PubMed HealthSearch

Biomedical subjects

C F Pope

Publications and source records attributed to C F Pope.

12 recordsLinked to original sources

Normal and abnormal glenoid labrum: assessment with multiplanar gradient-echo MR imaging.

A retrospective study of magnetic resonance (MR) imaging of the glenoid labrum performed with multiplanar gradient-echo (MPGR) sequences was done to ascertain the different appearances of the normal labrum and the findings in patients with tears. MPGR images were obtained with a 1.5-T magnet in 37 shoulders of 16 healthy subjects and 19 patients with subsequent surgical evaluation. Increased intralabral signal intensity was seen in 12 of 26 normal shoulders (46%), and atypical morphology was seen in six shoulders (23%). Atypical morphology was present in eight of nine patients with labral tears. Deformity (n = 2 [22%]) and clefts (n = 2 [22%]) were seen in patients with tears. Deformity (n = 3 [12%]) and clefts (n = 1 [4%]) were occasionally seen in healthy subjects. Absence of the labrum and separation of the labrum from the glenoid cavity was present only in patients with tears; therefore, the labrum should be presumed torn in the presence of these findings. Increased intralabral signal intensity on MPGR images did not help predict labral integrity; morphologic findings were more predictive of labral tear.

Adolescent

Radiologic evaluation of tendon injuries.

This article reviews the imaging choices available to assess the tendons of the shoulder, knee, ankle, and wrist. Principles of tendon imaging and fundamental considerations of computer-derived image techniques are briefly discussed, with particular reference to magnetic resonance imaging. Although the criteria used to classify various tendon abnormalities are provided, the clinical role of imaging is emphasized.

Ankle Injuries

Magnetic resonance imaging of the surgically repaired meniscus: six-month follow-up.

The appearance and rate of healing of sutured meniscal repairs in 17 patients were evaluated using magnetic resonance scans. While prior studies in animals and humans (1-4) suggest that complete healing can occur as early as 6 wk postoperatively, we found that at 7 wk 15/15 patients demonstrated meniscal defects at the site of repair. At 6 mo, 11/11 patients showed persistent signal abnormalities. Two patients scanned at 11-12 mo also had defects at the site of repair. Therefore, complete meniscal healing appears not to occur as early as previously believed. This may affect decisions regarding the type of suture material used, the surgical treatment of associated injuries and the postoperative rehabilitation regimen. As defects may be present for relatively long periods of time following meniscal repair, caution must be exercised when attempting to diagnose new or recurrent tears in these patients.

Adolescent

Technical variables influencing the detection of acute deep vein thrombosis by magnetic resonance imaging.

To establish which technical variables influence the detection of deep vein thrombosis by magnetic resonance imaging, 2 dogs, 5 normal volunteers and 17 patients were studied using a 1.5 T whole-body system. A sequential slice gradient echo acquisition (TR 25, TE 13, 0 = 30 degrees, 2 NEX, flow compensation rephasing gradients) in the axial plane was found to be optimal for detecting venous thrombosis. Thus, when using appropriate technique, MRI may identify deep venous thrombosis accurately. It may also allow the diagnosis of conditions which may simulate venous thrombosis clinically since the most common of these, ruptured Baker's cyst, cellulitis, muscle tear, hematoma and external venous compression are all readily identified by MRI.

Acute Disease

Follow-up of grade 2 meniscal abnormalities in the stable knee.

A prospective study of grade 2 meniscal abnormalities in patients with intact anterior cruciate ligaments was done to ascertain whether such lesions progress to complete tears. A follow-up magnetic resonance (MR) image was obtained in 22 patients in whom the initial MR image showed a grade 2 lesion in one or both menisci that had been proved at arthroscopy not to be torn. On the initial images, 27 menisci contained a grade 2 lesion. At follow-up, six of the 27 lesions appeared to have decreased in size (two had completely disappeared). Eighteen lesions appeared unchanged; only three had increased in size. The mean interval between the acquisition of initial and follow-up images was 27.3 months (range, 11-41 months). The two patients whose lesion disappeared were among the youngest patients evaluated. The three patients whose abnormality increased were slightly older and more active than average. The results suggest that in most patients grade 2 lesions are stable at up to 3 years follow-up.

Adolescent

The clinical significance of stage 2 meniscal abnormalities on magnetic resonance knee images.

The Stage 2 meniscal abnormality was subdivided into Stage 2A--linear abnormal signal not contacting an articular surface, Stage 2B--abnormal signal in contact with the articular surface on a single image, Stage 2C--extensive wedge-shaped signal abnormality not in contact with an articular surface. Arthroscopy showed tears in 2A 3%, 2B 0%, 2C 50%. Complete tears should only be diagnosed if contact is seen on more than one image. Many Stage 2C menisci may have tears.

Adult

A quantitative study of relaxation rate enhancement produced by iron oxide particles in polyacrylamide gels and tissue.

The proton relaxation rate enhancements produced by two types of iron oxide particles, M4125 and AM125 (Advanced Magnetics, Cambridge, MA) designed as potential MR contrast agents, have been measured in polyacrylamide gels and in liver and spleen. The organ uptakes, time courses, and biodistributions of these materials have been measured using radiolabeling. The relaxation rate enhancements produced by these particles have been related to the concentration of iron per gram material at different magnetic field strengths. The relaxation rates increase linearly as a function of concentration at field strengths varying from 0.15 to 7 T. The relaxation effects of these particles in tissue are significantly different from the behavior in vitro. These results suggest that several different mechanisms contribute to relaxation effects in the presence of iron oxide particles and they depend strongly on the way the particles are sequestered. Diffusion effects for a specified TE may be enhanced using gradient or single-spin echoes rather than multiple echoes. AM125 is significantly more effective as a relaxation agent than paramagnetic metal ions only at relatively high fields, while M4125 is less effective per unit concentration.

Acrylic Resins

Quantitation of MR relaxation effects of iron oxide particles in liver and spleen.

The relaxation effects and organ distribution of superparamagnetic iron oxide particles for magnetic resonance imaging were measured in rats. T1 and T2 were measured for excised organs, and tissue iron levels were quantified with radiolabeling. Approximately 70% of the injected dose is present in the liver and 10% in the spleen 1 hour after injection. At 20 MHz, the doses required to reduce liver and spleen T2 to half the normal value, as measured with a Carr-Purcell-Meiboom-Gill sequence, were, respectively, 420 and 830 mumol iron injected per kilogram of rat. The transverse relaxation rates increase linearly with injected dose and showed no evidence of saturation. These results suggest that this material is less effective than previously suggested.

Animals

Detection of platelet deposition at the site of peripheral balloon angioplasty using indium-111 platelet scintigraphy.

Restenosis after balloon angioplasty may be mediated through platelet deposition at the site of arterial dilatation. The purpose of this study was to determine whether platelet deposition at the site of dilatation could be detected using indium-111 platelet scintigraphy. Fifteen patients, aged 60 +/- 9 years, with iliac or femoral (n = 12), renal artery (n = 2) or distal aortic (n = 1) stenoses were studied. All patients received intravenous heparin at the time of dilatation. Labeled platelets containing 471 +/- 65 muCi indium-111 were injected 0.25 to 4 hours after dilatation and 1 to 24 hours after imaging. In 11 of 12 patients with iliac and femoral dilatations, focal uptake was demonstrated at the angioplasty site. In 4 patients (2 patients with renal, 1 patient with iliofemoral, and 1 with distal aortic stenoses), uptake at the dilatation sites was not detected. This preliminary study indicates that despite intravenous heparin, platelets accumulate at sites of balloon dilatation. Platelet scintigraphy may be useful in predicting sites of future narrowing after angioplasty and may be used to test the efficacy of antiplatelet therapy in retarding restenosis.

Adult

Change.

Explore the source record for details and available documents.

Insurance, Dental