PubMed Health⌕ Search

Biomedical subjects

C H Wright

Publications and source records attributed to C H Wright.

At least 19 recordsLinked to original sources

Determining laser dosimetry for consistent retinal photocoagulation.

Laser photocoagulation is used extensively by ophthalmologists to treat retinal disorders such as diabetic retinopathy, macular degeneration, and retinal tears. Currently, the procedure is performed manually and suffers from several drawbacks that a computer-assisted system could help alleviate. These drawbacks include the tedious nature of the procedure for both the patient and the physician and also the extreme criticality of the task. A system is under development that will rapidly and safely place multiple therapeutic lesions at desired locations on the retina in a matter of seconds. This system provides real-time, motion-stabilized lesion placement for typical clinical irradiation times on the order of 100 ms. Considerable work has been accomplished on stabilizing the irradiating laser on the retinal surface. Various tracking systems have been designed, prototypes implemented, and tested in vivo on laboratory animals [1]. Our efforts have most recently concentrated on developing a system to monitor lesion growth in real time and turn off the laser when the desired lesion parameters have been achieved. This subsystem employs dynamic lesion reflectance as an indirect measure of lesion depth. Our goal has been to establish a correlation between the measurable lesion reflectance parameter with the actual lesion depth. Once this correlation is established, these parameters will be used to generate a control signal for the irradiation time of the laser. The goal is to optimize the therapeutic effect, without over- or under-exposing the tissue. The result is consistent lesion formation over any part of the non-homogeneous retinal tissue.

Animals↗

Initial in vivo results of a hybrid retinal photocoagulation system.

We describe initial in vivo experimental results of a new hybrid digital and analog design for retinal tracking and laser beam control. An overview of the design is given. The results show in vivo tracking rates which exceed the equivalent of 38 degrees/s in the eye. A robotically assisted lesion pattern is created for laser surgery to treat conditions such as diabetic retinopathy and retinal breaks.

Animals↗

Deriving irradiation control parameters for laser photocoagulation on the retina.

Laser photocoagulation is used extensively by ophthalmologists to treat retinal disorders such as diabetic retinopathy and retinal breaks. Currently, the procedure is performed manually and suffers from several drawbacks that a computer-assisted system could help alleviate. Such a system is under development that will rapidly and safely place multiple therapeutic lesions at desired locations on the retina in a matter of seconds. This system provides real-time, motion-stabilized lesion placement for typical clinical irradiation times (100 ms). When performing laser photocoagulation on the retina, the dynamic reflectance of the lesion formed by the laser may be used as a control signal. Using digital filtering and estimation techniques on the sampled reflectance signal, the latency time and growth rate are determined. These parameters are used to derive a control signal for the irradiation time of the laser. The goal is to optimize the therapeutic effect, without overexposing the tissue. The result is consistent lesion formation over any part of the retina.

Laser Coagulation↗

A method to control irradiation time for laser photocoagulation of the retina--Part II.

When performing laser photocoagulation of the retina, the dynamic reflectance of the lesion formed by the laser may be used as a control signal. Using digital filter and estimation techniques on the sampled reflectance signal, the latency time and growth rate of the lesion reflectance are determined. These parameters are then used to estimate the absorption coefficient of the irradiated tissue. From these estimates, the irradiation time of the laser can be accurately determined so that optimum therapeutic effect may be obtained, without overexposing the tissue. The result is consistent lesion formation over any part of the retina. This paper is a follow up to [4] and provides details of the experimental setup and signals acquisition.

Humans↗

Hybrid tracking system for retinal photocoagulation prototype II.

Laser photocoagulation has been employed extensively by ophthalmologists to treat retinal diseases and disorders such as diabetic retinopathy, macular degeneration, and retinal tears. Treatment is a manual task requiring the physician to carefully place therapeutic lesions on the retina while avoiding critical vision anatomy. We have developed a hybrid tracking system using two retinal tracking modalities: a digital imaging-based subsystem and an analog tracking subsystem to stabilize the irradiating laser on the retina. We have also investigated a lesion parameter control subsystem to provide uniform therapeutic lesions.

Biomedical Engineering↗

A method to control irradiation time for laser photocoagulation on the retina.

When performing laser photocoagulation on the retina, the dynamic reflectance of the lesion formed by the laser may be used as a control signal. Using digital filter and estimation techniques on the sampled reflectance signal, the latency time and growth rate of the lesion reflectance are determined. These parameters are then used to estimate the absorption coefficient of the illuminated tissue. From these estimates, the irradiation time of the laser can be accurately determined so that optimum therapeutic effect may be obtained, without overexposing the tissue. The result is consistent lesion formation over any part of the retina.

Laser Coagulation↗

The development of a hybrid analog/digital retinal surgical laser system.

In the last few years the progress made in producing an integrated automated retinal surgical laser system has grown tremendously. Two different techniques have been developed in parallel: an analog and a digital system. Both the analog and digital systems are capable of tracking the retina while precisely placing lesions in desired locations. However, each system has its unique advantages and disadvantages to an automated surgical system. Current work has been conducted to integrate these two techniques to take full advantage of their unique capabilities. The goal of this research is to successfully integrate the systems to provide a better retinal surgical treatment for those individuals affected by diabetes, retinal tears, and other eye disorders.

Computers, Hybrid↗

Integration of analog and digital retinal tracking and coagulation subsystems.

Laser photocoagulation is used by ophthalmologists to treat retinal disorders such as diabetic retinopathy and retinal breaks and tears. Currently, the procedure is performed manually and suffers from several drawbacks: it often requires many clinical visits, it is very tedious for both patient and physician, the laser pointing accuracy and safety margin are limited by a combination of the physician's manual dexterity and the patient's ability to hold their eye still, and there is a wide variability in retinal tissue absorption parameters. This paper describes progress in developing a computer-assisted robotic laser system that will rapidly and safely place multiple therapeutic lesions at desired locations on the retina in a few seconds.

Analog-Digital Conversion↗

Development of an integrated automated retinal surgical laser system.

Diabetes is a serious disease that affects millions of people world wide. One of the many complications that may result from this disease is an eye disorder called diabetic retinopathy. This side effect is characterized by the leaching of fluid, mainly blood, into the retinal tissue ultimately killing the rods and cones in the area. Scientists have discovered that by occulating and destroying some of the capillaries near the infected area, further damage may be limited and further vision loss prevented. This procedure is performed on the retina by using a Continuous Wave argon laser to place a pattern of lesions that kill the rods, cones, and underlying capillaries. The "Computer Aided Laser Optics System for Ophthalmic Surgery" or CALOSOS is a system that fully integrates the placement of therapeutic retinal lesions through computer control. To date, two different sub-systems have been used to achieve the desired accuracy needed including lesion placement and depth; an all-digital system and a hybrid analog/digital system. The current tracking system that precisely controls the laser uses a wide-angle lens camera to view the whole retina. The difficulty lies in the fact that the only way to control the depth of the lesion is to measure the central reflectance. The goal of this research is to establish that there is a linear relationship between the reflectance of the lesion and the depth of the lesion when this wide-angle lens is used.

Diabetic Retinopathy↗

Digital integrated retinal surgical laser system.

The year is 2001--ophthalmic retinal surgery is now fully computer assisted. Patients arriving for scheduled treatments of diabetic retinopathy, retinal tears, or macular degeneration have their retina digitally mapped by a technician. From the retinal map, the ophthalmologist plots therapeutic lesion sites with a light pen on the computer screen that will automatically be placed by a computer controlled argon laser. The treatment only requires 100 ms per lesion placement thus reducing office calls to approximately 45 minutes freeing the ophthalmologist for other pressing cases. This paper reports on the development of a clinically significant prototype system that will help bring this scenario to fruition.

Animals↗

Hybrid retinal photocoagulation system using analog tracking.

We describe initial in vivo experimental results of a new hybrid digital and analog design for retinal tracking and laser beam control. An overview of the design is given. The results show in vivo tracking rates which exceed the equivalent of 38 degrees per second in the eye, with automated lesion pattern creation. Robotically-assisted laser surgery to treat conditions such as diabetic retinopathy and retinal breaks may soon be realized under clinical conditions with requisite safety using standard video hardware and inexpensive optical components based on this design.

Analog-Digital Conversion↗

Development of an integrated automated retinal surgical laser system.

Researchers at the University of Texas and the USAF Academy have worked toward the development of a retinal robotic laser system. The overall goal of this ongoing project is to precisely place and control the depth of laser lesions for the treatment of various retinal diseases such as diabetic retinopathy and retinal tears. Separate low speed prototype subsystems have been developed to control lesion depth using lesion reflectance feedback parameters and lesion placement using retinal vessels as tracking landmarks. Both subsystems have been successfully demonstrated in vivo on pigmented rabbits using an argon continuous wave laser. Preliminary testing on rhesus primate subjects have been accomplished with the CW argon laser and also the ultrashort pulse laser. Recent efforts have concentrated on combining the two subsystems into a single prototype capable of simultaneously controlling both lesion depth and placement. We have designated this combined system CALOSOS for Computer Aided Laser Optics System for Ophthalmic Surgery. Several interesting areas of study have developed in integrating the two subsystems: 1) "doughnut" shaped lesions that occur under certain combinations of laser power, spot size, and irradiation time complicating measurements of central lesion reflectance, 2) the optimal retinal field of view (FOV) to achieve both tracking and lesion parameter control, and 3) development of a hybrid analog/digital tracker using confocal reflectometry to achieve retinal tracking speeds of up to 100 dgs. This presentation will discuss these design issues of this clinically significant prototype system. Details of the hybrid prototype system are provided in "Hybrid Eye Tracking for Computer-Aided Retinal Surgery" at this conference. The paper will close with remaining technical hurdles to clear prior to testing the full-up clinical prototype system.

Animals↗

Hybrid eye tracking for computer-aided retinal surgery.

We describe initial results of a new hybrid digital and analog design for tracking the retina and controlling the laser beam. The results demonstrate tracking rates which exceed the equivalent of 50 degrees per second in the eye, with automatic lesion pattern creation and robust loss of lock detection. Robotically-assisted laser surgery to treat conditions such as diabetic retinopathy, macular degeneration, and retinal tears can now be realized under clinical conditions with requisite safety using standard video hardware and inexpensive optical components.

Eye Movements↗

Automated retinal robotic laser system.

Researchers at the University of Texas and the USAF Academy have worked toward the development of a retinal robotic laser system. The overall goal of this ongoing project is to precisely place and control the depth of laser lesions for the treatment of various retinal diseases such as diabetic retinopathy and retinal tears. Separate low speed prototype subsystems have been developed to control lesion depth using lesion reflectance feedback parameters and lesion placement using retinal vessels as tracking landmarks. Both subsystems have been successfully demonstrated in vivo on pigmented rabbits using an argon continuous wave laser. Recent efforts have concentrated on combining the two subsystems into a single prototype capable of simultaneously controlling both lesion depth and placement. We have designated this combined system CALOSOS for Computer Aided Laser Optics System for Ophthalmic Surgery. Following the dual-use concept, this system is being adapted for clinical use as a retinal treatment system as well as a research tool for military laser-tissue interaction studies.

Animals↗

Diastematomyelia: prenatal ultrasonic appearances.

Four cases of in-utero diastematomyelia are presented and the ultrasonic features described. Characteristic findings are localised widening of the posterior ossification centres with a central echogenic focus at the point of widening, visible on coronal scanning, and absence of a posterior defect or soft tissue mass on transverse scanning. The aetiology and management of the condition is discussed. The cases illustrate that widening of the posterior ossification centres can occur in the absence of overt spina bifida and the prenatal detection of diastematomyelia will allow for early postnatal investigation and treatment.

Female↗

Obstetric care in a health maintenance organization and a private fee-for-service practice: a comparative analysis.

This study compares the quality of obstetric care provided for patients in two distinct groups: a federally-qualified health maintenance organization and a private fee-for-service practice. Patients of both groups were delivered in the same hospital with resident coverage equally accessible to both groups. From January, 1979, through December, 1981, the period of the study, the physician group delivered 2385 patients, 57% of them from the health maintenance organization and 43% from the fee-for-service practice. Not only were comparisons of maternal and fetal outcomes available for the two patient groups, but the yearly trends and individual performances of the physicians were available as well. This paper addresses the question, all other things being equal, is the level of care and ultimate outcome the same for both groups of patients? The results in some instances showed surprising differences.

Adult↗