Radiation dosimetry for electron beam CT.

PURPOSE: To measure the radiation dose profile, multiple-scan average dose (MSAD), and computed tomography dose index (CTDI) for electron beam CT and to determine the accuracy of ionization-chamber and manufacturer estimates of patient dose. MATERIALS AND METHODS: High-resolution dose profiles along the longitudinal axis were acquired at several positions within the scan plane with use of radiographic film. The full-width-at-half-maximum values, peak radiation dose, CTDI, and MSAD were calculated from the digitized film profiles. CTDI was also measured with an ionization chamber. RESULTS: The full-width-half-maximum value of the radiation profiles were significantly wider than the nominal scan width for the 6-mm single-section and 8-mm multisection modes. In the single-section mode, the CTDI underestimated the MSAD by 15%-30%. The multisection radiation profile was nonuniform and asymmetric. CONCLUSION: Patient doses in electron beam CT are approximately 125% of the ionization-chamber CTDI measurements in the single-section mode. For the multisection mode, the average patient dose over the scan volume is approximately 70%-85% of the ionization-chamber CTDI measurements.

Humans↗

The technical design and performance of ultrafast computed tomography.

The ultrafast radiograph CT scanner utilizes a scanning electron beam and semicircular tungsten targets to produce a moving radiograph source about the patient, thus eliminating mechanical motion within the gantry. This design allows scan times as short as 50 or 100 ms, as well as two levels of image resolution. The short scan time reduces the effects of motion blurring and artifacts and provides the ability to obtain high-quality images of dynamic processes and rapidly moving organs. When utilized in the SS (high-resolution) mode, the UFCT scanner provides contiguous image acquisition through a patient volume at rapid speeds, yet maintains image quality comparable with conventional CT scanners. This technology provides extremely short exposure times, rapid acquisition of multiple slices, continuous scanning without concern for anode heat storage and dissipation, and the ability to image moving organs or flowing contrast media. Many clinical applications exist that exploit these unique features.

Heart Diseases↗

Densitometric assessment of regional left ventricular systolic function during graded ischemia in the dog by use of dual-energy digital subtraction ventriculography.

Densitometric analysis of images obtained by digital subtraction angiography (DSA) allows for more reproducible and less operator-dependent quantitation of ventricular function. Conventional DSA uses temporal subtraction but is limited by misregistration artifacts. Dual-energy digital subtraction angiography (DE-DSA) is immune to such misregistration artifacts. The ability of DE-DSA to quantitate changes in regional ventricular volume resulting from ischemia was tested. Densitometric analysis of both phase-matched and ejection fraction DE-DSA images was used to quantitate regional left ventricular systolic function during four levels of ischemia ranging from mild to severe in open-chest dogs (n = 10). DE-DSA left ventriculograms were obtained by means of central venous injections of iodinated contrast medium. Ischemia was graded according to percentage of systolic wall thickening as measured by sonomicrometry. Phase-matched end-systolic images were obtained at each of four levels of ischemia by subtracting an end-systolic control image from each end-systolic ischemic image. Ejection fraction images were obtained at the control level and at each level of ischemia by subtracting an end-systolic image from an end-diastolic image of the same cardiac cycle. The resulting wall motion difference signals represent the changes in regional ventricular volumes and were quantitated by densitometry. Densitometry was able to detect the effect of all levels of ischemia on regional function, even the mildest. Densitometric analysis of both phase-matched and ejection fraction DE-DSA images provides a sensitive technique for detecting and quantitating the changes in regional left ventricular systolic volume that occur with ischemia.

Angiography, Digital Subtraction↗

Optimization of multidetector array CT acquisition parameters for CT colonography.

BACKGROUND: Multidetector array computed tomography technology has increased the number of acquisition parameters that a user must select. This article examines the criteria by which detector collimation, reconstructed scan width, reconstruction scan interval, pitch, image noise, and patient dose can be optimized. METHODS: A water phantom containing tissue-equivalent polyps in an air-filled tube was scanned using multiple acquisition parameter combinations. X-ray tube current was changed to independently match dose and noise to a single-detector array technique. Images were assessed in axial and three-dimensional formats. RESULTS: All polyps were visible in axial and three-dimensional images for all scans. Helical artifacts were noted at higher table speed values. The 5-mm-wide scans spaced at 3-mm intervals allowed visualization of the smallest polyps: 5 x 5 or 7 x 3 (diameter x height; mm). CONCLUSION: Our results indicate that thin-scan and low-noise techniques need not be used to visualize polyps of clinically relevant sizes.

Artifacts↗

An electron-beam CT approach for transvenous coronary arteriography.

OBJECTIVE: The goal is to image the 3D anatomy of the major coronary arteries within a single breath-hold and using a single intravenous injection of contrast agent. MATERIALS AND METHODS: With use of an electron-beam CT (EBCT) scanner, operated in its multislice scan mode (using all four target rings, each scanning two nominal 8 mm thick slices in a total time interval of 224 ms), a radiologically realistic thorax phantom containing a heart with coronary arteries (opacified with 40 mg iodine/ml) was scanned six times with the patient table advanced by a 2 mm step into the scanner between each scan. The normalized and scaled sinogram data were transferred to an off-line computer and reconstructed using our own implementation of a 3D algebraic reconstruction technique that takes into account the exact 3D relationship of the X-ray source and detector elements of the EBCT. RESULTS: A single volume image consisting of 40 slices, at 2 mm intervals and each uniformly 3.7 mm thick, depicted the lumina of the coronary arteries with greater anatomic detail than the "original" images at 8 mm, primarily because of the reduced partial volume effect. CONCLUSION: Our preliminary results suggest that EBCT, operated in multislice scan mode, may be useful for transvenous coronary angiography performed within a single breath-hold.

Coronary Angiography↗

An auxiliary CT tabletop for radiography at the time of CT.

An auxiliary CT tabletop was designed and manufactured such that radiographic images might be acquired, with use of a ceiling-mounted X-ray tube, without removing the patient from the CT table. The tabletop required no modifications to the original CT table housing and did not produce artifacts in the CT images. Radiographs obtained with the overhead X-ray tube and auxiliary tabletop demonstrated image quality equivalent to traditional radiographs.

Equipment Design↗

A correlated noise reduction algorithm for dual-energy digital subtraction angiography.

It has long been recognized that the problems of motion artifacts in conventional time subtraction digital subtraction angiography (DSA) may be overcome using energy subtraction techniques. Of the variety of energy subtraction techniques investigated, non-k-edge dual-energy subtraction offers the best signal-to-noise ratio (SNR). However, this technique achieves only 55% of the temporal DSA SNR. Noise reduction techniques that average the noisier high-energy image produce various degrees of noise improvement while minimally affecting iodine contrast and resolution. A more significant improvement in dual-energy DSA iodine SNR, however, results when the correlated noise that exists in material specific images is appropriately cancelled. The correlated noise reduction (CNR) algorithm presented here follows directly from the dual-energy computed tomography work of Kalender who made explicit use of noise correlations in material specific images to reduce noise. The results are identical to those achieved using a linear version of the two-stage filtering process described by Macovski in which the selective image is filtered to reduce high-frequency noise and added to a weighted, high SNR, nonselective image which has been processed with a high-frequency bandpass filter. The dual-energy DSA CNR algorithm presented here combines selective tissue and iodine images to produce a significant increase in the iodine SNR while fully preserving iodine spatial resolution. Theoretical calculations predict a factor of 2-4 improvement in SNR compared to conventional dual-energy images. The improvement factor achieved is dependent upon the x-ray beam spectra and the size of blurring kernel used in the algorithm.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

The AAPM/RSNA physics tutorial for residents. X-ray production.

X-rays are produced when highly energetic electrons interact with matter and convert their kinetic energy into electromagnetic radiation. The two unique mechanisms by which x-rays are produced are called the bremsstrahlung and characteristic processes. Bremsstrahlung x-rays produce a continuous x-ray spectrum, whereas characteristic x-rays are produced at specific narrow bands of energies. Many technical parameters of the x-ray production equipment affect the magnitude and shape of the x-ray spectrum. The quantity of x-rays produced varies proportionally to the tube potential squared, tube current, exposure time, and atomic number of the anode material and is inversely proportional to the distance squared. x-ray quantity is also affected by the voltage waveform (generator type) and tube filtration. The shape of the x-ray spectrum is affected by the atomic number of the anode material, tube potential, filtration, and voltage waveform.

Health Physics↗

Motion artifacts in subsecond conventional CT and electron-beam CT: pictorial demonstration of temporal resolution.

To visually demonstrate the effective temporal resolution of subsecond conventional (slip-ring) and electron-beam computed tomographic (CT) systems, two phantoms containing high-contrast test objects were scanned with a slip-ring CT system (effective exposure time, 0.5 second) and an electron-beam CT system (exposure time, 0.1 second). Images were acquired of each phantom at rest, during translation along the x axis at speeds of 10-100 mm/sec, and during rotation about isocenter at speeds of 0.1 and 0.5 revolution per second. Motion artifacts and loss of spatial resolution were judged to be absent, noticeable, or severe. For 0.5-second conventional CT images, motion artifacts and loss of spatial resolution were noticeable at 10 mm/sec and 0.1 revolution per second and were severe at speeds greater than or equal to 20 mm/sec and at 0.5 revolution per second. For 0.1-second electron-beam CT scans, noticeable, but not severe, motion artifacts and loss of spatial resolution occurred at speeds between 40 and 100 mm/sec and at 0.5 revolution per second. Over the range of physiologic speeds examined, the images provide visually compelling evidence of the effect of improving temporal resolution in CT.

Artifacts↗