PubMed Health⌕ Search

Biomedical subjects

C Ince

Publications and source records attributed to C Ince.

At least 37 records · Page 2Linked to original sources

Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation.

Orthogonal polarization spectral (OPS) imaging is a new clinical technique for observation of the microcirculation of organ surfaces. For validation purposes, we compared OPS images of the nailfold skin with those obtained from conventional capillary microscopy at rest and during venous occlusion in 10 male volunteers. These images were computer analyzed to provide red blood cell velocity and capillary diameters of the same nailfold capillaries at rest and during venous occlusion. Results showed that OPS images provided similar values for red blood cell velocity and capillary diameter as those obtained from capillary microscopy images. OPS imaging, however, provided significantly better image quality, as shown by comparison of image contrast between OPS imaging and capillary microscopy. This made image analysis better and easier to perform. It is anticipated, therefore, that OPS imaging will become a new and powerful technique in the study of the human microcirculation in vivo because it can be used on human internal organs.

Adult↗

The Laser-assisted Optical Rotational Cell Analyzer (LORCA) as red blood cell aggregometer.

The Laser-assisted Optical Rotational Cell Analyzer (LORCA) is unique in its capacity to measure at least two important hemorheological parameters, i.e., deformability of red blood cells (RBC) as well as their aggregation behaviour. In this communication the main principles and characteristics of the aggregometer mode of this instrument are described. Via syllectometry (i.e., laser backscatter versus time), the method allows the measure of both static and kinetic parameters of the aggregation process, e.g., total extent of aggregation, aggregation half time and a combination of these, defined as aggregation index. When the syllectogram deviates from that representing normal rouleaux formation, e.g., in the case of RBC clump formation, this is signalled by a fit error. Maximal flexibility is obtained by various options like an automated re-iteration procedure (which enables to measure the aggregation tendency and/or the aggregate stability) and aggregation at low shear rate. Experiments dealing with reproducibility, stability and sensitivity of the instrument are described. The latter include a few "classic" methods for inducing subtle changes in RBC aggregation behaviour both regarding cellular factors (heat treatment) and changes in medium constituents (fibrinogen, dextrans).It can be concluded that the aggregometer mode of the LORCA considerably increases the feasibility of this instrument for hemorheological investigations.

Cryoglobulinemia↗

Mouse models of focal arterial and venous thrombosis.

Mouse models of arterial and venous thrombosis have gained increasing interest over the last 15 years, due to direct availability of a growing number of genetically modified mice, improved technical feasibility, standardization of new models of local thrombosis, and low maintenance costs. In order to provide an overview of suitable models for the study of arterial and venous thrombosis in mice, we have systematically searched MEDLINE electronic databases for publications reporting on murine thrombo-embolic models from 1966-1999. We found that the variety of murine thromboembolic models through 1995 was rather limited, as most methods used intravenous injections of strong coagulation triggers such as thrombin, thromboplastin and collagen, causing lethal thromboembolism. Between 1996 and the end of 1999, a number of more sophisticated murine models of local acute or chronic thrombosis have been established. They seem to be more suitable for mimicking the natural scenario of thrombosis and, therefore, are preferable models for pathophysiological or drug evaluation studies. In this paper various models are described and their advantages and limitations discussed.

Animals↗

Mechanical ventilation of mice.

Due to growing interest in murine functional genomics research, there is an increasing need for physiological stable in vivo murine models. Of special importance is support and control of ventilation by artificial respiration, which is difficult to execute as a consequence of the small size of the animal and the technically demanding breathing pattern. In addition, numerous genetically altered mice show depressed spontaneous ventilation or impaired respiratory responses. After an introduction in murine respiratory physiology we describe options for ventilatory support, its monitoring and the potential side effects. This review will provide an overview on current possibilities in the field of airway support in mouse research.

Aging↗

Preservation of intestinal microvascular Po2 during normovolemic hemodilution in a rat model.

The effect of hemodilution on the intestinal microcirculatory oxygenation is not clear. The aim of this study was to determine the effect of moderate normovolemic hemodilution on intestinal microvascular partial oxygen pressure (Po2) and its relation to the mesenteric venous Po2 (Pmvo2). Normovolemic hemodilution was performed in 13 anesthetized male Wistar rats. Systemic hemodynamic and intestinal oxygenation parameters were monitored. Intestinal microvascular Po2 was measured by using the oxygen-dependent quenching of palladium-porphyrin phosphorescence. Hemodilution decreased systemic hematocrit from 45.0% +/- 0.1% (average +/- SEM) to 24.6% +/- 1.6%. The mesenteric blood flow did not change from baseline values, resulting in a linear decrease in intestinal oxygen delivery (from 2.77 +/- 0.15 to 1.42 +/- 0.11 mLxkg(-1)xmin(-1)). The intestinal oxygen extraction ratio increased significantly from 24% +/- 1% to 42% +/- 4%. Pmvo2 decreased significantly (from 57 +/- 2 to 41 +/- 2 mm Hg), but intestinal oxygen consumption and microvascular Po2 remained unaffected. As a result, the difference between microvascular Po2 and Pmvo2 increased significantly during hemodilution. Intestinal microvascular Po2 and oxygen consumption were well preserved during moderate normovolemic hemodilution. These results might be explained by the notion of others that hemodilution induces recruitment of capillaries, resulting in redistribution of the intestinal blood flow in favor of the microcirculation, which allows a more efficient extraction of oxygen. These findings further indicate that the use of venous Po2 values as indicators of microvascular oxygenation may be misleading.

Animals↗

Microvascular oxygen pressure in the pig intestine during haemorrhagic shock and resuscitation.

1. The aim of this study was to investigate the relation between microvascular and venous oxygen pressures during haemorrhagic shock and resuscitation in the pig intestine. To this end microvascular PO2 (microPO2) was measured by quenching of Pd-porphyrin phosphorescence by oxygen and validated for the intestines. In addition, mesenteric venous blood gasses, blood flow, ilial CO2 production and global haemodynamics were also measured. 2. In one group (n = 11), moderate shock was induced by withdrawal of 40% of the circulating blood volume. Seven of these animals were resuscitated with a crystalloid solution and four with the withdrawn blood. In a second group of three animals, a more severe shock was induced by withdrawal of 50% of the circulating blood volume; these animals were not resuscitated. 3. Baseline mesenteric venous PO2 and microPO2 values were similar (60 +/- 9 and 60 +/- 11 mmHg, respectively). During moderate shock, microPO2 dropped significantly below mesenteric venous PO2 (26 +/- 10 versus 35 +/- 8 mmHg). After resuscitation with crystalloid solution, microPO2 and mesenteric venous PO2 rose to 44 +/- 9 and 44 +/- 6 mmHg, respectively. In the group that received the withdrawn blood, values were 41 +/- 9 and 53 +/- 12 mmHg, respectively. Severe shock resulted in a drop in the mesenteric venous PO2 (n = 3) to a value similar to that seen in the moderate shock group, but the gut microPO2 dropped to a much lower value than that of the moderate shock group (15 +/- 5 versus 26 +/- 10 mmHg). 4. The results indicate that the oxygenation of the microcirculation of the gut can become lower than the venous PO2 under conditions of haemorrhagic shock.

Animals↗

Functional heterogeneity of oxygen supply-consumption ratio in the heart.

In this review, the regional heterogeneity of the oxygen supply-consumption ratio within the heart is discussed. This is an important functional parameter because it determines whether regions within the heart are normoxic or dysoxic. Although the heterogeneity of the supply side of oxygen has been primarily described by flow heterogeneity, the diffusional component of oxygen supply should not be ignored, especially at high resolution (tissue regions << 1 g). Such oxygen diffusion does not seem to take place from arterioles or venules within the heart, but seems to occur between capillaries, in contrast to data recently obtained from other tissues. Oxygen diffusion may even become the primary determinant of oxygen supply during obstructed flow conditions. Studies aimed at modelling regional blood flow and oxygen consumption have demonstrated marked regional heterogeneity of oxygen consumption matched by flow heterogeneity Direct, non-invasive indicators of the balance between oxygen supply and consumption include NADH videofluorimetry (mitochondrial energy state) and microvascular PO2 measurement by the Pd-porphyrin phosphorescence technique. These indicators have shown a relatively homogeneous distribution during physiological conditions supporting the notion of regional matching of oxygen supply with oxygen consumption. NADH videofluorimetry, however, has demonstrated large increases in functional heterogeneity of this ratio in compromised hearts (ischemia, hypoxia, hypertrophy and endotoxemia) with specific areas, referred to as microcirculatory weak units, predisposed to showing the first signs of dysoxia. It has been suggested that these weak units show the largest relative reduction in flow (independent of absolute flow levels) during compromising conditions, with dysoxia initially developing at the venous end of the capillary.

Animals↗

Microcirculatory oxygenation and shunting in sepsis and shock.

OBJECTIVE: To review optical spectroscopic techniques for assessment of the determinants of tissue oxygenation and to evaluate the notion that the disturbances in oxygen pathways in sepsis can be accounted for by enhanced functional shunting of parts of the microcirculation. DATA RESOURCES: Experimental data from previous research and the literature were analyzed. STUDY SELECTION: The data selected pertained to a) whether cellular distress in sepsis is caused by tissue hypoxia or disturbed metabolic pathways, b) optical spectroscopic techniques used to study microcirculatory oxygenation, and c) possible mechanisms underlying shunting of the microcirculation in hypoxemia and sepsis. STUDY SYNTHESIS: Despite resuscitation of oxygen-derived variables, signs of regional tissue hypoxia persist in sepsis. The mechanisms underlying this condition are expected to be associated with oxygen pathways in the microcirculation. Optical spectroscopic techniques are providing new insights into these mechanisms. These include absorption spectroscopy for hemoglobin saturation of erythrocytes, reduced nicotinamide adenine dinucleotide fluorescence for tissue mitochondrial bioenergetics, and palladium-porphyrin phosphorescence for microvascular PO2. Reduced nicotinamide adenine dinucleotide videofluorescence studies have shown the heterogeneous nature of hypoxia. Measurement of gut microvascular PO2 in pigs has shown the development of a PO2 gap between microvascular PO2 and venous PO2 during hemorrhage and endotoxemia, with a larger gap occurring in sepsis than in hemorrhage. It is hypothesized that this difference is caused by the enhanced shunting of the microcirculation present in sepsis. CONCLUSIONS: Microcirculatory distress may form one of the earliest stages in the progress of sepsis to multiple organ failure, and shunting of the microcirculation may be an important contributing factor to this development. To evaluate the severity of microcirculatory distress and the effectiveness of resuscitation strategies, new clinical technologies aimed at the microcirculation will need to be developed. It is anticipated that optical spectroscopy will play a major role in the development of such tools.

Humans↗

PO2 measurements in the rat intestinal microcirculation.

Microvascular partial oxygen pressure (PO2) data measured with the quenched phosphorescence of palladium-porphyrin (Pd-porphyrin) with the use of optical fibers have provided new insight into the behavior of the microvascular oxygenation in models of shock. However, the actual microcirculatory compartment measured by this fiber technique has not yet been demonstrated. The purpose of this study was to investigate whether the PO2 of the intestines, as measured using a fiber phosphorometer, reflects the microvascular compartment. To this end, a new intravital phosphorometer with an improved sensitivity to high-PO2 levels (up to 180 mmHg) was developed and validated. With this setup, PO2 values were measured at different inspired oxygen fractions (15, 25, and 50% oxygen) in first-order arterioles, capillaries, and venules of the ileum of rats. Simultaneously, the PO2 was measured with an optical fiber attached to another phosphorometer. PO2 measurements with the fiber phosphorometer show excellent correlation with the PO2 in the capillaries and first-order venule vessels (r2 = 0.94, slope 0.99). We therefore conclude that values measured with the fiber phosphorometer correlate with the capillary and venular PO2.

Animals↗

Regional ischemia in hypertrophic Langendorff-perfused rat hearts.

Myocardial hypertrophy decreases the muscle mass-to-vascularization ratio, thereby changing myocardial perfusion. The effect of these changes on myocardial oxygenation in hypertrophic Langendorff-perfused rat hearts was measured using epimyocardial NADH videofluorimetry, whereby ischemic myocardium displays a high fluorescence intensity. Hypertrophic hearts, in contrast to control hearts, developed ischemic areas during oxygen-saturated Langendorff perfusion. Reoxygenation of control hearts after a hypoxic episode resulted in a swift decrease of fluorescence in a heterogeneous pattern of small, evenly dispersed, highly fluorescent patches. Identical patterns could be evoked by occluding capillaries with microspheres 5.9 micrometer in diameter. Ten seconds after reoxygenation there were no more dysoxic areas, whereas reoxygenation in hypertrophic hearts showed larger ischemic areas that took significantly longer to return to normoxic fluorescence intensities. Hypothesizing that the larger areas originate at a vascular level proximal to the capillary network, we induced hypoxic patterns by embolizing control hearts with microspheres 9.8 and 15 micrometer in diameter. The frequency distribution histograms of these dysoxic surface areas matched those of hypertrophic hearts and differed significantly from those of hearts embolized with 5.9-micrometer microspheres. These results suggest the existence of areas in hypertrophic Langendorff-perfused hearts with suboptimal vascularization originating at the arteriolar and/or arterial level.

Animals↗

Clinical potential of in vitro measured red cell deformability, a myth?

For many years the study of Red Blood Cell (RBC) deformability has been limited to specialised hematological research institutes and this has hampered a widespread clinical testing of this dynamic RBC property. Consequently, the clinical relevance of such in vitro measurements has remained questionable now for a considerable time. The recent availability of the LORCA, a routinely applicable and computer assisted instrument for this purpose, opens now the possibility to evaluate RBC deformability on a large scale in various pathological situations associated with impaired microcirculatory flow. In this communication we present our clinical experience obtained thusfar with this instrument. Besides the effect of physiological aging of normal RBC, the results of a clinical study on malaria tropica, case studies of hereditary elliptocytosis, Smith-Lemli-Opitz syndrome (a cholesterol biosynthesis defect), the treatment of sickle cell crisis with hydroxy-urea as well as the clinical intervention with Cyclosporin, are collected. In conclusion, it can be stated that the limited clinical experience with the LORCA as is reported here, yields sufficient evidence about the clinical potential of this technique.

Adult↗

NADH videofluorimetry to monitor the energy state of skeletal muscle in vivo.

BACKGROUND: Reduction of the cellular energy state during ischemia of the limbs is an important determinant for development of necrosis. Since energy conversion in the mitochondria is based on electron transport from NADH to molecular O2, the NADH/NAD+ redox couple reflects the mitochondrial redox state and cellular O2 requirement. The applicability of NADH videofluorimetry to monitor noninvasively changes in the energy state of intact resting skeletal muscle as a function of oxygenation was investigated in a rat model. MATERIALS AND METHODS: In mechanically ventilated rats (n = 6), NADH fluorescence images of the gracilis muscle were recorded under different oxygenation conditions. Induction of anoxic and ischemic hypoxia were verified by simultaneous measurement of tissue oxygen pressure and afferent blood flow. RESULTS: Anoxic hypoxia and ischemic hypoxia increased the NADH fluorescence intensity by 46.0 +/- 15.0 and 30.8 +/- 26.4%, respectively. The response time of NADH fluorescence intensity, tissue oxygen pressure, and afferent blood flow was similar during development of anoxic and ischemic hypoxia. Upon reperfusion and reoxygenation, however, NADH fluorescence intensity changed significantly earlier than tissue oxygen pressure as measured by an oxygen needle electrode. CONCLUSION: These results demonstrate that changes in NADH fluorescence intensity reflect oxygenation changes in intact skeletal muscle in vivo. Since NADH videofluorimetry, in contrast to oxygen needle electrode measurements, noninvasively visualizes temporal and regional changes in the energy state of skeletal muscle, this technique has the potential to improve clinical evaluation of ischemia/reperfusion injury and tissue viability.

Animals↗

A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings.

OBJECTIVE: The purpose of this study was to assess and compare the humidification, heating, and resistance properties of three commercially available heat-moisture exchangers (HMEs). To mimic clinical conditions, a previously validated, new, realistic experimental set-up and measurement protocol was used. DESIGN: Prospective, comparative experimental study. SETTING: Surgical Intensive Care Unit, University Hospital of Rotterdam. MATERIALS: An experimental set-up consisting of a patient model, measurement systems, and ventilator and three different HME types. INTERVENTIONS: The air flow, pressure in the ventilation circuit, pressure difference over the HME, and partial water vapour pressure and temperature at each side of the HMEs were measured. Measurements were repeated every 30 min during the first 2 h and every hour up to 24 h for each HME at six different ventilator settings. The mean inspiratory and maximum expiratory resistance, flow-weighted mean absolute humidity and temperature outputs, and humidification and heating efficiencies of HMEs were calculated. MEASUREMENTS AND RESULTS: The Dar Hygroster had the highest humidity output, temperature output, humidification efficiency, and heating efficiency values throughout the study (32.8 +/- 21. mg/l, 32.2 +/- 0.8 degrees C, 86.3 +/- 2.3%, and 0.9 +/- 0.01%, respectively) in comparison to the Humid-Vent Filter (25.3 +/- 3.2 mg/l, 31.9 +/- 0.8 degrees C, 72.2 +/- 5.3%, 0.9 +/- 0.02%, respectively) and the Pall Ultipor BB100 breathing circuit filter (23.4 +/- 3 mg/l, 28.3 +/- 0.7 degrees C, 68.8 +/- 5.9%, 0.8 +/- 0.02%, respectively). The inspiratory and expiratory resistance of the HMEs remained below clinically acceptable maximum values (2.60 +/- 0.04 and 2.45 +/- 0.05 cmH2O/l per s, respectively). CONCLUSION: The Dar Hygroster filter was found to have the highest humidity and temperature output of all three HMEs, the Humid-Vent filter had a satisfactory humidity output only at low tidal volume flow rate and minute volume settings, whereas the Pall Ultipore BB 100 never achieved a sufficient humidity and temperature output.

Hot Temperature↗

Low-volume resuscitation with a hemoglobin-based oxygen carrier after hemorrhage improves gut microvascular oxygenation in swine.

Using palladium-porphyrin quenching of phosphorescence, we investigated the influence of diaspirin cross-linked hemoglobin (DCLHb) on gut microvascular oxygen pressure (microPO2) in anesthetized pigs. Values of gut microPO2 were studied in correlation with regional intestinal as well as global metabolic and circulatory parameters. A controlled hemorrhagic shock (blood withdrawal of 40 mL/kg) was followed by resuscitation with either a combination of lactated Ringer's solution (75 mL/kg) and modified gelatin (15 mL/kg)(lactR/Gel) or 10% DCLHb (5 mL/kg). After resuscitation, gut microPO2 was similarly improved in the lactR/Gel group (from 25 +/- 10 mm Hg to 53 +/- 8 mm Hg) and the DCLHb group (from 23 +/- 9 mm Hg to 46 +/- 6 mm Hg), which was associated with increased gut oxygen delivery. However, the improvement after resuscitation with DCLHb was sustained for longer periods of time (75 vs 30 min). Mesenteric venous PO2 was increased after resuscitation with lactated Ringer's solution and modified gelatin but not with DCLHb, which was associated with an increased gut oxygen consumption in the latter group. We conclude that measurement of microPO2 by the palladium-porphyrin phosphorescence technique revealed DCLHb to be an effective carrier of oxygen to the microcirculation of the gut. Also, this effect can be achieved with a lower volume than is currently used in resuscitation procedures.

Animals↗