Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive decisions were caused by some perturbation in the image that aroused the suspicion of the viewer. The remainder apparently arose from within the viewer. Most missed nodules (false-negative reports) also received prolonged visual attention, implying an active decision not to perceive a nodule. The data are interpreted to show that roughly one task-related decision is made during each second of scanning a radiograph. This departs from the central assumption of the traditional signal-detection model based upon one decision per image.

False Negative Reactions↗

Searching for lung nodules. A comparison of human performance with random and systematic scanning models.

The contrast sensitivity of the retina is greatest in the center and decreases rapidly toward the periphery. Therefore, the detection of low-contrast lung nodules depends upon the manner in which the image is sampled by retinal receptors as eye fixations jump across the image during scanning. The scanning performance of two radiologists was compared with two computed models, a systematic and a random scanner. Although radiologists do not seem to have random scanning patterns, their coverage of the image was matched more closely by the random model. This suggests that radiologists employ a scanning strategy that is designed to cover the image of the lungs in a minimum time using the smallest possible visual field. The visual field size that is most effective in detecting nodules during search has a radius of 3.5 degrees visual angle. Nodule detection may be limited by basic neurologic constraints on human scanning performance.

Computer Simulation↗

A visual concept shapes image perception.

Six subjects--three radiologists and three laypersons--were shown a hidden figure picture, a sonogram, a tomogram, and two standard radiographic images while their eye movements were recorded. They were asked to summarize each of the images in one sentence. The distribution of visual attention was found to be related to the assignment of meaning to the image. When the interpretation of the image was correct, visual attention focused on the main subject or radiological abnormality. When the viewers found the images to be ambiguous, visual attention focused on dominant pictorial features such as borders or textured areas. These features were then used to generate a meaningful perception in response to the request for a summary statement. The data are interpreted in terms of a theory that holds that picture perception begins with a parallel global characterization of the scene that uses data from both the retina and memory to form a visual concept. According to this theory, it may be necessary to have seen radiological abnormalities in the past to be able to form an appropriate visual concept for a current abnormality.

Concept Formation↗

An analysis of perceptual and cognitive factors in radiographic interpretation.

Detection of small tumors in chest x-ray films was studied under tachistoscopic viewing conditions designed to stimulate single fixations varying in dwell time, found in free search. Two questions were asked: How much dwell time is required to detect a nodule (experiment 1)? How effective are peripheral inputs in the detection of a nodule (experiment 2)? Our findings indicate that a dwell time of 300 ms was sufficient to detect 85% of the nodules when they were viewed directly. Detection accuracy was reduced by one-half when the tumor was located 5 degrees from the axis of gaze. Taken together with data from eye movement experiments, these results provide useful estimates of perceptual and cognitive parameters of visual search.

Cognition↗

Global detection of symmetry.

Two experimental approaches examined observers' ability to characterize shape symmetry based upon the information obtained within a single fixation. Exp. I tested observers' ability to discriminate among three levels of symmetry on the basis of a 25-msec. presentation. Results indicated that identification accuracy was higher for symmetrical and asymmetrical shapes than for mixed shapes, which contained both symmetrical and asymmetrical components. Exp. II tested observers' ability to detect a given level of symmetry by means of a signal-detection approach. Symmetrical shapes were detected better than asymmetrical shapes. Detectability of mixed shapes was lower than that for both symmetrical and asymmetrical shapes. The results of Exps. I and II demonstrate that observers can characterize shape symmetry on the basis of information available within a single fixation. The data are supportive of the hypothesis that a global response to the over-all configuration of the shape serves to facilitate form perception.

Discrimination, Psychological↗

Interpreting chest radiographs without visual search.

Ten radiologists were shown a series of 10 normal and 10 abnormal chest films under two viewing conditions: a 0.2-second flash and unlimited viewing time. The results were compared in terms of verbal content, diagnostic accuracy, and level of confidence. The overall accuracy was surprisingly high (70% true positives) considering that no search was possible. Performance improved as expected with free search (97% true positives). These data support the hypothesis that visual search begins with a global response that establishes content, detects gross deviations from normal, and organizes subsequent foveal checking fixations to conduct a detailed examination of ambiguities. The total search strategy then consists of an ordered sequence of interspersed global and checking fixations.

Cardiomegaly↗

Intrauterine low density in women over 50. Assessment of significance and recommendations for follow-up.

Patients over 50 years old with intrauterine low density on enhanced computed tomography were analyzed. Uterine volume and volume of intrauterine low density were calculated. Intrauterine low density was expressed as a percent of uterine volume. At 1-year follow-up, 23 (63.9%) had uterine malignancy and 13 (36.2%) had benign findings. All patients whose intrauterine low density exceeded 35% of the total uterine volume had a malignancy (p < 0.001). If intrauterine low density exceeds 35% of uterine volume, evaluation of uterine malignancy should be performed regardless of symptoms.

Aged↗

Visual scanning, pattern recognition and decision-making in pulmonary nodule detection.

Eye movements were recorded while four subjects searched a set of 60 films, 24 normal and 36 abnormal for pulmonary nodules. Error rates, scanning patterns and the dwell time of fixation clusters on normal and nodule-containing areas of the film were studied. Using the assumption that prolonged dwell time indicates intensive processing of visual data, a model was developed for nodule detection that includes four steps: orientation, scanning, pattern recognition and decision-making. False-negative errors were divided into three classes: scanning errors, recognition errors and decision-making errors. Of 20 false-negative errors, 30% were considered scanning, 25% recognition and 45% decision-making.

Decision Making↗

Global and segmented search for lung nodules of different edge gradients.

Chest films were inspected by staff and resident radiologists for lung nodules under two viewing conditions: segmented search, in which films were divided into six sections and viewed piecemeal, and global search, in which the complete film was presented and viewed in its entirety. Nodules varied in edge gradient from sharp to fuzzy. Nodules with sharper edges were identified faster, more frequently, and with higher confidence than nodules with less sharp edges. Segmented search did not increase the probability of nodule detection; rather, it led to an increase in the number of false-positives, resulting in lower overall performance when compared with global search. The results are interpreted according to a visual search model which calls for the use of comparative scanning strategies to differentiate nodule-containing areas from nodule-free areas on chest films.

Decision Making↗

Nodule detection with and without a chest image.

The detectability of nodules displayed on uniform backgrounds was compared with their detectability on chest images by using receiver operating characteristic (ROC) curves. The images were displayed using a digital television system. Two conditions, chest image and uniform background, were compared at three different levels of added random noise. The viewing conditions were made as similar as possible by setting the luminance of the uniform background equal to the luminance of the lung in the chest image. Nodule detectability was significantly lower for the chest image than for the uniform background at each level of added random noise. The anatomic structure of the chest image interferes with the structural integrity of the nodule image resulting in lower detection performance.