PubMed Health⌕ Search

Biomedical subjects

C H Rorabeck

Publications and source records attributed to C H Rorabeck.

At least 37 records · Page 2Linked to original sources

The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty.

BACKGROUND: We previously reported our two and five-year results of arthroplasty with the Porous Coated Anatomic total hip prosthesis. We now report on the performance of this prosthesis at ten to fourteen years. METHODS: The results of 311 total hip replacements in which a Porous Coated Anatomic prosthesis was inserted without cement in 279 patients were analyzed prospectively. The average age of the patients at the time of the replacement was sixty--one years (range, twenty to eighty-one years). Sixty-four patients (seventy-six hips) died postoperatively. Forty-five patients (forty-seven hips) were lost to follow-up, and four were excluded because of their medical condition. One hundred and sixty-eight patients (187 hips) were followed for ten to fourteen years (average, twelve years). Seventeen of those patients (seventeen hips) had a revision. RESULTS: The overall survival rate (with any revision as the end point) was 90.0% +/- 5.4% at fourteen years, with an average Harris hip score of 85 +/- 14 points. The prevalence of thigh pain was 36% (fifty-six of 157) in the late period (more than ten years postoperatively). Radiographs showed stable fixation, with bone ingrowth, of 83% (130) of the 156 acetabular components and 88% (137) of the 156 femoral components at the latest follow-up evaluation. Men had a significantly higher rate of femoral osteolysis than did women (p < 0.001). The rates of acetabular and femoral osteolysis associated with 32-mm femoral heads (49% [twenty-three] of forty-seven and 70% [thirty-three] of forty-seven, respectively) were significantly higher (p < 0.01) than those associated with 26-mm heads (26% [twenty-eight] of 109 and 30% [thirty-three] of 109, respectively). Despite this, revision (removal or exchange of components) was not directly related to head size; instead, it was related to polyethylene thickness. CONCLUSIONS: There have been persistent problems with the Porous Coated Anatomic hip system, including thigh pain and an increasing prevalence of osteolysis with time. Revision because of aseptic loosening was related more to the thickness of the polyethylene liner than to the size of the femoral head. Femoral heads with a 32-mm diameter did not increase the risk for revision provided that an adequate thickness of polyethylene had been used.

Adult↗

Tapered titanium cementless total hip replacements: a 10- to 13-year followup study.

The 10- to-13 year performance of 307 Mallory Head cementless tapered total hip replacements in 283 patients was assessed. Eighty-five percent of patients had a diagnosis of osteoarthritis. Fifty-one percent of patients were women. The mean patient age was 64 +/- 10 years. The Hex Loc cementless acetabular component and titanium alloy femoral heads were used in each patient. At final followup, 37 (13%) patients died, 32 (10%) had revision surgery, and two (1%) were lost to followup. No femoral stem was revised for aseptic loosening, but one was revised because of sepsis and one was revised because of a periprosthetic fracture. Wear, osteolysis, and loosening were problems with the Hex Loc cementless acetabular components and 31 (10%) acetabular components required revision because of these mechanisms. The mean Harris hip score at final followup of the remaining patients was 87 +/- 14 points. Three percent of these patients had thigh pain. Radiographic assessment revealed that no femoral stem or acetabular socket was definitely or probably loose. Three-dimensional wear assessment using the Devane technique was 0.35 mm per year. The Mallory Head cementless, tapered femoral component performed well in the patients in the current study, but unfortunately, the clinical results were compromised by the use of a suboptimal cementless acetabular component, the use of polyethylene that was gamma-irradiated in air, and by the use of titanium alloy femoral heads. Future developments obviously will be in the areas of better acetabular component design, alternate polyethylene sterilization methods, and enhancements of the femoral stem in terms of offset choices, neck design, and perhaps ingrowth surface.

Aged↗

Prospective randomized clinical trial of continuous passive motion after total knee arthroplasty.

The authors report the results of a prospective randomized clinical trial using continuous passive motion after total knee arthroplasty. One hundred twenty patients were assigned randomly to one treatment group: No continuous passive motion (Group I), continuous passive motion from 0 degrees to 50 degrees and increased as tolerated (Group II), and continuous passive motion from 70 degrees to 110 degrees (Group III). The continuous passive motion was initiated in the recovery room and was maintained for a maximum of 24 hours at which point all patients began identical postoperative physiotherapy regimens. Patients were assessed preoperatively, during their hospital stay, at 6 weeks, 12 weeks, 26 weeks, and 52 weeks after their surgery. There were no statistical differences between any of the treatment groups regarding cumulative analgesic requirements, range of motion at any measured interval, length of stay (Group I, 5.1 days; Group II, 5.2 days; Group III, 5 days) or Knee Society scores. The current study does not support the use of short-term continuous passive motion after total knee replacement. A standard and a high flexion continuous passive motion protocol failed to show any advantage over physiotherapy alone in the parameters evaluated.

Analgesics↗

Extensile exposures for revision hip arthroplasty.

Revision arthroplasty is being performed with increasing frequency and the cases are becoming increasingly complex. A key component to successful revision surgery is the surgical exposure. This is influenced by the surgeon's experience, the reason for revision, the type of components to be revised, the type of bone defects, and the previous exposures used. In simple revisions one of the standard hip approaches with which the surgeon is familiar often will suffice. However, with more complex cases an extensile or specialized approach may be necessary. No one approach is suitable for all cases and the surgeon must be familiar with several approaches, their relative indications, and possible complications.

Arthroplasty, Replacement, Hip↗

Classification of periprosthetic fractures complicating total knee arthroplasty.

As the total number of knee arthroplasties increase, the frequency with which periprosthetic fractures will be encountered can be expected to increase as well. The classification of these fractures is an important aspect in the development of an understanding of these problems. Adequate classification systems allow accurate communication between researchers and comparisons to be made between different techniques. Classification systems also allow algorithms to be developed to guide clinicians in the diagnosis, investigation, and treatment of these fractures. The authors present an outline of the classification systems described for fractures occurring in relation to total knee arthroplasty.

Arthroplasty, Replacement, Hip↗

Periprosthetic fractures of the femur complicating total knee arthroplasty.

Fractures of the femur in the presence of a total knee arthroplasty may occur intraoperatively or postoperatively. Management of these fractures is often challenging because of a variety of factors, including those related to the fracture itself, and the quality of the bone, prosthesis, and patient. Treatment options include nonoperative methods, reduction and internal fixation, and revision of the arthroplasty. Complications of treatment are not uncommon and may be severe. These issues are discussed in the article.

Algorithms↗

Total knee replacement: should it be cemented or hybrid?

OBJECTIVE: To compare the complication rates associated with total knee arthroplasty against the types of fixation (hybrid or cemented), using a single total knee design (the anatomic modular knee [AMK] prosthesis). DESIGN: A prospective, nonrandomized, controlled trial. SETTING: University Hospital in London, Ont., a tertiary care teaching centre. PATIENTS: Two groups made up of 484 knees in 395 patients (89 bilateral). INTERVENTIONS: In 260 knees a hybrid configuration (cemented tibia and noncemented femur) was used (group 1). In 224 knees the femoral and tibial components were cemented (group 2). All patellae were cemented in both groups. MAIN OUTCOME MEASURES: Clinical results were assessed by The Knee Society Clinical Rating Scores at 3 months, 6 months and yearly intervals. Radiographic results were determined by 3-foot standing radiographs and at each follow-up visit standing knee radiographs, lateral and skyline views. Radiographs were analysed for alignment, presence or absence of radiolucent lines or changes in the position of the implant. All reoperations and nonoperative complications were recorded. RESULTS: At an average follow-up of 4.8 years, 8 knees (1.6%) required reoperation. An analysis of the complications leading to reoperation demonstrated no difference between the 2 groups. CONCLUSIONS: There was no difference in outcome whether the femoral component was cemented or not. Medium-term results of the AMK are excellent with a very low reoperation rate.

Aged↗

The Install Award. Survivorship of the high tibial valgus osteotomy. A 10- to -22-year followup study.

The results of 106 high tibial valgus osteotomies in 85 patients were evaluated after a minimum 10-year followup to determine survivorship, complications, and risk factors associated with failure. Using Kaplan-Meier survivorship analysis, 73% of patients at 5 years, 51% of patients at 10 years, 39% at 15 years, and 30% at 20 years after high tibial osteotomy had not required conversion of the high tibial osteotomy to a total knee arthroplasty. Univariate Cox regression analysis of risk factors showed that age older than 50 years, previous arthroscopic debridement, presence of a lateral tibial thrust, preoperative knee flexion less than 120 degrees, insufficient valgus correction, and development of delayed union or nonunion were significantly associated with probability of early failure. Multivariate Cox regression analysis showed that a body mass index of less than 25 kg/m2, presence of a lateral tibial thrust, and development of delayed union or nonunion were significantly associated with probability of early failure. Using recursive partitioning analysis of risk factors with the Wilcoxon test, a subset of patients who were younger than 50 years of age and who had preoperative knee flexion greater than 120 degrees had a probability of survival after high tibial osteotomy approaching 95% at 5 years, 80% at 10 years, and 60% at 15 years. These results suggest that survival of high tibial osteotomy can be improved through careful patient selection and surgical technique.

Adolescent↗

Popliteal vessels in knee surgery. A magnetic resonance imaging study.

Popliteal artery injury during surgery of the knee is rare but can have devastating consequences. The position of knee flexion has been thought to be protective for the popliteal artery, allowing it to fall back from the knee joint. No prior study has provided in vivo cross sectional evidence of the behavior of the popliteal vessels during knee flexion with the effect of gravity. Magnetic resonance imaging was used in nine volunteers to measure the distance of the popliteal artery and veins from the posterior proximal tibia at two levels corresponding to the levels of osteotomy in total knee arthroplasty and in high tibial osteotomy. Scans were taken with the knee in full extension and at 90 degrees flexion with the patient in the supine position, allowing for the effect of gravity. Considerable variation in behavior of the vein and the artery was observed at the high tibial osteotomy cross sectional level and the total knee arthroplasty cross sectional level. In two knees at the high tibial osteotomy cross sectional level and in two knees at the total knee arthroplasty cross sectional, level the artery moved closer to the posterior tibia with knee flexion. Even with the effect of gravity included, knee flexion does not guarantee removal of the popliteal vessels from potential harm during surgery of the knee.

Arthroplasty, Replacement, Knee↗

Joint line restoration after revision total knee arthroplasty.

In 99 patients, 107 knee replacements were revised in two centers by two surgeons using a single revision total knee arthroplasty system. A retrospective radiographic review of joint line position before and after revision total knee arthroplasty was made, and compared with the joint line position before primary knee arthroplasty. Prospectively collected Knee Society Clinical Rating Scores were correlated with radiographic findings. The joint line position in unreplaced knee replacements averaged 16 mm, and the joint line position in knee replacements before revision surgery averaged 17 mm. The joint line was elevated by the revision total knee arthroplasty in 85 of 107 knees (79%). After the revision total knee replacement, the joint line elevation averaged 24 mm. The Knee Society Clinical Rating Score after revision surgery averaged 131 points. If the joint line position was elevated more than 8 mm, the Knee Society Clinical Rating Score averaged 125 points, if the joint line was elevated less than 8 mm, the score averaged 141 points. Joint line elevation after revision total knee replacement is a problem. Excessive elevation may result in worse clinical outcomes. Distal femoral augments should be used more often and with greater thicknesses. Standard implants used for revision surgery should have increased distal dimensions.

Aged↗

Medium-term results of a mobile bearing total knee replacement.

Mobile bearing total knee arthroplasty kinematically allows the advantages of large and congruent surface contact and low contact pressures, while preserving flexion, extension, and rotation in knee motion. In allowing for these degrees of freedom, the interface between bone and component also is protected from high stress. The Self Aligning I total knee arthroplasty initially was implanted in patients after its development at the authors' institution in 1990. Between 1990 and 1994, 141 patients with osteoarthritis of the knee underwent 172 total knee replacements using this system. At average followup of 5.6 years (range, 5-8 years), clinical results using this system showed a 94% satisfaction rate (good or very good). Two revision surgeries have been performed for polyethylene wear, with none of the remaining knees showing evidence of discernible wear. Complications included four cases of deep infection, four cases where a press fit femoral component failed (nonporous coated) and the patients required revision surgery, four traumatic fractures (three patellar and one supracondylar), one popliteal artery occlusion, and one revision for stiffness. Three patients required manipulation under anesthesia for arthrofibrosis. Kaplan-Meier survival curves show the probability of survival to be 91.7%, with revision surgery for any reason as an end point, and 98.8% for revision surgery because of polyethylene wear as an end point. Following the initial learning curve with this prosthesis, the medium term results using this system show maintenance of clinical success. No progressive evidence of polyethylene wear with time has been found, supporting the concept of mobile bearing arthroplasty in extending the service life of total knee arthroplasty.

Aged↗