High-resolution backscatter electron imaging of colloidal gold in LVSEM.

High-resolution backscatter electron (BSE) imaging of colloidal gold can be accomplished at low voltage using in-lens or below-the-lens FESEMs equipped with either Autrata-modified yttrium aluminium garnet (YAG) scintillators doped with cerium, or with BSE to secondary electron (SE) conversion plates. The threshold for BSE detection of colloidal gold was 1.8 keV for the YAG detector, and the BSE/SE conversion was sensitive down to 1 keV. Gold particles (6, 12 and 18 nm) have an atomic number of 79 and were clearly distinguished at 500,000x by materials contrast and easily discriminated from cell surfaces coated with platinum with an atomic number of 78. BSE imaging was relatively insensitive to charging, and build up of carbon contamination on the specimen was transparent to the higher energy BSE.

Electrons↗

Improved preservation of rat epididymal sperm for high-resolution low-voltage scanning electron microscopy (HR-LVSEM).

Various fixation protocols were used in an attempt to improve preservation of rat epididymal sperm for high-resolution low-voltage scanning electron microscopy (HR-LVSEM). Wash solutions and fixatives of different composition and osmolarity were tested. Paraformaldehyde and glutaraldehyde concentrations were varied between 0.5% and 3%. Ruthenium red was tested as an additive in both primary fixation and postfixation, or in postfixation alone. HR-LVSEM revealed various degrees of ruffing, folding, blebbing, and peeling off of the plasma membrane, as well as holes of different sizes. The plasma membrane overlying the acrosome and the connecting piece proved to be particularly sensitive to varying fixation conditions. Consistent topographical differences were revealed among the different domains over the sperm head. Most of the differences were considered to be artifacts. Their consistency, however, suggests that structural and biochemical differences exist either within the membrane or in the structures subjacent to the membrane. Primary fixation turned out to be less critical than postfixation. Preservation of a smooth plasma membrane without holes could only be achieved when primary fixation in low aldehyde concentrations, with or without ruthenium red, was followed by postfixation with OSO4 and 1,000 ppm ruthenium red. Examination of thin sections of the same material confirmed that even a considerable number of small holes are difficult to detect in transmission electron microscopy. These results show that with the recent increase in resolution of LVSEM there is need for further effort to improve sample processing.

Animals↗