PubMed Health⌕ Search

Biomedical subjects

C Heiner

Publications and source records attributed to C Heiner.

4 recordsLinked to original sources

Long-range sequence analysis in Xq28: thirteen known and six candidate genes in 219.4 kb of high GC DNA between the RCP/GCP and G6PD loci.

DNA comprising 219 447 bp was sequenced in nine cosmids and verified at > 99.9% precision. Of the standard repetitive elements, 187 Alus make up 20.6% of the sequence, but there were only 27 MERs (2.9%) and 17 L1 fragments (1.6%). This may be characteristic of such high GC (57%) regions. The sequence also includes an 11.3 kb tract duplicated with 99.2% identity at a distance of 38 kb. The region is 80-90% transcribed and 12.5% translated. Thirteen known genes and their exon-intron borders are all accurately predicted at least in part by GRAIL programs, as are six additional genes. From centromere to telomere, the orientation of transcription varies among the first eight genes, then runs centromeric to telomeric for the next five, and is in the opposite sense for the last six. Eighteen of the 19 genes are associated with CpG islands. Two islands are exact copies in the 11.3 kb repeat units, and could thus give rise to double dosage levels of an X-linked gene. Another island is associated with two genes transcribed in opposite directions. From the sequence data, three genes and their exon structure are inferred. One of them, previously associated with HEX2, is shown to be a different gene unrelated to hexokinases; a second gene, previously known by an EST, is plexin, from its 65.5% identity with the Xenopus analog; and a third is a subunit of a vacuolar H-ATPase, and is named VATPS1.

Base Sequence↗

Rapid and reliable fluorescent cycle sequencing of double-stranded templates.

Automated DNA sequencing is an extremely valuable technique which requires very high quality DNA templates to be carried out successfully. While it has been possible to readily produce large numbers of such templates from M13 or other single-stranded vectors for several years, the sequencing of double-stranded DNA templates using the ABI 373 DNA Sequencer has had a considerably lower success rate. We describe how the combination of a new fluorescent, dideoxy sequencing method, called cycle-sequencing, coupled with modifications to template isolation procedures based on Qiagen columns, makes fluorescent sequencing of double-stranded templates a reliable procedure. From a single five milliliter culture enough DNA can be isolated (up to 20 micrograms) to do 4-8 sequencing reactions, each of which yields 400-500 bases of high quality sequence data. These procedures make the routine use of double-stranded DNA templates a viable strategy in automated DNA sequencing projects.

Base Sequence↗

Fluorescence detection in automated DNA sequence analysis.

We have developed a method for the partial automation of DNA sequence analysis. Fluorescence detection of the DNA fragments is accomplished by means of a fluorophore covalently attached to the oligonucleotide primer used in enzymatic DNA sequence analysis. A different coloured fluorophore is used for each of the reactions specific for the bases A, C, G and T. The reaction mixtures are combined and co-electrophoresed down a single polyacrylamide gel tube, the separated fluorescent bands of DNA are detected near the bottom of the tube, and the sequence information is acquired directly by computer.

Automation↗