomogeneity and only moderately affected by airway wall shunting.

Adult↗

Evaluation of a forced oscillation method to measure thoracic gas volume.

The purpose of this study was to test a plethysmographic method of measuring thoracic gas volume (TGV) that, contrary to the usual panting method, would not require any active cooperation from the subject. It is based on the assumption that the out-of-phase component of airway impedance varies linearly with frequency. By using that assumption, TGV may be computed by combining measurements of total respiratory impedance (Zrs) and of the relationship between the plethysmographic signal (Vpl) and airway flow (V) during forced oscillations at several frequencies. Zrs and Vpl/V were measured at 10 noninteger multiple frequencies ranging from 4 to 29 Hz in 15 subjects breathing gas in nearly BTPS conditions. Forced oscillation measurements were immediately followed by determination of TGV by the standard method. The data were analyzed on different frequency ranges, and the best agreement was seen in the 6- to 29-Hz range. Within that range, forced oscillation TGV and standard TGV differed little (3.92 +/- 0.66 vs. 3.83 +/- 0.73 liters, n = 77, P < 0.05) and were strongly correlated (r = 0.875); the differences were not correlated to the mean of the two estimates, and their SD was 0.35 liter. In seven subjects the differences were significantly different from zero, which may, in part, be due to imperfect gas conditioning. We conclude that the method is not highly accurate but could prove useful when, for lack of sufficient cooperation, the panting method cannot be used. The results of computer simulation, however, suggest that the method would be unreliable in the presence of severe airway inhomogeneity or peripheral airway obstruction.

Airway Resistance↗

AIDS-related primary pulmonary lymphoma.

We describe 12 cases of AIDS-related primary pulmonary lymphoma occurring between 1986 and 1996 in a large French cohort of HIV-infected patients. Diagnostic criteria were: (1) histologically proven lymphomatous pulmonary involvement; (2) absence of mediastinal and/or hilar adenopathy on chest radiography; (3) absence of extrathoracic lymphoma extension. All patients were severely immunodeficient at the time of diagnosis. All but one patient presented with B and/or nonspecific respiratory symptoms. Chest radiography showed one or more marginated nodule(s) or large mass. CT scan showed a cavitary lesion in five patients. No lymph node enlargement or specific pleural effusion was detected. Transthoracic needle biopsies were performed in 10 patients and avoided open-lung biopsy for the diagnosis of lymphoma in five patients. All but one of the primary pulmonary lymphoma were high-grade B-cell non-Hodgkin's lymphomas. Using antilatent membrane protein-1 antibodies and an Epstein-Barr-Virus-encoded RNA transcript-specific probe, latent EBV infection of tumor cells was demonstrated in every case. All but one of the patients received chemotherapy. The median survival time was 4 mo, and no patient was still alive at the cut-off date for this analysis. Progessive pulmonary lymphoma was the main cause of death, but infections were also frequent.

AIDS-Related Opportunistic Infections↗

Variations in airways impedance during respiratory cycle derived from combined measurements of input and transfer impedances.

Simultaneous measurement of input (Zin) and transfer impedances (Ztr) allows separation of airway and tissue properties at a single frequency, without making assumptions concerning the structure of the two compartments. This approach offers the possibility of studying the variation in airway impedance (Zaw) during the respiratory cycle. Zin and Ztr were measured at frequencies of 10, 20, 30 and 40 Hz in eight healthy subjects to study the variations in Zaw according to a modification of the Rohrer's equation: X=K1+K2(V'ao)-K3V, where V is volume and V'ao the flow at the airway opening. The results showed that Zaw could be modelled as a simple resistance-inertance pathway. Variations in airway resistance (Raw) with flow were greater during expiration than during inspiration with K2 values varying from 0.76-0.90 hPa x s2 x L(-2) during inspiration and 0.84-1.47 hPa x s2 x L(-2) during expiration, independently of frequency. Raw was negative volume dependent; it decreased more with increasing volume during inspiration than during expiration. Airways inertance calculated from the imaginary part of Zaw also underwent systematic variations during the respiratory cycle, but, in contrast to Raw, flow dependence was negative during both phases. In conclusion, the approach used in this study allows flow and volume dependencies of airways mechanical properties to be studied and can also provide indices of airway patency independently of flow, which is of great potential interest for studying variations in airway resistance during bronchomotor tests.

Adult↗