PubMed Health⌕ Search

Biomedical subjects

C F Vahl

Publications and source records attributed to C F Vahl.

At least 55 records · Page 3Linked to original sources

Assessment of mitral regurgitant jets by three-dimensional color Doppler.

BACKGROUND: Color Doppler echocardiography is a standard technique for assessing mitral regurgitation before and after mitral valvuloplasty. Mitral valve prolapse produces complex eccentric jet flows that cannot be visualized and measured by two-dimensional color Doppler echocardiography. The aim of this study was to evaluate the clinical impact of three-dimensional color Doppler echocardiography, a new technique developed at our institution, for assessing mitral regurgitation. METHODS: Forty-five patients with mitral regurgitation underwent intraoperative transesophageal echocardiography and three-dimensional Doppler data acquisition. The grade of mitral regurgitation was assessed by angiography. The jet areas were calculated by planimetry from conventional color Doppler; the jet volumes were obtained by three-dimensional Doppler data. RESULTS: New patterns of mitral regurgitant flows were recognized according to the origin, direction, and spatial spreading into the left atrium. Conventional jet areas failed to separate the groups of patients with different degrees of regurgitation, whereas the jet volumes were able to divide patients with different regurgitation grades. No significant correlation was found between jet area and angiographic grading (r = 0.63, p = NS). Jet volumes were significantly correlated to angiography (r = 0.89, p < 0.001). CONCLUSIONS: Three-dimensional color Doppler echocardiography revealed new patterns of regurgitant flow and allowed a more accurate semiquantitative assessment of complex asymmetrical regurgitant jets.

Blood Flow Velocity↗

Modulation of coronary perfusion pressure can reverse cardiac dysfunction after brain death.

BACKGROUND: Brain death results in a rapid decline in left ventricular function, which has clinical relevance for organ transplantation. The aim of the present study was to investigate coronary perfusion changes during brain death and their role in cardiac dysfunction. METHODS: In an in situ isolated canine heart model, brain death was induced by inflation of a subdural balloon catheter. The heart was perfused separately with the animal's own blood by a pressure-controlled roller pump that was coupled to the measured aortic pressure. Myocardial contractility was estimated by the slope of the end-systolic pressure-volume relation. RESULTS: Induction of brain death resulted in a transient hyperdynamic response, followed by a significant decrease in systemic vascular resistance, coronary blood flow, and the end-systolic pressure-volume relation (p<0.05). However, if coronary perfusion pressure was decoupled from aortic pressure and elevated to pre-brain death levels, coronary blood flow and the end-systolic pressure-volume relation were also restored to baseline levels. CONCLUSION: Severe impairment of coronary blood flow may contribute to decreased contractility after brain death that can be reversed by modulation of coronary perfusion pressure.

Animals↗

Simulation of arterial hemodynamics after partial prosthetic replacement of the aorta.

BACKGROUND: Replacing parts of the aorta with a non-compliant vascular prosthesis results in marked alterations of the aortic input impedance and influences arterial hemodynamics. We propose a mathematical model of circulation that can predict hemodynamic changes after simulation of vascular grafting. METHODS: A new mathematical model of the human arterial system was developed on a 75-MHz Pentium personal computer using Matlab software. The human arterial tree was delineated according to a 128-branch design encompassing bifurcations and physical properties of the arterial wall. A digitized aortic flow wave was chosen as the input signal to the system. After determination of the modules of elasticity of native vascular tissue and standard prostheses in technical experiments, replacement of any part of the aorta with a prosthesis was simulated by increasing the elasticity in the parts desired. RESULTS: During control conditions, the model displayed a physiologic distribution of flow and pressure waves throughout the arterial system. Simulated replacement of the aorta resulted in an increase in pressure amplitude and a partial loss of the aortic "Windkessel" function. Calculation of the aortic input impedance showed an increase in the characteristic impedance, whereas the peripheral resistance remained unaltered. CONCLUSIONS: This mathematical model of the arterial circulation is useful for simulating hemodynamic changes after implantation of vascular grafts. The results of the model analysis are consistent with those in previous experimental work.

Aorta↗

Three-dimensional color Doppler: a clinical study in patients with mitral regurgitation.

OBJECTIVES: The purpose of this study was to assess the clinical feasibility of three-dimensional (3D) reconstruction of color Doppler signals in patients with mitral regurgitation. BACKGROUND: Two-dimensional (2D) color Doppler has limited value in visualizing and quantifying asymmetric mitral regurgitation. Clinical studies on 3D reconstruction of Doppler signals in original color coding have not yet been performed in patients. We have developed a new procedure for 3D reconstruction of color Doppler. METHODS: We studied 58 patients by transesophageal 3D echocardiography. The jet area was assessed by planimetry and the jet volumes by 3D Doppler. The regurgitant fractions, the volumes, and the angiographic degree of mitral regurgitation were assessed in 28 patients with central jets and compared with those of 30 patients with eccentric jets. RESULTS: In all patients, jet areas and jet volumes significantly correlated with the angiographic grading (r = 0.73 and r = 0.90), the regurgitant fraction (r = 0.68 and r = 0.80) and the regurgitant volume (r = 0.66 and r = 0.90). In patients with central jets, significant correlations were found between jet area and angiography (r = 0.86), regurgitant fraction (r = 0.64) and regurgitant volume (r = 0.78). No significant correlations were found between jet area and angiography (r = 0.53), regurgitant fraction (r = 0.52) and regurgitant volume (r = 0.53) in the group of patients with eccentric jets. In contrast, jet volumes significantly correlated with angiography (r = 0.90), regurgitant fraction (r = 0.75) and regurgitant volume (r = 0.88) in the group of patients with eccentric jets. CONCLUSIONS: Three-dimensional Doppler revealed new images of the complex jet geometry. In addition, jet volumes, assessed by an automated voxel count, independent of manual planimetry or subjective estimation, showed that 3D Doppler is also capable of quantifying asymmetric jets.

Adult↗

Three-dimensional color Doppler: a new approach for quantitative assessment of mitral regurgitant jets.

Color Doppler echocardiography does not provide adequate information about the severity of mitral regurgitation in patients with eccentric mitral regurgitation. We have developed a new procedure for 3-dimensional (3D) color Doppler reconstruction and for segmentation of regurgitant jets. The volume of regurgitant jets was compared with jet area in 63 patients with mitral regurgitation. Mitral regurgitation was assessed by angiography, regurgitant fraction and volume by pulsed Doppler, JA by planimetry, and JV by 3-dimensional Doppler. Twenty-eight patients with central jets were compared with 35 patients with eccentric jets. In the patients with eccentric jets, JV showed significant correlations with regurgitant volume (r = 0.90; P <.01) and regurgitant fraction (r = 0.76; P < .01) and was able to separate groups with different degrees of mitral regurgitation (P <.01). Three-dimensional Doppler revealed origin, direction, and spatial spreading of complex jet geometry. JV, a new parameter of mitral regurgitation, was also capable of quantifying asymmetrical jets.

Echocardiography, Doppler, Color↗

Three-dimensional color Doppler for assessing mitral regurgitation during valvuloplasty.

OBJECTIVE: Transesophageal color Doppler (or 2D Doppler) is the most widely used technique for intraoperative assessment of mitral valve repair. However, the most severe mitral regurgitations produce eccentric jet flows which cannot be assessed by 2D imaging. Up to now the indications for surgical intervention and intraoperative decisions after valve repair have been based on 2D Doppler examinations. Aim of this study was to compare conventional 2D Doppler to three-dimensional (3D) Doppler for assessing residual regurgitation in patients after mitral valvuloplasty. METHODS: Twenty-four patients were referred to surgery for mitral valve repair. They underwent transesophageal echocardiography and 3D data acquisition during mitral valve reconstruction. Conventional assessment of mitral valve regurgitation, measured by color Doppler jet area, was compared to the volume of regurgitant jets obtained by 3D Doppler. Regurgitant volume and fraction were measured by pulsed Doppler and two-dimensional echocardiography. The 3D reconstructions of color Doppler data were accomplished by means of the 'Heidelberg Raytracing Algorithm' developed at our institution. RESULTS: The jet areas did not show any significant correlation to the regurgitant fraction (r = 45; P = NS) or regurgitant volumes (r = 0.40; P = NS). In contrast the jet volumes correlated significantly to regurgitant fraction (r = 0.71; P < 0.01) and regurgitant volume (r = 0.85; P < 0.01). The reproducibility analysis of repeated jet volume and jet area measurements also showed that the parameter jet volume has a lower variability and higher agreement of repeated measurements than jet area. CONCLUSIONS: Three-dimensional color Doppler flow imaging revealed the complex geometry of eccentric regurgitant jets and showed that the assessment of mitral regurgitation, based on conventional 2D Doppler, can be misleading. This new technique has a great potential for becoming a reference method for assessing mitral valve repair.

Blood Flow Velocity↗

The meaning of early mortality after CABG.

OBJECTIVE: Investigations of early mortality after coronary artery bypass grafting (CABG) are predominantly based on 30-day mortality or hospital mortality. The advantages, disadvantages, and usefulness of hospital mortality and 30-day mortality analyses to investigate the early risk after CABG are evaluated. METHODS: A total of 4985 patients underwent isolated CABG from June 1988 to June 1997. A follow-up was performed 180 days after CABG (response rate: 98.6%). RESULTS: The mean hospital stay was 13.5+/-9.6 days, the range was 0 to 142 days (25% quartile, 9 days; median, 12 days; 75% quartile, 15 days). The hospital mortality was 5.3%. The 30-day mortality was 5.6%. The non-parametric Kaplan-Meier curve of the time interval 0-180 days postoperatively proves the persistence of the still decreasing behaviour of the survival curve beyond the 30th day until about the 60th postoperative day. Stratified by era of operation, the 'early phase' after CABG seems to be prolonged beyond 30 days at least for the more recent operation era since 1991. Risk stratification proves that the higher the risk group, the more the early phase tends towards a prolongation. CONCLUSIONS: The hospital mortality reflects institutional habits concerning postoperative patient care. Therefore, a systematic underestimation of early mortality is likely. In contrast to hospital stay, the evaluation of 30-day mortality requires a follow-up procedure but allows interinstitutional comparisons. Nevertheless, 30-day mortality systematically underestimates the early risk, at least in the more recent CABG period. So, a standardized evaluation of a longer time period (p.e. 180 days) is recommended.

Coronary Artery Bypass↗

Surgical treatment of oligosymptomatic mitral valve incompetence?.

OBJECTIVE: Despite improvements of the surgical technique in NYHA (III)-(IV) mitral valve incompetence (MVI) postoperative long-term results remain poor. As long-term results reflect primarily the ventricular function rather than the quality of the surgical technique the contractile performance of isolated papillary muscles obtained from patients undergoing mitral valve replacement for MVI (n = 25) was analysed in detail. METHODS: Muscle preparations (0.4 x 5.0 mm) obtained from left ventricular papillary muscles (NYHA (I), n = 4; NYHA (II), n = 7; NYHA (III), n = 8; NYHA (IV), n = 6) were loaded for intracellular calcium measurements with FURA-2, stretched to optimal length (Lmax) and electrically stimulated with frequencies ranging from 30 to 180 beats/min (b.p.m.) (10% above threshold, 37 degrees C, Krebs-Henseleit solution). Isometric force development and diastolic intracellular calcium (measured by the 'ratio method'; excitation light: wavelengths alternating 340 and 380 nm, frequency: 250 Hz) were simultaneously recorded as a function of the stimulation frequency. RESULTS: At 60 b.p.m. force development was significantly higher in NYHA (I) myocardium (21.3 +/- 2.8 mN/mm2) than in NYHA (III) myocardium (12.8 +/- 2.2 mN/mm2), (P < 0.0001). In NYHA (I) myocardium force rose with increasing stimulation frequency ('positive staircase'). In contrast the stimulation frequency associated with maximum force was shifted towards lower frequencies in NYHA (II)-(IV) myocardium ('negative staircase'). As compared with NYHA (I) myocardium diastolic intracellular calcium was significantly elevated at 150 b.p.m. in NYHA (II)-(IV) myocardium (P < 0.01). CONCLUSION: The data show, that severe impairment of contractile function ('negative staircase phenomenon', reduced force, elevated diastolic calcium) is present in MVI classified as NYHA (III)-(IV) that may explain the poor long-term results. Most interestingly the data argue for a significant impairment of myocardial function even in NYHA (II) MVI. The results suggest an early surgical treatment of mitral valve incompetence as long as the myocardial function is normal (NYHA (I)) as (1) a reduced perioperative risk, (2) improved long-term results, and (3) a higher probability for mitral valve repair (instead of replacement) may be expected in these early stages of mitral valve disease.

Biopsy, Needle↗

Three-dimensional Doppler. Techniques and clinical applications.

AIMS: Colour Doppler is the most widely used technique for assessing valve disease, but eccentric regurgitant jets cannot be visualized and measured by conventional 2D techniques. We have developed a new procedure for three-dimensional (3D) reconstruction of colour Doppler signals. METHODS AND RESULTS: Fifty patients with mitral regurgitation underwent transoesophageal echocardiography and 3D acquisition. The severity of mitral regurgitation was assessed by angiography and the regurgitant volumes were measured by pulsed Doppler. The jet areas were calculated by planimetry from conventional colour Doppler; the jet volumes were obtained by 3D Doppler. A higher degree of mitral regurgitation was found in the patients with eccentric jets. While jet areas showed poor correlation with regurgitant volumes (r = 0.61), jet volumes correlated significantly with regurgitant volumes (r = 0.93; P < 0.001). While jet areas failed to identify patients with different grades of regurgitation, jet volumes could so discriminate. CONCLUSIONS: 3D Doppler revealed new patterns of regurgitant flow and allowed a more accurate semiquantitative assessment of complex asymmetrical regurgitant jets. Three-dimensional colour Doppler has a great potential for becoming a reference method for the assessment of patients with heart valve disease.

Adult↗

Influence of follow-up response on risk-factor analysis.

BACKGROUND: Long-term analyses after coronary artery bypass grafting (CABG) are used to investigate therapeutical options and factors influencing the natural course of ischemic heart disease. In general, long-term studies require a follow-up. Dependent on the interval between the intervention and the follow-up procedure a certain amount of patients is lost to follow-up. The aim of the present study was to examine the influence of incomplete follow-up on conclusions regarding the postoperative patient outcome. For the investigation, the same statistical methods were applied to the data accumulated by the 70% and by the 90% responses. METHODS: 2012 patients underwent isolated CABG between June 1988 and December 1992. For data acquisition, tools of the HVMD (Heidelberger Verein für multizentrische Datenanalyse e.V.) were used. Analyses were performed using tools of SAS (Statistical Analysis Systems, Inc.). The parametric, time-adjusted hazard function method was employed. A first follow-up questionnaire, was distributed six months after operation with a 97.8% response. In February 1997 the same questionnaire was sent to patients and their general practioners. The primary response to that was 68.9% (approximately 70%). Then another mailing of the same questionnaire and phone calls to patients and their home doctors raised the response to 93.7% (approximately 90%). RESULTS: The mean follow-up was 1378 days in the group with 70% response and 1682 days in the group with 90% response. The parametric, time-adjusted hazard function showed a very similar pattern of factors in the early phase of both groups. In the 90% response group, the intermediate phase reached a higher relative influence than in the 70% response group. The relative influence of the late phase showed an inverse pattern. In the multivariate analysis most of the variables which had been identified by the 70% response model reappeared in the 90% response model. However, there were some potentially important and interesting differences. CONCLUSIONS: The results indicate the necessity to carefully consider the acceptance of incomplete follow-up for differentiated risk adjustment.

Coronary Artery Bypass↗

A new diagnostic procedure for assessing intracardiac flow disturbances in patients with heart valve disease.

BACKGROUND: Until now no diagnostic technique was available for the three-dimensional (3D) study of intracardiac blood flow abnormalities in patients with heart valve disease. 3D color Doppler is a new diagnostic technique first developed at our institution. METHODS: The 3D reconstructions of the blood flow velocity data have been obtained from conventional multiplanar transesophageal or transthoracic Doppler echocardiographic examinations. We analyzed 111 reconstructions of color Doppler data obtained from 85 patients with different heart valve diseases who underwent intraoperative transesophageal echocardiography. Sixty-nine patients had a significant mitral regurgitation, 7 mitral stenosis, 9 aortic regurgitation, 12 aortic stenosis, 14 tricuspid regurgitation. Three patients had pulmonary regurgitation associated with mitral valve disease. RESULTS: 3D color Doppler disclosed the complex spatial spreading of the blood flow abnormalities caused by heart valve disease. New patterns of intracardiac blood flow disturbances could be observed and classified. CONCLUSIONS: This paper shows the first clinical applications of 3D color Doppler in patients with heart valve disease. The new insights derived from the 3D study of intracardiac blood flow dynamics revealed a great impact of this technique on the clinical management of patients with heart valve disease.

Coronary Circulation↗

Actions of ketamine and its isomers on contractility and calcium transients in human myocardium.

BACKGROUND: Ketamine has a species-dependent inotropic effect on myocardium. The authors' aim was to investigate the direct inotropic effect and the corresponding intracellular Ca2+ transients of ketamine and its isomers on human myocardium. METHODS: Right auricular myocardial strips obtained during open heart surgery were exposed to increasing concentrations (73 microM, 360 microM, and 730 microM) of racemic ketamine (n = 12), S(+)-ketamine (n = 12), or R(-)-ketamine (n = 11). Isometric force, isotonic shortening, contractility, relaxation, and time to maximal isotonic and isometric force were assessed. Ten muscle strips in each group were loaded with the calcium-sensitive fluorescent dye FURA-2/AM for simultaneous measurements of calcium transients. RESULTS: Compared with the initial control maximal isometric developed force, maximal isotonic shortening amplitude, contractility, and relaxation increased by 12.5-22.4% after perfusion with S(+)-ketamine at the concentration of 73 microM (P < 0.05). In contrast, no changes were seen after addition of 73 microM R(-)-ketamine. The effect of racemic ketamine (73 microM) was between that of the two isomers. At the highest concentration (730 microM) ketamine and its isomers decreased maximal isometric developed force, maximal shortening amplitude, contractility, and relaxation by 26.8-57.4% (P < 0.05), accompanied by a significant decrease of the intracellular calcium transient (by 21.0-32.2%, P < 0.05). CONCLUSIONS: In contrast to R(-)-ketamine, S(+)-ketamine increased isometric force, isotonic shortening, contractility, and relaxation at low concentrations (73 microM) compared with the initial control. At higher concentrations (730 microM) a direct negative inotropic action was observed after perfusion with ketamine and its isomers, which was accompanied by a decreased intracellular Ca2+ transient.

Adult↗

Mathematical modelling of extracorporeal circulation: simulation of different perfusion regimens.

Computer- and sensor-aided control of the heart-lung machine is considered a major goal for perfusion sciences for the next few years. At present, control of perfusion is achieved by surgeons, anaesthesiologists and perfusionists making short-term decisions, which leads to variations of the perfusion regimens between different centres and even between different teams in the operating theatre. As the basis for an integrated control of extracorporeal circulation (ECC), we proposed a mathematical model for simulating haemodynamics during pulsatile perfusion. This model was then modified to allow it to simulate the effects of different perfusion regimens on arterial haemodynamics and whole body oxygen consumption. The model was constructed on a PC using MATLAB/SIMULINK. The human arterial tree was divided into a multibranch structure consisting of 128 segments characterized by their particular physical properties. Peripheral branches were terminated by a resistance term representing smaller vessels like arterioles and capillaries. Flow and pressure were expressed by the intensity of current and voltage in an electrotechnical analogon; inductivity, resistance and capacitance were implemented according to the physical properties of the arterial tree and the rheology of blood. The effects of different perfusion regimens (pulsatility, flow amount, acid-base regulation) were studied. After introducing an input signal to the model, flow and pressure waves established themselves throughout the simulated arterial tree. During the simulation experiments, marked differences among different perfusion regimens were displayed by the model. Variations in acid-base management mainly influenced the distribution of perfusion: during simulation of low-flow perfusion (1.2 l/min/m2), cerebral blood flow was 6.2 ml/s using an alpha-stat regimen, while it was increased to 9.4 ml/s during pH-stat, caused by an implementation of reduced cerebral resistance. Whole body oxygen consumption was predominantly regulated by the perfusion rate. While central venous oxygen saturation was calculated to be 84.7% during simulation of high-flow perfusion (2.4 l/min/m2), it dropped to 70% during simulation of low-flow perfusion regimens. The model proved to be useful for a realistic simulation of different perfusion regimens. Therefore it can be considered a continuing step for the derivation of a 'state' observer leading to the realization of an automatically controlled heart-lung machine.

Blood Transfusion↗

Length dependence of calcium- and force-transients in normal and failing human myocardium.

UNLABELLED: Two questions were analysed: (1) Is the Frank-Starling mechanism operative in failing human myocardium? (2) Are length-dependent changes in force accompanied by length-dependent changes in intracellular calcium transients in human myocardium? METHODS: (I) in electrically stimulated left-ventricular trabeculae [normal donor heart (NDH), n = 8; end stage dilated cardiomyopathy (DCM), n = 11], isometric force development was analysed as a function of muscle length (37 degrees C, oxygenated Krebs-Henseleit solution, supramaximal electrical stimulation, frequency: 1 Hz). (II) Myocardium from the same patients were loaded with the fluorescent dye FURA-2/AM for simultaneous measurements of intracellular calcium transient (ICT) and force development at different muscle lengths. Muscle length, resting force, developed force and intracellular Calcium ("ratio method") were monitored continuously. RESULTS: (I) developed force increased up to an optimum as a function of muscle length in NDH- and DCM-myocardium. The slope of this increase was flatter in DCM-myocardium (P < 0.01). (II) In NDH- and DCM-myocardium, diastolic and systolic calcium increased significantly with muscle length. With decreasing muscle lengths the ICT became broader, the diastolic decay was retarded and the peak of the ICT was flatter. At Lmax the calcium amplitude was 23% smaller in DCM than in NDH (P < 0.04). CONCLUSION: there is a clear length dependence of active force in DCM-myocardium. The length dependence of force development is associated with length-dependent modulations of the ICT. The flatter slope of the length-force curve in DCM may be partly explained by altered intracellular calcium handling in failing myocardium.

Calcium↗

Metabolic recovery of isolated adult rat cardiomyocytes after energy depletion: existence of an ATP threshold?

The question was investigated whether cardiomyocytes can be resuscitated after extreme energy depletion, i.e. after loss of ATP >70%. Isolated ventricular cardiomyocytes of the adult rat were exposed to metabolic inhibition with dinitrophenol and cyanide (DNP 0.2 mm; KCN 2 mm). After rapid energy depletion, cells were "reoxygenated" by wash-out of DNP and KCN. Intracellular calcium, cell length, ATP and creatine phosphate (CrP) of the cardiomyocytes were monitored. Metabolic inhibition resulted in a depletion of the stores of ATP and CrP by more than 95% of the normoxic values and caused a cytosolic Ca2+ overload. Parameters of metabolic recovery were: (i) resynthesis of CrP; (ii) recovery of a normal cytosolic Ca2+ control; and (iii) the elicitation of energy-dependent hypercontracture. "Reoxygenation", i.e. wash-out of metabolic inhibitors, reactivated oxidative phosphorylation. Consecutively, CrP levels recovered to 76.0+/-7.3%, ATP levels recovered to 10. 4+/-2.3% (means+/-s.dn=10) of the initial normoxic values, a normoxic intracellular calcium level was re-established and hypercontracture was elicited. Prolongation of metabolic inhibition with KCN (2 mm) or inhibition of the Na+/K+ pump with ouabain (0.5 mm) disabled the cardiomyocytes to recover from cytosolic Ca2+ overload and prevented hypercontracture. It is concluded that even after extensive energy depletion metabolic resuscitation of the myocardial cell remains possible and a critical range of ATP for recovery, i.e. a "threshold" of a 70% loss of ATP, does not exist.

Acidosis↗

L-arginine: effect on reperfusion injury after heart transplantation.

Global myocardial ischemia and reperfusion injury play a major role in early postoperative myocardial graft dysfunction. The aim of the present study was to investigate the effects of the nitric oxide (NO) precursor L-arginine on myocardial and endothelial function after hypothermic ischemia and reperfusion in a heterotopic rat heart transplantation model. After 1 hour ischemic preservation, reperfusion was started after application of placebo (control, n = 12) or L-arginine (L-Arg 40 mg/kg, n = 12), a substrate of NO synthesis. Myocardial blood flow (MBF) was assessed by the hydrogen clearance method. An implanted balloon was used to obtain pressure-volume relations of the transplanted heart. Left ventricular developed pressure (LVDP), rate of pressure development (dP/dt), end-diastolic pressure (LVEDP), isovolumic relaxation constant (TE), and MBF were measured after 60 minutes and 24 hours of reperfusion. endothelium-dependent vasodilatation in response to acetylcholine (ACh) and endothelium-independent vasodilatation in response to sodium nitroprusside (SNP) were also determined. After 1 hour the MBF was significantly higher in the L-Arg group (3.6 +/- 0.6 vs. 1.9 +/- 0.2 ml/min/g, p < 0.05). The L-Arg group showed better recovery of systolic function and myocardial relaxation (LVDP 106 +/- 6 VS. 70 +/- 7 mmHg, p < 0.05; maximal dP/dt 5145 +/- 498 vs. 3410 +/- 257 mmHg/s, P < 0.05; TE 12.1 +/- 0.9 vs. 16.1 +/- 1.5 ms, p < 0.05, at an intraventricular volume of 80 microliters). LVEDP was similar in the two groups. After 24 hours no difference was found between the groups for basal MBF, LVP dP/dt, TE, LVEDP, or the response of MBF to SNP. However, ACh led to a significantly higher increase in MBF in the L-Arg group (52 +/- 8% vs. 29 +/- 7%, p < 0.05). These results indicate that (1) NO donation improves myocardial and endothelial functional recovery during early reperfusion after heart transplantation; and (2) initial treatment with L-Arg has a persisting beneficial effect against reperfusion-induced graft coronary endothelial dysfunction during late reperfusion.

Acetylcholine↗

[Surgery of acute aortic valve endocarditis: prognosis in paravalvular abscess].

The occurrence of paravalvular abscesses in the course of an acute endocarditis of the aortic valve indicates an advanced stadium of the disease. The infection has spread beyond the limits of the valve leaflets, and ongoing destruction of the paravalvular tissue is to be expected, if the endocarditis is continually treated by antibiotics alone. Surgery of acute endocarditis with paravalvular abscess, however, supposedly carries an increased risk of early mortality and late morbidity. The following prospective study was carried out to determine whether a radical surgical approach together with aggressive postoperative antibiotic therapy could help to improve results. Between 1988 and 1995, 138 patients were operated during the acute phase of infective endocarditis; in 102 the aortic valve was involved. Among these, 44 had paravalvular abscesses at the time of surgery. The mean age of both groups was the same, but there was a higher rate of concomitant coronary artery disease, multiple valve involvement, advanced NYHA-class, and staphylococcal disease among the patients with abscesses. All interventions were carried out with cardiopulmonary bypass and cardioplegic arrest. The aortic valve was resected, abscesses were removed, and each part of potentially infected or necrotic tissue was resected as complete as possible, irrespective of the possibility to jeopardize the conduction system or to create large tissue defects. The aortic valve was replaced with a mechanical prosthesis in each case. The postoperative antibiotic regimen was specifically directed against the microorganisms isolated preoperatively; therapy was only modified, if signs of systemic infection did not disappear three days after surgery. The operative mortality was 10% among patients without an abscess and 11% in patients with a paravalvular abscess. Early recurrent endocarditis was recorded in two patients without and in only one patient with an abscess. Late recurrent endocarditis was noted in three patients; none of them had abscesses at the time of surgery. We conclude that the operative risk of acute endocarditis of the aortic valve with a paravalvular abscess does not have to be inevitably higher compared to cases without paravalvular involvement. To achieve these results, it is necessary to use a radical surgical approach and to adjust postoperative antibiotic therapy, if infectious signs do not disappear shortly after surgery.

Abscess↗

Operation for infective endocarditis: results after implantation of mechanical valves.

BACKGROUND: Operation for acute endocarditis during the active phase violates a basic surgical rule not to implant a foreign body into an infective process, resulting in a high operative mortality and the risk of early recurrent endocarditis. Several investigators analyzing risk factors for perioperative mortality and morbidity presented strategies for more favorable outcomes, but most studies suffer from the drawback of heterogeneous populations observed over a long period of time. METHODS: We present a prospective study on 138 patients operated on from March 1988 to March 1996. Patients were only included if the activity of the infection was proved by positive culture of the valve leaflets or by histologic staining. During the observation period, indication for operation, surgical approach, and postoperative antibiotic therapy were standardized as much as possible. After radical debridement of all parts of infected tissue, valve replacement was carried out with mechanical prostheses. RESULTS: The early mortality was 11.5% overall. High New York Heart Association functional classification, advanced age, and staphylococcal disease were significant risk factors for early mortality. The site of infection, multiple valve involvement, and prosthetic valve endocarditis did not affect the outcome. Early recurrent endocarditis was recorded in only 3 patients of the entire series. CONCLUSIONS: In case of acute infective endocarditis, valve replacement with mechanical prostheses is a safe procedure, if radical operation and aggressive postoperative antibiotic therapy are performed. For further improvements of the results, earlier operation is advisable in patients with rapidly progressive cardiac deterioration and in most cases of staphylococcal endocarditis.

Acute Disease↗