PubMed Health⌕ Search

Biomedical subjects

C G Wahlström

Publications and source records attributed to C G Wahlström.

2 recordsLinked to original sources

Contrast-enhanced radiography by differential absorption, using a laser-produced x-ray source.

RATIONALE AND OBJECTIVES: The authors evaluate the feasibility of differential imaging of contrast media, with division of individual pixel values obtained from digital images generated by characteristic radiation from a laser-produced plasma, bridging the K-absorption edge of the contrast agent. METHODS: Laser pulses from an ultrashort-pulse terawatt laser system were focused onto gadolinium and tantalum targets, creating a plasma from which characteristic radiation and Bremsstrahlung was emitted. The elements of the target were selected so the characteristic emission lines of one of the elements were below the K edge of the contrast agent and the emission lines of the other element above. A phantom with gadolinium and other elements in various concentrations was examined. One radiographic exposure was made using a gadolinium target source and a subsequent exposure using a tantalum source. Both images were recorded digitally and the transmission ratios calculated by division of the individual pixel values. RESULTS: When viewed separately, the two images of the test phantom appeared similar. In the differential image, only the gadolinium solutions were bright, reflecting a difference in attenuation between the two exposures. CONCLUSIONS: Element-specific radiographs can be obtained by differential imaging. When fully explored, the technique may allow for contrast-enhanced radiography with increased sensitivity and decreased contrast dose.

Animals↗

Generation of x rays for medical imaging by high-power lasers: preliminary results.

PURPOSE: To evaluate the use of x-ray imaging performed with a high-power laser system in biologic and medical studies. MATERIALS AND METHODS: A compact terawatt laser system based on chirped pulse amplification in titanium-doped sapphire was used. X rays were generated by irradiating a high-atomic-number target (tantalum). RESULTS: When photons with an energy below 10 keV were removed with use of 3 mm of aluminum, the half-value layer in aluminum for the remaining x rays was approximately 10 mm. The x-ray source allowed performance of biologic magnification radiography. Star-pattern tests indicated an equivalent focal spot size of less than 60 microns. Exposures of a single pulse could be obtained. The duration of a single x-ray pulse was estimated to be of the order of picoseconds. CONCLUSION: With use of subpicosecond laser pulses, x-ray generation can occur with a smaller equivalent focal spot size than with conventional x-ray sources.

Aluminum↗