PubMed HealthSearch

Biomedical subjects

C E Neumeister

Publications and source records attributed to C E Neumeister.

2 recordsLinked to original sources

Development and use of a sampling and analytical method for azodicarbonamide.

Azodicarbonamide is a medium temperature blowing agent used in the production of foamed polymers. Because of worker concern over health effects associated with its use, researchers from the National Institute for Occupational Safety and Health (NIOSH) conducted two health hazard evaluations. This paper describes the health concerns, the sampling and analytical method used, the environments sampled and the results of these surveys. Environmental samples were collected on Teflon filters for total dust and airborne concentration of azodicarbonamide. Analysis was accomplished by high performance liquid chromatography with identification and quantitation by UV detector response ratioing. Use of this method provided the sensitivity and specificity to analyze airborne azodicarbonamide concentrations and allowed evaluation of a workplace environment for a respiratory health hazard.

Air Pollutants, Occupational

Environmental sampling and analysis for zeranol.

Due to concern over health effects associated with the use of zeranol, a sampling and analytical method to monitor zeranol in the work environment was developed. The collection strategy included air samples on FHLP filters, area samples on gauze pads, hand/dermal samples on gauze pads and bulk samples. The sampling method evaluation included choice of media, flow rate and duration for air samples, sample preparation, extraction efficiencies and sample stability. Analysis of the samples was accomplished by high performance liquid chromatography with identification and quantification by UV and fluorescence detection. The analytical method evaluation included separation of possible interfering compounds, calibration curves, limits of detection (LOD), limits of quantitation (LOQ), precision and accuracy. The tested analytical range was 0.01 to 150 micrograms/mL with a LOD of 0.007 microgram/mL and a LOQ of 0.02 microgram/mL using UV detection. For the fluorescence detector, the LOD was 0.05 microgram/mL and the LOQ was 0.15 microgram/mL. Peak confirmation was achieved by retention time and comparing the two detector responses. Use of this method provided the sensitivity and specificity to analyze environmental samples for zeranol in the workplace environment.

Air Pollutants, Occupational