Protein adsorption to the bare silica wall in capillary electrophoresis quantitative study on the chemical composition of the background electrolyte for minimising the phenomenon.

A novel method is reported for quantifying protein adsorption to naked silica tubings and for assessing the efficacy of amino quenchers added to the background electrolyte. It consists of flushing a fluorescently-labelled protein (myoglobin) into a capillary equilibrated in Tris-acetate buffer, pH 5.0, until full saturation of the potential adsorbing sites. Desorption is then affected by driving electrophoretically sodium dodecyl sulphate (SDS) micelles into the capillary from the cathodic reservoir: the peak of eluted material is quantified fluorometrically by using a dual laser beam instrument able to read the fluorescein-isothiocyanate-labelled myoglobin at 520 nm and the internal standard (sulphorodamine) at 630 nm. As potential quenchers, a series of monoamines have been investigated (triethylamine, triethanolamine, ethylamine), followed by diamines (putrescine, cadaverine and hexamethonium bromide) and finally by oligoamines [spermidine, spermine and TEPA (tetraethylenepentamine), i.e., a tri- a tetra- and a pentamine, respectively]. Two values of molarities have been derived: a value at 50% (a kind of a dissociation constant) and a value at 90% inhibition of binding of macromolecules to the silica surface. According to these figures of merit, mono- and diamines are rather poor quenchers of interaction with the wall, since the 50% values are of the order of 50-100 mM and the 90% values reach as high as 560 mM. On the contrary, oligoamines, especially spermine and TEPA, are most effective, since the 50% molarities are in the sub-millimolar range and the 90% values are of the order of ca. 1 mM. Figures of merit have also been derived for different washing procedures. Those most commonly adopted in routine practice, i.e., of washing with either 1 M NaOH or with 1 M HCl, or with both, leave behind traces of proteins still bound to the wall, whereas the SDS micelle electrophoretic desorption seems to be 100% effective.

Adsorption↗

Determination of cow's milk and ripening time in nonbovine cheese by capillary electrophoresis of the ethanol-water protein fraction.

A novel method is reported for analyzing adulteration of goat and ewe cheeses with cow's milk: capillary zone electrophoresis (CZE) in isoelectric, acidic buffers (50 mM imino diacetic acid, IDA, pH = pI 2.3). The cheese samples were extracted with a 20:80 v/v ethanol-water mixture in presence of 3 M urea and 1% beta-mercaptoethanol for 1 h. After centrifugation and lipid extraction, the samples were dissolved in 50 mM IDA, 6 M urea and 0.5% hydroxyethyl cellulose and analyzed by CZE at 700 V/cm. A total of 18 characteristic peaks were resolved among the three types of cheeses and 18 variables were defined as their respective areas. There was excellent similarity among the electrophoretic patterns obtained with cheeses of a given type of milk, while cheeses made with different types of milk were easily distinguishable. Most peaks were common to all cheeses, but the profile differed depending on the type of milk used. Principal component analysis, linear discriminant analysis, and partial least squares regression (PLS) were used for statistical analysis of the data obtained by CZE. In particular, by using PLS multivariate regression, the contents of cow's milk in presumably pure goat and ewe cheeses, as well as in binary and ternary mixtures, could be predicted with relative standard deviations of ca. 6-7%. In addition, the ripening time in goat and ewe cheeses could also be predicted.

Animals↗

Screening for the beta-39 mutation in thalassemia by capillary electrophoresis in free solution in strongly acidic, isoelectric buffers.

A novel method is reported for screening for point mutations in genomic DNA: free-zone capillary electrophoresis in very acidic buffers. This method exploits the charge difference among the four different bases (C, T, A, G) in a pH window between 2.5 and 3.5, where the four titration curves fan out. The method is applied to the detection of the beta-39 missense mutation in the beta-globin gene in thalassemias. A 60-mer fragment straddling the mutation site has been amplified. In an isoelectric buffer (iminodiacetic acid) of pH 3.3, partial resolution between the wild type and mutated strands is obtained. In a pH 3.0 phosphate buffer, baseline resolution is achieved between the two strands in a heterozygous individual. Due to the short size of the amplified fragment, this method can only be applied to routine screening for known mutations because resolution was lost in a fragment 100 bases long.

Buffers↗

Single-strand conformation polymorphism analysis by capillary zone electrophoresis in neutral pH buffer.

Sensitivity of single-strand conformation polymorphism (SSCP) analysis of polymerase chain reaction (PCR) products was reported to be lower in capillary zone electrophoresis (CZE) compared to conventional slab gel electrophoresis. We examined the effects of buffer ion type, pH, and temperature in an attempt to improve the mutation detectability in the SSCP-CZE mode. It was noted that, by utilizing short-chain polyacrylamide as sieving media while simultaneously lowering the temperature, there was no improvement of conformer detectability. On the contrary, there was a large increment in conformers' resolution by running samples in a lower-pH buffer system. The effects of different buffering ions and pH values were investigated. By using a new buffer system, consisting of 35 mM 2-(N-morpholino)propanesulfonic acid (MES), 30 mM tris(hydroxymethyl)aminomethane (Tris), 1 mM ethylene diaminetetraacetic acid (EDTA), pH 6.8, and keeping constant all the other conditions, such as temperature, sieving, applied voltage, capillary length, and inner diameter (ID), there was a remarkable improvement in resolution and the sensitivity became comparable to that of slab gel systems.

Buffers↗

DNA and buffers: the hidden danger of complex formation.

The free solution electrophoretic mobility of DNA differs significantly in different buffers, suggesting that DNA-buffer interactions are present in certain buffer systems. Here, capillary and gel electrophoresis data are combined to show that the Tris ions in Tris-acetate-EDTA (TAE) buffers are associated with the DNA helix to approximately the same extent as sodium ions. The borate ions in Tris-borate-EDTA (TBE) buffers interact with DNA to form highly charged DNA-borate complexes, which are stable both in free solution and in polyacrylamide gels. DNA-borate complexes are not observed in agarose gels, because of the competition of the agarose gel fibers for the borate residues. The resulting agarose-borate complexes increase the negative charge of the agarose gel fibers, leading to an increased electroendosmotic flow of the solvent in agarose-TBE gels. The combined results indicate that the buffers in which DNA is studied cannot automatically be assumed to be innocuous.

Acetates↗

Capillary electrophoresis of peptides and proteins in isoelectric buffers: an update.

Capillary electrophoresis in acidic, isoelectric buffers is a novel methodology allowing fast protein and peptide analysis in uncoated capillaries. Due to the low pH adopted and to the use of dynamic coating with cellulose derivatives, silanol ionization is essentially suppressed and little interaction of macromolecules with the untreated wall occurs. In addition, due to the low conductivity of quasi-stationary, isoelectric buffers, high-voltage gradients can be applied (up to 800 V/cm) permitting fast peptide analysis with a high resolving power due to minimal diffusional peak spreading. Four such buffers are here described: cysteic acid (Cys-A, pI 1.85), iminodiacetic acid (IDA, pI 2.23), aspartic acid (Asp, pI 2.77) and glutamic acid (Glu, pI 3.22). A number of applications are reported, ranging from food analysis to the study of folding/unfolding transitions of proteins.

Animals↗

Capillary electrophoresis of DNA in the 20-500 bp range: recent developments.

The present mini-review summarizes recent developments in the field of DNA separations by capillary zone electrophoresis (CZE), as developed by our group. Separation of antisense oligonucleotides in sieving liquid polymers in isoelectric buffers is first discussed. It is shown that the use of isoelectric buffers (notably His) permits very high voltage gradients (up to 1,000 V/cm) with much reduced transit times and increased resolution of all truncated and failed sequences. Oligonucleotides can also be analyzed by zone electrophoresis against a stationary pH gradient (typically a pH 6.5-10 range): if injected at the alkaline end, the sample components experience stacking and zone sharpening due to modulation of charge as the oligonucleotides move along the pH gradient. Oligonucleotides having the same length, but differing by one single nucleotide in the chain, can be separated in free solution (i.e., in the absence of a sieving matrix) at strongly acidic pH values (pH 3.0-3.3) where charge differences due to base protonation are maximized. By working in free solution, it has also been possible to measure accurately the free mobility of DNAs, shown to reach a constant value of 3.75+/-0.04 10(-4) cm2 V(-1) s(-1) at 25 degrees C and in Tris-acetate-EDTA buffer, pH 8.3, above a critical length of ca. 400 bp. However, when double-stranded, rather than single-stranded, DNA is analyzed in isoelectric His buffer, some peculiar phenomena are observed: improved resolution for smaller DNA fragments (up to ca. 150 bp) and a rapid deterioration of resolution above this critical length. Direct binding of His to the DNA helix is hypothesized, via a bidentate salt bridge of the two charged amino groups of His on the negatively charged oxygen of the phosphate group. Upon extensive binding, occupying every available phosphate site, pi-pi interactions could occur among the stacks of bound His residues, thus further stabilizing the complex.

Buffers↗

Separation of double-stranded DNA in conventional and isoelectric buffers: studies on stability and separation performance.

In the capillary electrophoresis of double-stranded DNA in isoelectric buffers, worsening of resolution was observed in electropherograms as a function of time passed from the preparation of the separation solution, which consisted of 0.7% hydroxypropylcellulose, HPC, Mr 10(6), diluted in 150 mM histidine buffer. The DNA standards used were: kilobase pair-ladder, Marker V and Marker VI. In order to understand what happens in the histidine-HPC solution with ageing, the absorbance spectrum (200-500 nm), the conductivity and the pH of the solutions as a function of time were monitored. Fresh His gave a distinct peak at 206 nm. For all the solutions a significant diminution in the maximum absorbance value at 206 nm was observed as a function of ageing, with the concomitant appearance of a peak at 278 nm as the solutions became older. Also the conductivity increases dramatically with the ageing of the solutions and seemed to reach a plateau after ca. 40 days. In concomitance with the conductivity increments with time, the pH of the His solution (isoelectric point, pI=7.6) grew slowly up to pH 7.9; these combined data indicated that a new species contributing to the conductivity and altering the pH was formed from the His molecule, suggesting that His degraded in time. When the dipeptide His-Gly was used instead, a similar ageing phenomenon was observed, but with much reduced kinetics. Mass spectrometry, coupled to RP-HPLC, detected, in aged His solutions, in addition to intact His, two main degradation products: a 110.1 u species and a 93.2 u compound. The mass of the former coincides with the protonated species derived from the formation of a Schiff base on the alpha-amino group of His and subsequent decarboxylation without transformation of the final Schiff base into a chetonic group (a histamine-like molecule terminating with an imino, rather than with an amino group).

Buffers↗

General experimental aspects of the use of isoelectric buffers in capillary electrophoresis.

Four acidic, isoelectric buffers, for peptide and protein separations, have been recently described and adopted in capillary zone electrophoresis: cysteic acid [Cys-A, isoelectric point (pI) 1.85], iminodiacetic acid (IDA, pI 2.23), aspartic acid (Asp, pI 2.77) and glutamic acid (Glu, pI 3.22). These four buffers allow to explore an acidic portion of the titration curves of macroions, covering about 1.6 pH units (from pH 1.85 to ca. 3.45), thus permitting resolution of compounds having coincident titration curves at a given pH value. Given the rather acidic pI values of these buffers, their long-term stability has been investigated, by monitoring pH and conductivity changes upon increasing storage times. When dissolved in plain water, all four buffers appear to give constant pH and conductivity readings up to 15 days; after that, the conductivity keeps steadily increasing in a similar fashion. The same parameters, when the same buffers are dissolved in 6 M urea, appear to be stable for only one week, with the conductivity progressively augmenting after this period. A similar behaviour is exhibited by histidine (pI 7.70), a neutral, isoelectric buffer adopted for separation of DNA fragments. By mass spectrometry, Cys-A shows minute amounts (ca. 1%) of a degradation product after ageing for 3 weeks; in the same time period, Glu is extensively degraded (20%). No degradation species could be detected in IDA and Asp solutions. It is additionally shown that the acidic buffers are not quite stationary in the electric field, but can be transported at progressively higher rates (according to the pI value) from the cathodic to the anodic vessel. This is due to the fact that, at their respective pI values, a fraction of the amphotere has to be negatively charged in order to provide counterions to the excess of protons due to bulk water dissociation. Guidelines are given for the proper use and storage of such buffers.

Buffers↗

Capillary electrophoresis of peptides and proteins in acidic, isoelectric buffers: recent developments.

The use of isoelectric buffers in capillary zone electrophoresis is here reviewed. Such buffers allow delivery of very high voltage gradients (up to 1000 V/cm in relatively large bore capillaries, e.g. 75-100 microm I.D.), permitting separations of the order of a few minutes and thus conserving (in fact favouring) very high resolution due to minimal, diffusion-driven, peak spreading. Isoelectric Asp (pI 2.77 at 50 mM concentration and 25 degrees C) provides a medium of high resolving power for generating peptide maps. In difficult cases, of coincident titration curves, the pH can be moved up to higher values (e.g. pH 3.0 for 30 mM Asp) thus eliciting separation of unresolved peptides at pH 2.77. This was illustrated by running peptide maps of tryptic digests of human beta globin chains. Also imino diacetic acid (pI 2.33 at 50 mM concentration) allows generation of high resolution peptide maps. Isoelectric Asp, in presence of 7 M urea and 0.5% hydroxyethyl cellulose (Mn = 27 000 Da) is also the preferred medium for fast separation and analysis of storage proteins in cereals, such as gliadins in soft and durum wheat and zeins in maize. A solution of 50 mM iminodiacetic acid (pI 2.23) containing 7 M urea and 0.5% hydroxyethylcellulose (apparent pH 3.2) is effectively used as background electrolyte for fast separation of heme-free, denatured globin (alpha and beta) chains. In the presence of neutral to neutral amino acid substitutions, it is additionally shown that the inclusion of 3% surfactant (Tween 20) in the sample and background electrolyte induces the separation of the wild-type and mutant chains, probably by a mechanism of hydrophobic interaction of the more hydrophobic mutant with the detergent micelle, via a mechanism similar to 'micellar electrokinetic chromatography'.

Animals↗

Genetic heterogeneity in Italian families with familial hemiplegic migraine.

OBJECTIVE: To verify linkage to chromosome 19p13, to detect mutations in the CACNA1A gene, and to correlate genetic results to their clinical phenotypes in Italian families with familial hemiplegic migraine (FHM). BACKGROUND: FHM is an autosomal dominant disease, classified as a subtype of migraine with aura. Only a proportion of FHM patients have been associated with chromosome 19p13. Among these, four missense mutations within the CACNA1A gene in five unrelated families have been described. METHODS: A linkage study was performed in 19 patients affected by FHM from five families by studying microsatellite markers associated with the 19p13 region. All familial and seven additional sporadic patients with FHM were analyzed to search for mutations within the CACNA1A gene by applying the double gradient-denaturant gradient electrophoresis technique. RESULTS: Lod score values did not establish significantly linkage to chromosome 19. However, seven new genetic variants were detected: six were new polymorphisms. The seventh was a missense mutation present in family 1, and it was associated with a hemiplegic migraine phenotype without unconsciousness and cerebellar ataxia. Because this missense mutation is absent in the general population and cosegregates with the disease, it may be a pathologic mutation. CONCLUSIONS: Genetic heterogeneity of FHM has been shown in familial and sporadic FHM patients of Italian origin. The new missense mutation-G4644T-is associated with milder clinical features compared with typical FHM.

Adolescent↗

A new CACNA1A gene mutation in acetazolamide-responsive familial hemiplegic migraine and ataxia.

OBJECTIVE: To search for mutations in the calcium channel gene CACNA1A and to study the genotype-phenotype correlation in a family with a severe familial hemiplegic migraine (FHM) phenotype and a slowly progressive cerebellar ataxia. BACKGROUND: CACNA1A gene mutations on chromosome 19 are involved in approximately 50% of FHM families. The association of FHM and cerebellar ataxia has been reported in a small number of FHM families, all linked to chromosome 19. METHODS: The proband, in addition to typical hemiplegic migraine attacks, experienced severe episodes during which hemiplegia was associated with acutely altered consciousness and fever lasting several days. She, as well as her affected sister, developed a permanent, late-onset cerebellar ataxia and cerebellar atrophy evident on MRI. Linkage analysis was performed and the whole CACNA1A gene, 47 exon-intron boundaries, was analyzed by double gradient-denaturing gradient gel electrophoresis (DG-DGGE). RESULTS: Genetic studies suggested linkage to chromosome 19p13, and DG-DGGE analysis detected a heteroduplex fragment in exon 13 of the CACNA1A gene. By direct sequencing, a G-to-A substitution resulting in an arginine to glutamine change at codon 583 in the second putative voltage sensor domain of the channel alpha1A-subunit, was identified, possibly representing the disease-causing mutation. The proband and her affected sister were treated with acetazolamide, reporting freedom from new FHM attacks but no benefit in the progression of ataxia. CONCLUSIONS: The combination of episodic dysfunction and permanent deficit could depend on the variety of functions of calcium channels and their distribution in the nervous system.

Acetazolamide↗

Protein folding observed by capillary electrophoresis in isoelectric buffers.

Capillary zone electrophoresis measurements in acidic isoelectric buffers provide a sensitive and rapid method for comparison of the folding and stability of wild type, mutant or post-translationally modified proteins. The potential of the method is illustrated using the small globular protein cytochrome c.

Buffers↗

DNA-histidine complex formation in isoelectric histidine buffers.

The free solution electrophoretic mobility of two DNA molecules of different molecular masses, 18 base pairs and 2686 base pairs, has been measured in isoelectric histidine buffers with and without added low-molecular-mass electrolytes. Extensive DNA-histidine complex formation is observed in isoelectric histidine buffer, as evidenced by distortion and splitting of the peaks in the electropherograms. Peak distortion and splitting can be decreased or eliminated by adding low-molecular-mass neutral salts to the solution, suggesting that the DNA-histidine complexes are stabilized by electrostatic interactions. The ability of various neutral salts to disrupt the DNA-histidine complexes depends on the molecular mass of the DNA and the concentration and type of added salt.

Anions↗

Detection of neutral and charged mutations in alpha- and beta-human globin chains by capillary zone electrophoresis in isoelectric, acidic buffers.

A simple and reliable method, for screening for point mutations in alpha- and beta-human globin chains, is reported here, utilizing capillary zone electrophoresis in isoelectric, acidic buffers. A solution of 50 mM iminodiacetic acid (pI 2.23) containing 7 M urea and 0.5% hydroxyethylcellulose (apparent pH 3.2) is used as background electrolyte for fast separation of heme-free, denatured globin (alpha and beta) chains. Due to the low conductivity of such buffers, high voltage gradients (600 V/cm) can be applied, thus reducing the separation time to only a few minutes. In presence of neutral to neutral amino acid substitutions, it is additionally shown that the inclusion of 3% surfactant (Tween 20) in the sample and background electrolyte induces the separation of the wild-type and mutant chains, probably by a mechanism of hydrophobic interaction of the more hydrophobic mutant with the detergent micelle, via a mechanism similar to "micellar electrokinetic chromatography". At this low operative pH, however, charged mutants, involving substitutions of acidic amino acids (Glu and Asp) are not detected, since these residues are extensively protonated. Curiously, however, they are still separated in presence of detergent, due to the large variation in hydrophobicity involved in such mutations. Of the 19 mutants analyzed, all but one were resolved: Hb St Nazaire (beta 103 Phe-->Ile). This is due to the fact that the delta G (in kcal/mol) in the substitution Phe-->Ile is zero, thus no separation can possibly take place between two chains exhibiting the same hydrophobicity parameter.

Buffers↗

Validation of double gradient denaturing gradient gel electrophoresis through multigenic retrospective analysis.

Among established techniques for the identification of either known or new mutations, denaturing gradient gel electrophoresis (DGGE) is one of the most effective. However, conventional DGGE is affected by major drawbacks that limit its routine application: the different denaturant gradient ranges and migration times required for different DNA fragments. We developed a modified version of DGGE for high-throughput mutational analysis, double gradient DGGE (DG-DGGE), by superimposing a porous gradient over the denaturant gradient, which maintains the zone-sharpening effect even during lengthy analyses. Because of this innovation, DG-DGGE achieves the double goals of retaining full effectiveness in the detection of mutations while allowing identical run time conditions for all fragments analyzed. Here we use retrospective analysis of a large number of well-characterized mutations and polymorphisms, spanning all predicted melting domains and the whole genomic sequence of three different genes--the cystic fibrosis transmembrane conductance regulator (CFTR), the beta-globin, and the p53 genes--to demonstrate that DG-DGGE may be applied to the rapid scanning of any sequence variation.

Cystic Fibrosis Transmembrane Conductance Regulato↗

Analysis of clinically relevant, diagnostic DNA by capillary zone and double-gradient gel slab electrophoresis.

A number of applications of capillary zone electrophoresis (CZE) in sieving liquid polymers (notably linear polyacrylamides and cellulose) for the analysis of polymerase chain reaction products of clinically relevant, diagnostic DNA, are reviewed here. The fields covered are human genetics, quantitative gene dosage, microbiology and virology, forensic medicine and therapeutic DNA (notably antisense nucleotides). Some unique, novel developments are highlighted, such as (a) non-isocratic CZE, i.e., temperature-programmed CZE for detection of DNA point mutations and (b) the synthesis of novel N-substituted acrylamides, offering extreme resistance to alkaline hydrolysis, coupled with high hydrophilicity. In the field of denaturing gradient gel electrophoresis (DGGE), as routinely performed in gel slabs, a novel methodology is described, i.e., double-gradient DGGE. In this technique, two gradients are simultaneously applied along the migration direction; a chemical denaturing gradient, for partially unwinding homo- and hetero-duplexes of DNA and a porosity gradient, for re-compacting diffuse bands melting over a broader range of denaturing conditions. Both the CZE and the slab gel methodologies, with the latest developments described in this review, appear to be promising tools for screening diagnostic DNA.

DNA↗

Recent advances in capillary zone electrophoresis of DNA.

The present minireview summarizes recent developments in the field of DNA separations by capillary zone electrophoresis (CZE), as developed by our group. Separation of antisense oligonucleotides in sieving liquid polymers in isoelectric buffers is discussed first. It is shown that the use of isoelectric buffers permits very high voltage gradients (up to 1000 V cm-1) with much reduced transit times and increased resolution of all truncated and failed sequences. Oligonucleotides can also be analysed by zone electrophoresis against a stationary pH gradient (typically a pH 6.5-10 range): if injected at the alkaline end, the sample components experience stacking and zone sharpening due to modulation of charge as the oligonucleotides move along the pH gradient. Oligonucleotides having the same length, but differing by one single nucleotide in the chain, can be separated in free solution (i.e. in the absence of a sieving matrix) at strongly acidic pH values (pH 3.0-3.3) where charge differences due to base protonation are maximized. By working in free solution, it has also been possible to measure accurately the free mobility of DNAs, shown to reach a constant value of 3.75 +/- 0.04 10(-4) cm2 V-1 s-1 at 25 degrees C and in Tris-acetate-EDTA buffer, pH 8.3, above a critical length of ca. 400 base pairs. Finally, detection of point mutations in human genomic DNA is proven to be feasible in nonisocratic CZE, by running temperature-programmed CZE. The temperature gradient is activated within the capillary lumen by voltage ramps during the run, by exploiting joule effects. This technique has been proven to work for all point mutants, from low-, to intermediate-, to high-melters and has been applied to a number of point mutants in cystic fibrosis and thalassemia.

Buffers↗