PubMed Health⌕ Search

Biomedical subjects

C H Hämmerle

Publications and source records attributed to C H Hämmerle.

At least 19 recordsLinked to original sources

Single stage surgery combining transmucosal implant placement with guided bone regeneration and bioresorbable materials.

The aim of the present clinical study was to test whether peri-implant bone defects can successfully be filled with bone by applying bioresorbable materials for guided bone regeneration (GBR) procedures in conjunction with implants in the transmucosal healing position. Three women and 7 men ranging in age from 32 to 68 years (median 54.5) needed tooth replacement with dental implants. Eight to 14 weeks following careful tooth extraction, implants of the ITI Dental Implant System were placed at the extraction sites. At this time, all implants presented dehiscence defects of the alveolar bone partly exposing the rough titanium plasma sprayed (TPS) surfaces. GBR procedures were performed using deproteinized bovine bone mineral (Bio-Oss) as a membrane-supporting material and a bioresorbable collagen membrane (Bio-Gide) as a barrier. The membranes and the flaps were adjusted to fit around the necks of the implants, thus leaving the implants extending transmucosally into the oral cavity. Clinical measurements were taken at 6 sites around each implant (mesio-buccal, buccal, disto-buccal, disto-lingual, lingual, mesio-lingual) using a calibrated periodontal probe. These included: i) defect depth measured from the shoulder of the implant to the first bone-to-implant contact, ii) infrabony defect component measured from the bone crest to the first bone-to-implant contact, iii) defect width measured from the crest to the implant body in a direction perpendicular to the long axis of the implant. The Wilcoxon Matched Pairs Signed Rank Test was applied to detect differences over time. At baseline, the mean defect depth per patient amounted to 3.6 mm (Standard Deviation 1.6 mm, range 1.8-6.8 mm). The deepest extensions of the defects were located at the buccal aspects (mean 7.8 mm, SD 1.9 mm). At re-entry, the mean defect had decreased to 2.5 mm (SD 0.6 mm). This difference was statistically significant (P < 0.01). Initially, in 62% of sites the depth ranged from 0-3 mm, in 23% it ranged from 2-4 mm, and in 15% it amounted to more than 6 mm. Six to 7 months later, at re-entry, 95% of sites were 3 mm and less in depth and 5% ranged from 4-6 mm. Defect resolution, as assessed by the amount of coverage of the initially exposed rough implant surface, reached a mean value of 86% (SD 33%). One hundred percent resolution was accomplished at 8 out of 10 implants, 60% at one and 0% at another implant. The tissue at the latter implant showed signs of infection and inflammation during the healing phase. It is concluded that bioresorbable materials in GBR procedures at transmucosal implants can lead to successful bone regeneration into peri-implant defects.

Absorbable Implants↗

Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

The aim of this study was to compare the frequency of biological and technical complications with fixed partial dentures (FPDs) on implants, teeth and as mixed tooth-implant supported FPDs over 4 to 5 years of function. All implants belonged to the ITI Dental Implant System. Group I-I (implant FPD) included 33 patients with 40 FPDs, group T-T (tooth FPDs) 40 patients with 58 FPDs, group I-T (mixed tooth-implant FPDs) 15 with 18 FPD. Of the bridge abutments 144 were teeth and 105 were implants. The median number of units replaced by the FPDs was 3 (range 2-14). The mean age of the patients was 55.7 years (range 23-83). Complete failures resulted in the loss of one FPD in each group. Two implants were lost due to fracture secondarily to development of a bone defect. One tooth had a vertical fracture and 1 tooth was lost due to periodontitis. Biological complications (peri-implantitis, PPD > or = 5 mm and BOP+) occurred at 9.6% (10) of the implants. This number was, however, reduced to 5% if the threshold for definition of peri-implantitis was set at PPD > or = 6 mm and BOP+. Biological complications occurred in 11.8% (17) of the abutment teeth (NS compared to implants); 2.8% (4) had secondary caries, 4.9% (7) endodontic problems and 4.1% (6) had periodontitis (PPD > or = 5 mm, BOP+). Ten out of 32 patients with a general health problem indicated a biological complication, whereas 9 out of 53 patients with no general health problem had a biological complication (chi 2: NS). Statistically significantly more technical complications were found in FPDs on implants (chi 2, P < or = 0.05). The technical complications were associated with bruxism. Out of 10 bruxers 6 had a technical complication whereas 13 out of 75 non-bruxers had such a complication (chi 2 < or = 0.01). Extensions were associated with more technical complications (13 out of 35 with extensions versus 9 out of 81 without). In conclusion, favourable clinical conditions were found at tooth and implant abutments after 4-5 years of function. Loss of FPD over 4-5 years occurred at a similar rate with mixed, implant or tooth supported reconstructions. Significantly more porcelain fractures were found in FPDs on implants. Impaired general health status was not significantly associated with more biological failures but bruxism as well as extensions were associated with more technical failures.

Adult↗

Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study.

BACKGROUND: The original protocol for dental implant treatment ad modum Brånemark was based on submerged healing prior to loading. For patients, immediate implant function could reduce cost and increase attractiveness of implant treatment. PURPOSE: The goal of this study was to evaluate the short-term success rate of immediately loaded implants placed in various regions of the jaws. MATERIALS AND METHODS: Forty-one patients received a total of 127 immediately loaded implants (76 maxillary and 51 mandibular). Seventy-one percent of the patients received their prosthetic restoration the same day and the others within 11 days. All prosthetic constructions were in full contact in centric occlusion. Clinical follow-up examinations were performed at 1 week, 2 weeks, and at 1, 2, 3, 6, and 12 months after implant loading. The study was completed 1 year after loading. RESULTS: Twenty-two implants were lost in 13 patients (including 7 maxillary implants lost in 1 patient). The cumulative success rate of the implants was 82.7% after 1 year of prosthetic loading. All sites with implant losses were re-implanted, using a two-stage technique, with no further complications reported. Ninety-one percent of implants placed in regions other than the posterior maxilla were successful compared with 66% of implants placed in the posterior maxilla. Implants in patients with a parafunctional habit (bruxers) were lost more frequently than those placed in patients with no parafunction (41% vs. 12%). Implants subjected to guided bone regeneration were more successful compared with those not subjected to regeneration procedures (90% vs. 67%). CONCLUSIONS: The immediate loading concept is a realistic treatment alternative in various jawbone regions except for the posterior part of the maxilla. High occlusal loads should be considered a risk factor. On the other hand, implants in combination with bone defects frequently are penetrating cortical layers to a higher extent, thereby contributing to implant stability during the healing phase and consequently do not inevitably jeopardize the treatment result. However, further controlled clinical studies with larger sample sizes need to be performed to evaluate the influence of different parameters on treatment outcome.

Adult↗

Influence of decortication of the donor bone on guided bone augmentation. An experimental study in the rabbit skull bone.

The aim of the present study was to evaluate if early access to the endosteal bone compartment by removal of the outer cortical bone plate will enhance bone augmentation in a secluded space. Two titanium cylinders were placed on the skull of each of 8 rabbits. Each cylinder was placed into a circular slit, secured to the skull bone via two mini-screws and supplied with a titanium lid. On the test side, the outer plate of the cortical bone, demarcated by the slit, was removed. The subsequent bleeding resulted in blood fill of the cylinders to various degrees. On the control side, the corfical bone plate was left intact and no bleeding was observed at the time of the placement of the titanium lids. After 3 months, the animals were sacrificed to obtain histology and histomorphometry. No differences in the total amount of augmented bone tissue, in relation to the total experimental area (75.5% +/- 10.9% at the test sites and 71.2% +/- 13.5% at the control sites) or of the augmented mineralized bone tissue in relation to the total amount of augmented bone tissue, was revealed (17.8% +/- 3.0% and 16.0% +/- 4.9% respectively). There was no difference in the morphological appearance of the augmented bone between test and control sites and there were no obvious similarities in the appearance between the newly formed bone tissue and the donor bone. The augmented bone consisted of slender bone trabeculae, distributed in abundant marrow spaces. A conspicuous finding was that the bone trabeculae tended to climb along the inner walls of the titanium cylinder. It is concluded that decortication of the calvarial bone in the rabbit does not result in more bone formation beyond the skeletal envelope after a healing period of 3 months compared to no removal of the cortical bone plate inside a secluded experimental area.

Animals↗

Attempts to obtain re-osseointegration following experimental peri-implantitis in dogs.

The purpose of this study was to examine the healing potential and re-osseointegration in peri-implant infection defects adjacent to various implant surfaces. In 7 female Beagle dogs, a total of 41 titanium oral implants (ITI, Straumann, Waldenburg; Switzerland) with a sink depth of 6 mm (diameter 2.8 mm) were placed transmucosally. Four different surface configurations (TPS: titanium plasma sprayed (10); SLA: sand blasted and acid-etched (13); M: machined and smooth (11); TPS furc.: titanium plasma sprayed with coronally placed perforation to mimic a furcation (7) were distributed among the animals and locations. Following a healing period of 3 months, silk ligatures were placed and oral cleaning procedures abolished for 4 months to induce a vertical bone loss of about 40%. Following mechanical and chemical cleansing (chlorhexidine and metronidazole) and disinfection, the lesions were either sham operated (11) or subjected to a GTR procedure using ePTFE (30). After 6 months of healing the animals were killed and the jaws histologically evaluated. Six membranes were lost TPS: (1); SLA: (2); M: (2); TPS furc: (1) and 3 membranes exposed TPS: (1); M: (2) and excluded from further evaluation. Owing to the loss of 1 implant and infection of the membranes in the TPS furc group, this implant configuration was discarded from further analysis. For TPS surfaces, bone fill was 2.6 mm (73% of the distance from the bottom of the defect to the shoulder of the implant) sites with (4 GTR) and 0.33 mm (14%) for sites without membrane (2 controls). Re-osseointegration was 0.5 mm (14%) in the test group and 0.3 mm (14%) in the control. For SLA surfaces bone fill was 2.3 mm (83%) for sites with (7 GTR) and 0.41 mm (15%) for sites without membranes (4 controls). Re-osseointegration was 0.6 mm (20%) and 0.3 mm (11%) respectively. Corresponding values for M surfaces were 2.2 mm (62%) with 4 GTR) and 0.82 mm (31%) without membranes. Re-osseointegration was 0.07 mm (2%) and 0.19 mm (7%) respectively. This study has documented that peri-implant infections defects may heal with bone fill provided that the infection is controlled through effective antibacterial therapy. However, true reosseointegration appears to be difficult to achieve.

Alveolar Process↗

Influence of surface roughness of barrier walls on guided bone augmentation: experimental study in rabbits.

BACKGROUND: By using the guided tissue regeneration concept it is possible to augment bone, beyond the skeletal envelope, provided certain biologic, surgical, and barrier-related demands are met. Among barrier-related factors of importance are the surface properties. PURPOSE: The aim of this study was to evaluate whether different surface roughness of the barrier wall influences the amount and morphology of augmented bone in a secluded space, using a titanium cylinder as barrier device placed on the rabbit skull. MATERIALS AND METHODS: Cylinders of commercially pure titanium were fabricated by machining, using a turning tool. The inner cylinder wall was either left untreated or grit-blasted with titanium dioxide to increase surface roughness. The topographic profile of the inner surface of two cylinders (1 turned and 1 grit-blasted) was measured in vitro to achieve a numeric characterization of each type of surface topography. Two cylinders, one with grit-blasted and one with turned inner walls, were surgically placed and secured to the skull bone of each of eight rabbits. The plate of the cortical bone, facing the experimental area framed by the cylinder wall was removed, and care was taken to ensure total blood fill of the cylinders. After 3 months, the animals were sacrificed to obtain histology for histomorphometry. RESULTS: The relative volume of augmented tissue in the grit-blasted cylinders (77.9 +/- 10.5%) did not differ significantly from that in the turned cylinders (73.4 +/- 5.5%, p = .118), neither did the volume of mineralized bone (20.1 +/- 8.2% vs. 22.1 +/- 7.2%, p = .064). The trabecular density of the augmented bone was higher close to the walls of both the turned and the grit-blasted cylinders compared to the overall trabecular density within the cylinders, but no significant difference between the two groups. However, the area of mineralized bone in direct contact with the inner surface of the titanium cylinder was significantly larger in the grit-blasted (33.9 +/- 13.3%) compared to the turned cylinders (12.0 +/- 8.5%, p = .01). CONCLUSIONS: The use of titanium barriers with a grit-blasted inner surface compared to barriers with a turned surface resulted in the formation of similar amounts of bone beyond the skeletal envelope of the rabbit skull. However, a larger area of augmented mineralized bone was found in direct contact with the inner surface of the grit-blasted cylinders.

Animals↗

The effect of a deproteinized bovine bone mineral on bone regeneration around titanium dental implants.

The aim of the present experiment was to test the effect of a deproteinized bovine bone mineral (Bio-Oss) on guided bone regeneration (GBR) in dehiscence defects around implants. The first 2 molars and all premolars were extracted on both sides of the mandibles of 3 monkeys (Macaca fascicularis). Three months later, 2 titanium plasma-coated cylindrical implants were placed in all quadrants of each monkey. During the surgical procedure, standardized dehiscence defects were produced buccally and lingually, measuring 2.5 mm in width and 3 mm in height. Four different experimental situations were created: 2 sites in each monkey were covered with an ePTFE membrane (M), 2 were filled with the graft material (DBBM), 2 were filled with the graft material and also covered with a membrane (M + DBBM), and 2 control sites were neither grafted nor covered (C). The flaps were sutured to allow for primary healing. Linear measurements of bone height and width were calculated on histological specimens obtained 6 months following surgery. In addition, values for bone density and for surface fraction of graft to new bone contact were measured. Vertical bone growth along the implant surface of 100% (SD 0%) for M + DBBM, 91% (SD 9%) for M, 52% (SD 24%) for DBBM, and 42% (SD 35%) for C was measured. The width of the regenerated bone 1.5 mm above the bottom of the original defect, i.e. at the 50% mark of the vertical extension of the defect, in relation to the width at the bottom of the defect amounted to 97% (SD 2%) for M + DBBM, 85% (SD 9%) for M, 42% (SD 41%) for DBBM, and 23% (SD 31%) for C. Assessment of bone density within the confinement of the regenerated bone resulted in an increase of 30% (SD 11%) for M + DBBM, 45% (SD 20%) for M, 33% (SD 20%) for DBBM, and 22% (SD 23%) for C. The values for graft to new bone contact within this compartment amounted to 80% (SD 15%) for M + DBBM and 89% (SD 14%) for DBBM. In conclusion, Bio-Oss exhibited osteoconductive properties and hence can be recommended for GBR procedures in dehiscence defects with respect to vertical and horizontal growth of bone.

Animals↗

Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants.

In most of the studies on long-term radiographic evaluations of crestal bone levels adjacent to dental implants, no baseline radiographs taken immediately postsurgically had been obtained. The aim of this study was to test the reproducibility of a simple radiographic method for linear measurements of changes in bone levels and to evaluate changes in crestal bone levels adjacent to non-submerged ITI implants 1 year following the surgical procedure. From 128 patients enrolled in a clinical and radiographic longitudinal study 40 patients also had radiographs taken immediately postsurgically. They were, however, not obtained as "identical" images. The radiographs were mounted onto slides and projected on a screen. Mesially and distally from 57 implants triplicate linear measurements of the distance implant shoulder to bone crest were taken, using known dimensions of the implants as internal reference distances. The median difference of 213 (out of 228 possible) duplicate measurements was 0.00 mm (ranging from -1.72 mm to +1.47 mm when comparing the second to the third reading). Some 81% of the double measurements were within +/- 0.5 mm and the precision was 0.30 mm. In the immediate postoperative radiographs the median mesial bone level was located at 2.07 mm (distally 2.19 mm) from the implant shoulder. A statistically significant amount of bone loss in the first year was observed mesially (median = -0.78 mm) and distally (-0.85 mm) (Wilcoxon matched pairs signed rank test P < or = 0.001). No statistically significant influence of the implant location, the implant length, type of the implant (screw; cylinder) was observed (Kruskal-Wallis P > 0.05). The age of the patients was not correlated significantly to the amount of bone loss observed. In conclusion, methodological limitations existed when evaluating linear bone changes in non-identical radiographs using reference dimensions of the implants. The amount of postsurgical bone loss estimated in other studies was confirmed when using an immediate postoperative radiograph as a baseline.

Adolescent↗

Bone-to-implant contact of orthodontic implants in humans subjected to horizontal loading.

Implant-based anchorage in orthodontics is increasingly obtaining significance. In this study, implants were temporarily inserted into the mid-palatal and the mandibular retromolar areas in humans for orthodontic anchorage. Histological analysis of the implant-bone interface was performed following the retrieval of implants which were subjected to prolonged oblique orthodontic loading. The results of the histomorphometric evaluation indicated that all the implants serving for orthodontic anchorage were well integrated into the bone despite the prolonged application of the orthodontic loading. Hence, it may be concluded that small-size, one-part transmucosal implants with a self-tapping thread and an SLA surface seemed to provide adequate anchorage for orthodontic therapy. Furthermore, the successful integration and the subsequent oblique loading of these orthodontic implants provide evidence that continuous forces in the order of magnitude of 2-6 N are compatible with the maintenance of osseointegration.

Adolescent↗

Plaque formation and gingivitis after supervised mouthrinsing with 0.2% delmopinol hydrochloride, 0.2% chlorhexidine digluconate and placebo for 6 months.

OBJECTIVES AND METHODS: A double-blind, randomized, 6-month clinical trial with parallel group design in 162 patients with gingivitis divided into three rinsing groups was conducted in order to study the efficacy and safety of a flavoured solution of delmopinol hydrochloride 2 mg ml-1 (0.2% w/v, Decapinol Mouthwash) used for supervised mouthrinsing in one rinsing group, in comparison with chlorhexidine digluconate 2 mg ml-1 (0.2% w/v, Hibitane Dental) in a second rinsing group, and placebo in the third group. The criteria of the Plaque Index (PI) were used to assess plaque formation. Bleeding on probing (BOP) to the bottom of the pocket with a standard pressure was used as the primary gingivitis assessment. The occurrence of supragingival dental calculus and extrinsic tooth staining were also assessed. In addition, patients were asked to report adverse events at each visit. RESULTS: Delmopinol and chlorhexidine exhibited lower scores of the mean PI and the BOP percentage than placebo, both at the 3-month and 6-month examinations. Furthermore, both active solutions showed a higher extent of staining of the teeth than placebo during these two observation periods. Rinsing with chlorhexidine resulted in more dental calculus than placebo after 6 months. Chlorhexidine showed lower scores for plaque formation and gingivitis development but higher scores of supragingival dental calculus (after 6 months) and tooth staining than did delmopinol. Both active solutions were reported by the patients--approximately to the same extent but more frequently than placebo--to induce taste alterations and a transient anaesthetic sensation of the oral mucosa. However, subjective staining of the teeth and tongue was reported by 16% of the delmopinol patients, but by 86% of the patients rinsing with chlorhexidine for 6 months. Furthermore, 24% of the patients in the chlorhexidine group, 9% in the delmopinol group and 4% in the placebo group wished to withdraw from treatment. CONCLUSIONS: The results from this clinical trial indicate that supervised rinsing with 0.2% delmopinol hydrochloride or with 0.2% chlorhexidine digluconate twice daily for 60 s as a supplement to normal mechanical oral hygiene procedures resulted in less plaque formation and gingivitis than rinsing with placebo. Although chlorhexidine was more effective than delmopinol regarding plaque formation and gingivitis, it was considered by the patients as less tolerable.

Adult↗

Blood-filled spaces with and without filler materials in guided bone regeneration. A comparative experimental study in the rabbit using bioresorbable membranes.

The aim of the present study was to evaluate the effect of natural deproteinized bone mineral on the temporal and spatial pattern of bone formation in a guided bone regeneration model system while using a bioresorbable membrane device. A periosteal skin flap was raised uncovering the calvaria of 20 rabbits. A stiff hemispherical dome made of polylactic acid was placed onto the roughened calvaria and anchored by screws. Prior to placement, the dome was either filled with peripheral blood (control group, 8 rabbits) or with blood and OsteoGraf/N-300 (test group, 12 rabbits). At 1 month, histologic sections revealed bone regeneration in both test and control domes to various degrees. In the test domes, bone height reached 78% (67-83) and bone volume was 11% (6-17), while in the control domes, bone height was 45% (14-67) and bone volume 6% (1-11). At 2 months, bone height was unchanged in the test group at 70% (67-83) and bone volume had only slightly increased to 16% (11-21). In the controls, height increased to 86% (60-100) and volume to 20% (9-27). Thus, in this model system, natural bone mineral fill contributed to accelerate initial bone neogenesis, while it did not contribute to increasing bone volume or bone height at later observation stages.

Animals↗

The biological effect of natural bone mineral on bone neoformation on the rabbit skull.

The aim of this study was to evaluate the effect of deproteinized bovine bone graft material on new bone formation in a guided bone regeneration model system. In 20 rabbits, a periosteal skin flap was raised uncovering the calvaria. A form stable hemispherical dome made of poly-lactic acid (PLA) was placed onto the roughened calvaria. Prior to placement, the dome was either filled with peripheral blood alone (control group, 8 rabbits), or with blood and OsteoGraf/N-300 (test group, 12 rabbits). The wound was closed for primary healing. Morphometric assessment of 1- and 2-month undecalcified histologic specimens revealed better tissue fill in the test domes at 1 month (test 99%, control 55%) (P < 0.05) and 2 months (t, 100%; c, 82%). The fraction of the new bone within the regenerated tissue was higher in the test specimens at 1 month (t, 22%; c, 12%) (P < 0.05) and 2 months (t, 34%; c, 24%). The fraction of the entire space underneath the domes occupied by bone was higher in the test at 1 month, but higher in the controls at 2 months. The fraction of the bone substitute material in contact with bone increased from 1 month (34% +/- 14) to 2 months (45% +/- 5). The surface fraction of osteoblast layers was tendentially higher in the test at 1 month but higher in the control specimens at 2 months. In both test and control, initially woven bone was formed which underwent subsequent remodeling. Cellular degradation of the deproteinized bone graft was frequently detected. It is concluded that deproteinized bovine bone mineral has osteoconductive properties and can initially accelerate new bone formation during guided bone regeneration by increased recruitment of osteoblasts.

Animals↗

The significance of angiogenesis in guided bone regeneration. A case report of a rabbit experiment.

A dome-shaped bioresorbable membrane was fixed to the wounded rabbit calvaria and filled with a bioresorbable fibre conglomerate. After 4 weeks, the histologic preparation revealed an intimate spatial and temporal correlation between newly formed blood vessels and de novo extraskeletal bone formation. These observations emphasize the significance of angiogenesis in guided bone generation.

Animals↗

Associations between clinical parameters assessed around implants and teeth.

The aim of the present study was to clinically assess the peri-implant and periodontal conditions 1 year after placement of oral implants (ITI Dental Implant System) in partially edentulous patients. In all, 127 patients (median age 50 years, range 17 to 79) were examined. They were all treated according to a concept of comprehensive dental care and had received fixed partial dentures (FPD). Significant differences were observed between implants and contralateral control teeth with respect to mean pocket probing depth (PPD) (2.55 mm at implants/2.02 mm at teeth), mean probing attachment level (PAL) (2.97 mm/2.53 mm) and bleeding on probing (BOP) (24%/12%) (Wilcoxon matched pairs sign rank test, P < or = 0.01), whereas mean modified plaque index (0.22/0.30), mean modified bleeding index (0.35/0.44) and mean recession (-0.42 mm/-0.51 mm) did not significantly differ between implants and teeth. Compared to control teeth, the width of keratinized mucosa at implants was significantly smaller at lingual, but not at buccal aspects. Regression analyses showed no significant association between the amount of keratinized mucosa and degree of inflammation. Recession, PPD and PAL were slightly influenced by the amount of keratinized mucosa indicating greater resistance to probing. Grouping the implants according to various lengths, type of fixation of the FPD or combination with natural teeth did not result in statistically significant different clinical parameters, whereas grouping according to different localization within the oral cavity did. For example, the mean PAL in 83 anterior implants was 2.52 mm, whereas 175 posterior implants had a mean PAL of 3.18 mm (Mann-Whitney U-test, P < or = 0.01). Regression analyses between the mean PAL for all implants in each patient and the mean PAL of the corresponding dentition revealed an r2 of 0.23 (P < or = 0.01). Using multiple regression analysis, the mean PAL of the implants showed to be significantly influenced by the combined factors "fullmouth" PII, "fullmouth" BOP and mean PAL of all teeth. The results of this study suggest that in partially edentulous patients the overall periodontal condition may influence the clinical condition around implants and thus reinforces the importance of periodontal treatment prior to and supportive periodontal therapy after the incorporation of osseointegrated oral implants.

Adolescent↗

Clinical trials on therapies for peri-implant infections.

Peri-implant infections are pathological conditions which are normally localized in the soft tissues surrounding an oral implant. They may range from a rather localized mucositis lesion reflecting the host response to a bacterial challenge to a more advanced lesion "termed peri-implantitis" when previously osseointegrated oral implants have been partially disintegrated; i.e. have lost alveolar bone around the implant. Usually these lesions start as a result of plaque accumulation and show similar progression as observed around teeth. Muscositis seems to be a prerequisite for the following peri-implantitis. However, the factors involving the transition to a more advanced lesion are still not known. Logically, the therapy for peri-implant infection has to be related to antibacterial treatment prior to the attempt to surgically regenerate peri-implant alveolar bone lost as a result of the infection. In order to diagnose these lesions at an early stage frequent assessments of clinical parameters are needed during maintenance therapy. The anti-infective treatment may intercept the development of the lesion. Following mechanical debridement of plaque deposits the application of efficacious antiseptics (chlorhexidine) is a necessity. Following this, antibiotics may cumulatively be applied to control the infection. Only a few longitudinal studies have documented the efficacy of such treatment regimens, and controls have generally not been available for ethical reasons. In regenerating the lost jaw bone only case reports are available today. Controlled animal studies will have to be performed to document the possibility of re-osseointegration and the factors influencing predictability.

Animals↗

A novel model system for the study of experimental guided bone formation in humans.

The aim of the present experiment was to test a novel model system, designed to obtain human specimens of regenerated and also newly regenerated jaw bone, for the study of the biological events under a variety of conditions. Following information and disclosure of possible risks associated with a minor oral surgical procedure, 9 systemically healthy subjects (5 men, 4 women, mean age 31.7 years) signed consent forms and volunteered to participate in this study. Hollow test cylinders with an outer diameter of 3.5 mm, an inner diameter of 2.5 mm, and 4 mm in height were used. They were manufactured from commercially pure titanium and exhibited a highly polished inner surface and a titanium plasma sprayed outer rough surface. A mucoperiosteal flap was raised in the retromolar area of the mandible corresponding to standard retrained third molar surgery. Following flap reflection a standardized hole was drilled through the cortical bone into the bone marrow using round burs. The congruent test cylinders were firmly placed into the prepared bony bed yielding primary stability. One-and-a-half to 2 mm of the test device were submerged below the level of the surrounding bone, while the remainder surpassed the level of the bone surface. The bone-facing end of the cylinder was left open, while the coronal soft tissue facing end was closed by an ePTFE-membrane. The flap was sutured to obtain primary wound closure. In order to prevent infection, penicillin was prescribed systemically and oral rinses of chlorhexidine were administered. After 2, 7, and 12 weeks one test device including the regenerated tissue was surgically harvested, while after 16, 24 and 36 weeks respectively, 2 devices were harvested and processed for soft or hard tissue histology or histochemistry. The two surgical procedures and the presence of the test cylinders during the time of healing were well tolerated by the volunteers. In all 9 subjects generated tissue could successfully be harvested. The tissue generated after 2 and 7 weeks presented with a cylindrical shape, whereas the specimens harvested at 12 weeks and thereafter resembled the form of an hourglass. Specimens of 12 weeks and less regeneration time were almost entirely comprised of soft tissue, while specimens with regeneration time of 4 months and more were composed of both soft and increasing amounts of mineralized tissue. It is concluded that the presented model system is suitable to study temporal dynamics and tissue physiology of bone regeneration in humans with minimal risk for complications or adverse effects to the volunteers.

Adult↗

Thresholds for tactile sensitivity perceived with dental implants remain unchanged during a healing phase of 3 months.

The aim of the present study was to determine the tactile pressure thresholds perceived with dental implants during a three-month healing phase following implant placement (osseointegration phase). The absolute threshold of tactile perception was measured in a group of patients 1 week, 1, 2 and 3 months following implant placement (ITI Dental Implant System, Straumann AG, Waldenburg, Switzerland). Contralateral and neighbouring teeth were measured at the same time. For determination of the axial forces exerted on the implants and teeth, and electronic device with semi-conductor strain gauges was used (Hämmerle et al. 1995). The results demonstrated mean thresholds of tactile perception for the implants of 160.2 g (SD 61.7 g, range 77 approximately 283 g) at 1 week, 133.4 g (SD 51.9 g, range 32 approximately 239 g) at 1 month, 147.9 g (SD 53.5 g, range 70 approximately 257 g) at 2 months, and 146.9 g (SD 57.4 g, range 77 approximately 248 g) at 3 months. Statistical analysis using Student's paired t-test revealed no significant differences between the values over time. The control teeth exhibited mean values for tactile perception of 13.1 g (SD 9.6 g, range 5 approximately 47 g) at 1 week, 10.2 g (SD 6.4 g, range 4 approximately 29 g) at 1 month, 14.8 g (SD 15.9 g, range 2 approximately 58 g) at 2 months, and 15.4 g (SD 12.2 g, range 3 approximately 36 g) at 3 months. Again, these values did not differ significantly from each other and indicated the absence of systemic alterations in perceived pressure threshold over the observation period. The mean perceived pressure threshold was more than 10 times higher for implants than for natural teeth (P < 0.001) at all observation times. It is concluded that the absolute threshold of tactile perception with dental implants during the phase of osseointegration is not affected by bone and soft tissue healing taking place during the time period.

Adult↗