PubMed Health⌕ Search

Biomedical subjects

C H de Verdier

Publications and source records attributed to C H de Verdier.

At least 73 records · Page 4Linked to original sources

Plasma concentration and renal excretion of adenine and 2,8-dihydroxyadenine after administration of adenine in man.

A new method of high performance liquid chromatography (HPLC) which makes it possible to analyse 2,8-dihydroxyadenine (DOA) in plasma in concentrations exceeding 0.25 mumol/l is described. The method was used to study the renal elimination of DOA. For comparison, the renal handling of adenine was also investigated. The results from an analysis of the experimental data support the assumption that more than one concentration-dependent mechanism exists in the renal tubuli for each of the two purines, adenine and DOA. In general the clearance values are higher for DOA than for adenine and indicate net secretion for both substances.

Adenine↗

Pancreatic iso-amylase in serum as a diagnostic test in different clinical situations. A simulation study.

The potential use of a pancreatic iso-amylase test has been studied by computer simulation. This simulation was performed to assess the quality requirements on the test in different clinical situations. It was shown that, in most situations studied, an optimal discriminating level and an optimal analytical quality (imprecision and bias) could be established. In one situation studied in more detail, it was found that the influence of pre-analytical variation, duplicate determinations, reclassification of borderline cases and size of reference sample groups were of minor importance. The weighting ratio of false negatives: false positives was found to be critical for the results. It is concluded that a simulation study of this type can be recommended prior to entering the phases of analytical refinement and clinical testing on patients.

Adult↗

Preservation of red blood cells with purines and nucleosides. I. Changes of ATP, 2,3-P2G and further parameters of metabolism in red cells stored as whole blood and as resuspension at 4 degrees C and 25 degrees C.

CPD blood with addition of adenine in 0.25 mM final concentration alone or in combination with guanosine and inosine each in 0.5 mM concentration and also with a higher adenine concentration--0.75 mM--was stored 6 weeks at 4 degrees C. In a second experiment red cell concentrates were prepared from CPD blood and resuspended in the same volume of a glucose-sucrose-citrate solution with the addition of adenine or guanine and both in combination with inosine. The resuspended cells were stored 7 days at 25 degrees C. Adenine and guanosine added simultaneously were most effective on the maintenance of ATP and P2G content. When guanosine was replaced by the same amount of inosine, no effect on P2G content was found in comparison with the addition of only adenine, however, the ATP content decreased more rapidly. The reason for this difference can be due to a different affinity of the IMP/GMP: pyrophosphate phosphoribosyltransferase to their substrates as well as regulation principles in the P2G bypass. The guanosine effect on red cell preservation consists in improved viability of red cells in vivo, increased nucleotide synthesis, increased formation of 2.3-P2G, delayed disc-spher transformation of red cells and decreased hemolysis. The most effective solution for red cell preservation should contain adenine, a pentose moiety like guanosine, and inorganic phosphate in a final concentrations in blood of 0.25 : 0.5 : 2 mM. The preparation of red cell concentrates from CPD-AG or CPD-A blood requires an elevation of glucose concentration in blood above 30 mM for storage periods up to 5--6 weeks.

2,3-Diphosphoglycerate↗

Preservation of red blood cells with purines and nucleosides. II. Uptake and utilization of purines and nucleosides by stored red blood cells.

The uptake of adenine, guanine, guanosine and inosine by stored red cells was investigated in whole blood and red cell resuspensions at initial concentrations of 0.25, 0.5 and 0.75 mM for adenine and 0.5 mM for the other additives using a rapid ion-exchange chromatographic microanalysis of purines and nucleosides in plasma and whole blood. Increasing adenine concentrations from 0.25 to 0.75 mM in blood elevated the adenine uptake from 0.3 up to 0.8 mmol/l red cells during 2 hours after collecting blood. The intra-/extracellular distribution ratio changed from 1 : 1.3 to 1: 1.7. Some 2 hours after withdrawing blood into CPD--solution with purines and nucleosides the uptake of adenine and guanine resulted in 40 per cent and 70 per cent respectively and of guanosine and inosine in 80 and 90 per cent respectively. The replacement of plasma by a resuspending solution gave the same uptake rates for purines and nucleosides. The nucleosides were rapidly split to purines and R-1-P and disappeared from blood during one week. Adenine and guanine were utilized to 80 to 90 per cent only after 3 weeks. During the same period the utilization of guanine was smaller by 40 per cent than that of adenine due to the different activity of the purine nucleoside phosphorylase for these substrates. The plasma of all analyzed blood samples contained hypoxanthine and inosine, but guanine and guanosine were detected only in those samples to which one of them was added. After 3 weeks of storage the highest concentration of hypoxanthine was found in CPD-AI blood with 600 microM in plasma and the highest concentration of synthesized inosine in CPD-AG blood with a concentration of 100 microM in plasma. Three ways of utilization of purines by stored red cells were discussed : the synthesis of nucleotide monophosphates, the formation of nucleosides, and the deamination. The portions of these ways change during storage. The most effective concentrations of adenine and guanosine in stored blood seems to be 0.25 and 0.5 mM respectively. The full utilization of the nucleoside requires the addition of inorganic phosphate.

Adenine↗

Adenine metabolism in man. 1. After intravenous and peroral administration.

The basal plasma concentration of adenine and its renal excretion was studied in two men. For its analysis partly new chromatographic techniques were developed. The plasma concentration varied around 70 nmol/l; the renal excretion rate was, as reported earlier by other investigators, around 10 nmol/min. Loadings, intravenously during about 3 h and orally, both with about 30 nmol adenine per kg body mass revealed that most of the adenine was metabolized to nucleotide form. In the experiments with intravenous administration of adenine only about 2% of the given dose appeared in the urine as adenine and somewhat less as the easily precipitable metabolite 2,8-dihydroxyadenine. In the peroral loads, with higher plasma adenine concentrations, the ratios of the renally excreted two compounds were one to a few per cent higher.

Adenine↗

Thermodynamics of red cell glycolysis.

1. Changes of Gibbs energy, enthalpy and entropy in red cells during steady-state glycolysis were discussed. 2. The heat production of red cells at various metabolic conditions was measured on a flow microcalorimeter with simultaneous analyses of lactate and other metabolites. The results were discussed in relation to enthalpy changes of the different metabolic steps in the glycolytic pathway.

Adenosine Triphosphate↗

Performance characteristics of rules for internal quality control: probabilities for false rejection and error detection.

When assessing the performance of an internal quality control system, it is useful to determine the probability for false rejections (pfr) and the probability for error detection (ped). These performance characteristics are estimated here by use of a computer stimulation procedure. The control rules studied include those commonly employed with Shewhart-type control charts, a cumulative sum rule, and rules applicable when a series of control measurements are treated as a single control observation. The error situations studied include an increase in random error, a systematic shift, a systematic drift, and mixtures of these. The probability for error detection is very dependent on the number of control observations and the choice of control rules. No one rule is best for detecting all errors, thus combinations of rules are desirable. Some appropriate combinations are suggested and their performance characteristics are presented.

Chemistry, Clinical↗

Combined Shewhart-cusum control chart for improved quality control in clinical chemistry.

We describe the adaptation of the decision limit cumulative sum method (cusum) to internal quality control in clinical chemistry. With the decision limit method, the cusum is interpreted against a numerical limit, rather than by use of a V-mask. The method can be readily implemented in computerized quality-control systems or manually on controls charts. We emphasize the manual application here and demonstrate how the technique can be implemented on existing Shewhart or Levey-Jennings control charts. This permits both cusum and Shewhart control rules to be used simultaneously on a single control chart and also minimizes the data calculations necessary for the cusum method. Computer simulation studies are used to determine the performance characteristics of several different cusum rules, alone and in combination with a Shewhart rule. These studies indicate that improvements in existing quality-control systems should be possible by addition of this simple cusum method and by use of a combined Shewhart-cusum control chart. This should be particularly advantageous when introducing the cusum method in laboratories with manual quality-control systems.

Chemistry, Clinical↗

Calorimetric study on human erythrocyte glycolysis. Heat production in various metabolic conditions.

The heat production of human erythrocytes was measured on a flow microcalorimeter with simultaneous analyses of lactate and other metabolites. The heat production connected with the lactate formation was about 17 kcal (71 kJ) per mol lactate formed which corresponded to the sum of heat production due to the formation of lactate from glucose and the heat production due to neutralization. The heat production rate increased as the pH of the suspension increased, corresponding to the increase in lactate formation. Glycolytic inhibitors such as fluoride and monoiodoacetate caused a decrease in the rate of heat production, whereas arsenate induced a large transient increase in heat production associated with a transient increase in lactate formation. Decrease in pyruvate concentration was usually associated with increase in heat production, although the decreased pyruvate concentration was coupled with formation of 2,3-bisphosphoglycerate. When inosine, dihydroxyacetone or D-glyceraldehyde was used as a substrate, an increase in the heat production rate was observed. Addition of methylene blue caused an oxygen uptake which was accompanied by a remarkable increase in heat production rate corresponding to about 160 kcal (670 kJ) per mol oxygen consumed. The value for heat production in red cells in the above-mentioned metabolic conditions was considered in relation to earlier known data on free energy and enthalpy changes of the different metabolic steps in the glycolytic pathway.

Arsenates↗