PubMed HealthSearch

Biomedical subjects

C Fechner

Publications and source records attributed to C Fechner.

6 recordsLinked to original sources

Renal response to hemorrhage in dogs with subacute biliary obstruction.

In the present study, we tested the hemodynamic and renal response of 15 sham-operated dogs and 15 dogs with subacute (5-9 days) biliary obstruction to either acute or more chronic hemorrhage. All studies were conducted on sedated but unanaesthetized animals. Both groups were comparable before blood withdrawal with respect to central hemodynamics and renal perfusion. Serum bilirubin was 0.70 +/- 0.09 mg/dL for control dogs and 8.25 +/- 0.14 for experimental dogs (P less than 0.05). In the acute protocol, nine control and seven jaundiced dogs were bled over a period of 30-40 min to lower blood pressure by 19.1 and 19.5%, respectively. Blood volumes required to achieve this drop were 21.3 and 20.05 mL/kg, respectively (P greater than 0.05). Cardiac output declined by an equivalent value for each group and glomerular filtration rate and clearance of p-aminohippurate remained unchanged from control values. In six control and eight experimental dogs, 500 mL of blood was withdrawn over 5 days. Although blood pressure and cardiac output declined for each group by an equivalent amount, renal perfusion remained unchanged for each group from control values. We conclude that acute or chronic hemorrhage of modest degree does not predispose to acute renal insufficiency in dogs with subacute biliary obstruction.

Acute Disease

Suitability of commercial control sera for the quality control of activity determination of alkaline phosphatase.

The suitability of thirteen commercially available control sera for measuring alkaline phosphatase (EC 3.1.3.1; orthophosphoric acid monoester phosphohydrolase, ALP) activity in human serum was tested. Apart from differences in ALP activity observed in some reconstituted commercial sera, the behaviour of control materials towards experimental variables such as the nature and concentration of the substrate, pH and type of buffer (or PO4-acceptor) together with the composition of the isoenzymes present in human serum highlights the problems and difficulties if commercial materials are to be used as control sera. The half-saturation constants in control sera were in all cases smaller than those of ALP isoenzymes from bone and liver. The shape of substrate activity curves and the pH optimum in most of control sera differed from that of human serum. The discrepant kinetic data of control materials and human serum may mask or suggest changes relevant to commercial quality control serum but not to samples of human serum.

Alkaline Phosphatase

Suitability of commercial enzyme control sera for the quality control of activity determinations of L-aspartate aminotransferase and L-alanine aminotransferase in human serum.

Details of a systematic approach to suitability testing of commercial control sera are given for substrate optimized L-aspartate aminotransferase and L-alanine aminotransferase methods at 37 degrees C. Their acceptability for control purposes of standardized methods depends on: (1) the range of control values in relation to borderline values, (2) stability, (3) aspect, clarity, (4) NADH consumption in preincubation time, (5) blank activities, (6) kinetic data as half saturation constants and saturation curves, (7) influence of effectors, (8) isoenzyme pattern. These evaluation criteria are proposed for suitability testing. The term "representativeness" should be introduced as a special criterion for main characteristics of control materials. The authors want to point out the close connection with standardization of methods.

Absorption

Influence of auxiliary enzymes on the spectrophotometric measurement of alanine aminotransferase and aspartate aminotransferase activities.

We investigated the enzyme activity of the blank in the spectrophotometric determination of the aminotransferase activities and aspartate aminotransferase activity. 6 lactate dehydrogenase and 3 malate dehydrogenase preparations from different manufactures and from different organs showed additional and contaminating activity. The additional activity depends upon the 2-oxoglutarate concentration. The contaminating activity is caused by alanine aminotransferase and aspartate aminotransferase in the auxiliary enzymes. We propose that exact definitions must be given for the auxiliary enzymes in the recommendations of standard determinations for enzyme activities.

Alanine Transaminase