PubMed Health⌕ Search

Biomedical subjects

C Hedgepeth

Publications and source records attributed to C Hedgepeth.

3 recordsLinked to original sources

Tinnitus suppression in patients with cochlear implants.

OBJECTIVE: To determine the degree of tinnitus suppression provided by currently available multichannel cochlear implants and to determine factors that can influence this process. STUDY DESIGN: Prospective cohort. SETTING: Tertiary-care referral center. PATIENTS: Thirty-eight adult patients (18 years of age or older) with severe-to-profound hearing loss and tinnitus who met criteria for cochlear implantation. INTERVENTION: Cochlear implantation with a multichannel cochlear implant device. MAIN OUTCOME MEASURES: Patients rated the intensity of their tinnitus using a semiquantitative scale before and after cochlear implantation. These data were analyzed to determine the significance of the reduction of tinnitus after implantation. Tinnitus levels after implantation were also analyzed to determine whether the level of speech recognition, patient gender, or the implant type influenced the degree of tinnitus reduction. RESULTS: Statistical analysis revealed a significant reduction in tinnitus intensity in patients using cochlear implants, with 35 of 38 patients (92%) experiencing a reduction in tinnitus intensity. All multichannel implants studied afforded similar degrees of tinnitus suppression. The degree of tinnitus reduction was not correlated with speech recognition, as measured by CID Everyday Sentence scores. Female patients had significantly greater degrees of tinnitus before implantation, but both male and female patients demonstrated similar levels of tinnitus after implantation. No patient experienced greater levels of tinnitus after implantation. CONCLUSION: All currently available multichannel cochlear implant devices provide effective and similar levels of tinnitus suppression when activated. Exacerbation of tinnitus as a result of cochlear implantation does not represent a significant risk. The mechanisms by which cochlear implants exert tinnitus suppression are, as yet, unclear.

Adult↗

Polyethylene glycol enhanced refolding of bovine carbonic anhydrase B. Reaction stoichiometry and refolding model.

Polyethylene glycol (PEG) inhibited aggregation during refolding of bovine carbonic anhydrase B (CAB) through the formation of a nonassociating PEG-intermediate complex. Stoichiometric concentrations of PEG were required for complete recovery of active protein during refolding at aggregating conditions. For example, a PEG (Mr = 3350) to CAB molar ratio ([PEG]/[CAB]) of 2 was sufficient to inhibit aggregation during refolding at 1.0 mg/ml (33.3 microM) protein and 0.5 M guanidine hydrochloride. In addition, the PEG concentration required for enhancement was dependent upon the molecular weight and only molecular weights between 1000 and 8000 were effective in inhibiting aggregation. In the presence of PEG, the rate of refolding was the same as that observed for refolding without the formation of associated species. Refolding in the presence of PEG resulted in the rapid formation of a PEG complex with the molten globule first intermediate, and this PEG-intermediate complex did not aggregate. The CAB refolding kinetics in the presence of PEG were determined and used to develop a model of the PEG enhanced refolding pathway. The mathematical model was validated by independent activity measurements of CAB refolding. This model predicted that PEG enhanced refolding of CAB occurred by a specific interaction of PEG with the molten globule first intermediate to form a nonassociating complex which continued to fold at the same rate as the first intermediate. The predicted pathway and binding properties of PEG indicate that PEG enhanced refolding may be analogous to chaperonin mediated protein folding.

Animals↗