Angiotensin converting enzyme activity in infancy is related to birth weight.

AIMS: (a) To measure infant angiotensin converting enzyme (ACE) activity in healthy term infants at birth and during the first three months of life. (b) To determine the relation between serum ACE activity and infant feeding practice during this period. (c) To investigate the relation between serum ACE activity and birth weight and other potential contributing factors including acid-base status at birth, gestation, and maternal ACE genotype. METHODS: Prospective study of term infants, with clinical and feeding data collected from parents and medical records, and serum ACE measured in the infant at birth and 1 and 3 months of age, and in the mother at the time of birth and one to three months after birth. RESULTS: At birth and 1 and 3 months of age, infant serum ACE activity was twice that of maternal ACE activity. Infant ACE activity at birth and 1 and 3 months did not significantly differ between breast and formula fed infants. There was a highly significant negative correlation between infant ACE activity at 3 months and birth weight (r = -0.52; p < 0.001). This persisted after the conversion of birth weights to z scores (r = -0.34; p = 0.03). ACE activity at 3 months was also related to placental weight (r = -0.30; p = 0.02) and maternal age (r = -0.30; p = 0.05). The strong correlation between serum ACE activity and birth weight z score persisted after adjustment for maternal age and placental weight (r = -0.34; p = 0.03). CONCLUSION: As ACE is increasingly identified as a risk factor for cardiovascular disease, serum ACE activity in infancy may contribute to the link between low birth weight and later cardiovascular events.

Aging↗

The case of the floating gel.

In patients with chronic renal failure, blood samples for laboratory analysis are often taken via dialysis catheters. This report describes a case of gross spurious hypernatraemia in a blood sample collected from a patient undergoing haemodialysis. After centrifugation of the blood sample in question, the separator gel formed the topmost layer, with the serum in the middle and the clot at the bottom. Subsequent analysis of the serum showed severe hypernatraemia (serum sodium, 744 mmol/litre). It was established that the blood sample had been taken from the patient's dialysis catheter into which 3 ml of Citra-Lock (46.7% trisodium citrate) had been instilled previously as a "catheter locking" solution. The hypernatraemia seen in this case was recognised immediately as an artefact, but it was found that even minimal contamination of blood samples with Citra-Lock may significantly affect sodium concentrations. This contamination may be missed, with potentially adverse consequences for patient management.

Aged↗

Green-coloured results on guaiac-based faecal occult blood testing should be considered positive.

BACKGROUND: In guaiac-based faecal occult blood tests (FOBT), blue colours are considered positive. Blue-green colours should also be considered positive. Distinct green colours are said to be due to bile and it is stated that these should be interpreted as negative. The purpose of this study was to determine the clinical outcomes in individuals in whom the FOBT had difficult-to-interpret green colours that did not wash out on addition of developer. METHODS: During the examination of 134 844 FOBT received in the Scottish laboratory in the first screening round of the UK Colorectal Cancer Screening Pilot, samples with green colour that did not wash out during development were identified. The clinical outcomes were determined from the comprehensive data set collected for each participant. RESULTS: A small number (77) of FOBT were recorded as green-coloured on development. These were reported as positive and the usual investigation algorithm followed. Significant pathology was present in 31 of the 77 participants (40.3%). Negative outcomes encompassed 39 of the 77 participants (50.6%). The outcome could not be determined accurately for seven of the 77 participants (9.1%). Importantly, 17 of the participants (22.1%) had polyps. CONCLUSIONS: Any green colour that does not wash out to the periphery of the guaiac tape on development of FOBT should be reported as a positive result, and manufacturers should clarify their instructions on interpretation.

Colorectal Neoplasms↗

Optimal analytical performance for point of care testing.

Quality specifications for the reliability of performance characteristics of laboratory testing, particularly precision and bias, are necessary prerequisites for creation and control of analytical quality. Many strategies have been promulgated for setting these specifications. Recently, the available approaches have been fixed into a hierarchical framework that has now been accepted by experts in the field to be the best current approach to a global strategy for setting quality specifications in laboratory medicine. They should be incorporated into quality planning strategies everywhere irrespective of the settings in which laboratory medicine is practised, including the point of care testing (POCT). Models higher in the hierarchy are preferred to lower approaches but lower approaches are better than none and should be used as the minimum standard.

Clinical Chemistry Tests↗

Influence of index of individuality on false positives in repeated sampling from healthy individuals.

The index of individuality is defined as the ratio of the within-subject biological variation to the between-subject variation, i.e., the variation between the biological set-points. It has been disputed whether the index of individuality has influence on the usefulness of conventional population-based reference intervals. In this investigation we found that, as long as only a single sample is taken, for a certain change in an individual's set-point, the index of individuality has no influence on the usefulness of reference intervals. When two or more samples are taken into account, however, the outcome of the measurement is highly dependent on the index of individuality. For a low index, repeat measurement has only limited effect on the fraction of false-positive results, as the next result will be close to the first, but, when the index is high, the fraction of false-positive results will be reduced considerably through repeating the test. Moreover, the distribution of biological set-points for which the fraction of false-positive results originate is described and the influence of analytical imprecision is discussed. The calculations are performed for values of the index of individuality from 0 to 2.0 for the traditional 95% reference interval based on x +/- 2*s(total) (s(total) = total biological variation), and also for a decision limit (cut-off point) x +/- 3*s(total). The numbers are, of course, different, but the effects of the index of individuality are the same, independent of the chosen cut-off point. This concept is related to the clinical classification (diagnosis, prognosis, screening) and the difference from different principles of monitoring is discussed. Further, five examples are evaluated and aspects of index of individuality in relation to false-positive results are discussed.

Analysis of Variance↗

A model for setting analytical quality specifications and design of control for measurements on the ordinal scale.

A model for characterization of measurements on the ordinal scale is presented. It is based on transformation of the calculated fractions (fractiles) of positives from measurements on samples with known concentrations to a probit-natural log (probit-ln) scale. Such measurements could be made by other methods on ratio or difference scales but, for convenience (for example for speed or low cost), are measured on the ordinal scale by "simple" methods. The model is examined, and verified, using three examples from published data (haemoglobin, glucose, and leukocytes) and an external quality assessment survey on measurements of streptococcus. We show that it is possible to obtain reliable analytical quality specifications and to establish design of control systems for measurements on the ordinal scale. It is concluded that the presented probit-ln model for the ordinal scale is a tool which can improve and facilitate (i) characterizing methods with measurements on the ordinal scale, (ii) defining analytical quality specifications, (iii) designing external assessment as well as internal control schemes, (iv) validation of methods with measurements on the ordinal scale according to the analytical quality specifications, and further, (v) reduction of the number of samples required for method validation and the number of replicate measurements needed.

Animals↗

General strategies to set quality specifications for reliability performance characteristics.

Many strategies have been promulgated for the setting of quality specifications in laboratory medicine. Based on the analysis of the effect of error on clinical decision making, general quality specifications for precision, bias, the allowable difference between two analytical methods, drugs, fixed limits for use in external quality assessment and reference methods seem best derived from components of biological variation.

Clinical Laboratory Techniques↗

The index of individuality is often a misinterpreted quantity characteristic.

The concept of the "index of individuality" was introduced by Eugene Harris in 1974. The index of individuality, calculated as (CV(A)2 + CV(I)2)(1/2)/CV(G), where CV(A), CV(I), and CV(G) are analytical, within-subject, and between-subject coefficients of variation respectively, has been used by many to investigate the utility of conventional population-based reference values. For a high index of individuality, > 1.4, it has been said that reference intervals will be more useful than for a low index, < 0.6. The validity of these concepts is investigated here and a number of our findings are at odds with the generally held opinion. The index of individuality has no impact on the fraction of individuals classified using population-based reference values, as long as the change in concentration from the usual state is of the same absolute magnitude and one sample is assayed to detect disease. However, when a measurement falling outside a reference limit is repeated in order to verify the finding, the index of individuality has considerable influence. For quantities with very low indices, the repeat test result, will be close to the first and give no new information, whereas for quantities with high indices, a repeat test will decrease the number of true positives and false positives.

Biometry↗

Biological variation of cardiac markers: analytical and clinical considerations.

The analytical, within-subject and between-subject components of variation were estimated for serum total creatine kinase (TCK) activity, CK-MB (creatine kinase-MB) activity, CK-MB mass, ratios of CK-MB activity and CK-MB mass to TCK activity and myoglobin concentration in a cohort of 16 apparently healthy subjects over 5 days. Analytical goals based on biological variation showed that, for all quantities except CK-MB mass, methodological improvement is warranted. All cardiac markers showed marked individuality which casts doubt on the utility of conventional population-based reference values as interpretative criteria. The critical differences required for significance of changes in serial results differ markedly from marker to marker and the data allow generation of objective criteria for monitoring individuals.

Adult↗

The influence of analytical bias on diagnostic misclassifications.

Quality specifications for analytical imprecision and bias based on the state of the art; 'biology' and 'analysis of clinical situations' have been proposed by several scientists. Most interesting is the assessment of 'diagnostic misclassifications' based on direct evaluation of the consequences of analytical bias on the percentage of false positives and false negatives from a clinical decision situation, or based on the percentage of healthy individuals outside each reference limit when common reference intervals are used. With use of graphical or computer simulations assuming increasing (positive or negative) analytical bias, the expected percentage of misclassifications can be estimated- and, for the error for which the outcome (the fraction of misclassifications) is considered unacceptable, the maximum allowable analytical bias can be defined. An overview is given of previous proposals for specification of allowable analytical bias, and new examples are presented: (i) for S-transferrin. an analytical bias of +10% will increase the percentage of healthy individuals with measured concentration values above the upper reference limit from 2.5 to 10% (ii) the percentage of healthy men with concentration values for S-cholesterol above 6.2 mmol/l (240 mg/dl) will vary between 25 and 85% for analytical bias from - 1.0 to +1.0 mmol/l (+/- 16%): (iii) for glycated haemoglobin, two examples are given which illustrate the effect of analytical bias on the risk of retinopathy and so-called 'microalbuminuria' for measured values identical to the target 7.5% and 10.1% glycated haemoglobin, respectively. It is concluded that analytical bias may have significant impact on diagnostic performance, better standardization is needed, and quality specifications for allowable analytical bias should be based on medical usefulness criteria or, if such data are not available, on biological criteria.

Bias↗