Interactions between electromagnetic fields and biological systems.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C H Durney.
Explore the source record for details and available documents.
Observations recently reported by others indicate that a combination of a weak dc magnetic field and extremely-low-frequency ac magnetic field can produce resonant effects in biological systems. We report measurements of the effects of combined dc and ac magnetic fields on the dc current through channel-free planar phospholipid membranes. The combined dc-ac magnetic fields did affect the dc current through planar phospholipid membranes, but not in every membrane, and not consistently at the same values of magnetic flux density and frequency. None of our measurements showed resonant response akin to the cyclotron-like resonance reported in diatoms [Smith et al., 1987] and lymphocytes [Liboff et al., 1987].
The possibility that weak, ac and dc magnetic fields in combination may affect binding equilibria of calcium-ions (Ca2+) was investigated with two metallochromic dyes as calcium-binding molecules: murexide and arsenazo III. Calcium-dye equilibria were followed by measuring solution absorbances with a fiber-optic spectrophotometer. A Ca(2+)-arsenazo solution was also used indirectly to monitor the binding of Ca2+ to calmodulin. Parallel, ac and dc magnetic fields were applied to each preparation. The ac magnetic field was held constant during each of a series of experiments at a frequency in the range between 50 and 120 Hz (sine wave) or at 50 pps (square wave) and at an rms flux density in the range between 65 and 156 microT. The dc magnetic field was then varied from 0 to 299 microT at 1.3 microT increments. The magnetic fields did not measurably affect equilibria in the binding of metallochromic dyes or calmodulin to Ca2+.
We compared in vivo and in vitro Hahn echo T2 measurements in rat lungs in both imaging and nonimaging modes. All measurements could be characterized by multiexponential functions consisting of either two or three exponentials. Essentially the same values of the time constants were observed for spontaneously breathing rats and for excised lungs.
In analytical studies, we investigated induced-field patterns and SAR distributions in a lossy, dispersive, homogeneous, dielectric sphere typical of muscle tissue as irradiated by a plane-wave pulse train consisting of a pulse-modulated sinusoidal carrier wave. Calculations were made for carrier frequencies of 1, 3, and 15 GHz, pulse widths of 0.333, 2.0 and 4 ns, and pulse repetition rates of 1.11 x 10(6), 100 x 10(6), and 181.18 x 10(6) pps. The classical Mie solution was modified for a train of incident pulses that was represented by a Fourier series, and the fast-Fourier transform was used to sum the series. Computationally, the technique proved to be feasible and less expensive than we expected. The calculated field patterns show that the sphere's physical dimensions and the internal wavelength of the carrier greatly influence the nature of pulse-train propagation in the sphere. Harmonics having internal wavelengths nearly equal to the radius of the sphere produce most of the absorption; other harmonics produce little absorption. An intense hot spot is observed in spheres with radii that match the carriers' wavelengths.
A hyperthermia applicator design tool consisting of a finite-difference time-domain (FDTD) technique in combination with a graphical display of electric fields and normalized linear temperature rise is described. This technique calculates, rather than assumes, antenna current distributions; it includes mutual interactions between the body and the applicator, and it calculates driving-point impedance and power delivered to the applicator. Results show that the fundamental limitation of 2-D electric-type applicators is overheating of the fat by normal components of the electric field, which exist because of near fields and capacitive coupling with the muscle. Two factors which contribute to the capacitance are the muscle conductivity and the small antenna size in air. Two examples of applicators designed to avoid fat overheating are described: a 27-MHz segmented dipole for heating large tumors to 7 cm depth, and a 100-MHz dipole for small tumors to 5 cm depth. The first uses a water bolus, and the second uses a water bolus with low-permittivity strips to reduce normal fields at the antenna ends. The results of this study describe fundamental limitations of electric field applicators, and illustrate the use of a powerful applicator design tool that allows rapid evaluation of a wide range of ideas for applicators which would require months and years to test experimentally.
Inflated lungs are characterized by a short nuclear magnetic resonance (NMR) free induction decay (rapid disappearance of NMR signal), likely due to internal (tissue-induced) magnetic field inhomogeneity produced by the alveolar air-tissue interface. This phenomenon can also be detected using temporally symmetric and asymmetric NMR spin-echo sequences; these sequences generate a pair of NMR images from which a difference signal (delta) is obtained (reflecting the signal from lung water experiencing the air-tissue interface effect). We measured delta in normal excised rat lungs at inflation pressures of 0-30 cmH2O for asymmetry times (a) of 1-6 ms. Delta was low in degassed lungs and increased markedly with alveolar opening when measured at a = 6 ms (delta 6 ms); delta 6 ms varied little during the rest of the inflation-deflation cycle. Delta 1 ms (a = 1 ms) did not vary significantly on inflation and deflation. Measurements of delta at a = 3 and 5 ms generally lay between those of delta 1 ms and delta 6 ms. These findings, which are consistent with theoretical predictions, suggest that measurements of delta at appropriate asymmetry times are particularly sensitive to alveolar opening and may provide a means of distinguishing alveolar recruitment from alveolar distension in the pressure-volume behavior of the lung.
The responses of a plane-wave pulse train irradiating a lossy dispersive dielectric half-space are investigated. The incident pulse train is expressed as a Fourier series with summing done by the inverse fast Fourier transform. The Fourier series technique is adopted to avoid the many difficulties often encountered in finding the inverse Fourier transform when transform analyses are used. Calculations are made for propagation in pure water, and typical waveforms inside the dielectric half-space are presented. Higher harmonics are strongly attenuated, resulting in a single continuous sinusoidal waveform at the frequency of the fundamental depth in the material. The time-averaged specific absorption rate (SAR) for pulse-train propagation is shown to be the sum of the time-averaged SARs of the individual harmonic components of the pulse train. For the same average power, calculated SARs reveal that pulse trains generally penetrate deeper than carrier-frequency continuous waves but not deeper than continuous waves at frequencies approaching the fundamental of the pulse train. The effects of rise time on the propagating pulse train in the dielectrics are shown and explained. Since most practical pulsed systems are very limited in bandwidth, no pronounced differences between their response and continuous wave (CW) response would be expected. Typical results for pulse-train propagation in arrays of dispersive planar dielectric slabs are presented. Expressing the pulse train as a Fourier series provides a practical way of interpreting the dispersion characteristics from the spectral point of view.
It is well known that pulmonary edema is, in general, spatially nonuniform. Since the NMR spin-lattice relaxation time (T1) is increased by lung edema, the spatial distribution of T1 will be nonuniform. When the repetition time (TR) is short relative to the T1 of edematous lung, lung water content will be underestimated and this underestimation will be spatially nonuniform as well. Therefore, technical artifacts which are a complex function of lung edema and its spatial distribution are expected. We compared overall and regional (topographic) lung water density measurements obtained from living rats (with normal or edematous lungs) using repetition times of 2.0 and 6.2 s (at a magnetic field of 1 T), to quantify this uneven T1 effect for normal and edematous lungs. NMR measurements at TR = 2.0 s underestimated whole lung water density (-rho H2O) TR = 6.2 s) by an average of 7.2% in normal rats and 22.5% in rats with pulmonary edema. Regional -rho H2O underestimation (%delta-rho H2O) varied from 2.2 to 8.8% (groups means) in normal lungs and from 7.3 to 30.8% in edematous lungs. As a result, the interquartile range (of the voxel distribution as a function of rho H2O) underestimated the spatial nonuniformity of lung water density by 28.0% in edematous lungs, likely because of greater loss of NMR signal from high-water-density, long-T1 lung regions. Both %delta-rho H2O and T1 were significantly correlated with -rho H2O at TR = 6.2 s.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
An elementary model consisting of one charged particle in a viscous medium exposed to weak ac-dc low-frequency magnetic fields is analyzed to identify and explain the fundamental characteristics of the physical mechanisms that result in a resonance response, which is similar to the familiar cyclotron resonance. The model predicts both frequency and amplitude windows, which are explained in terms of synchronization of the particle with electric fields. Although extrapolation of model results to biological systems is limited by the elementary nature of the model, the model results indicate that observed resonant responses by others of biological systems to ac-dc magnetic fields are probably not due to resonant response of ions in solution, since the model predicts that no resonant response is possible unless the viscous damping is very low, many orders of magnitude lower than the viscous damping of ions in solution.
Considerable progress has been made in the application of nuclear magnetic resonance (NMR) imaging and nonimaging techniques to the quantitative assessment of pulmonary edema. NMR measurements offer the advantages of being noninvasive, relatively rapid, and easily repeatable. In addition, NMR imaging is suitable for the determination of lung water distribution. Studies of various animal models have shown that NMR techniques can adequately detect and quantify relative changes in lung water content and distribution in various types of experimental lung injury. Preliminary observations in humans suggest that NMR measurement of relative lung water changes in clinical pulmonary edema should be feasible. Although the application of NMR to the assessment of pulmonary edema appears to be very promising, it also poses significant problems that must be solved before it can be established as a standard experimental and clinical method.
We have developed a new analytical method that uses nuclear magnetic resonance (NMR) imaging data to quantify lung water content and distribution. This new method generates a distribution of lung water density in which the fraction of voxels corresponding to a given water density is plotted on the vertical axis as a function of water density on the horizontal axis, thereby complementing the spatial information provided by the NMR image. We obtained reproducible lung water distribution data at comparable lung volumes in normal excised lungs and in intact living rats. In normal excised unperfused rat lungs, the distribution varied with the degree of inflation, but the changes were small compared with those associated with lung edema. The lung water density distribution changed markedly after induction of lung edema by intrabronchial saline instillation, intravenous oleic acid injection, and rapid intravenous saline infusion. Lung water density distribution data were well correlated (correlation coefficient = 0.948 for the excised lungs and 0.823 for the intact living rats) with gravimetric lung water measurements. The new analytical method is noninvasive, provides easily repeatable measurements, and is as sensitive as the gravimetric technique to lung water changes.
NMR imaging techniques are applicable to the assessment of lung water content and distribution because the NMR signal is, under certain conditions, proportional to tissue proton density. NMR imaging is noninvasive, easily repeatable, free from ionizing radiation, and particularly suitable for the assessment of spatial lung water distribution. Lung water content and distribution have been estimated in excised animal lungs and in intact dead or living animals, under normal conditions and in various types of experimental pulmonary edema. Excised human lungs and human subjects have also been studied. Published data indicate that measurements of lung water content by NMR imaging techniques are feasible. These techniques estimate lung water spatial distribution with satisfactory accuracy and excellent resolving power. The application of NMR imaging techniques poses several problems and limitations, but available data suggest that most of the problems can be solved. NMR imaging has the potential to become a powerful tool for lung water research. Prospects of clinical application are also encouraging; numerous applications can be foreseen, although lack of mobility of NMR imaging systems may be a significant limitation in critical care medicine.
Inflated lung has a nuclear magnetic resonance (NMR) free-induction decay (FID) which is short compared with that of collapsed lung and those of other body tissues. An almost identically short FID is obtained from a slurry of 5-micron alumina particles in water. Interfaces between air and water in lung and between alumina and water in the slurry appear to be the source of spatial internal magnetic inhomogeneities which produce NMR line broadening and the short FID. Paired images that included lung, taken with paired symmetric and asymmetric NMR spin-echo sequences, permit the generation of an image, by subtraction, of the lung isolated from surrounding tissue. These new lung images are neither proton density, T1 (spin-lattice relaxation time), nor T2 (spin-spin relaxation time) images. They complement current NMR images and provide information about regional lung inflation. This previously unrecognized NMR property of lung tissue has potential application in NMR imaging, in quantitative determination of lung water and its distribution, and in the quantitation of regional lung inflation.
Long-Evans male adult rats were exposed for sixteen weeks to 2450-MHz CW microwaves at an average power density of mW/cm2. The resulting dose rate was 1.23 (+/- 0.25SEM) mW/g. The animals were exposed eight hours a day, five days a week, for a total of 640 h in a monopole-above-ground radiation chamber while housed in Plexiglas holding cages. Daily measures of body mass and of food and water intakes indicated no statistically significant effects of microwave irradiation. Biweekly stabilimetric tests immediately after exposure revealed a significant depression of behavioral activity by 15 microwave-exposed rats as compared with 15 sham-exposed animals. Measures of locomotor activity based on revolutions of a running wheel, which were obtained during 12-h periods between each 8-h exposure, showed no significant effect of irradiation. Blood sampled after 2, 6, 10, and 14 weeks of exposure indicated slight alterations of sulfhydryl groups, and of red and white blood-cell counts. Measures of levels of 17-ketosteroids in urine at weeks 1, 5, 9, and 12 of exposure, and mass of adrenals, heart, and liver at the end of the sixteen-week period of exposure, revealed no indications of stress.
Explore the source record for details and available documents.
Explore the source record for details and available documents.