Hybrid cardiac imaging with MR-CAT scan: a feasibility study.

We demonstrate the feasibility of a new versatile hybrid imaging concept, the combined acquisition technique (CAT), for cardiac imaging. The cardiac CAT approach, which combines new methodology with existing technology, essentially integrates fast low-angle shot (FLASH) and echoplanar imaging (EPI) modules in a sequential fashion, whereby each acquisition module is employed with independently optimized imaging parameters. One important CAT sequence optimization feature is the ability to use different bandwidths for different acquisition modules. Twelve healthy subjects were imaged using three cardiac CAT acquisition strategies: a) CAT was used to reduce breath-hold duration times while maintaining constant spatial resolution; b) CAT was used to increase spatial resolution in a given breath-hold time; and c) single-heart beat CAT imaging was performed. The results obtained demonstrate the feasibility of cardiac imaging using the CAT approach and the potential of this technique to accelerate the imaging process with almost conserved image quality.

Coronary Vessels↗

High-resolution diffusion imaging using a radial turbo-spin-echo sequence: implementation, eddy current compensation, and self-navigation.

This work describes a segmented radial turbo-spin-echo technique (DW-rTSE) for high-resolution multislice diffusion-weighted imaging and quantitative ADC mapping. Diffusion-weighted images with an in-plane resolution of 700 microm and almost free of bulk motion can be obtained in vivo without cardiac gating. However, eddy currents and pulsatile brain motion cause severe artifacts when strong diffusion weighting is applied. This work explains in detail the artifacts in projection reconstruction (PR) imaging arising from eddy currents and describes an effective eddy current compensation based on the adjustment of gradient timing. Application of the diffusion gradients in all three orthogonal directions is possible without degradation of the images due to eddy current artifacts, allowing studies of the diffusional anisotropy. Finally, a self-navigation approach is proposed to reduce residual nonrigid body motion artifacts. Five healthy volunteers were examined to show the feasibility of this method.

Anisotropy↗

MR CAT scan: a modular approach for hybrid imaging.

In this study, a modular concept for NMR hybrid imaging is presented. This concept essentially integrates different imaging modules in a sequential fashion and is therefore called CAT (combined acquisition technique). CAT is not a single specific measurement sequence, but rather a sequence design concept whereby distinct acquisition techniques with varying imaging parameters are employed in rapid succession in order to cover k-space. The power of the CAT approach is that it provides a high flexibility toward the acquisition optimization with respect to the available imaging time and the desired image quality. Important CAT sequence optimization steps include the appropriate choice of the k-space coverage ratio and the application of mixed bandwidth technology. Details of both the CAT methodology and possible CAT acquisition strategies, such as FLASH/EPI-, RARE/EPI- and FLASH/BURST-CAT are provided. Examples from imaging experiments in phantoms and healthy volunteers including mixed bandwidth acquisitions are provided to demonstrate the feasibility of the proposed CAT concept.

Abdomen↗

Signal intensities in FLASH-EPI-hybrid sequences.

Theoretical considerations on the signal-to-noise ratio (SNR) in FLASH-EPI-Hybrid imaging were published previously. The purpose of this work was to investigate in vivo the signal intensities in Hybrid images as a function of sequence specific parameters. In detail, the SNR as a function of the number of echoes m per RF excitation, the excitation flip angle alpha, and the dependence on the tissue relaxation times T1 and T2* were studied. In eight healthy subjects brain and abdominal Hybrid images were acquired where m and alpha were changed independently. Signal intensities in human brain, liver, and kidney were evaluated for each Hybrid experiment. Additionally, T1 and T2* values of these tissue types were quantified to allow for a comparison with the theory. An excellent agreement between calculated and measured signal behavior was found. The theory was therefore validated in vivo and can thus be used to optimize the signal-to-noise in Hybrid experiments.

Brain↗

Quantitative magnetic resonance imaging of capillary water permeability and regional blood volume with an intravascular MR contrast agent.

A novel method is presented to simultaneously measure the permeability surface area product of water (PS), also known as capillary diffusion capacity, and the regional blood volume (RBV). It is based on magnetic resonance imaging of the longitudinal relaxation times of tissue and blood at different concentrations of an intravascular MR contrast agent. PS and RBV were measured in vivo in different regions of the brain and the skeletal muscle of the rat. The average PS values (n = 5) obtained in cerebral cortex, corpus callosum, hippocampus, thalamus, jaw muscle, and tongue muscle were 3.31 +/- 0.20, 1.81 +/- 0.25, 3.37 +/- 0.36, 3.68 +/- 0.44, 10.6 +/- 1.1, and 14.1 +/- 2.51 ml x min(-1) x g(-1), respectively. The corresponding average RBV values were 1.63 +/- 0.18, 1.22 +/- 0.25, 3.30 +/- 0.37, 3.03 +/- 0.36, 1.66 +/- 0.30, and 1.38 +/- 0.33 ml x 100 g(-1). These results are in good agreement with previously reported literature values obtained by means of autoradiography.

Animals↗