PubMed Health⌕ Search

Biomedical subjects

C H Stern

Publications and source records attributed to C H Stern.

4 recordsLinked to original sources

Memory performance used to detect radiation effects on cognitive functioning.

Although radiotherapy remains a necessary and frequently used treatmentfor brain tumors, uncertainty remains about the nature and severity of neurocognitive morbidity. We show that verbal-semantic memory (free recall of word list) is sensitive to damaging radiation effects in 20 patients with low-grade, supratentorial, primary brain tumors who received moderate doses of partial-brain irradiation. We previously reported that verbal-semantic memory is dissociated from visual memory (acquisition and recall) during the same phase ofradiation effects, indicating that memory is differentially affected by radiation. In this study, we provide evidence of the nature of the iatrogenic radiation effect on memory by testing collateral cognitive functions that might explain the specific memory impairment. We found that the verbal-semantic recall impairment was not associated with impairments in auditory attention, auditory processing speed, auditory-verbal working memory, or in the temporal coding or subjective organization of word-list recall. These findings focus damaging radiation effects on primary retrievalprocesses, rather than on earlier cognitive processes or executive processes affecting recall. Knowledge of the specific patterns of change in cognition would guide the differential diagnosis and rehabilitation of survivors of brain tumors whose conditions are complicated by tumors with multiple treatments.

Adult↗

Protection to +12 Gz.

BACKGROUND: The U.S. Air Force has developed +Gz-protective equipment that will provide most pilots protection to +9 Gz with minimal-to-no straining. This equipment includes a pressure breathing system called COMBAT EDGE (CE), which is currently operational, and the Advanced Technology Anti-G Suit (ATAGS), which is not yet operational. For future high-performance aircraft design it is important to know the upper limit of various protective equipment and techniques. METHODS: Six subjects were randomly exposed to a 12-cell matrix composed of +Gz and the following combinations of protective equipment at three seat-back angles (13 degrees, 30 degrees and 55 degrees from the vertical): 1) the standard CSU-13B/P anti-G suit (STD); 2) the STD suit with CE; 3) the ATAGS; and 4) the ATAGS with CE. Relaxed, followed by straining +Gz tolerance was determined using 15-s rapid onset runs to a maximum of +12 Gz. A comprehensive battery of baseline and post-exposure medical surveillance studies was performed to evaluate the medical consequences of these high +Gz exposures. RESULTS: All 6 subjects were able to achieve +12 Gz with various combinations of +Gz-protective equipment, seat-back angle, and various amounts of straining, from none to maximum. When the data were collapsed over all protective equipment there was a significant (p < 0.05) seat effect. Relaxed tolerance to ROR increased with seat-back angle from 13 degrees to 30 degrees to 55 degrees. There was also a significant protective equipment effect when the data were collapsed over all seat-back angles. CONCLUSIONS: These data confirm that effortless protection to +9 Gz is available using ATAGS/CE with the 13 degree and 30 degree seat-back angle (F-15, F-16 and F-22) and to +10.5 Gz with a 55 degree seat-back angle. Moreover, with ATAGS/CE, and a moderate degree of straining, +12 Gz is definitely achievable at 55 degrees, even with reduced anti-G suit pressure at 55 degrees. With additional straining +12 GC is also achievable at the 13 degree and 30 degree seat-back angles.

Acceleration↗

A nephelometry system for the Abbott TDx analyzer.

A self-contained light-scattering accessory carousel has been developed for the Abbott TDx fluorescence polarization analyzer, extending the instrument's capabilities to nephelometric methods of analysis, including assays for specific proteins by immunoprecipitation: IgG, IgA, IgM, and transferrin. The scattered light from a green-light-emitting diode (peak wavelength 565 nm) is measured at an angle of 37.5 degrees by the existing optical detection system of the TDx analyzer without modification of the instrument. Measurements are made at quasi-equilibrium, with sample blank correction. No sample pretreatment is required, and antigen-excess is checked automatically. CVs range from 3 to 6% (within-run) and 7 to 9%. (total). Calibration curves may be stored for at least two weeks. A nephelometric method for monitoring chromogenic reactions in the green wavelength region is also described. This method--Scattered Energy Attenuation (SEA)--has been used in preliminary experiments to measure calcium, total protein, iron, and bilirubin.

Autoanalysis↗

Using nontraditional methods to teach pediatric residents about insulin-dependent diabetes mellitus.

The purpose of this study was to examine the effect of a training experience on the attitudes and beliefs of pediatric residents concerning insulin-dependent diabetes mellitus (IDDM), persons with diabetes, and the use of a multidisciplinary team to empower patients/families. The resident training experience consisted of three days of diabetes lifestyle simulation including attending an educational program designed for newly-diagnosed patients and their families. Residents' attitudes, beliefs, and team function attitudes were measured at preinstruction, postinstruction, and 6 months following instruction. There was no significant change in beliefs about diabetes. Attitudes about persons with diabetes became more positive after the training experience, but did not continue after six months. Residents also expressed a change in team attitudes, specifically, in their acceptance of having the certified diabetes educator (CDE) nurse and the patient/family adjust insulin and manage insulin during illness.

Adult↗