Ultrasound velocity of trabecular cubes reflects mainly bone density and elasticity.

Studies have indicated that quantitative ultrasound (QUS) variables may be influenced by the mechanical properties of bone which in turn are determined by bone's material and structural properties. However, from these studies it is unclear what role density, elasticity, and structure play in determining velocity. Eighteen defatted, 12-mm cubic trabecular bone specimens were cut from cadaveric specimens. Amplitude-dependent speed of sound (SOS) using a single point QUS system was assessed in three orthogonal axes. Magnetic resonance images were obtained, from which measures of apparent trabeuclar structure were derived. The specimens were nondestructively tested in compression along three orthogonal axes defined by the sides of the cubes. The elastic modulus (in the three directions) and the strength (in one direction) were determined. Trabecular BMD was measured by quantitative computed tomography. SOS varied significantly with direction of measurement, with the highest value in the axial direction (axial:1715 m/s, sagittal: 1662 m/second, and coronal: 1676 m/s). SOS of each of the three axes was generally associated with the various mechanical (r = 0.30-0.87), density (r = 0.81-0.93), and bone structural variables (0.3-0.8). However, after adjusting the SOS correlations by density, only the correlation with elasticity remained significant in the coronal direction. BMD alone explained 88-93% of variance in SOS whereas in the multivariate model, BMD plus elasticity and/or anisotropic variables explained 96-98% of the variance in SOS. Variability of SOS is explained mostly by density and to a small extent by elasticity or anisotropy. Since only 2-6% of the variance of the QUS measurement is not explained by density and elasticity, one could conclude that the remaining variance reflects other properties of bone or perhaps simply measurement error. Evidence that these other properties may be structure related is only found in the anisotropy of QUS parameter.

Adult↗

Radiation exposure in bone mineral density assessment.

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue which leads to diminished biomechanical competence of the skeleton and low-trauma or atraumatic fractures. Due to increased awareness of the impact of osteoporosis on the elderly population, the use of bone densitometric techniques is becoming more widespread. Considerable progress has been made in the development of non-invasive methods for the assessment of the skeleton. While DXA and QCT are commonly used techniques, the popularity of other approaches such as RA, SXA and QUS is gaining grounds. QCT has an advantage over the other techniques in its ability to measure the true volumetric density of trabecular or cortical bone. We therefore present an overview of these current techniques for bone mineral density (BMD) measurements. In the second section we discuss the radiation doses incurred in BMD measurements by patients and methods for reducing patient and staff radiation exposure are given. Studies of radiation dose to patient from DXA confirms that patient dose is small (0.08-4.6 muSv) compared to that given by many other investigations involving ionizing radiation. Fan beam technology with increased resolution has resulted in increase patient dose radiation dose (6.7-31 muSv) but this is still relatively small. Carrying vertebral morphometry using DXA also incurs less radiation dose (< 60 muSv) than standard lateral radiographs QCT has radiation dose (25-360 muSv) comparable to simple radiological examination such as chest X-ray but lower than imaging CT. Radiation dose from other techniques such as RA and SXA are in the same order of magnitude as pencil beam DXA. For pencil beam DXA and SXA systems the time average dose to staff from scatter is very low even with the operator sitting as close as 1 m from the patient during measurement. However the scatter dose from fan beam DXA systems is considerable higher and approaches limits set by regulator bodies for occupational exposure.

Absorptiometry, Photon↗

An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen.

To measure the speed of sound (SOS), most quantitative ultrasound (QUS) devices use the transmission mode, whereby two transducers are placed on opposite sides of the sample. This mode is limited to a few specific skeletal sites because of the varying configuration of bone geometry and varying amounts of overlying soft tissue at most other sites. The aim of this study was to address the dependence of SOS measured along the sample on the thickness and composition of the bone sample. Bovine samples from mid-femur and trochanter, and perspex phantoms were used. We prepared the perspex samples in the shapes of blocks and cylinders to investigate the effect of wall thickness on SOS. The thickness of the blocks was decreased in decrements of 1 mm; a 22 mm diameter hole was drilled through the cylindrical samples and the hole size was gradually increased. The second configuration was also used with the bovine samples. For each experimental set-up five SOS measurements were acquired, with the probe aligned along the sample and a mean value computed. All measurements were taken with castor oil as the coupling agent, and in the cylindrical cases, the oil was used to fill the tube. The measurement precision determined as the root mean square coefficient of variation (RMSCV) was determined to be 0.14% and 0.65% for perspex and bovine samples respectively. The measured SOS on the perspex phantom (2760+/-4 m/s) was within the published values for bulk velocity. It was observed that for both perspex and bovine samples the SOS was independent of sample wall thickness greater than the wavelength (2.2 mm, 2.7 mm and 3.5 mm for perspex, trochanter and mid-femur respectively). The SOS decreased with sample wall thickness smaller than the wavelength in concordance with theoretical predictions. The SOS values obtained for bovine samples reflected either totally cortical (mid-femur) or a composite of cortical and cancellous bone (trochanter).

Animals↗

Acoustic and ultrasonic tissue characterization--assessment of osteoporosis.

Osteoporosis, often termed the 'silent epidemic', has been defined as 'a decrease in bone mass and architectural deterioration of bone tissue, leading to enhanced bone fragility and consequent increase in fracture risk'. In the United Kingdom alone, the annual health costs are in excess of 750 million Pounds, with 60,000 patients suffering a hip fracture each year. A quarter of these will die within 12 months of their fracture, half of the remainder will never regain independent living. The established procedure for assessing the risk of osteoporotic fracture is via bone mineral density (BMD) assessment using dual-energy X-ray absorptiometry (DXA). However, DXA is an expensive technique and is not widely available. Within the past 15 years, ultrasound assessment of bone has rapidly advanced in scientific understanding, technical development and clinical utility. Measurements of cancellous bone (particularly at the calcaneus) are generally performed in preference to those of cortical bone (tibial cortex). There are currently 15 commercial systems available and over 3500 systems are in use world-wide. The low cost and portability offered by ultrasound systems should enable an integrated community-based screening programme to be established in the near future. Ultrasound measurements of bone are generally obtained using transmission rather than pulse-echo techniques owing to its highly attenuating nature. Ultrasound velocity and attenuation measurements are utilized. For velocity, there are well-defined fundamental relationships describing the dependence upon the elasticity and density of bone.

Absorptiometry, Photon↗

An evaluation of a new gel-coupled ultrasound device for the quantitative assessment of bone.

Quantitative ultrasound (QUS) is now being accepted as a tool in the assessment of bone status. Most QUS devices measure broadband ultrasound attenuation (BUA) and speed of sound (SOS). A newly introduced device, the Acoustic Osteo-Screener (AOS-100), measures both SOS and an attenuation related parameter called the transmission index (TI) and provides a derived parameter called osteo sono-assessment index (OSI). The purpose of this study was to examine the reproducibility of this new device, compare the results with the UBA 575+ and evaluate the effect of using two platforms to compensate for different foot sizes on the measured values. 83 subjects aged 21-89 years, who gave informed consent, were recruited. Subjects were assigned to three different groups determined by age and health status. The short-term measurement precision (expressed as root mean square coefficient of variation) of SOS (0.13-0.16%) and TI (1.18-1.96%) was similar to and better than that obtained for the UBA 575+. Significant negative correlations were found between the differences in SOS measured with the two platforms (adaptors to adjust the position of the foot relative to the foot plate) and foot length (p < 0.0001). This implies that small feet are more influenced by the differences of measured location. All QUS parameters measured with the small platform were found to be significantly smaller than those with the large platform (p < 0.0001). The mean percentage differences were 0.6% in SOS, 2.8% in TI and 4.3% in OSI with the large foot platform giving larger value results. Proper use of the platforms resulted in more reproducible SOS and TI. This study demonstrated that the newly developed AOS-100 parameters TI and OSI were highly reproducible. This study also demonstrated that the use of an inappropriate platform can cause discrepancies in QUS readings and poor reproducibility.

Adult↗

Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?

There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, including the spinous processes. In this study, we examined the ability of speed of sound measured at the calcaneus, distal third and ultradistal radius, proximal third phalanx, metacarpal, capitate, patella, and the posterior process of the thoracic spine to differentiate subjects with hip fractures from normal controls. Seventy-nine postmenopausal Caucasian Israeli women who had sustained an atraumatic fracture of the proximal femur within the last 6 months were recruited from the local population (mean age 80 +/- 8.9 years). As controls, 295 postmenopausal Caucasian Israeli women without osteoporotic fractures were also included (mean age 70 +/- 8.7 years). Discrimination of hip fractures with QUS at all ultrasound sites was highly statistically significant (p < 0.01) (odds ratios [ORs] = 1.4-3.0; area under the ROC curve [AUC] 77-92%), except for the hand metacarpal. Distal radius and calcaneus measurements (ORs = 2.4 and 3.0) were the best discriminators of hip fracture patients from controls. Using a forward selective linear regression model, the discriminator values of combined assessment at two sites were investigated. There was moderate improvement in diagnostic value, but the best combination was the calcaneus with the distal radius, which improved the AUC by 3% and raised both the sensitivity and specificity to 94%. These data demonstrate the encouraging potential of improving discrimination of hip fracture by using multiple-site ultrasonic measurements.

Aged↗

Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women.

This study investigated the effect of different sized regions of interest (ROIs) on quantitative ultrasound (QUS) variables of the calcaneus. The effect on QUS of using a fixed ROI as opposed to an ROI adjusted for foot length was also assessed. Eighty Caucasian women, aged 50-57 yr (mean 53 +/- 2) who were healthy and within 0. 5-5 yr of the onset of menopause participated in this study. Using the QUS-1(trade mark) Ultrasonometer (Metra Biosystems, Mountain View, CA), we assessed broadband ultrasound attenuation ([BUA] and UBI-4, dB/MHz), the average transit time through the heel ([TTH], mus) and a multiple-factor index (UBI-4T = UBI-4/TTH, dB/[MHz. mus]). The QUS measurement results were calculated from three different sizes of ROI as well as one in a fixed location and one adjusted for foot size. Bone thickness, bone width, bone mineral content ([BMC], g/cm), bone mineral density area ([BMD(a)], g/cm(2)), and bone mineral density volume ([BMD(v)], g/cm(3)) were measured by single-energy photon absorptiometry. Lateral radiography of the foot was used to ensure the QUS scanning location in a subgroup. The results showed that there was a 1.4-5.9% difference in QUS parameters among different ROIs (p = 0.076-0.001). No significant differences between fixed and adjusted location were found regarding the mean values of QUS. The correlation between the fixed and adjusted locations was very strong, although there was a 12-42% unexplained variation. On the other hand, QUS in the size-adjusted ROI increased the correlation with BMC/BMD compared to the fixed QUS assessments. After controlling for body weight and height, a significant correlation between QUS and bone mass variables remained, and in some cases correlations became stronger. Lateral radiography showed that when using a fixed location to scan a large foot, the scanning area might be close to the bone edge, an area of higher BMD and potential acoustic artifacts. When scanning a small foot, the scanning area was confined to the middle of the calcaneus. Our results indicate that bone size has a modest effect on BUA. There is a better correlation with BMD when the measurement region is appropriately located in the calcaneus. This suggests that measurement location based on foot size may improve the accuracy of the measurements, resulting in good diagnostic sensitivity.

Bone Density↗

Factors influencing the speed of sound through the proximal phalanges.

The amplitude-dependent speed of sound (AD-SOS) in the proximal phalanges is reported to be sensitive to osteoporotic changes. We investigated the influence of bone thickness and cortical thickness on AD-SOS. Phantoms made of Perspex were designed to simulate different bone width (11-16 mm) and cortical thickness (3-7.5 mm). The phantoms were designed with two opposing flat and cylindrical surfaces. The effect of cortical thickness was examined by drilling holes (simulating the medullary canal) of different diameters (1-7 mm) in the middle of the Perspex cylinders. The effect of sample thickness was investigated on solid Perspex phantoms of varied lengths. The standardized precision errors of AD-SOS measurement in vivo and in vitro on volunteers and phantoms were 2.8 and 0.9%, respectively. AD-SOS was influenced by the bone width, cortical thickness, and location along the phalanx. A decrease in either cortical width or cortical thickness resulted in a decrease in AD-SOS. The effect is dependent on whether the contact surface is curved or flat. It is possible that a curved surface has a focusing effect on the wave through the porous core, whereas for a flat surface, the path of the waves might not pass through the center. When cortical thickness and bone width were expressed as a ratio, there was a linear relationship between this ratio and AD-SOS through the phantoms. AD-SOS was independent of thickness for samples greater than 11 mm.

Adult↗

The use of quantitative ultrasound to monitor fracture healing: a feasibility study using phantoms.

Fracture healing has traditionally been monitored subjectively using manual manipulation of the fracture site and evaluation of radiographic images. A more objective method of monitoring would provide obvious advantages, allowing healing progress to be quantitatively assessed and so providing the opportunity for early detection of problems. A tibia phantom was used to investigate whether the longitudinal propagation velocity of ultrasound across a fracture site could be used quantitatively to assess fracture healing. The characteristic of fracture healing simulated by the phantom was the changing gap between the bone ends at the fracture site. The ultrasound velocity was measured using a recently developed machine, the SoundScan 2000 (Myriad Ultrasound Systems Ltd, Israel). The precision of the SoundScan 2000 was found to be 0.4% in vitro. Ultrasound velocity predicted the simulated fracture gap with a high degree of accuracy (R2 = 0.994). The measured and the theoretically calculated velocity for different widths between the simulated bone ends was found to be highly correlated with a coefficient of determination of 0.998. This result shows that the use of quantitative ultrasound to monitor fracture healing warrants further investigation in vivo.

Equipment Design↗

Sound-tissue interaction: the physical basis of bone ultrasonometry and limitations of existing methods.

Ultrasound measurements of bone are generally obtained using transmission rather than pulse-echo techniques because of its highly attenuating nature. Ultrasound velocity and attenuation measurements are utilized. For velocity, there are well-defined fundamental relationships describing the dependence on the elasticity and density of bone. However, the practical implementation and signal processing of velocity measurements has led to a significant variability in results from different commercial systems. We may measure either phase of group velocity, for the latter, adopting a range of pulse arrival definitions. We are offered bone velocity, heel velocity, time of flight, and amplitude-dependent velocity. For attenuation measurements, however, the reverse is true. We generally record the increase in attenuation with frequency (0.2-0.6 MHz), termed broadband ultrasound attenuation (BUA). Although first described in 1984, because of the complex interplay of attenuation mechanisms, there still lacks a fundamental understanding of the dependence of BUA on the material and structural properties of cancellous bone. With the increasing number of commercial systems available, there is an urgent need to understand the intrinsic (artefact free) and system estimation of ultrasound velocity and attenuation parameters that may be implemented to characterise bone and provide clinical information.

Journal Article↗

The role of ultrasound in the assessment of osteoporosis: a review.

Osteoporosis is now being recognized as a "silent epidemic" and there is an increasing need to improve its diagnosis and management. Quantitative ultrasound (QUS) measurement [broadband ultrasound attenuation (BUA) and velocity] is emerging as an alternative to photon absorptiometry techniques in the assessment of osteoporosis. The fundamental principles governing ultrasound measurements are discussed, and some of the commercially available clinical systems are reviewed, particularly in relation to data acquisition methods. A review of the published in vivo and in vitro data is presented. The general consensus is that ultrasound seems to provide structural information in addition to density. The diagnostic sensitivity of ultrasound measurement of the calcaneus in the prediction of hip fracture has been shown by recent large prospective studies to be similar to hip bone mineral density (BMD) measured with dual-energy X-ray absorptiometry (DXA) and superior to spine BMD. Ultrasound has also been shown to correlate better with the type of hip fracture (intertrochanteric or cervical) than BMD and to provide comparable diagnostic sensitivity to spine BMD in vertebral fractures. It has also been observed that combining the results of both ultrasound and DXA BMD significantly improved hip fracture prediction. Areas where further research is required are identified.

Biophysical Phenomena↗

Prediction of human femoral bone strength using ultrasound velocity and BMD: an in vitro study.

The stiffness and strength of cancellous bone are important in the management of skeletal diseases such as osteoporosis. These properties are a function not only of bone density but also of bone architecture, some measure of which can be provided by quantitative ultrasound. The ability of quantitative ultrasound and bone mineral density (BMD) to predict stiffness and strength of human femoral heads removed from live subjects during hip replacement was assessed. Stiffness and strength were measured using a uniaxial compression test. Ultrasound velocity was measured using the pulse-submersion technique (McCue CUBAResearch) and BMD using DXA (Lunar DPX-L). Ultrasound velocity (quantitative ultrasound) and stiffness varied with the three orthogonal directions, the highest significance being between the proximo-distal (PD) and antero-posterior (AP) directions (p < 0.0001 for stiffness and p = 0.0003 for velocity). Ultrasound velocity was significantly correlated with compressive bone strength (r = 0.76, p < 0.0001) and stiffness (r = 0.79-0.83, p < 0.0001). BMD was also significantly correlated with compressive strength (r = 0.82, p < 0.0001) and stiffness (r = 0.66-0.81. p < 0.001). Using multiple regression analysis both BMD and velocity were significant predictors of strength (r = 0.88, p = 0.0004 and 0.0054 respectively) and stiffness (r = 0.92, p = 0.0001 and 0.0003 respectively). BMD and velocity were still independent significant predictors of both stiffness (r = 0.93, p < 0.0001 and 0.0001 respectively) and strength (r = 0.89, p < 0.0001 and 0.02) when they were combined as a product (BMDn*Vm). This suggests that BMD measured using DXA, if used in conjunction with ultrasound velocity, may be able to improve osteoporosis risk assessment. The information about femur anisotropy may also be important for hip prosthesis and in vivo modelling.

Absorptiometry, Photon↗

The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro.

The mechanical status of bones is an important consideration in skeletal pathological conditions such as osteoporosis, which result in fracture at predominantly cancellous bone sites. Density is a good predictor of the stiffness and strength of cancellous bone. However, these mechanical properties are also dependent on the cancellous bone's architecture. The objective of this work was to investigate the ability of ultrasound velocity to predict the Young's modulus of elasticity of cancellous bone. The cancellous bone specimens were 20 mm cubes from bovine femur and 21 mm diameter mediolateral cylinders cored from human calcaneus. Ultrasound velocity (V) and Young's modulus (E) were determined in three orthogonal directions for the bovine cubes [anteroposterior (AP), mediolateral (ML), and proximodistal (PD)], and mediolaterally in the calcaneus. Apparent density (p) was determined after the other tests. Density alone explains 87.6% of the variance of Young's modulus in human calcaneal and bovine femoral bone tested in the PD direction only. Velocity, however, explains 95% and a combination of density and velocity 97%. Velocity and stiffness are not random with respect to the three directions in the bovine specimens. Further, for each cube we obtained the mean of the three values of E and of V, and characterized each value of E and V by their deviation from their mean. There is an extremely strong positive correlation (r = 0.80) showing that the degree of deviation is consistent for E and V, and of the same sign. These results demonstrate that the velocity of ultrasound in cubes of cancellous bone can give structure-specific information. In particular, knowledge of both density and velocity allows better predictions of stiffness than do density or ultrasound velocity on their own. Because there are noninvasive methods of measuring density that do not depend on ultrasonic measurement the combination of these two measurements promises, eventually, to give improved assessment of a bone's weakness and liability to fracture.

Analysis of Variance↗

The effect of cortical endplates on ultrasound velocity through the calcaneus: an in vitro study.

Ultrasound velocity has been reported as a good predictor of bone strength measured in vitro using standard mechanical testing techniques. Such mechanical investigation of bone strength cannot be carried out in vivo, because of the invasive nature of the testing. Therefore to be able to extrapolate the in vitro findings to the clinical situation, the effect of cortex on ultrasound transmission velocity through the calcaneus is required. This was investigated in vitro by measuring ultrasound velocity through samples of different modification using a CUBAResearch ultrasound machine. The different sample modifications were: "whole" (soft tissue removed), "core" (cylindrical sample), "can" (cancellous sample without the cortex) and "def" (defatted cancellous sample). Ultrasound transmission velocity for the various sample modification were highly correlated with each other (r = 0.80-0.97). Coring resulted in a 0.77% increase in the mean velocity. Substituting bone marrow (defatting) with water at room temperature had no measurable effect on the ultrasound velocity. The velocity in the whole samples and the cancellous samples were statistically different with the cortex introducing only a 2% increase in the ultrasound velocity. Therefore the in vivo ultrasound velocity measured at the calcaneus is determined mainly by the cancellous bone component which is more sensitive to osteoporotic changes. Hence the reported ability of ultrasound velocity in vitro to predict bone strength could be expected in vivo.

Aged↗

Radiation dose and in vitro precision in paediatric bone mineral density measurement using dual X-ray absorptiometry.

Dual X-ray absorptiometry (DXA) is one of the most widely used techniques for non-invasive assessment of bone integrity. There is a growing demand for measurement of paediatric bone status. In DXA the principal radiation risks to patients are the carcinogenic and genetic effects. Radiation dosimetry is well established for DXA in adults, but there are limited paediatric data available. We report on a study to estimate the effective doses (EDs) received by typical 5- and 10-year-old children using the paediatric scan mode on the Lunar DPX-L bone mineral density scanner. Entrance surface doses (ESDs) and percentage depth doses for the total body and PA spine scan modes were measured using lithium borate thermoluminescent dosemeters (TLDs) located at the surface and distributed at various organ locations in anthropomorphic child phantoms. The EDs were calculated from the percentage depth doses, amount of each organ irradiated and tissue weighting factors. The ESDs were measured to be 6.0 and 0.12 microGy for the posteroanterior (PA) spine and total body, respectively. PA spine EDs were calculated as 0.28 and 0.20 microSv for the 5- and 10-year-old, respectively. Total body EDs were 0.03 and 0.02 microSv for the 5- and 10-year-old children, respectively. These results compare with an adult ED of 0.21 microSv for the PA spine. They are also more than two orders of magnitude lower than reported ESDs and EDs for paediatric chest X-rays. Bone mineral density (BMD) short-term in vitro precision was 0.5% and 1% in the 5- and 10-year-old phantoms, respectively. In conclusion, the Lunar DPX-L in the paediatric mode has a high precision and very low radiation doses, similar to those reported for the adult mode.

Absorptiometry, Photon↗

Orthogonal relationships between ultrasonic velocity and material properties of bovine cancellous bone.

Osteoporotic fractures follow a period of asymptomatic bone loss and hence bone strength, predominantly in cancellous bone. An effective management of osteoporosis requires an understanding of the mechanical behaviour of cancellous bone including the anisotropic dependence. Ultrasound velocity (V) and elasticity (Young's modulus, E) were measured in the three orthogonal directions in 20 mm cubes of bovine cancellous bone. Student paired t-test analysis showed significant variations in velocity and elasticity for the three orthogonal directions, the highest significance being between proximal-distal (PD) and antero-posterior (AP) directions with t = 5.63 and 4.09 for velocity and elasticity respectively, the lowest significance between medio-lateral (ML) and antero-posterior directions. Elasticity followed a power law relationship with apparent density (p) as reported in the literature, the exponent (b) being direction dependent (b = 1.98 +/- 0.21 for PD, 2.42 +/- 0.24 for AP and 2.03 +/- 0.17 for ML). The adjusted R2 values between elasticity and apparent density were highly significant (79.9% for PD, 81.9% for AP and 85.7% for ML). The relationship between velocity and apparent density is less significant in terms of the amount of variance explained (48.5% for PD, 63.3% for AP and 64.4% for ML). R2 values relating elasticity and velocity were again highly significant (79.4% for PD, 82.9% for AP and 80.5% for ML) and the coefficients, determined by regression analysis, independent of direction. Analysis of velocity, elasticity and density data for a range of reference materials demonstrated that experimentally measured longitudinal wave velocity could be reliably substituted into the bar wave equation (v = square root E/p). This implies that a combination of velocity and apparent density may be an improved indicator of bone fragility than density alone.

Animals↗

Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation.

Broadband ultrasonic attenuation (dB MHz cm-1, nBUA) was determined for specimens from 20 human calcanei, along with apparent density, elasticity (Young's modulus), and compressive strength. The calcanei were modified to provide "whole" (only soft tissue removed), "core" (mediolateral cores corresponding to in vivo measurement region), "can" (cortical end plates removed from core), and "def" (core defatted) samples. The nBUA values for the various modifications were highly correlated. The presence of the cortical endplates creates a significant nBUA, probably due to complex phase interactions. nBUAcan was a good predictor of elasticity (R2 = 75.7%) and strength (R2 = 73.6%). Apparent density was a better predictor of the mechanical variables than nBUA, with R2 values of 88.5% for elasticity and 87.6% for strength. The morphological anisotropy defined by "fabric" for the specimens was extremely uniform. The coefficient of variation in nBUA (40.5%) and compressive strength (64.4%) was significantly greater than for apparent density (23.5%) and fabric (6.7%). It is well known that a power law relationship exists between apparent density and elasticity or strength in cancellous bone. An interesting finding in this work is that there also appears to be a power law relationship between nBUA and apparent density, with an exponent of approximately 2, which, in the light of clinical implications, warrants further investigation.

Aged↗