PubMed Health⌕ Search

Biomedical subjects

C Eggeling

Publications and source records attributed to C Eggeling.

7 recordsLinked to original sources

Fluorescence fluctuation spectroscopy in reduced detection volumes.

Fluorescence fluctuation spectroscopy is a versatile technique applied to in vitro and in vivo investigations of biochemical processes such as interactions, mobilities or densities with high specifity and sensitivity. The prerequisite of this dynamical fluorescence technique is to have, at a time, only few fluorescent molecules in the detection volume in order to generate significant fluorescence fluctuations. For usual confocal fluorescence microscopy this amounts to a useful concentration in the nanomolar range. The concentration of many biomolecules in living cell or on cell membranes is, however, often quite high, usually in the micro- to the millimolar range. To allow fluctuation spectroscopy and track intracellular interaction or localization of single fluorescently labeled biomolecules in such crowded environments, development of detection volumes with nanoscale resolution is necessary. As diffraction prevents this in the case of light microscopy, new (non-invasive) optical concepts have been developed. In this mini-review article we present recent advancements, implemented to decrease the detection volume below that of normal fluorescence microscopy. Especially, their combination with fluorescence fluctuation spectroscopy is emphasized.

Biotechnology↗

Comparison of different fluorescence fluctuation methods for their use in FRET assays: monitoring a protease reaction.

We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Förster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence Intensity Distribution Analysis (FIDA). The presented fluorescence data are compared to High-Pressure Liquid Chromatography (HPLC) data obtained from the same assay. The HPLC analysis discloses general disadvantages of the FRET approach, such as incomplete labeling and the need for aliquots. However, the simultaneous use of two photon detectors monitoring the fluorescence signal of both labels significantly improves the analysis. In particular, the two global analysis tools Two-Dimensional Fluorescence Intensity Distribution Analysis (2D-FIDA) and Two-Color Global Fluorescence Correlation Spectroscopy (2CG-FCS) highlight the potential of a combination of FFS and FRET. While conventional FIDA and FCS auto- or cross-correlation analysis leaves the user with drawbacks inherent in two-color and FRET applications, these effects are overcome by the global analysis on the molecular level. Furthermore, it is advantageous to analyze the unnormalized as opposed to the normalized correlation data when combining any fluorescence correlation method with FRET, since the analysis of the unnormalized data introduces more accuracy and is less sensitive to the experimental drawbacks.

Algorithms↗

New fluorescence techniques for high-throughput drug discovery.

The rapid increase of compound libraries as well as new targets emerging from the Human Genome Project require constant progress in pharmaceutical research. An important tool is High-Throughput Screening (HTS), which has evolved as an indispensable instrument in the pre-clinical target-to-IND (Investigational New Drug) discovery process. HTS requires machinery, which is able to test more than 100,000 potential drug candidates per day with respect to a specific biological activity. This calls for certain experimental demands especially with respect to sensitivity, speed, and statistical accuracy, which are fulfilled by using fluorescence technology instrumentation. In particular the recently developed family of fluorescence techniques, FIDA (Fluorescence Intensity Distribution Analysis), which is based on confocal single-molecule detection, has opened up a new field of HTS applications. This report describes the application of these new techniques as well as of common fluorescence techniques--such as confocal fluorescence lifetime and anisotropy--to HTS. It gives experimental examples and presents advantages and disadvantages of each method. In addition the most common artifacts (auto-fluorescence or quenching by the drug candidates) emerging from the fluorescence detection techniques are highlighted and correction methods for confocal fluorescence read-outs are presented, which are able to circumvent this deficiency.

Algorithms↗

Data registration and selective single-molecule analysis using multi-parameter fluorescence detection.

A general strategy to identify and quantify sample molecules in dilute solution employing a new spectroscopic method for data registration and specific burst analysis denoted as multi-parameter fluorescence detection (MFD) was recently developed. While keeping the experimental advantage of monitoring single molecules diffusing through the microscopic open volume element of a confocal epi-illuminated set-up as in experiments of fluorescence correlation spectroscopy, MFD uses pulsed excitation and time-correlated single-photon counting to simultaneously monitor the evolution of the four-dimensional fluorescence information (intensity, F; lifetime, tau; anisotropy, r; and spectral range, lambda(r)) in real time and allows for exclusion of extraneous events for subsequent analysis. In this review, the versatility of this technique in confocal fluorescence spectroscopy will be presented by identifying freely diffusing single dyes via their characteristic fluorescence properties in homogenous assays, resulting in significantly reduced misclassification probabilities. Major improvements in background suppression are demonstrated by time-gated autocorrelation analysis of fluorescence intensity traces extracted from MFD data. Finally, applications of MFD to real-time conformational dynamics studies of fluorescence labeled oligonucleotides will be presented.

Fluorescent Dyes↗

Conformational changes of the H+-ATPase from Escherichia coli upon nucleotide binding detected by single molecule fluorescence.

Using a confocal fluorescence microscope with an avalanche photodiode as detector, we studied the fluorescence of the tetramethylrhodamine labeled F1 part of the H+-ATPase from Escherichia coli, EF1, carrying the gammaT106-C mutation [Aggeler, J.A. and Capaldi, R.A. (1992) J. Biol. Chem. 267, 21355-21359] in aqueous solution upon excitation with a mode-locked argon ion laser at 528 nm. The diffusion of the labeled EF1 through the confocal volume gives rise to photon bursts, which were analyzed with fluorescence correlation spectroscopy, resulting in a diffusion coefficient of 3.3 x 10(-7) cm2 s(-1). In the presence of nucleotides the diffusion coefficient increases by about 15%. This effect indicates a change of the shape and/or the volume of the enzyme upon binding of nucleotides, i.e. fluorescence correlation spectroscopy with single EF1 molecules allows the detection of conformational changes.

Amino Acid Substitution↗

Monitoring conformational dynamics of a single molecule by selective fluorescence spectroscopy.

A recently developed, real-time spectroscopic technique, burst-integrated fluorescence lifetime (BIFL), is shown to be well suited for monitoring the individual molecular conformational dynamics of a single molecule diffusing through the microscopic, open measurement volume (approximately 10 fl) of a confocal epi-illuminated set-up. In a highly diluted aqueous solution of 20-mer oligonucleotide strand of DNA duplex labeled with the environment-sensitive fluorescent dye tetramethylrhodamine (TMR), fluorescence bursts indicating traces of individual molecules are registered and further subjected to selective burst analysis. The two-dimensional BIFL data allow the identification and detection of different temporally resolved conformational states. A complementary autocorrelation analysis was performed on the time-dependent fluctuations in fluorescence lifetime and intensity. The consistent results strongly support the hypothesized three-state model of the conformational dynamics of the TMR-DNA duplex with a polar, a nonpolar, and a quenching environment of TMR.

Kinetics↗

The psychosocial implications of live-related kidney donation.

The aim of the study was to explore the donor's experience of the live related transplantation process whilst seeking to identify the external and internal resources and ethical considerations which were reflected in the decision-making process. The outcome would indicate that altruism and a sense of moral obligation were the prime motivational influences with the spontaneity of decision-making casting doubt on the ability to give informed consent. These findings are also discussed in relation to implications for professional practice and would suggest that potential donors benefit from having access to a counsellor during the donor-search and throughout the transplant work up programme.

Adult↗