AEC set-up optimisation with computed radiography imaging.

Phototimer set-up is a critical procedure for dose and image quality optimisation in computed radiography (CR) systems. While a conventional radiography automatic exposure control device (AEC) can be calibrated in order to gain a constant optical density on the film independent of beam quality and patient size, CR detectors present a high dynamic range which allows a much larger dose interval, but with different image quality levels. CR leads to a less frequent exam repetition, but may produce quite noisy images if the exposure level on the plate is not correct. The aim of this work is to evaluate the performance of a CR plate (Agfa MD40) in order to optimally calibrate an AEC device. The plate response has been characterised in terms of digital signal, exposure on the plate and signal-to-noise ratio for different beam qualities, in a patient of standard size.

Calibration↗

Temporal change in the use of genotypic resistance testing over the years 1999--2003.

The evaluation of resistance test perception by clinicians over the years 1999--2003 was assessed in an Italian cohort. The results on 2233 samples from 1416 HIV-1 infected patients show an increase in HIV-1 drug resistance test requests over time, with a plateau reached in the last three years. CD4-cell count at the time of genotype request progressively increased. In particular, the median CD4 cell count of drug-treated patients increased from 221x10(6) cells/l [interquartile range (IQR): 109-368] in 1999 to 296x10(6) cells/l (IQR: 166-478) in 2003 (p<0.0001). At the same time, plasma HIV-RNA level progressively decreased from a median of 103,500 copies/ml (IQR: 37,250-260,000) in 1999 to 9,444 copies/ml (IQR: 2,086-41,281) in 2003 (p<0.0001). Overall, data suggest that the genotype test is increasingly considered, and requested also for patients at earlier stages of drug history and/or at less severe disease stage.

Anti-HIV Agents↗

Use of TLD in evaluating diagnostic reference levels for some radiological examinations.

The European Council Directive 97/43 introduces diagnostic reference levels (DRL) for all medical examinations involving ionising radiation. Each department has to evaluate patient dose and to compare that value with the DRL adopted by its member state. Italian law, applying the Directive, states that reference levels must be measured every 2 years. Quantities that must be measured are entrance surface dose or air kerma, or other dosimetric quantities. In our work, clinical measurements on patients were made by positioning a thermoluminescence dosemeter (TLD) over the skin of a statistically significant number of patients for each projection of each examination. As there is no national guideline for these measurements in Italy, the aim of this work was to establish a method based both on European publications and on clinical experience. Three different modalities were considered: conventional radiography, computed radiography and mammography. Accordingly, differently shaped types of TLD were required, especially for mammography where the beam energy is lower.

Automation↗

Chronic axonal sensory and autonomic polyneuropathy without motor involvement: a new 'chronic inflammatory neuropathy?'.

We report the case of a woman with axonal sensory and autonomic neuropathy lasting several months who improved in association with steroid administration. During the course of her disease and in the follow-up, the patient underwent repeated cerebrospinal fluid (CSF) examinations, neurophysiological somatic, autonomic nervous system studies and sural nerve biopsy. Clinical and laboratory assessments demonstrated the occurrence of a monophasic, chronic sensory and autonomic neuropathy. A sural nerve biopsy suggested an axonopathy. After a progressive worsening of symptoms lasting about 6 months, steroid treatment was started and within 6 months a complete recovery, with normalization of the CSF findings, was observed. Although the 'chronic inflammatory neuropathies' are still debated entities, the features of this chronic, exclusively sensory and autonomic neuropathy are new, and the occurrence of a high protein level in the CSF, together with the favorable outcome associated with steroid treatment, suggests that our case might be another variant in this debated area.

Autonomic Nervous System Diseases↗

Decreased spontaneous heart rate variability in congestive heart failure.

Heart rate (HR) variability is a noninvasive index of the neural activity of the heart. Although also dependent on the sympathetic activity of the heart, HR variability is mainly determined by the vagal outflow of the heart. Several HR abnormalities have been described in patients with congestive heart failure (CHF); however, there are no data on HR variability in CHF patients. In the present study HR variability was assessed in 20 CHF patients and 20 control subjects from 24-hour Holter tapes. HR variability was evaluated by calculating the mean hourly HR standard deviation and by analyzing the 24-hour RR histogram. Mean hourly HR standard deviation was markedly and significantly reduced in CHF patients both over the 24-hour period (97.5 +/- 41 vs 233.2 +/- 26 ms, p less than 0.001) as well as during most of the individual hours examined. The 24-hour RR histogram of CHF patients had a different shape and had a decreased variation compared to control subjects (total variability 356 +/- 102 vs 757 +/- 156 ms, p less than 0.001). Thus, CHF patients with depressed ejection fraction (less than 30%) have a low HR variability compared to normal individuals. This result can be interpreted as adjunctive evidence for decreased parasympathetic activity to the heart during CHF.

Adult↗

Possible sources of error in the calculation of ferrokinetic parameters using Ricketts' triexponential model.

The triexponential model developed by Ricketts et al. in 1975 for the calculation of ferrokinetic parameters has been widely used to obtain quantitative information about effective and ineffective erythropoiesis. However, a calculation error in one of the formulae of this method may have a considerable effect on those results which depend on the value of the third exponential constant, gamma 3. Moreover, the analysis of plasma 59Fe activity needs to be based on good counting statistics, which lambda-counting seldom provides after the first 24 h; therefore, 59Fe beta-counting is considered to be the best method.

Anemia↗